• Title/Summary/Keyword: Elapsed-time Method

Search Result 231, Processing Time 0.032 seconds

Analysis of Holdup Characteristics of Large and Small Bubbles in Three-Phase Fluidized Beds by using a Dynamic Gas Disengagement Method (삼상유동층에서 동력학적 기체유출 측정방법에 의한 큰 기포와 작은 기포의 체류량 특성 해석)

  • Lim, Hyun Oh;Lim, Dae Ho;Seo, Myung Jae;Kang, Yong;Jung, Heon;Lee, Ho Tae
    • Korean Chemical Engineering Research
    • /
    • v.49 no.5
    • /
    • pp.605-610
    • /
    • 2011
  • Phase holdup characteristics of relatively large and small bubbles were investigated in a three-phase(gasliquid-solid) fluidized bed of which diameter was 0.105 m(ID) and 2.5 m in height, respectively. Effects of gas(0.01~0.07 m/s) and liquid velocities(0.01~0.07 m/s) and particle size($0.5{\sim}3.0{\times}10^{-3}m$) on the holdups of relatively large and small bubbles were determined. The holdups of two kinds of bubbles in three phase fluidized beds were estimated by means of static pressure drop method with the knowledge of pressure drops corresponding to each kind of bubble, respectively, which were obtained by dynamic gas disengagement method. Dried and filtered air which was regulated by gas regulator, tap water and glass bead of which density was $2500kg/m^3$ were served as a gas, a liquid and a fluidized solid phase, respectively. The two kinds of bubbles in three-phase fluidized beds, relatively large and small bubbles, were effectively detected and distinguished by measuring the pressure drop variation after stopping the gas and liquid flow into the column as a step function: The increase slope of pressure drop with a variation of elapsed time was quite different from each other. It was found that the holdup of relatively large bubbles increased with increasing gas velocity but decreased with liquid velocity. However, the holdup showed a local minimum with a variation of size of fluidized solid particles. The holdup of relatively small bubbles increased with an increase in the gas velocity or solid particle size, while it decreased slightly with an increase in the liquid velocity. The holdups of two kinds of bubbles were well correlated in terms of operating variables within this experimental conditions, respectively.

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

AN EXPERIMENTAL STUDY ON THE EFFECT OF Ca(OH)2 UPON THE HEALING PROCESS OF THE PULP AND PERIAPICAL TISSUE IN THE DOGS' TEETH (수산화칼슘이 손상치수조직 및 치근조직의 치유에 미치는 영향에 관한 연구)

  • Lim, S.S.;Yoon, S.H.;Lee, C.S.;Lee, M.J.;Kim, Y.H.;Kwon, H.C.;Um, C.M.
    • Restorative Dentistry and Endodontics
    • /
    • v.8 no.1
    • /
    • pp.123-131
    • /
    • 1982
  • The purpose of this study was to observe the responses of the remaining pulp tissue after pulpotomy upon the several kinds of $Ca(OH)_2$ products and the responses of periapical tissue upon some root canal filling materials after extirpation. For pulpotomy, the class V cavities were prepared on the premolars, molars and upper canines, and the pulp was amputated. Each drug was placed over the amputated tissue and cavity was sealed with zinc oxide eugenol cement. The drugs which were used for the study were Dycal (Caulk Co. U.S.A.), Cavitec (Kerr Co. U.S.A.), Calvital, Nobudyne and Neodyne (Neo Dental Chemical Products). For extirpation, the endodontic cavities were prepared on the lingual surfaces of anterior teeth, and the pulp tissues were extirpated as routine method. After enlarging, irrigation, and measuring of root length by taking X-ray, each root canal filling material was filled in the canal with gutta percha cone, and endodontic cavity was sealed with zinc oxide eugenol cement. Zinc oxide eugenol, $Ca(OH)_2$ (Eli Lilly Co. U.S.A.) and Vitapex (Neo Dental Chemical Products) were used as root canal filling materials. Animals were sacrificed after 1, 3 and 6 weeks following the operation. The teeth were decalcified in formic acid, sectioned and stained with hematoxylin eosin. Microscopic examination revealed as follows. 1. Dycal: The dentin bridge formation was observed at the 3rd week after pulpotomy. Inflammatory conditions which were infiltration of inflammatory cells and dilatation of blood vessels were kept in remaining pulp tissue at the 6th week. 2. Calvital: The dentin bridge was observed at the 1st week after pulpotomy. As the time clasped, the pulp tended to be the fibrous degeneration. 3. Cavitec, Nobudyne and Neodyne: In the case of Cavitec and Nobudyne, the incompleted and irregular dentin bridge was observed at the 6th week, and in Neodyne, was observed at the 3rd week. The severe inflammatory changes were seen in the remaining pulp tissue. As the time clasped, the fibrous degeneration tended to spread in the remaining pulp tissue. 4. $Ca(OH)_2$: Osteocementum was formed at the 3rd week, the matrix of cementum and dentin were resorted, and infiltration of lymphocytes was seen in periapical tissue when $Ca(OH)_2$ was used as canal-filling materials. S. ZOE and Vitapex The cementum like substance was seen in periapical portion at the 1st week, when ZOE and Vitapex were used as root canal filling materials. As the time elapsed, the matrix of cementum and dentin tended to be resorted. At the 6th week, the inflammatory condition of periapical tissue was continued in the case of ZOE, but was reduced in the case of Vitapex.

  • PDF

EFFECT OF SOFT-START CURING ON THE CONTRACTION STRESS OF COMPOSITE RESIN RESTORATION POLYMERIZED WITH LED AND PLASMA CURING UNIT (LED와 플라즈마 광원의 완속기시 광중합 방식이 복합레진의 수축응력에 미치는 영향)

  • Chung, Yang-Seok;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.623-631
    • /
    • 2007
  • Effect of Soft-start curing on the contraction stress of composite resin restoration polymerized with LED and plasma curing unit The purpose of this study was to evaluate the influence of soft-start light curing on contraction stress and hardness of composite resin. Composite resin (Filtek $Z-250^{TM}$, 3M ESPE, USA) was cured using the one-step continuous curing method with three difference light sources ; conventional halogen light ($XL3000^{TM}$, 3M ESPE, USA) cure for 40 seconds at $400 mw/cm^2$, LED light (Elipar Freelight $2^{TM}$, 3M-ESPE, USA) cure for 20 seconds at $800\;mW/cm^2$ a and plasma arc light ($Flipo^{TM}$, LOKKI, France) cure for 12 seconds at $1300 mW/cm^2$. For the soft-start curing method ; LED light (Elipar Freelight $2^{TM}$, 3M-ESPE, USA) cure exponential increase with 5 seconds followed by 17 seconds at $800\;mW/cm^2$ and plasma arc light ($Flipo^{TM}$, LOKKI, France) cure 2 seconds light exposure at $650\;mW/cm^2$ followed by 11 seconds at $1300\;mW/cm^2$. The strain guage method was used for determination of polymerization contraction. Measurements were recorded at each 2 second for the total of 800 seconds including the periods of light application. Obtained data were analyzed statically using Repeated measures ANOVA, One way ANOVA, and Tukey test. The results of present study can be summarized as follows: 1. Composite resin restoration showed transient expansion just after irradiation of curing light. Contraction stress was increased rapidly at the early phase of polymerization and reduced slowly as time elapsed (P<0.05). 2. Contraction stress was not revealed significant difference between Halogen curing light groups and LED and Plasma Light curing with soft-start group (P>0.05). 3. LED and Plasma Light curing with soft-start showed lower contraction stress than the one-step continuous light curing (P<0.05).

  • PDF

Growth Effect of Oncorhychus masou by Recombinant Myostatin Prodomain Proteins Derived from Fish (어류 유래 마이오스타틴 프로도메인 단백질에 의한 시마연어(Oncorhychus masou) 성장효과)

  • Kim, Jeong-Hwan;Lee, Sang-Beum;Cho, Mi-Jin;Ahn, Ji-Young;Lee, Suk-Keun;Hong, Sung-Youl;Seong, Ki-Baik;Jin, Hyung-Joo
    • Journal of Life Science
    • /
    • v.21 no.8
    • /
    • pp.1149-1155
    • /
    • 2011
  • Myostatin (MSTN) belongs to the transforming growth factor-${\beta}$ superfamily or growth and differentiation factor 8 (GDF-8), and functions as a negative regulator of skeletal muscle development and growth. Previous studies in mammals have suggested that myostatin knock-out increased muscle mass and decreased fat content compared to those of the wide type. Recently, several studies on myostatin have beenconducted on the block myostatin signal pathway with myostatin antagonists and the MSTN regulation with RNAi to control myostatin function. This study was performed to analyze growth and muscle alteration of Oncorhychus masou by treatment with recombinant myostatin prodomains derived from fish. We designed myostatin prodomains derived from P. olivaceus (pMALc2x-poMSTNpro) and S. schlegeli (pMALc2x-sMSTNpro) in a pMALc2x expression vector, and then purified the recombinant proteins using affinity chromatography. The purified recombinant proteins were treated in O. masou through an immersion method. Recombinant protein treated groups did not show a significant difference in weight, protein, or lipid composition compared to the control. However, there was a difference in the average number and area for histological analyses in the muscle fiber. At twelve and twenty-two weeks from the initial treatment, there were differences in averagefiber number and area between the 0.05 mg/l treated-group and the control, but the numbers were similar to those of the control during the same time period. At twelve weeks, however, 0.2 mg/l treated-group had an increase in average fiber number and decrease in average fiber area compared to the control. At twenty-two weeks, the pMALc2x-sMSTNpro 0.2 mg/l treated-group was induced and showed a decrease in average fiber number and increase in average fiber area. The results between twelve and twenty-two weeks showed that the fiber numbers had decreased, whereas average fiberarea had increased due to sMSTNpro. It is understood that the sMSTNpro induced only hyperplasia at twelve weeks, after which it induced hypertrophy. Recombinant myostatin prodomains derived from fish may induce hyperplasia and hypertrophy in O. masou depending upon the time that has elapsed.

Changes of Major Components and Microorganisms during the Fermentation of Korean Ordinary Kochujang (한국재래식(韓國在來式)고추장숙성중(熟成中)의 주요성분(主要成分) 및 미생물(微生物)의 변화(變化))

  • Ahn, Cheol-Woo;Sung, Nack-Kie
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.16 no.3
    • /
    • pp.35-39
    • /
    • 1987
  • The present study was attempted to obtain the basic data concerning a reasonable preparing method and the optimum fermentation conditions of Kochujang (Red pepper paste). To establish the standard qualify of Kochujang, changes of the chemical composition and the numbers of bacteria and feasts in Kochujang during fermentation were observed. Moisture, salts and crude ash contents of Kochujang were not changed significantly during fermentation. Titrable acidity and amino nitrogen gradually increased with the time-passed, whereas crude fat gradually decreased with the time-elapsed. And reducing sugar and total nitrogen increased until 40 days, but slightly decreased after this period. The numbers of bacteria and yeasts in the ingrients for the preparation of Kochujang were $3.9{\times}10^7/g$, $1.5{\times}10^3/g$ in red pepper powder, $7.6{\times}10^4/g$, $2.8{\times}10^2/g$ in salts. respectively, but those of sugar and malt were not more than 100/g. Microbial counts in Kochujang during fermentation increased until 40 days, but those are gradually decreased after that.

  • PDF

Optimum Management Plan for Soil Contamination Facilities (특정토양오염관리대상시설의 최적 관리방안에 관한 연구)

  • Park, Jae-Soo;Kim, Ki-Ho;Kim, Hae-Keum;Choi, Sang-Il
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.2
    • /
    • pp.293-300
    • /
    • 2012
  • This study was to investigate the unsuitable rate of the storage facilities, the changes in corrosion process over time after installation according to the status, the time to install the facilities, years elapsed after facilities installation, inspection of methods and motivation, and so on, based on the results of the inspection at the petroleum storage facilities conducted by domestic soil-relate specialized agency to derive optimal management plans which meet the status of soil contamination facilities. The results showed that the facilities more than 5 years after the initial leak test at the time of the installation need to be inspected periodically by considering costs of leak test and remediation of polluted soil. The inspection period can be decided by cost and leak test methods showing discrepancies for the results obtained from individual test whether it was direct or indirect. To compensate these matters, we suggested that the direct inspection method on regular schedule is recommended. On the other hand, the inspection can be voluntarily completed to ease burden of the results by inspection or equivalent level to this inspection method. Also, it may need improved construction supervision and performance test system to minimize the occurrence of the nature defects in installing the facilities as well as the upgrade program for the facilities during intervals of inspection period.

A Study on the Management Method in Accordance with the Vegetation Structure of Geumgang Pine (Pinus densiflora) Forest in Sogwang-ri, Uljin (울진 소광리 금강소나무림 식생구조 특성에 따른 관리방안)

  • Kim, Dong-Wook;Han, Bong-Ho;Park, Seok-Cheol;Kim, Jong-Yup
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.1
    • /
    • pp.1-19
    • /
    • 2022
  • The Geumgang Pine (Pinus densiflora) Forest in Sogwang-ri, Uljin has traditionally been a pine tree protection area (prohibited forest) for timber production purposes, and is now designated and managed as a protected area for forest genetic resource conservation by the Korea Forest Service. This study, we analyzed topographical characteristics, existing vegetation, tree age, and plant community structure, and proposed a sustainable management method for the Geumgang Pine (Pinus densiflora) Forest in Sogwang-ri, Uljin for timber havesting purposes. The topographical characteristics of the target area were 36.7% ridges and 38.7% valleys; the ratio of ridges to valleys was similar, and the slopes formed 24.7% of the total area. The types of pine forest communities are divided into six types based on the progress of pine forest renewal, the competition with other species such as deciduous broadleaf trees, and the formation of layered structures. It has been confirmed that the age of the large-diameter pine trees (40~60cm in diameter) is approximately 60~70 years, which is relatively low. As a result of the analysis of the relative importance percentage and layered structure, differences depended on the progress of the pine forest renewal project, and not only the maintenance of the pine forest, but also the creation of a secondary growth forest, the density adjustment of pine trees, and the active management of competitive trees. The average basal area by the community was 12,642.1~25,424.4cm2 for the tree layer and 1.8~1,956.5cm2 for the low tree layer based on a quadrat of 400m2. The difference in the basal area appeared to depend on the size and number of trees forming the tree layer and the degree of pine forest renewal (the degree of time elapsed after thinning pine trees). The average number of species that appeared in each community was 8.7-20.3; there were many species located in valleys, and the type competes with deciduous broadleaf trees due to the lack of management. The diversity of species ranged from 0.6915-1.0942, and was evaluated as low compared to pine communities in central temperate zones. In this paper, we determined the management goals of Geumgang Pine (Pinus densiflora) Forest in Sogwang-ri, Uljin to produce timber with high economic value, and suggested efficient vegetation management for continuous afforestation, the establishment of a timber production system, and improvement of wood production as a management direction.

The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan (전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Ryu, Jae-Kwang;Yoo, Jae-Sook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • Purpose: In Asan Medical Center we perform myocardial perfusion SPECT to evaluate cardiac event risk level for non-cardiac surgery patients. In case of patients with cancer, we check tumor metastasis using whole body bone scan and whole body PET scan and then perform myocardial perfusion SPECT to reduce unnecessary exam. In case of short term in patients, we perform $^{201}Tl$ myocardial perfusion SPECT after whole body bone scan a minimum 16 hours in order to reduce hospitalization period but it is still the actual condition in which the evaluation about the affect of the crosstalk contamination due to the each other dissimilar isotope administration doesn't properly realize. So in our experiments, we try to evaluate crosstalk contamination influence on $^{201}Tl$ myocardial perfusion SPECT using anthropomorphic torso phantom and patient's data. Materials and Methods: From 2009 August to September, we analyzed 87 patients with $^{201}Tl$ myocardial perfusion SPECT. According to $^{201}Tl$ myocardial perfusion SPECT yesterday whole body bone scan possibility of carrying out, a patient was classified. The image data are obtained by using the dual energy window in $^{201}Tl$ myocardial perfusion SPECT. We analyzed $^{201}Tl$ and $^{99m}Tc$ counts ratio in each patients groups obtained image data. We utilized anthropomorphic torso phantom in our experiment and administrated $^{201}Tl$ 14.8 MBq (0.4 mCi) at myocardium and $^{99m}Tc$ 44.4 MBq (1.2 mCi) at extracardiac region. We obtained image by $^{201}Tl$ myocardial perfusion SPECT without gate method application and analyzed spatial resolution using Xeleris ver 2.0551. Results: In case of $^{201}Tl$ window and the counts rate comparison result yesterday whole body bone scan of being counted in $^{99m}Tc$ window, the difference in which a rate to 24 hours exponential-functionally notes in 1:0.114 with Ventri (GE Healthcare, Wisconsin, USA), 1:0.249 after the bone tracer injection in 12 hours in 1:0.411 with 1:0.79 with Infinia (GE healthcare, Wisconsin, USA) according to a reduction a time-out was shown (Ventri p=0.001, Infinia p=0.001). Moreover, the rate of the case in which it doesn't perform the whole body bone scan showed up as the average 1:$0.067{\pm}0.6$ of Ventri, and 1:$0.063{\pm}0.7$ of Infinia. According to the phantom after experiment spatial resolution measurement result, and an addition or no and time-out of $^{99m}Tc$ administrated, it doesn't note any change of FWHM (p=0.134). Conclusion: Through the experiments using anthropomorphic torso phantom and patients data, we found that $^{201}Tl$ myocardium perfusion SPECT image later carried out after the bone tracer injection with 16 hours this confirmed that it doesn't receive notable influence in spatial resolution by $^{99m}Tc$. But this investigation is only aimed to image quality, so it needs more investigation in patient's radiation dose and exam accuracy and precision. The exact guideline presentation about the exam interval should be made of the validation test which is exact and in which it is standardized about the affect of the crosstalk contamination according to the isotope use in which it is different later on.

  • PDF

A Kinematic Analysis of Uchi-mata(inner thigh reaping throw) by Kumi-kata types in Judo (유도 맞잡기 타입에 따른 허벅다리걸기의 Kinematic 분석[I])

  • Kim, Eui-Hwan;Cho, Dong-Hee;Kwon, Moon-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.1
    • /
    • pp.63-87
    • /
    • 2002
  • The purpose of this study was to analyze the kinematic variables when Uchi-mata(inner thigh reaping throw) performing by Kumi-kata(engagement position, basic hold) types A, B(A: grasping part-behind neck lapel, B: chest lapel) in Judo with three dimensional analysis technique DLT method by videography. The subjects were four male judokas who have been training in Yong-In University(YIU), on Korean Representative level and Uchi-mata is their tokui-nage(favorite technique), the throwing form was filmed on two S-VHS 16mm video camera( 30frame/sec. Panasonic). Kinematic variables were temporal, posture, and COG. The data collection was performing by Uchi-mata. Six good trials were collected for each condition (type A, B) among over 10 trials. The mean values and the standard deviation for each variable were obtained and used as basic factors for examining characteristics of Uchi-mata by Kumi-kata types. The results of this analysis were as follows : 1) Temporal variables The total time elapsed(TE) by Uchi-mata of types A, B were 1.45, 1.56 sec. respectively. Types A shorter than B. 2) Posture variables In performing of Uchi-mata, the range of flexion in type A, left elbow was $45^{\circ}$ and B was $89^{\circ}$ from Event 2(E2) to Event 6(E6). Type A and B were quite different in right elbow angle in Event1(E1). Left shoulder angle of type A was extended and type B was flexed in E4. Both types right shoulder angles were showed similar pattern. Also both hip angles(right/left) were showed similar pattern. When type A performed Uchi-mata the knee-angle of supporting foot showed $142^{\circ}$in the 1st stage of kake phase[KP], and extended to $147^{\circ}$in the 2nd stage of KP. And the foot-ankle angle of supporting foot showed $83^{\circ}$in the 1st stage of KP, and extended to $86^{\circ}$in the 2nd stage of KP. moreover, The knee angle of attacking foot showed $126^{\circ}$in the 1st stage of KP, and extended to $132^{\circ}$in the 2nd stage of KP, and the foot-ankle angle of attacking foot showed $106^{\circ}$in the 1st stage of KP, and extended to $121^{\circ}$in the 2nd stage of KP. When type B performed Uchi-mata the knee-angle of supporting foot showed $144^{\circ}$in the 1st stage of KP, and extended to $154^{\circ}$in the 2nd stage of KP. And the foot-ankle angle of supporting foot showed $83^{\circ}$in the 1st stage of KP, and extended to $92^{\circ}$in the 2nd stage of KP. moreover, The knee angle of attacking foot showed $132^{\circ}$in the 1st stage of KP, and extended to $140^{\circ}$in the 2nd stage of KP, and the foot-ankle angle of attacking foot showed $103^{\circ}$in the 1st stage of KP, and extended to $115^{\circ}$in the 2nd stage of KP. During Uchi-mata performing, type A showed pulling pattern and type B showed lift-pulling pattern. As Kumi-kata types, it were different to upper body(elbow, shoulder angle), but mostly similar to lower body(hip, knee, ankle angle) on both types. 3) C. O. G. variables When the subjects performed Uchi-mata, COG of type A, B up and down in vertical aspect was 71cm, 73.8cm in height from the foot in the 2nd stage of KP. As Kumi-kata types, it were different on medial-lateral direction aspect but weren't different in Kuzushi phase on vertical direction aspect.