• 제목/요약/키워드: Effluent standard

검색결과 187건 처리시간 0.033초

한국의 호수 수질관리의 문제점 (Problems of lake water management in Korea)

  • 김범철;전만식;김윤희
    • 한국환경생태학회:학술대회논문집
    • /
    • 한국환경생태학회 2003년도 추계학술논문발표회 논문집
    • /
    • pp.105-126
    • /
    • 2003
  • In Korea most of annual rainfall is concentrated in several episodic heavy rains during the season of summer monsoon and typhoon. Because of uneven rainfall distribution many dams have been constructed in order to secure water supply in dry seasons. The Han River system has the most dams among Korean rivers, and the river is a series of dams now. Reservoirs need different strategy of water quality control from river water. Autochthonous organic matter and phosphorus should be the major target to be controlled in lakes. In this Paper some problems are discussed that makes efforts of water quality improvement ineffective in lakes of Korea, even after the substantial investment to wastewater treatment facilities.1) Phosphorus is the key factor controlling eutrophication of lakes and the reduction ofphosphors should be the major target of water treatment. However, water quality management strategy in Korea is still stream-oriented, and focused on BOD removal from sewage. Phosphorus removal efficiency remains as low as 10-30%, because biological treatment is adopted for both secondary treatment and advanced treatment. The standard for TP concentration of the sewage treatment plant effluent is 6 mgP/l in most of regions, and 2 mg/l in enforced region near metropolitan water intake point. TP in the effluents of sewage treatment plants are usually 1-2 mg/1, and most of plants meet the effluent regulation without a further phosphorus removal process. The generous TP standard for effluents discourages further efforts to improve phosphorus removal efficiency of sewage treatment. Considering that TP standard for the effluent is below 0.1 mg/l in some countries, it should be amended to below 0.1 mg/l in Korea, especially in the watershed of large lakes.2) Urban runoff and combined sewer overflow are not treated, even though their total loading into lakes can be comparable to municipal sewage discharges on dry days. Chemical coagulation and rapid settling might be the solution to urban runoff in regard of intermittent operation on only rainy days.3) Aggregated precipitation in Korea that is concentrated on several episodic heavyrains per year causes a large amount of nonpoint source pollution loading into lakes. It makes the treatment of nonpoint source discharge by methods of other countries of even rain pattern, such as retention pond or artificial wetland, impractical in Korea.4) The application rate of fertilizers in Korea is ten times as high as the average ofOECD countries. The total manure discharge from animal farming is thought to be over the capacity of soil treatment in Korea. Even though large portion of manure is composted for organic fertilizer, a lot of nutrients and organic matter emanates from organic compost. The reduction of application rate and discharge rate of phosphorus from agricultural fields should be encouraged by incentives and regulations.5) There is a lot of vegetable fields with high slopes in the upstream region of the HanRiver. Soil erosion is severe due to high slopes, and fertilizer is discharged in the form of adsorbed phosphorus on clay surface. The reduction of soil erosion in the upland area should be the major preventive policy for eutrophication. Uplands of high slope must be recovered to forest, and eroded gullies should be reformed into grass-buffered natural streams which are wider and resistant to bank erosion.

  • PDF

화학적 폐수처리 중 GC/MS에 의한 폐놀생성 규명에 관한 연구 (A Study on the Identification of Phenol Production by GC/MS under Chemical Treatment of Industrial Wastewater)

  • 박선구;고오석;신대윤
    • 한국환경과학회지
    • /
    • 제9권1호
    • /
    • pp.89-93
    • /
    • 2000
  • Twenty organic chemical substances(Table 2) were isolated from untreated wastewater, as well as treated wastewater, collected at 76 companys of 9 industry group located in the basin of Youngsan River. Those organic compounds were analyzed by Gas Chromatography/Mass Spectrometry(GC/MS) and confirmed through comparison with each standard reagents. Phenol, which was not detected in the raw wastewater, was identified in the effluent of treatment facility, indicating that phenol is generated from isopropylbenzene of plant wastewater.

  • PDF

바이오산업폐수처리수의 재이용을 위한 hybrid 인공습지 시스템의 적용가능성 연구 (Application of the Hybrid Constructed Wetland for a Reuse of the Effluent from Bio-industrial Wastewater Treatment Plant)

  • 신재석;김성철;조광주;최충호;최인욱;박정자;박구현
    • 한국습지학회지
    • /
    • 제11권1호
    • /
    • pp.115-121
    • /
    • 2009
  • 생물산업 연구단지에서 발생되는 폐수를 처리하기 위해 건설된 폐수처리장의 3차 처리시설로 hybrid 인 공습지 시스템을 적용하여 최종 방류수의 재이용가능성을 평가하였다. 폐수처리를 위한 1차 처리공정은 화학적 처리(약품 응집)이며, 2차 처리공정은 생물학적 처리(표준활성슬러지법)로 구성되어 있다. 3차 처리시설로서 hybrid 인공습지는 자연통풍시스템이 구비된 호기성 인공습지와 혐기/무산소성 인공습지가 순차적으로 연결된 시스템이다. Hybrid 인공습지로 유입되는 2차 생물학적 처리공정의 처리수 농도는 BOD, SS, T-N 및 T-P의 평균 농도가 각각 53mg/L, 48mg/L, 34mg/L 및 3mg/L로 나타났으며, hybrid 인공습지에서의 최종방류수의 BOD, SS, T-N 및 T-P의 평균농도는 각각 2.3mg/L, 1.2mg/L, 7.95mg/L 및 0.83mg/L로 나타나 하수처리수의 재이용권고수질기준과 비교할 때 조경용수나 세척용수 등의 용도로 직접 재이용이 가능한 수질이 확보될 수 있었다. Hybrid 인공습지는 반응조를 호기 및 혐기/무산소 조건으로 기능화 함으로서 높은 효율로 오염물질이 제거될 수 있었으며, 이러한 결과로부터 다양한 하수 및 폐수의 3차 처리시설로서 활용이 가능한 것으로 평가되었다.

  • PDF

J 하수 처리장 방류수 중 세균의 성장 거동 및 염소 소독 효율 고찰 (Study on Microorganism Multiplication Behavior and Efficiency of Chlorine Disinfection in the Sewage Effluent from J Municipal Waste Water Treatment Plant)

  • 이운기;이윤진;정규연
    • 공업화학
    • /
    • 제19권1호
    • /
    • pp.122-128
    • /
    • 2008
  • 본 연구에서는 J 하수 처리장의 최종 방류수를 대상으로 종속영양세균의 증식과 수중 물리, 화학적 영향인자와의 관계를 고찰하였다. 하수 중의 용존 유기물질 농도는 종속영양세균의 성장과 가장 밀접한 관계를 보였다. 미생물의 영양원인 단백질, 지방, 전분, 섬유소, 팩틴의 분해 세균 분포를 파악한 결과 하수 중 단백질 및 지방세균의 비율은 전체의 81%로 가장 높았다. 종속영양세균은 연중 8월에 가장 높은 수치를 나타냈다. 하수 방류수에 대해 10 mg/L의 유리염소를 주입하여 15 min간 접촉시 THMs의 농도는 $71{\mu}/L$ (< $100{\mu}/L$- 먹는 물 수질기준)의 값을 나타내어 높지 않았다.

GPS-X 시뮬레이션을 이용한 2단탈질 공정에서 외부탄소원 적용성 평가 (Evaluation of External Carbon Source on the 2 Stage Denitrification Process by Simulation of GPS-X)

  • 정창화;심유섭;김태형;박철휘
    • 상하수도학회지
    • /
    • 제18권1호
    • /
    • pp.37-48
    • /
    • 2004
  • The purpose of this study was to evaluate adaptability of external carbon source using GPS-X program in pilot plant composed with 2-stage denitrification process. The result from analysis of pilot plant operation and GPS-X simulation showed that effluent concentration could be simulated similarly by modifying operation conditions, such as DO concentration, C/N ratio and other calibrated parameter. In order to satisfy the standard of the effluent water quality on T-N of 20mg/L, it required approximately 3.1 of C/N ratio and 50% of nitrogen removal efficiency when influent T-N is 36.9mg/L. To maintain the stable water quality of the receiving water, the effluent T-N concentration should be less than 10-15mg/L and the appropriate C/N ratio to remove nitrogen was 4.27-6.82. The analysis of sensitivity to kinetic coefficient and reaction constant showed that $Y_H$ and ${\mu}_{mAUT}$ were most sensitive to nitrate and ammonia nitrogen, relatively and sensitivity coefficient of their were 1.32, 1.98. It was concluded that as $Y_H$ decreased and ${\mu}_{mAUT}$ increased, the reaction rates of denitrification and nitrification increased and the removal efficiencies of $NO_3{^-}-N$ and $NH_4{^+}-N$ improved.

하천수를 정화하는 자유수면습지의 식물 성장기와 비성장기의 질소제거 비교 (Comparison of Nitrogen Removal During Plant Growing Season with Non-Growing One in Free Water Surface Wetlands Purifying Stream Water)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제13권1호
    • /
    • pp.82-92
    • /
    • 2010
  • Removal rates of NO3-N and TN in a free water surface wetland system during emergent plant growing season and non-growing were investigated. The system was established on floodplain in the down reach of the Gwangju Stream in 2008. Its dimensions were 46 meters in length and 5 meters in width. Typha angustifloria L. growing in pots about two years were planted on the half area of the system and Zizania latifolia Turcz on the other half. Water of the stream was funneled into it by gravity flow and its effluent was discharged back into it. Volumes and water quality of inflow and outflow were analyzed from October 2008 to September 2009. Inflow into the system averaged approximately 715 $m^3$/day and hydraulic residence time was about 1.5 hr. Average influent and effluent $NO_3$-N concentration was 3.37 and 2.74 mg/L, respectively and $NO_3$-N retention amounted to 18.7%. Influent and effluent TN concentration averaged 4.67 and 3.69 mg/L, respectively and TN abatement reached to 20.9%. $NO_3$-N removal rate (%) during plant growing season ($22.67{\pm}3.70$, mean ${\pm}$ standard error) was significantly high (p<0.001) when compared with that during plant non-growing one ($15.02{\pm}3.23$). TN abatement rate (%) during plant growing season ($27.42{\pm}5.98$) was also significantly high (p<0.001) when compared with that during plant non-growing one ($13.66{\pm}3.08$).

유기폐자원을 이용한 고도하수처리 대체탄소원 개발 및 실플랜트 적용 (Development of Alternative External Carbon Source from Wasting Carbonaceous Organic Resource and Full Scale Application)

  • 정인철;김호영;강동효;정종순;이상원;임근택;김창원
    • 한국환경과학회지
    • /
    • 제13권10호
    • /
    • pp.911-919
    • /
    • 2004
  • The purpose of this research was evaluated economical effect to apply alternative external carbon source. Conventional activated sludge process in municipal wastewater treatment plant was adapted and introduced to Biological nutrient removal processes to meet the newly enforced effluent quality standard for nutrient removal in Korea. Low $COD/NH_4^+-N$ ratio and higher nutrient concentration of influent characteristics force to inject external carbon source for denitrifying recycled nitrate. In the most case, methanol was used as external carbon source. But Methanol is expensive and very dangerous in handling. So we could find cheaper and safer external carbon source substituted methanol in last study. This alternative external carbon source is named RCS(recoverd carbon source) and a by-product of fine chemical product at chemical plant. When RCS was applied real municipal wastewater treatment plant, average $55\~65\%$ of T-N removal efficiency, 8.8mg/l of effluent T-N concentration, 11.3mg/l of effleunt COD concentration were obtained without effluent COD increase as against used methanol. To apply RCS in municipal wastewater treatment plant obtain approximately $\74.5%$ expenditure cost reduction in comparison with methanol dosage cost.

하수처리시설에서 총유기탄소(TOC) 처리를 위한 운영·관리 고찰 (A study on operation and management for TOC removal of public sewage treatment works)

  • 정동환;정현미;조양석;김은석;김창수;박준원;이원석
    • 상하수도학회지
    • /
    • 제32권6호
    • /
    • pp.535-550
    • /
    • 2018
  • Total organic carbon (TOC) will replace chemical oxygen demand ($COD_{Mn}$) as an effluent water quality standard in public sewage treatment works (PSTWs) from 2021 in Korea. To ensure effective control of TOC in the effluent, investigation was carried out into TOC levels and sewage treatment operation factors in five target PSTWs using anaerobic-anoxic-aerobic ($A_2O$) processes, media, membrane, and sequencing batch reactor (SBR) technologies. TOC removal efficiencies appeared to be 93-96% on average. As a fraction of TOC, biodegradable dissolved organic carbon (BDOC) was reduced from 64% in the influent to 9% in the effluent in these PSTWs. During the investigation, biological treatment processes were applied flexibly for operation factors such as HRT, SRT, MLSS, F/M ratios and BOD volume loads, based on the influent characteristics and design conditions. As a result, we suggest efficient operating conditions in PSTWs by evaluating relationships between TOC removal and operation factors.

입상여과에서 입자물질의 부착 (Particle Attachment in Granular Media Filtration)

  • 김진근
    • 상하수도학회지
    • /
    • 제18권5호
    • /
    • pp.666-672
    • /
    • 2004
  • Granular media filtration is used almost universally as the last particle removal process in conventional water treatment plants. Therefore, superb particle removal efficiency is needed during this process to ensure a high quality of drinking water. However, every particle can not be removed during granular media filtration. Besides the pattern of particle attachment is different depending on physicochemical aspects of particles and suspension. Filtration experiments were performed in a laboratory-scale filter using spherical glass beads with a diameter of 0.55 mm as collectors. A single type of particle suspension (Min-U-Sil 5) and pH control was used to destabilize particles. The operating conditions were similar to those of standard media filtration practice: a filtration velocity of 5 m/h. More favorable particles, i.e., particles with smaller surface charge, were well attached to the collectors especially during the early stage of filtration. This selective attachment of the lower charged particles caused the zeta potential distribution (ZPD) of the effluent to move to a more negative range. On the other hand, the ZPD of the effluent did not keep moving from less negative to more negative during the later stages of filtration, and this result was thought to be caused by two reasons: ripening effects and the detachment of flocs.

과실 채소중 잔류농약(유기인제)에 관한 연구 (Organophosphorus Insecticide Residues in Fruits and Vegetables)

  • 윤숙자
    • 환경위생공학
    • /
    • 제5권1호
    • /
    • pp.83-92
    • /
    • 1990
  • Adapting two step aeration system to a waste water treatment of W-paper manufactory as Full-Scale Plants, we drew a following conclusion from its practical working. 1. Because BOD removal efficiency was 20% in A-Stage, 90% in B-Stage and total removal efficiency was 97%. It worked treatment plant well and was suitable for effluent water standard as well. Because COD removal efficiency was 42% in A-stage, 71% in B-stage and the total removal efficiency was 94% COD control was possible in effluent water quality. 2. Treatment efficiency according to a load capacity was average 20% in 1.401 BOD kg/m3/d load of A-Stage and average 90% in 0.273 BOD kg/$\textrm {m}^3$ / d load of B-Stage. 3. Treatment efficiency according to a ratio of F/M was 2.657--5.024 kg BOD/kg MLSS/d in A-Stage and BOD removal efficiency was 16-261 in the same stage. The ratio of F/M was 0.068-0.094 kg BOD /kg MLSS/d and BOD removal efficiency ratio was 85-94%. Therefore treatment efficiency could be kept stably and volume of aeration tank could be reduced wholly. 4. Treatment efficiency according to MLSS appeared BOD 20%. COD 42%, in A-Stage and removal efficiency appeared BOD 90%, COD 71% in B-Stage. They were suitable for plan condition. 5. Because of working of complemented treatment plant by AB-Process. 20,000,000 Won a month was saved than the ordinary working cost. Therefore, it was assumed that invested cost could be recollected in 19 months or so consequently.

  • PDF