• 제목/요약/키워드: Ejection Fraction

검색결과 318건 처리시간 0.035초

COVID-19 백신 접종 후 발생한 전신 부종에 대한 한양방 복합치료 치험 1례 (A Case of Generalized Edema in a Patient after COVID-19 Vaccination Improved by a Combined Korean-Western Medicine Approach)

  • 이영선;정소민;이한결;조기호;문상관;정우상;권승원
    • 대한한방내과학회지
    • /
    • 제44권5호
    • /
    • pp.957-967
    • /
    • 2023
  • Background: According to Vaccine Adverse Events Reporting System data, generalized edema followed by the COVID-19 vaccine is uncommon, with only 333 reported cases, and of those, 224 (69%) are associated with the Pfizer-BioNTech vaccine. Case report: A 76-year-old male patient with heart failure with preserved ejection fraction presented with spontaneous generalized edema and otherwise normal cardiac exams following administration of BNT162b2 (Pfizer-BioNTech) COVID-19 vaccination that had lasted for approximately 60 days and was treated successfully using Korean medicine treatment. After the administration of Korean medicine treatment, the patient's symptoms in the bilateral limbs were dramatically controlled, without recurrence, for 2 months. As a result, generalized edema, which had been present for approximately 50 days, dramatically improved. Conclusion: This clinical case study suggests that a Korean medicine approach with Mokbangki-tang and Oryeong-san might be effective for the pleural effusion resolution of generalized edema after COVID-19 vaccination.

Bilateral Cardiac Sympathetic Denervation as a Safe Therapeutic Option for Ventricular Arrhythmias

  • Soo Jung Park;Deok Heon Lee;Youngok Lee;Hanna Jung;Yongkeun Cho
    • Journal of Chest Surgery
    • /
    • 제56권6호
    • /
    • pp.414-419
    • /
    • 2023
  • Background: The recurrence of ventricular arrhythmias (VAs) in patients who have already undergone treatment with antiarrhythmic medication, catheter ablation, and the insertion of implantable cardioverter defibrillators is not uncommon. Recent studies have shown that bilateral cardiac sympathetic denervation (BCSD) effectively treats VAs. However, only a limited number of studies have confirmed the safety of BCSD as a viable therapeutic option for VAs. Methods: This single-center study included 10 patients, who had a median age of 54 years (interquartile range [IQR], 45-65 years) and a median ejection fraction of 58.5% (IQR, 56.2%-60.8%), with VAs who underwent video-assisted BCSD. BCSD was executed as a single-stage surgery for 8 patients, while the remaining 2 patients initially underwent left cardiac sympathetic denervation followed by right cardiac sympathetic denervation. We evaluated postoperative complications, the duration of hospital stays, and VA-related symptoms before and after surgery. Results: The median hospital stay after surgery was 2 days (IQR, 2-3 days). The median surgical time for BCSD was 113 minutes (IQR, 104-126 minutes). No significant complications occurred during hospitalization or after discharge. During the median follow-up period of 13.5 months (IQR, 10.5-28.0 months) from surgery, no VA-related symptoms were observed in 70% of patients. Conclusion: The benefits of a short postoperative hospitalization and negligible complications make BCSD a safe, alternative therapeutic option for patients suffering from refractory VAs.

Cardiac CT for Measurement of Right Ventricular Volume and Function in Comparison with Cardiac MRI: A Meta-Analysis

  • Jin Young Kim;Young Joo Suh;Kyunghwa Han;Young Jin Kim;Byoung Wook Choi
    • Korean Journal of Radiology
    • /
    • 제21권4호
    • /
    • pp.450-461
    • /
    • 2020
  • Objective: We performed a meta-analysis to evaluate the agreement of cardiac computed tomography (CT) with cardiac magnetic resonance imaging (CMRI) in the assessment of right ventricle (RV) volume and functional parameters. Materials and Methods: PubMed, EMBASE, and Cochrane library were systematically searched for studies that compared CT with CMRI as the reference standard for measurement of the following RV parameters: end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), or ejection fraction (EF). Meta-analytic methods were utilized to determine the pooled weighted bias, limits of agreement (LOA), and correlation coefficient (r) between CT and CMRI. Heterogeneity was also assessed. Subgroup analyses were performed based on the probable factors affecting measurement of RV volume: CT contrast protocol, number of CT slices, CT reconstruction interval, CT volumetry, and segmentation methods. Results: A total of 766 patients from 20 studies were included. Pooled bias and LOA were 3.1 mL (-5.7 to 11.8 mL), 3.6 mL (-4.0 to 11.2 mL), -0.4 mL (5.7 to 5.0 mL), and -1.8% (-5.7 to 2.2%) for EDV, ESV, SV, and EF, respectively. Pooled correlation coefficients were very strong for the RV parameters (r = 0.87-0.93). Heterogeneity was observed in the studies (I2 > 50%, p < 0.1). In the subgroup analysis, an RV-dedicated contrast protocol, ≥ 64 CT slices, CT volumetry with the Simpson's method, and inclusion of the papillary muscle and trabeculation had a lower pooled bias and narrower LOA. Conclusion: Cardiac CT accurately measures RV volume and function, with an acceptable range of bias and LOA and strong correlation with CMRI findings. The RV-dedicated CT contrast protocol, ≥ 64 CT slices, and use of the same CT volumetry method as CMRI can improve agreement with CMRI.

Evaluation of Left Atrial Appendage Isolation Using Cardiac MRI after Catheter Ablation of Atrial Fibrillation: Paradox of Appendage Reservoir

  • Hyungjoon Cho;Yongwon Cho;Jaemin Shim;Jong-il Choi;Young-Hoon Kim;Yu-Whan Oh;Sung Ho Hwang
    • Korean Journal of Radiology
    • /
    • 제22권4호
    • /
    • pp.525-534
    • /
    • 2021
  • Objective: To assess the effect of left atrial appendage (LAA) isolation on LAA emptying and left atrial (LA) function using cardiac MRI in patients who underwent successful catheter ablation of atrial fibrillation (AF). Materials and Methods: This retrospective study included 84 patients (mean age, 59 ± 10 years; 67 males) who underwent cardiac MRI after successful catheter ablation of AF. According to the electrical activity of LAA after catheter ablation, patients showed either LAA isolation or LAA normal activity. The LAA emptying phase (LAA-EP, in the systolic phase [SP] or diastolic phase), LAA emptying flux (LAA-EF, mL/s), and LA ejection fraction (LAEF, %) were evaluated by cardiac MRI. Results: Of the 84 patients, 61 (73%) and 23 (27%) patients showed LAA normal activity and LAA isolation, respectively. Incidence of LAA emptying in SP was significantly higher in LAA isolation (91% vs. 0%, p < 0.001) than in LAA normal activation. LAA-EF was significantly lower in LAA isolation (40.1 ± 16.2 mL/s vs. 80.2 ± 25.1 mL/s, p < 0.001) than in LAA normal activity. Furthermore, LAEF was significantly lower in LAA isolation (23.7% ± 11.2% vs. 31.1% ± 16.6%, p = 0.04) than in LAA normal activity. Multivariate analysis demonstrated that the LAA-EP was independent from LAEF (p = 0.01). Conclusion: LAA emptying in SP may be a critical characteristic of LAA isolation, and it may adversely affect the LAEF after catheter ablation of AF.

Prognostic Role of Right VentricularPulmonary Artery Coupling Assessed by TAPSE/PASP Ratio in Patients With Acute Heart Failure

  • Youngnam Bok;Ji-Yeon Kim;Jae-Hyeong Park
    • Journal of Cardiovascular Imaging
    • /
    • 제31권4호
    • /
    • pp.200-206
    • /
    • 2023
  • BACKGROUND: Right ventricular (RV) dysfunction is a significant risk of major adverse cardiac events in patients with acute heart failure (AHF). In this study, we evaluated RV-pulmonary artery (PA) coupling, assessed by tricuspid annular plane systolic excursion (TAPSE)/pulmonary artery systolic pressure (PASP) and assessed its prognostic significance, in AHF patients. METHODS: We measured the TAPSE/PASP ratio and analyzed its correlations with other echocardiographic parameters. Additionally, we assessed its prognostic role in AHF patients. RESULTS: A total of 1147 patients were included in the analysis (575 men, aged 70.81 ± 13.56 years). TAPSE/PASP ratio exhibited significant correlations with left ventricular (LV) ejection fraction(r = 0.243, p < 0.001), left atrial (LA) diameter(r = -0.320, p < 0.001), left atrial global longitudinal strain (LAGLS, r = 0.496, p < 0.001), mitral E/E' ratio(r = -0.337, p < 0.001), and right ventricular fractional area change (RVFAC, r = 0.496, p < 0.001). During the median follow-up duration of 29.0 months, a total of 387 patients (33.7%) died. In the univariate analysis, PASP, TAPSE, and TAPSE/PASP ratio were significant predictors of mortality. After the multivariate analysis, TAPSE/PASP ratio remained a statistically significant parameter for all-cause mortality (hazard ratio [HR], 0.453; p = 0.037) after adjusting for other parameters. In the receiver operating curve analysis, the optimal cut-off level of TAPSE/PASP ratio for predicting mortality was 0.33 (area under the curve = 0.576, p < 0.001), with a sensitivity of 65% and a specificity of 47%. TAPSE/PASP ratio < 0.33 was associated with an increased risk of mortality after adjusting for other variables (HR, 1.306; p = 0.025). CONCLUSIONS: In AHF patients, TAPSE/PASP ratio demonstrated significant associations with RVFAC, LA diameter and LAGLS. Moreover, a decreased TAPSE/PASP ratio < 0.33 was identified as a poor prognostic factor for mortality.

Clinical Midterm Results of Surgical Aortic Valve Replacement with Sutureless Valves

  • Soonchang Hong;Jung-Woo Son;Yungjin Yoon
    • Journal of Chest Surgery
    • /
    • 제57권3호
    • /
    • pp.255-262
    • /
    • 2024
  • Background: Sutureless aortic valves may enable shorter procedure times, which benefits patients with elevated surgical risk. We describe the outcomes of patients with aortic stenosis who underwent aortic valve replacement (AVR) using the sutureless Perceval aortic bioprosthesis. Methods: Data from a retrospective cohort were obtained from a clinical database. The study enrolled patients with symptomatic severe aortic stenosis who underwent surgical AVR with a sutureless bioprosthesis between August 2015 and December 2020. In total, 113 patients were included (mean age, 75.3±8.4 years; 57.5% women; median Society of Thoracic Surgeons score, 9.7%; mean follow-up period, 51.19±20.6 months). Of these patients, 41 were octogenarians (36.2%) and 3 were nonagenarians (2.6%). Transthoracic echocardiography was employed to assess changes in ejection fraction (EF), left ventricular mass index (LVMI), and mean pressure gradient (MPG). Results: The in-hospital mortality rate was 2.6%, and 13 patients developed new-onset atrial fibrillation. A permanent pacemaker was implanted in 3 patients (2.6%). The median intensive care unit stay was 1 day (interquartile range [IQR], 1-2 days), and the median hospital stay was 12 days (IQR, 9.5-15 days). The overall survival rate at 5 years was 95.9%. LVMI and MPG were reduced postoperatively, while EF increased over the follow-up period. No structural valve deterioration was observed, and no meaningful paravalvular leakage developed during follow-up. Conclusion: The use of a sutureless valve in the aortic position is safe and feasible, even for high-risk elderly patients requiring surgical AVR. LVMI and MPG decreased postoperatively, while EF increased over the follow-up period.

Aortic valve replacement through right anterior mini-thoracotomy in patients with chronic severe aortic regurgitation: a retrospective single-center study

  • Eun Yeung Jung;Ji Eun Im;Ho-Ki Min;Seok Soo Lee
    • Journal of Yeungnam Medical Science
    • /
    • 제41권3호
    • /
    • pp.213-219
    • /
    • 2024
  • Background: Aortic valve replacement (AVR) has recently been performed at many centers using a minimally invasive approach to reduce postoperative mortality, morbidity, and pain. Most previous reports on minimally invasive AVR (MiAVR) have mainly focused on aortic stenosis, and those exclusively dealing with aortic regurgitation (AR) are few. The purpose of this study was to investigate early surgical results and review our experience with patients with chronic severe AR who underwent AVR via right anterior mini-thoracotomy (RAT). Methods: Data were retrospectively collected in this single-center study. Eight patients who underwent RAT AVR between January 2020 and January 2024 were enrolled. Short-term outcomes, including the length of hospital stay, in-hospital mortality, postoperative complications, and echocardiographic data, were analyzed. Results: No in-hospital mortalities were observed. Postoperative atrial fibrillation occurred temporarily in three patients (37.5%). However, none required permanent pacemaker implantation or renal replacement therapy. The median values of ventilator time, length of intensive care unit stay, and hospital stay were 17 hours, 34.5 hours, and 9 days, respectively. Preoperative and postoperative measurements of left ventricular ejection fraction were similar. However, the left ventricular end systolic and diastolic diameters significantly decreased postoperatively from 42 mm to 35.5 mm (p=0.018) and 63 mm to 51 mm (p=0.012), respectively. Conclusion: MiAVR via RAT is a safe and reproducible procedure with acceptable morbidity and complication rates in patients with chronic severe AR. Despite some limitations such as a narrow surgical field and demanding learning curve, MiAVR is a competent method for AR.

조직판막을 이용한 대동맥판막치환술의 중기성적 (Midterm Results of Aortic Valve Replacement Using Tissue Valve)

  • 문덕환;이재원;김윤석;조원철;정성호;주석중;정철현
    • Journal of Chest Surgery
    • /
    • 제43권6호
    • /
    • pp.627-634
    • /
    • 2010
  • 배경: 조직판막의 내구성은 심장 판막 수술에서 기계판막과 조직판막을 선택하는 중요한 기준이 된다. 본 연구는 조직판막이 사용된 대동맥판막치환술의 중기성적을 분석해 보았다. 대상 및 방법: 이 연구는 1990년 3월부터 2009년 3월까지 조직판막을 이용하여 대동맥판막치환술을 시행한 380명의 환자들을 대상으로 하였다. 술 후 평균 관찰 기간은 $46.7{\pm}40.8$월(0~196개월)이었으며 외래 경과 기록과 의무기록을 통하여 후향적으로 분석하였다. 결과: 총 380명의 환자에서 389예의 수술이 시행되었으며 환자들의 평균 연령은 $69{\pm}9$세, 남녀 비는 227 : 162였다. 조기 사망은 15명 (3.9%)이었다. 1년, 5년, 10년 생존율은 92.3%, 78.1%, 54.2%였다. 재수술의 l년, 5년, 10년 회피율(Freedom from reoperation)은 98.4%, 97.1%, 91.7%였으며 구조적 판막 손상 1년, 5년, 10년의 회피율(Freedom from structural valvular deterioration)은 96.1%, 92.3%, 88.0%였다. 수술 전 위험인자의 다변량 분석에서 젊은 나이 (p<0.001)가 재수술의 위험인자였으며 수술 후 판막 부하 최고속도(p=0.034)와 젊은 나이(p=0.029)가 구조적 판막 손상의 위험인자였다. 고령(p=0.001), 장시간의 심폐기사용(long bypass time) (p=0.035), 관상동맥 우회술을 동시에 실시한 경우(concomitant CABG) (p=0.003), 술 전 중등도 이상의 좌심실 기 능부전(Left ventricular ejection fraction, LVEF<40%) (p=0.003)이 조기 사망의 위험인자였으며 술 전 신기능저하(estimated glomerular filtration rate, eGFR<60 mL/min) (p=0.025)와 지속적인 좌심실비대(persistent left ventricular hypertrophy, LVH) (p=0.032)가 만기 사망의 위험인자였다. 결론: 이 연구를 통해 조직판막을 이용한 대동맥판막치환술은 재수술과 구조적 판막 손상 회피율 등의 측면에서 만족할 만하다고 할 수 있으며, 향후 더 많은 환자에서 보다 장기적인 연구가 필요할 것으로 생각된다.

급성호흡곤란증후군 환자에 있어서 B-type Natriuretic Peptide의 유용성 (Utility of B-type Natriuretic Peptide in Patients with Acute Respiratory Distress Syndrome)

  • 이진국;주영빈;김석찬;박성학;이숙영;고윤석;김영균
    • Tuberculosis and Respiratory Diseases
    • /
    • 제62권5호
    • /
    • pp.389-397
    • /
    • 2007
  • 연구배경: B-type natriuretic peptide(BNP)는 심인성 및 다른 쇼크 상태를 포함하는 심혈관 질환에서 사망을 예측하는 좋은 인자 중의 하나로 알려져 있다. 그러나, 급성호흡곤란증후군환자에서 이런 관계가 잘 알려져 있지 않는 바, 저자들은 BNP가 급성호흡곤란증후군 환자에서 사망을 예측할 수 있는 지를 연구하였다. 방 법: 본 연구는 전향적 관찰로 시행되었다. 급성호흡곤란증후군으로 진단된 환자들에게 심초음파 검사를 시행한 후, 좌심실 구획률이 50% 미만이거나 확장성 심부전 양상을 보인 환자들을 제외하였다. 2003년 12월부터 2006년 2월까지 총 47명의 환자가 채택되었다. 등록된 환자들은 24시간 내로 BNP를 포함한 여러 검사실 수치를 얻었으며, APACHE(Acute Physiology and Chronic Health Evaluation) II 점수를 구하였다. 결 과: BNP와 APACHE II 점수 평균값은 생존자군과 사망자군에서 유의한 차의를 보였다(BNP: $219.5{\pm}57.7pg/mL$ vs $492.3{\pm}88.8pg/mL$; p=0.013, APACHE II 점수: $17.4{\pm}1.6$ vs $23.1{\pm}1.3$, p=0.009). BNP 는 혈중 크레아티닌 수치와 양의 상관관계를 보였으나(r=0.374, p=0.01), 좌심실 구획률과는 유의한 관계가 없었다. Receiver operating characteristic 곡선상, BNP 수치를 585 pg/mL로 잡았을 때 사망을 예측하는데 있어서 94%의 특이도를 보였으며, APACHE II 점수의 경우에는 15.5를 기준으로 하였을 때 87%의 민감도를 보였다. 이 두 요소를 결합하여 '아파치II 점수+$11{\times}logBNP$' 수치를 계산하여 기준점을 46.14로 했을 경우, 사망 예측에 있어서 민감도 63%, 특이도 82%의 결과를 얻을 수 있었다. 결 론: 좌심실 기능 부전을 보이지 않는 급성호흡곤란증후군 환자에서 BNP 수치는 생존자군과 사망자군에서 유의한 차이를 보였으며 사망을 예측할 수 있었다. 향후 급성호흡곤란증후군 환자에 있어서 BNP와 관련된 연구가 더 필요하다고 생각된다.

게이트 심근관류 SPECT를 이용한 심기능 분석: 정량분석 소프트웨어 QGS, 4D-MSPECT 및 심초음파법의 비교 (Analysis of Myocardial Function Using Gated Myocardial SPET : Comparison of QGS, 4D-MSPECT Software and Echocardiography)

  • 이석모;배상균
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권6호
    • /
    • pp.435-443
    • /
    • 2008
  • 목적 : 게이트 심근 관류 SPECT는 심근 관류 소견 뿐 아니라, 좌심실의 벽운동, 벽의 두꺼워짐, 좌심실 용적, 좌심실 박출율 등의 부가적인 정보를 제공한다. 심근영상에서 이들 정보를 얻기 위한 여러 가지 프로그램들이 제공되고 있다. 이 연구에서는 게이트 심근 관류 SPECT 분석 프로그램인 Quantitative Gated SPECT (QGS), 4D-MSPECT 소프트웨어를 이용하여 좌심실 박출율, 확장기말 좌심실 용적, 좌심근 질량을 구하고 이면성 심초음파검사를 통해 좌심실 박출율과 좌심근 질량을 구해 비교하였다. 대상 및 방법 : 핵의학과에 심근관류 SPECT 검사를 위해 의뢰되었던 환자 중 심근관류 SPECT에서 관류소견이 정상이었던 114명(남자51명, 여자 63명, 평균 $61.3{\pm}13.3$세, 29-85세)의 자료를 후향적으로 분석하였다. 게이트 심근 관류 SPECT는 이데노신 (0.14 mg/kg/min)을 6분간 부하하면서 Tc-99m Tetrofosmin (Myoview)을 주사하여 부하기 영상을 얻고, 4시간 후 휴식기 영상을 얻었다. Quantitative Gated SPECT (QGS), 4D-MSPECT 소프트웨어를 이용하여 좌심실 박출율, 확장기말 좌심실 용적, 좌심근질량을 구하고 이면성 심초음파검사를 이용하여 좌심실 박출율, 좌심근질량을 구하였다. 각 방법 사이의 상관계수를 구하고 Bland-Altman분석을 이용하여 변이의 범위를 분석하였다. 결과: 좌심실 박출율의 분석에서 QGS와 4D-MSPECT사이의 상관계수는 부하기/휴식기 각각 0.95/0.96로 강한 상관관계를 보였고, QGS와 심초음파 검사 사이의 상관계수는 0.79, 4D-MSPECT SPECT와 심초음파 검사 사이의 상관계수는 0.79로 좋은 상관관계를 보였다 (p<0.001). 확장기말 좌심실 용적의 경우 QGS와 4D-MSPECT SPECT 사이의 상관계수는 부하기/휴식기 모두 0.99로 강한 상관관계를 보였다(p<0.001). 좌심근 질량의 경우 QGS와 4D-MSPECT사이의 상관계수는 부하기/휴식기 각각 0.94/0.95로 강한 상관관계를 보였고, QGS와 심초음파 검사 사이의 상관계 수는 0.76, 4D-MSPECT SPECT와 심초음파 검사 사이의 상관계수는 0.73로 좋은 상관관계를 보였다(p<0.001). Bland-Altman 방법으로 분석하였을 때, 좌심실 박출율의 경우 QGS와 4D-MSFECT 검사 사이의 변이의 95% 신뢰구간은 부하기/휴식기 각각 $-12.7%\;{\sim}\;7.3%/-12.2%\;{\sim}\;6.5%$였고, QGS와 심초음파 검사의 경우 $-17.4%\;{\sim}\;24%$, 4D-MSPECT SPECT와 심초음파 검사 경우 $-14.8%\;{\sim}\;27%$였다. 확장기말 좌심실 용적의 경우 QGS와 4D-MSPECT검사 사이의 변이의 95% 신뢰구간은 부하기/휴식기 각각 $-24.6\;mL\;{\sim}\;3.8\;mL/-28.6\;mL\;{\sim}\;6.1\;mL$였다. 좌심근 질량의 경우 QGS와 4D-MSFECT 검사 사이의 변이의 95%신뢰간은 부하기/휴식기 각각 $-40.4\;g\;{\sim}\;14.4\;g$$-33.8\;g\;{\sim}\; 14.1\;g$이었고, QGS와 심초음파 검사 사이는 $-148.7\;g\;{\sim}\;21.8\;g$이었으며, 4D-MSPECT와 심초음파 검사 사이는 $-142.8\;g\;{\sim}\;35.5\;g$이었다. 결론: 좌심실 박출율, 확장기말 좌심실 용적, 좌심근 질량 등을 구하는 자동정량화 소프트웨어 QGS, 4D-MSPECT, 심초음파 검사(좌심실 박출율, 좌심근 질량) 상호간에 좋은 상관관계가 있었다. 하지만 Bland-Altman분석에서 QGS, 4D-MSPECT, 심초음파 검사간의 변이의 범위가 큰 편이어서 서로 바꾸어 사용할 수는 없었다.