• 제목/요약/키워드: Effluents

검색결과 453건 처리시간 0.024초

산업폐수의 생물독성 발현에 관한 연구 (Evaluation on Environmental Bio-toxicity of Industrial Wastewater)

  • 김상훈;천세억;신기식;정동일
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.274-276
    • /
    • 2005
  • To investigate bioassay for toxic level evaluation of wastewater, toxic levels were checked influents and effluents of 6 wastewater discharge facilities with Daphnia magna and Vibrio fischeri. In view of test duration, D. magna is preferred at 48 hours. And it was judged to efficient that one of the two was choosen for toxicity test method (Daphnia test and Vibrio test). Analysis data for wastewater is average toxic level for influent more higher than effluent. And effluent toxic level is sharp decrease than effluents.

물벼룩을 이용한 일부 염색폐수의 만성 수질독성 특성 연구 (Chronic Toxicities of Effluents from Dye Industry using Daphnia magna)

  • 김영희;이민정;어수미;유남종;이홍근;최경호
    • 환경생물
    • /
    • 제23권2호
    • /
    • pp.146-151
    • /
    • 2005
  • 본 연구를 통한 결론은 다음과 같다. 5개의 염색폐수배출업소에서 각각 3회씩 채취한 최종 방류수를 대상으로 한 생물독성시험 결과 미생물독성시험에서는 B시료와 E시료에서 독성이 관찰되었고 급성 물벼룩시험에서는 반수치사농도가 C시료에서만 관찰되어 염색폐수의 독성이 시험 생물종별로 다르게 나타날 수 있음을 제시하였다. 동일 생물종을 대상으로 실시한 급성 및 만성시험에서는 급성반수치사가 5개 방류수 중 C시료에서만 비교적 낮은 농도에서 관찰이 된 것에 비해 만성반수치사는 3개 방류수에서 나타났고 $EC_{50}$도 급성영향의 $1/2\~1/5$ 수준에서 결정되었다. 특히 만성노출에 의한 생식 및 성장에 미치는 영향은 치사에 미치는 영향농도보다 더 낮은 농도에서 나타나는 경향을 보이고 있다 따라서 방류수가 연속적으로 수계에 배출되는 특성을 고려하면 만성노출에 의한 영향을 평가하는 것이 중요한 의미를 갖는다. 한편 염색폐수의 경우 동일업종 또는 동일한 시료에서도 독성평가방법에 따라 서로 다른 정도의 독성이 관찰되는 등 독성발현이 매우 다양하게 나타났다. 그러므로 염색폐수가 수중생태계에 미치는 영향을 정확하게 파악하고 제어하기 위해서는 물고기나 조류 등 다른 영양단계에 있는 생물종에 미치는 영향 등의 연구가 요구된다.

유해원소로 오염된 토양 세척 및 세척수의 처리 (Soil Washing and Effluent Treatment for Contaminated Soil with Toxic Metals)

  • 양중석;황진민;백기태;권만재
    • Korean Chemical Engineering Research
    • /
    • 제51권6호
    • /
    • pp.745-754
    • /
    • 2013
  • 본 연구에서는 유해원소로 오염된 현장토양을 대상으로 물리적 및 화학적 토양세척공법을 적용하였을 경우, 유해원소의 처리효율과 더불어 토양세척공법에서 발생하는 폐수를 중화, 응집, 흡착 반응을 이용하여 처리할 경우를 고려하여 최적 토양세척공법의 선정방법을 평가하고자 하였다. 본 연구에서 사용한 토양에서 주된 유해원소인 비소제거에 수산화나트륨 수용액이 황산 수용액보다 효과적이었다. 반면, 폐수 처리의 경우 수산화나트륨 수용액으로 토양 세척 시 함께 추출되는 토양유기물로 인하여 폐수처리가 복잡하고 유해원소의 제거가 잘되지 않아 세척공정의 세척제로는 산을 이용하여 토양을 세척하는 것이 좋으며, 발생하는 세척액의 pH를 6.5 이상으로 중화시켜 대부분의 유해원소를 제거할 수 있었다. 흡착제로 GFO(Granular ferric oxide)를 이용하였을 경우 비소와 납의 제거율이 뛰어났으며, 중화공정과 결합하였을 경우 대부분의 유해원소를 제거할 수 있었다. 결과적으로, 토양세척 공법 적용 시 토양의 특성에 따라 유해원소의 제거율 및 세척액의 처리 및 재이용 방법이 차이가 있으므로, 세척효율 및 세척수 처리 공정을 고려한 체계적인 최적화를 진행하여야 할 것으로 판단된다.

비성층 해양방류수역에서의 하수플륨의 혼합구역 특성분석 (Mixing Zone Analysis of Outfall Plumes in Unstratified Oceanic Environment)

  • 강시환;박광순;오병철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.455-458
    • /
    • 2002
  • Mixing zone characteristics of the wastewater effluents discharged from an ocean outfall have been investigated using an outfall mixing zone analysis method. This analysis was applied to Sokcho ocean outfall case and was used to simulate the concentration distribution of wastewater effluents. Hourly concentration distributions of outfall effluent discharges were averaged for the period of 15 days. The results show that near-field dilution was relatively high with the dilution of 130 for the winter season.

  • PDF

고리원전의 온배수 방출이 주변 해조군집에 미치는 영향 (Effects of Heated Effluents on the Intertidal Macroalgal Community Near Gori Nuclear Power Plant)

  • 김영환;안중관;윤희동;장민아
    • ALGAE
    • /
    • 제22권4호
    • /
    • pp.297-304
    • /
    • 2007
  • This study is intended to clarify the effects of heated effluents on intertidal benthic marine algal community in Korea. The species composition and biomass of marine algae at the discharge canal of Gori nuclear power plant on the southeastern coast of Korea were investigated seasonally from February 2001 to October 2006. As a result, 54 species (7 blue-green, 12 green, 9 brown and 26 red algae) of marine algae were found at the discharge canal during the past six years. In general, the number of species observed was abundant during winter to spring and less in autumn. Enteromorpha compressa, E. intestinalis, E. prolifera and Caulacanthus ustulatus were common species found more than 80% frequency during the study period. Seasonal fluctuations of mean biomass were 1-440 g dry wt m–2 and dominant species in biomass were Enteromorpha spp. (contribution to a total biomass proportion 28%), Sargassum horneri (14%) and Amphiroa beauvoisii (14%). It is evident from the floristic composition and biomass data that unique micro-environment of the discharge canal support different communities from those on the intake or control area. Results from the large numbers of surveys before and during plant operation showed that, in the regions influenced by thermal effluents such as the discharge canal of power plants, the process of ecological succession has been proceeded. It is assumed that the uni-directional water flow and the time of overhaul largely affect the development and succession of benthic marine algal communities of the discharge canal.

Assessment of Water Pollution by the discharged water of the Abandended Mine

  • Kim, Hee-Joung;Yang, Jae-E.;Lee, Jai-Young;Park, Beang-Kil;Choi, Sang-Il;Jun, Sang-Ho
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.167-174
    • /
    • 2004
  • Several metalliferous and coal mines, including Myungjin, Seojin and Okdong located at the upper watershed of Okdong stream, were abandoned or closed since 1988 due to the mining industry promotion policy and thus disposed an enormous amount of mining wastes without a proper treatment facilities, resulting in water pollution in the downstream areas. AMD and waste effluents from the closed coal mines were very strongly acidic showing pH ranges of 2.7 to 4.5 and had a high level of total dissolved solid (TDS) showing the ranges of 1,030 to 1,947 mg/L. Also heavy metal concentrations in these samples such as Fe, Cu, Cd and anion such as sulfate were very high. These parameters of AMD and effluents were considered to be highly polluted as compared to those in the main stream area of the Okdong river and be major pollutants for water and soil in tile downstream area. Pollution indices of the surface water at the upper stream of Okdong river where AMD of the abandoned coal mines was flowed into main stream were in the ranges of 16.3 to 47.1. On the other hand, those at the mid stream where effluents from tailing dams and coal mines flowed into main stream were in tile ranges of 10.6 to 19.5. However, those at the lower stream were ranged from 10.6 to 14.9 These results indicated that mining wastes such as AMD and effluents from the closed mines were tile major source to water pollution at the Okdong stream areas.

  • PDF

하수처리장 방류수역에서 분변계스테롤과 노닐페놀류의 분포 특성 (Distribution of Fecal Sterols and Nonylphenolic Compounds in Sediments from Busan Suyeong Estuary, Impacted by Wastewater Treatment Plant Effluents)

  • 백승홍;윤세라;이인석;황동운;최민규
    • 한국수산과학회지
    • /
    • 제47권6호
    • /
    • pp.1006-1013
    • /
    • 2014
  • Wastewater organic compounds, that is, nonylphenolic compounds (NPs) and fecal sterols, were measured in surface sediments from Busan Suyeong Estuary, where two wastewater treatment plants (WWTPs) are located, to assess contamination from municipal effluents. The NPs analyzed were nonylphenol, and nonylphenol mono- and di-ethoxylates, all synthetic endocrine disruptors. The fecal sterols analyzed were coprostanol (COP), cholestanol, and epicoprostanol. Concentrations of NPs in the sediments ranged from 146 to 3,723 ng/g, and those of COP ranged from 366 to 13,018 ng/g. Their detection in all of the sediments analyzed indicates widespread pollution by municipal effluents. The highest concentrations of NPs and COP were detected at stations close to outfalls of WWTPs. Their levels in sediments are categorized in the higher range of those previously reported in Korean coastal areas. Moreover, in comparison with screening values of NPs in the Netherlands, Norway, and Canada, more than 50% of the sampling stations exceeded the guidelines. This indicates that the estuary may be adversely influenced by municipal effluents.

군산지역 용 . 폐수중의 THMs생성 및 배출에 관한 연구 (A Study on THMs Formation in Service Waters and Waste Waters at Kunsan)

  • 황갑수;이영남;김강주;여성구;김진삼
    • 한국환경보건학회지
    • /
    • 제27권4호
    • /
    • pp.41-46
    • /
    • 2001
  • Trihalomethane(THMs) levels in drinking tap water, indoor swimming pool water and industrial effluent in Kunsan area were surveyed in this study. During experimental period, the monthly averages of THMs in drinking tap water from Keumkang wide-area supply ranged from 15$\mu\textrm{g}$/ι/to 50 $\mu\textrm{g}$ showing the highest level in summer. 3 indoor swimming pools showed the monthly average levels of THMs formation ranging from 8$\mu\textrm{g}$/ι/to 20$\mu\textrm{g}$/ι and the pool under public management seemed to maintain its water quality more stable than those under private management THMs concentrations in the effluents. discharged from 10 manufacturing companies, ranged from N.D. to 95$\mu\textrm{g}$/ι and it was estimated that the overall THMs level discharged front those manufacturing companies is not high, reflecting the traces recorded for most effluents. The composition ratios of individual THMs for industrial effluents showed a difference from those for drinking water and swimming pool water, along with their wide variations according to the company and relatively high composition ratios of Br substituents.

  • PDF

하수처리장 방류수에서 TOC와 COD 유기물관리 (Management of TOC and COD Organic Matter of Effluents in Sewage Treatment Plants)

  • 황석호;박제철
    • 한국환경과학회지
    • /
    • 제27권4호
    • /
    • pp.261-266
    • /
    • 2018
  • In this study, the organic matter of effluents from sewage treatment plants, located in the Nakdong watershed was investigated. Regression equations were computed using treated sewage data to convert the chemical oxygen demand(COD) concentrations, which are mostly available from an open database, into total organic carbon(TOC) concentrations. The average concentration of organic matter in the sewage treatment plant effluents were 2.2~16.8 mg/L for COD and 3.4~14.3 mg/L for TOC. The concentrations of COD were positively correlated with the TOC concentrations. The correlation between COD and TOC was relatively high, at 0.865(p<0.01). Based on these results, regression analysis was conducted. The regression equation for TOC was $1.651{\times}COD_{Mn}-0.084$ ($R^2=0.84$). Furthermore, organic matter-related databases for more sewage treatment plants need to be built in order to establish TOC standards and manage the water quality.

우리나라 하수처리장 방류수 수질현황 및 특성 (Survey of the Secondary Effluents from Municipal Wastewater Treatment Plants in Korea)

  • 김영철;안익성;강민기
    • 한국물환경학회지
    • /
    • 제21권2호
    • /
    • pp.158-168
    • /
    • 2005
  • In this study, the discharging effluents from have been 9 municipal wastewater treatment plants surveyed for 1 year-period. Statistics including probability distribution, cumulative occurrence concentration and other statistical parameters were presented. In addition, treatment performance and its stability were also discussed. Most of the plants, have an operational problem of high soluble organic content in the secondary effluent which may be associated with the integrated treatment of human and livestock manures. Nitrogen concentration in the effluents were usually higher during the period of summer and winter. It was found that this is mainly due to lack of the proper C/N ratio during the summer, or/and the effects of low temperature and less dilution by dry weather during the winter. Phosphorus concentration is sharply increased in June. Discussion with plant operators told that it is due to the dissolution of phosphate from the sludge accumulated in the primary settling tanks from the early spring to june. During this period, usually, sludge treatment line is highly overloaded with flush-outs of the sediments also stored in the bottom of combined sewer due to the low flow during winter season. Most of the plants can meet new effluent discharge limits of the nitrogen and phosphorus, and total coliform without further treatment.