• 제목/요약/키워드: Ejection Function

검색결과 159건 처리시간 0.022초

Monte Carlo Simulation on Reliability of a Self-Separable Ejector for Man-Portable Missiles

  • Lee, Hyo-Nam;Oh, Jong-Yun
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제12권4호
    • /
    • pp.385-395
    • /
    • 2011
  • An ejector was developed for man-portable missiles. The ejector can be separated from the missile after the completion of the ejection function even without any additional separation devices. This paper introduces the particular separation mechanism of the ejector and presents the methodology, based on a probabilistic design method, to predict the ejection-and-separation reliability. This approach using Monte Carlo simulation can also be applicable to the reliability prediction of one-shot items suffering from difficulties in estimating or in demonstrating their reliability due to the lack of the number of tests available.

Development and verification of PWR core transient coupling calculation software

  • Li, Zhigang;An, Ping;Zhao, Wenbo;Liu, Wei;He, Tao;Lu, Wei;Li, Qing
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3653-3664
    • /
    • 2021
  • In PWR three-dimensional transient coupling calculation software CORCA-K, the nodal Green's function method and diagonal implicit Runge Kutta method are used to solve the spatiotemporal neutron dynamic diffusion equation, and the single-phase closed channel model and one-dimensional cylindrical heat conduction transient model are used to calculate the coolant temperature and fuel temperature. The LMW, NEACRP and PWR MOX/UO2 benchmarks and FangJiaShan (FJS) nuclear power plant (NPP) transient control rod move cases are used to verify the CORCA-K. The effects of burnup, fuel effective temperature and ejection rate on the control rod ejection process of PWR are analyzed. The conclusions are as follows: (1) core relative power and fuel Doppler temperature are in good agreement with the results of benchmark and ADPRES, and the deviation between with the reference results is within 3.0% in LMW and NEACRP benchmarks; 2) the variation trend of FJS NPP core transient parameters is consistent with the results of SMART and ADPRES. And the core relative power is in better agreement with the SMART when weighting coefficient is 0.7. Compared with SMART, the maximum deviation is -5.08% in the rod ejection condition and while -5.09% in the control rod complex movement condition.

체위변화시 심장의 수축기 시간간격 및 Heather Index의 변화 (Cardiac systolic time intervals and heather index measured by impedance cardiography during postural changes)

  • 고성경;김창규;김덕원
    • 대한인간공학회지
    • /
    • 제11권1호
    • /
    • pp.67-79
    • /
    • 1992
  • Cardiac systolic time intervals (STLs) and Heather index (HI) were used to access changes in left ventricular function of six male subjects exposed to postural changes,$0^{\circ}C$, ${\pm}2^{\circ}C$, ${\pm}45^{\circ}C$, ${\pm}90^{\circ}C$, Significant prolongation of the pre-ejection period (PEP) and PEP/ LVET ratio, shortening of the left ventricular ejection time (LVET), STI, HI and $1/PEP^{2}$were observed during exposure to both $+45^{\circ}C $ and $+90^{\circ}C $But the values measured during $-45^{\circ}C $ and$-90^{\circ}C $ were reversed. Changes in fluid shift, filling volume, preload, after load and sympathetic activities may account for the observed findings. Early response of cardiac foctions was recorded using impedance cardiography. This method is very simple but accurate. Thus it will be useful in this aerospace and work physiology. In conclusion, STIs appear to provide reliable noninvasive method for examining changes of cardiac function during exposure to postural changes.

  • PDF

심전도 게이트 심근관류 Tl-201 SPECT로 측정된 좌심실 기능 및 좌심실 용적의 정확성 (Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography)

  • 배문선;문대혁
    • 대한핵의학회지
    • /
    • 제39권2호
    • /
    • pp.94-99
    • /
    • 2005
  • Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.

방사선동위원소 심혈관촬영술을 이용한 우심실기능 측정에 관한 연구 -만성폐쇄성 폐질환에서의 우심실 Ejection Fraction- (Evaluation of Right Ventricular Function with Radionuclide Cardiac Angiography: Right Ventricular Ejection Fraction in Chronic Obstructive Lung Disease)

  • 손인;신성해;정준기;이명철;조보연;이영우;한용철;고창순
    • 대한핵의학회지
    • /
    • 제16권1호
    • /
    • pp.1-6
    • /
    • 1982
  • To evaluate the usefulness of radionuclide cardiac angiography in the assessment of right ventricular function, we measured right ventricular ejection fraction (RVEF) using single pass method. In 12 normal persons, RVEF averaged $52.7{\pm}5.9%(mean{\pm}S.D.)$. In 25 patients with chronic obstructive lung disease, RVEF was $37.2{\pm}10.6%$ and significantly lower than that of normal persons (p<0.01). All 10 patients with right ventricular failure had abnormal RVEF, which was significantly lower than that of 14 patients without right ventricular failure ($27.6{\pm}5.7%,\;43.9{\pm}8.5%$, respectively. p<0.01). It concluded thal RVEF measured by single pass radionuclide cardiac angiography was a useful, noninvasive method to assess right ventricular function.

  • PDF

Cardiac MRI를 이용한 심박출계수의 평가 (Evaluation of Cardiac Ejection Fraction using Cardiac MRI)

  • 은성종;국진선
    • 한국방사선학회논문지
    • /
    • 제5권5호
    • /
    • pp.289-294
    • /
    • 2011
  • 본 연구의 목적은 cardiac MRI를 이용하여 확장기와 수축기의 정량적 측정을 통해 각 단면의 심박출률의 차이를 알아보고자 하였다. 총 12명(정상 7명, 심근교 1명, 부정맥 4명)을 대상으로 심첨에서부터 대동맥궁 쪽으로 단면을 얻었다. 수축기와 확장기 영상을 확대하여 경계를 정하였고, 이 면적을 바탕으로 1, 3, 5, 6-7단면의 심박출률을 구하였다. 정상인의 평균 박출률은 각각 1, 3, 5, 6-7단면에서 67.14%, 66.24%, 65.63%, 그리고 65.29% 로 나타났다. 반면, 환자들의 평균 박출률은 각각 1, 3, 5, 6-7단면에서 61.74%, 60.92%, 60.89%, 그리고 61.89%로 나타났다. 본 연구를 통해 cardiac MRI를 이용한 특정단면의 심박출률은 각 단면마다 큰 차이가 없음을 알 수 있었고 따라서 cardic MRI를 이용한 심박출계수의 평가는 대표 단면만으로 가능함을 알 수 있었다.

Determinants of the Volumetric Markers of Left Atrial Contraction Function in Coronary Artery Disease: A Cross-sectional Study

  • Taimoor Etemad;Ali Hosseinsabet;Negar Omidi;Reza Mohseni-Badalabadi
    • Journal of Cardiovascular Imaging
    • /
    • 제30권1호
    • /
    • pp.37-46
    • /
    • 2022
  • BACKGROUND: A body of research advocates the prognostic role and usefulness of the volumetric markers of left atrial (LA) phasic functions in the diagnosis of LA dysfunction. We aimed to determine the independent determinants of the volumetric markers of LA contraction function in candidates for coronary artery bypass graft (CABG) surgery. METHODS: This cross-sectional study enrolled 516 candidates for CABG. The biplane maximal, minimal, and pre-P volumes of the LA were measured with two-dimensional echocardiography, and LA active emptying fraction was calculated. The standardized correlation coefficient for the correlation between each factor and LA active emptying fraction was calculated by using univariate and backward multivariable regression analyses. RESULTS: The multivariable regression analysis demonstrated that the heart rate (β = 0.15; p = 0.001), S (β = 0.09; p = 0.036), E/e' ratio (β = -0.11; p = 0.014), left ventricle (LV) ejection fraction (β = 0.15; p = 0.001), and LA enlargement (β = -0.19; p < 0.001) were the independent determinants of LA active emptying fraction. CONCLUSIONS: The independent determinants of LA contraction function were the heart rate, S, LV ejection fraction, LA enlargement, and E/e' ratio in candidates for CABG surgery.

심근경색 유발견에서 마취가 심초음파에 미치는 영향 (Effects of anesthesia on echocardiograms in myocardial infarcted dogs)

  • 윤정희;성재기
    • 대한수의학회지
    • /
    • 제37권3호
    • /
    • pp.669-685
    • /
    • 1997
  • The present study was performed to evaluate the effects of xylazine and tiletamine + zolazepam on echocardiograms before and after experimental myocardial infarctions in clinically normal dogs taken preliminary examinations related to cardiac function. The results are as follows. With xylazine administration, left ventricle end-diastolic dimension, left ventricle end-systolic dimension, left atrium/aorta, ejection time and velocity of circumferential fiber shortening increased and mitral valve CD slope, % delta D decreased(p<0.01). In tiletamine+zolazepam administered group, interventricular septum amplitude(p<0.01), mitral valve DE slope(p<0.05) and ejection time(p<0.01) decreased and left atrium/aorta, ejection time also decreased compared with xylazine group(p<0.01). In 48 hours after experimental myocardial infarction group, anterior aortic wall amplitude decreased compared with control, xylazine, tiletamine + zolazepam group, respectively(p<0.01). Posterior aortic wall amplitude decreased compared with control(p<0.01). Left ventricle end systolic dimension increased compared with control and tiletamine + zolazepam group, respectively(p<0.01). Left ventricular posterior wall end systolic dimension decreased compared with control(p<0.01). Left ventricular posterior wall amplitude decreased compared with control and tiletamine+zolazepam group(p<0.01). Left atrium/aorta decreased compared with xylazine group(p<0.01). % thickening left ventricular posterior wall decreased compared with control(p<0.05). % delta D decreased compared with control and tiletamine+zolazepam group(p<0.01). Ejection time decreased compared with xylazine(p<0.01). Velocity of circumferential fiber shortening increased compared with control and tiletamine + zolazepam group(p<0.01). With xylazine administration 48 hours after experimental myocardial infarction, anterior aortic wall amplitude, posterior aortic wall amplitude decreased compared with control(p<0.01). Left ventricle end-diastolic dimension increased compared with control(p<0.01). Left ventricle end-systolic dimension increased compared with control and tiletamine + zolazepam group, respectively(p<0.01). Left ventricular posterior wall end-systolic dimension and left ventricular posterior wall end-diastolic dimension decreased compared with control(p<0.01). Left atrium/aorta decreased compared with xylazine group(p<0.01). % thickening left ventricular posterior. wall(p<0.05) and % delta D(p<0.01) decreased compared with control. Velocity of circumferential fiber shortening increased compared with tiletamine + zolazepam group(p<0.01). With tiletamine + zolazepam administration 48 hours after experimental myocardial infarction, anterior aortic wall amplitude decreased compared with control, xylazine and tiletamine+zolazepam group, respectively(p<0.01). Posterior aortic wall amplitude decreased compared with control(p<0.01). Left ventricle end-systolic dimension increased compared with control and tiletamine+zolazepam group(p<0.01). Left ventricular posterior wall end-systolic dimension, left ventricular posterior wall end-diastolic dimension and interventricular septum amplitude decreased compared with control(p<0.01). Left atrium/aorta decreased compared with xylazine group(p<0.01). % delta D decreased compared with control and tiletamine + zolazepam group(p<0.01). Ejection time decreased compared with xylazine group and velocity of circumferential fiber shortening increased compared withtiletamine+zolazepam group(p<0.01). Conclusively, echocardiography was proved to be a useful, diagnostic, non-invasive and simple method for establishing the diagnosis of myocardial infarction and evaluating the effects of drug on cardiac function before and after myocardial infarction.

  • PDF

방사성 동위원소를 이용한 개심술 전후의 심실기능 변화에 관한 연구: ECG gated blood pool scan을 이용한 ejection fraction 검사 (Clinical Study of Ventricular Function Following Open Heart Surgery by Radionuclide Angiocardiogram - left ventricular ejection fraction by ECG gated blood pool scan -)

  • 이정철;김규태
    • Journal of Chest Surgery
    • /
    • 제19권1호
    • /
    • pp.25-34
    • /
    • 1986
  • Recently, radionuclide angiocardiogram is one of the most common procedure for assessment of ventricular performance due to its distinctive advantages such as safety, accuracy, and ease of repeated studies. Also, measurement and comparison between pre and postoperative left ventricular ejection fraction [LVEF] are meaningful for assessing the severity of myocardial damage which occurred during open heart surgery and the status of myocardial recovery. We obtained pre and post operative LVEF using radionuclide angiocardiogram on 30 patients composed of atrial septal defect, ventricular septal defect, cyanotic congenital heart disease, and valvular heart disease who undergone the open heart surgery from March to august 1984. The study revealed that ventricular septal defect and mitral valvular heart disease showed 8.1% and 6.2% decreases of postoperative LVEF, respectively. But, there are little increases of postoperative LVEF in the atrial septal defect and cyanotic congenital heart disease. In ventricular septal defect, each group of Qp/Qs over 2.0 and systolic pulmonary artery pressure over 50mmHg showed significant 17% and 14.7% decreases of postoperative LVEF, respectively. Considering the duration of the aortic cross clamping times and closing methods of VSD, each group of duration over 30 min. and of patch closure showed 13.9% and 14.2% decreases of LVEF between pre and postoperative status respectively which was significant finding statistically.

  • PDF

관상동맥질환에서 Gated Blood Pool Scan을 이용한 좌심실 확장기능의 분석 (Analysis of Left Ventricular Diastolic Function in Coronary Artery Disease with Gated Blood Pool Scan)

  • 최창운;임상무;정준기;이명철;박영배;서정돈;이영우;고창순
    • 대한핵의학회지
    • /
    • 제20권2호
    • /
    • pp.39-45
    • /
    • 1986
  • Resting gated blood pool scan was used to derive left ventricular functional changes in normals (N=13, mean age=43) and in patients with coronary artery disease (N=50, mean age=53). Peak filling rates, average filling rates, and ejection fractions were significantly depressed in coronary artery disease. (p<0.0005, each other). And in coronary artery disease with normal ejection fraction (N=21), peak filling rates and average filling rates were depressed also, and peak filling rates of coronary artery disease with normal ejection fraction were abnormal in 61.2% and average fillin rates were abnormal in 71.4%. It appears that (1) resting peak filling rates and average filling rates were sensitive and easily obtainable parameters of the diastolic dysfunction assosiated with coronary artery disease, (2) a significant proportion of coronary artery disease patients without any evidence of abnormal systolic function have depressed resting peak filling rates and average filling rates of the left ventricle.

  • PDF