• Title/Summary/Keyword: Effluents

검색결과 451건 처리시간 0.025초

석유화학폐수 처리장 방류수의 재이용을 위한 고정생물막 공정에서 Fenton 산화전처리의 적응가능성 (Applicability of the lenten's Reagent Oxidation to Biological Fixed-Film Process for Reuse of Effluents from the Petrochemical Wastewster Effluent Treatment Plant)

  • 이규훈;김미화;박태주
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.115-115
    • /
    • 1995
  • Reuse of industrial effluents through the cooling systems in a petrochemical complex was described. The partial oxidation of the effluents from the biological treatment plant was examined, using Fenton''s reagent as a pretreatment step prior to a next treatment of the effluents. Next tertiary treatment using fixed-film reactor resulted in marked reductions in COD and suspended solids. The continuous fixed-film process with Fenton oxidation pretreatment showed a 23% increase in the COD removal efficiency when compared to that without pretreatment of Fenton oxidation under the volumetric organic loading rate of 0.1 kg COD/m3/day. The Fenton oxidation treatment seemed to be a possible method for tertiary biological treatment to reduce the residual toxicity with the enhanced biodegradation of the effluents.

석유화학폐수 처리장 방류수의 재이용을 위한 고정생물막 공정에서 Fenton 산화전처리의 적응가능성 (Applicability of the lenten류s Reagent Oxidation to Biological Fixed-Film Process for Reuse of Effluents from the Petrochemical Wastewster Effluent Treatment Plant)

  • 이규훈;김미화;박태주
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.501-508
    • /
    • 1995
  • Reuse of industrial effluents through the cooling systems in a petrochemical complex was described. The partial oxidation of the effluents from the biological treatment plant was examined, using Fenton's reagent as a pretreatment step prior to a next treatment of the effluents. Next tertiary treatment using fixed-film reactor resulted in marked reductions in COD and suspended solids. The continuous fixed-film process with Fenton oxidation pretreatment showed a 23% increase in the COD removal efficiency when compared to that without pretreatment of Fenton oxidation under the volumetric organic loading rate of 0.1 kg COD/m3/day. The Fenton oxidation treatment seemed to be a possible method for tertiary biological treatment to reduce the residual toxicity with the enhanced biodegradation of the effluents.

  • PDF

Toxicity characteristics of sewage treatment effluents and potential contribution of micropollutant residuals

  • Kim, Younghee;Farnazo, Danvir Mark
    • Journal of Ecology and Environment
    • /
    • 제41권11호
    • /
    • pp.318-327
    • /
    • 2017
  • Background: A typical sewage treatment plant is designed for organic and nutrient removal from municipal sewage water and not targeted to eliminate micropollutants such as pesticides, pharmaceuticals, and nano-sized metals which become a big concern for sustainable human and ecological system and are mainly discharged from sewage treatment plant. Therefore, despite contaminant removal by wastewater treatment processes, there are still remaining environmental risks by untreated pollutants in STP (sewage treatment plant) effluents. This study performed aquatic toxicity tests of raw wastewater and treated effluents in two sewage treatment plants to evaluate toxicity reduction by wastewater treatment process and analyze concentration of contaminants to reveal potential toxic factors in STP effluents. Methods: Water samples were collected from each treatment steps of two STPs, and acute and chronic toxicity tests were conducted following USEPA (United States Environmental Protection Agency) and OECD (Organization for Economic Cooperation and Development) guidelines. Endpoints were immobility for mortality and reproduction effect for estrogenicity. Results: Acute $EC_{50}s$ (median effective concentration) of influents for Seungki (SK) and Jungnang (JN) STPs are $54.13{\pm}32.64%$ and $30.38{\pm}24.96%$, respectively, and reduced to $96.49{\pm}7.84%$ and 100%. Acute toxicity reduction was clearly correlated with SS (suspended solids) concentration because of filter feeding characteristics of test organisms. Chronic toxicity tests revealed that lethal effect was reduced and low concentration of influents showed higher number of neonates. However, toxicity reduction was not related to nutrient removal. Fecundity effect positively increased in treated wastewater compared to that in raw wastewater, and no significant differences were observed compared to the control group in JN final effluent implying potential effects of estrogenic compounds in the STP effluents. Conclusions: Conventional wastewater treatment process reduced some organics and nutritional compounds from wastewater, and it results in toxicity reduction in lethal effect and positive reproductive effect but not showing correlation. Unknown estrogenic compounds could be a reason causing the increase of brood size. This study suggests that pharmaceutical residues and nanoparticles in STP effluents are one of the major micropollutants and underline as one of estrogenic effect factors.

대덕부지 원자력관련시설 운영에 따른 주민피폭선량 현황분석 (Radiological Dose Analysis to the Public Resulting from the Operation of Daedeok Nuclear Facilities)

  • 정해선;김은한;정효준;한문희;박미선;황원태
    • Journal of Radiation Protection and Research
    • /
    • 제39권1호
    • /
    • pp.38-45
    • /
    • 2014
  • 본 연구에서는 대덕 원자력부지에 위치한 원자력관계시설들에 의한 방사선환경의 안전성을 확인하기 위해, 기체상 및 액체상 유출물에 의한 주민선량평가를 수행하였다. 이를 위해 2010년부터 2012년까지의 3년간 대덕부지의 기상자료 및 환경으로 방출된 선원항 자료를 기반으로 하여 개인 최대피폭선량을 평가, 분석하였다. 기체상 유출물의 대기확산 인자 및 침적인자는 XOQDOQ 전산코드를 이용하여 계산하였다. 기체상과 액체상 방사성물질의 방출에 의한 최대개인선량(이하 개인선량)계산은 각각 ENDOS-G와 ENDOS-L 코드를 사용하였고, 원자력안전위원회 고시 제 2012-29에 제시된 부지당 연간기준치와 비교하였다. 최대피폭지점에서의 개인의 유효선량과 갑상선선량을 계산하였고, 이에 대한 피폭영향에 미치는 기여도를 분석하였다. 그 결과, 최대 피폭연령군은 소아로 평가되었으며 하나로 운영에 의한 영향이 90% 이상 지배적인 것으로 나타났다. 또한 기체상유출물에 의한 주요피폭경로는 섭취와 호흡에 의한 것이며, 유효선량에는 삼중수소가, 갑상선 등가선량에는 방사성옥소가 가장 영향을 많이 미치는 것으로 분석되었다. 선량평가시 기체상유출물이 90% 이상 기여하였고 액체상유출물에 의한 기여도는 상대적으로 낮은 것으로 나타났다. 결과적으로, 대덕부지의 원자력관계시설들에 의한 부지 내 개인선량은 최대 기준치의 3% 이내로 평가되어 환경에 미치는 영향이 매우 적은 것으로 확인되었다.

육수의 영향을 받는 완도 및 고금도 북부 해역의 해황 특성 (Physical Marine Environment at the north of Wando and Gogeumdo Receiving the Effluents from Land)

  • 이문옥;박일흠
    • 한국환경과학회지
    • /
    • 제15권1호
    • /
    • pp.45-58
    • /
    • 2006
  • In order to grasp physical characteristics of Ganajin Bay receiving the effluents from land, a comprehensive field surve)'has been conducted at the north of Wando and Gogeumdo in 2002. Water temperature was most high in September while most low in December. A high temperature in September was inferred to have caused by the dispersion of warm fresh water with favor of a dominant wind in autumn. However, salinity and sigma-t in situ was most low in September while most high in December. A low salinity (or density) in September turned out to reflect the influence of a dense rainfall in summer. Water temperature, salinity and density at the surface layer were lower than those at the bottom layer, except for December. Their horizontal profiles suggested the influence of effluents such as Tamjin River. Particularly, time series of water temperature acquired near the sluice and at the north channel of Wando tended to rise at the flood flow but fall at the ebb flow in accordance with the tide. The form ratio of the tide in the study area was $0.31\~0.32$ and the amplitude of the tide appeared to increase towards the west. Northeastward or southwestward flows prevailed in this area but the residual flows were all northeastward with a magnitude of $3\~4cm/s$.

낙동강 수계 하.폐수 처리시설의 방류수가 조류 성장 잠재력에 미치는 영향 (Effect of the Sewage and Wastewater Plant Effluent on the Algal Growth Potential in the Nakdong River Basin)

  • 서정관;이재정;양상용;정익교
    • ALGAE
    • /
    • 제18권2호
    • /
    • pp.157-167
    • /
    • 2003
  • Effect of the effluent of the sewage and wastewater plants on the algal growth was investigated from the 19 plants located in the Nakdong river basin. Most of the samples showed high values of the algal growth potential (AGP) when they were mixed with natural river water at 20% of final concentration. At 20% of the mixing ratio, the mixed effluents of sewage and wastewater showed 3.5 and 1.8 times higher AGP than those of the natural river water. The higher AGP values are attributable to the high contents of phosphorus and ammonium in the effluent. The mixing ratio of effluents of the discharge/river flow was highest in the Kumho River (42.8%) followed by the middle of Nakdong River (22.7%), Kam Stream (13.9%), Byungsung Stream (13.3%), Yangsan Stream (7.9%), and Young River (5.4%). Comparison of the trophic state of the effluents with natural river water indicated that the effluents showed higher trophic values than natural water. Concentrations of total phosphorus, total nitrogen and conductivity in the effluents were 12.3, 4.9 and 5.3 times higher than the those found in natural river water respectively. The AGP values were highly related with the trophicity of the water especially on the concentrations of phosphate and ammonium. Toxicities of the treated sewage water, wastewater and livestock waste water tested by the luminescent bacteria, Vibrio fischerii were generally low.

영산강유역 생활하수처리장 방류수에서의 유기오염물질 분포특성에 관한 연구 (A Study on the Distribution Property of Organic Pollutants in Effluents from Domestic Sewage Treatment Plants Throughout Youngsan River)

  • 이문희;이종삼;한상국
    • 대한환경공학회지
    • /
    • 제27권12호
    • /
    • pp.1332-1339
    • /
    • 2005
  • 본 연구의 목적은 310종 다성분 동시분석법을 이용하여 영산강유역 생활하수처리장 방류수에서 유기오염물질의 분포특성을 연구하는 것이다. 그 결과, 5개 시료채취지점에서 많은 유기오염물질이 검출되었고 그 중 농약류, CH구조의 벤젠류와 다환방향족화합물 그리고 CHO구조의 페놀류와 프탈레이트류 화합물이 주요오염물질로서 검출되었다. 특히, 14종의 농약류가 주로 여름철에 방류수에서 검출되었다. 1-Chlorobenzen과 p-octylphenol은 각각 $0.52{\sim}0.61\;{\mu}g/L$$0.04{\sim}0.89\;{\mu}g/L$ 농도범위를 가지고 빈번히 검출되는 오염물질이다. 또한, 5개 시료채취지점에서 diethylphthalate를 포함한 18종의 내분비계교란물질이 관찰되었다. 따라서 이러한 연구결과로부터 우리는 영산강유역 생활하수처리장 방류수에서 농약류와 CH, CHO구조를 가진 화학물질들에 대해 특별 관리가 이루어져야 한다고 생각한다.

통계적 방법을 이용한 방사성 물질의 해양 확산 평가 (A Study on the Oceanic Diffusion of Liquid Radioactive Effluents based on the Statistical Method)

  • 김숭평;이경진
    • Journal of Radiation Protection and Research
    • /
    • 제23권1호
    • /
    • pp.1-6
    • /
    • 1998
  • 영광 원전 지역에 적용될 수 있는 액체 방사성 물질의 확산 모델을 개발하였다. 영광에서의 해양 확산 조건은 매우 복잡하기 때문에 수치적 모델을 적용하는 것은 매우 어렵다. 따라서 비교적 단순하면서도 신뢰성 있는 미규제 지침 1.113에서 제시한 통계적 모델을 적용하였다. 이를 통해, 발전소 운전 조건이나, 피폭 경로에 따른 희석 인자를 계산할 수 있는 컴퓨터 코드를 개발하였다. 액체 방사성 물질의 확산에 대해서, 혼합 범위에 따라 근거리 혼합 모델과 원거리 혼합 모델로 구분하여 모델을 개발하였다. 근거리 혼합 현상은 부력과 초기 운동량 및 난류에 의해 결정된다. 원거리 혼합에서는 대기 중의 구름 확산과 유사하게 가우시안푸륨 모델을 적용할 수 있다. 서로 다른 피폭 경로에 대해 물리적으로 타당한 적분을 수행함으로서, 경로에 따른 희석 인자를 구할 수 있었다. 개발된 모델을 사용하여 계산한 결과에 의하면, 현행 영광 ODCM에 사용되는 희석 인자는 상당히 과평가되어 있음을 알 수 있다.

  • PDF

간접방류사업장 관련 폐수의 생태독성수준 및 특성 평가 (Evaluation of Ecotoxicity and Characteristics on Indirect Effluents and Related Wastewater)

  • 김종민;신기식;이수형;이정서;이택준
    • 한국물환경학회지
    • /
    • 제33권4호
    • /
    • pp.481-486
    • /
    • 2017
  • This paper aims to evaluate the characteristics of direct and indirect effluents'toxicity level and difference between two test durations (24 h and 48 h) of test method. The proportion of the indirect effluent samples which exceeded the ecotoxicity permit limitations (TU 1 or TU 2) showed more than 2 times higher than that of direct effluent samples. However, effluent toxicity of Wastewater Treatment Plants (WTPs) indicated less than TU 1 regardless of influent toxicity. From this results, treatment process was thought to have a good efficiency. WTP Salinity was very similar between influent and effluent. This trend could be reconfirmed by the component ratio of ion concentration between them and $Na^+$, $SO_4^{2-}$, $C^-$ lions which have a greater percentage than other ions. In addition, in case of high salinity, toxicity value also showed high level. To judge from above results, indirect effluents which were exempted from application of ecotoxicity standards, may need a new effluent limitations regardless of the treatment efficiency of WTP. According to circumstances, effective countermeasure may need to restrain the discharge of salinity-contained effluents which came from indirect-effluent factories. Test duration comparative study indicated that 48 h results were higher toxicity (exceeding rate of ecotoxicity criteria) than 24 h by the 5 to 5.4 percentage. 24 h test duration seemed to be useful in case of rapid detection, whereas 48 h test method could be applied for reinforcement of ecotoxicity regulatory system.

Reuses Of Wash Water Effluents Of The Ion-Exchanger Units Of Water Demineralization Plant For Economic And Environmental Benefits

  • Miah, Raisuddin
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.799-806
    • /
    • 1995
  • In industrial field, a large volume of regenerants (acid and caustic soda) and their washing effluents are regularly disposed off from the water demineralization plant during regeneration of the ion-exchanger units. Of these waste effluents, a part of the wash water discharged from the single bed Anion and Mixed Bed units can be utilized at a certain stage of their washing cycles when its conductivity is fallen down and becomes considerably less than that of the input raw water. The main aim of this specific waste effluent utilization is to dilute the TDS concentration of the input raw water (fed into the single bed ion-exchanger units) by blending. The achievement is the increase of the longevity of the production cycles of the I.E. units along with the improvement of the production quality and decrease of the regeneration frequencies. As a result, regenerant consumption would be saved because of the reduction of ionic load in feed water which will ultimately reduce the water purification cost. At the same time, the environment pollution will also be protected to a considerable extent. This operational measure is quite effective and useful specially where high TDS water is demineralized only by single bed ion-exchangers. In such case, the water treatment plant is very often found to suffer from both production quality and quantity in addition to carrying out of random and restless regenerations. Proper reuses of the aforesaid wash water effluents of the Anion and MB units excellently minimizes the difficulties experienced in practice. This paper contains the utilities and techniques of reuses of the different kinds of waste effluents of the industrial water treatment plant in addition to the specific reuses of the post-regeneration wash waters of the Anion and MB ion-exchanger units.

  • PDF