• 제목/요약/키워드: Effluent standard

검색결과 187건 처리시간 0.025초

산업폐수에 대한 이화학적 분석과 물벼룩 생태독성의 비교 (Comparison between Ecotoxicity using Daphnia magna and Physiochemical Analyses of Industrial Effluent)

  • 이선희;이학성
    • 한국환경과학회지
    • /
    • 제23권7호
    • /
    • pp.1269-1275
    • /
    • 2014
  • Ecotoxicity assessments with the physiochemical water quality items and the bioassay test using Daphnia magna were conducted for 18 selected effluents of 6 industrial types (metal processing, petroleum refining, synthetic textile manufacturing, plating, alcohol beverage manufacturing, inorganic compound manufacturing) being detected toxicity from industrial effluent in Ulsan city, and the interrelationship between total toxic unit (${\Sigma}TU$) and concentrations of Water Quality Conservation Act in Korea were investigated. The average toxic unit(TU) of effluents for 6 industrial types displayed the following ascending order: petroleum refining (0.2) < synthetic textile manufacturing (0.6) < alcohol beverage manufacturing (0.9) < metal processing (1.3) ${\leq}$ inorganic compound manufacturing (1.3) < plating (3.0). These values were less than effluent permission standard. Based on the result of substances causing ecotoxicity, the correlation analysis was not easy because most of heavy metals were not detected or were less than effluent permission standard. Toxicological assessment of industrial effluent was suitable for the evaluation of the mixture toxicity for pollutant. The whole effluent toxicity test using a variety of species was needed for the evaluation of industrial wastewater.

하수처리시설의 T-N 방류수 수질기준 강화방안에 관한 연구 (A Study on Strengthening Option of T-N Effluent Water Quality Standards of Sewage Treatment Plants)

  • 김지태
    • 한국물환경학회지
    • /
    • 제34권2호
    • /
    • pp.216-225
    • /
    • 2018
  • Over the past 40 years, the public sector has continued to invest in the sewage treatment plants (STPs) in Korea. Currently, the domestic sewage treatment rate is over 90% with the enhancement of operating efficiency of the STPs, and water quality of major rivers has been continuously improved. However, COD and T-N indicators are stagnating or slightly worsening, and though advanced treatment facilities are installed in most of the STPs, there is a limit to the removal of nutrients. Since there are a lot of water pollution sources in the vicinity of the watershed because of high population density in Korea, it is essential to reduce the inflow of the nutrients in order to prevent the eutrophication of the rivers and lakes. While the effluent T-P standard in STPs has greatly strengthened since 2012, which results in the considerable investment for the improvement of treatment process in STPs for the last few years, it is necessary to strengthen the T-N standards, as the effluent standard of T-N has been maintained at 20 mg/L since 2002. In this study, based on the analysis of the effluent T-N standard status of major industrialized countries, and the domestic nitrogen load in public waters, the option of appropriate T-N standard level is reviewed, and the required investment costs and the effect of strengthening the standard are estimated.

인공습지의 농촌지역 오수정화시설에 적용가능성 연구 (Feasibility Study of Constructed Wetland for the Wastewater Treatment in Rural Area)

  • 윤춘경;권순국;권태영
    • 한국농공학회지
    • /
    • 제40권3호
    • /
    • pp.83-92
    • /
    • 1998
  • Field experiment was performed from August 1996 to January 1998 to examine the applicability of constructed wetland system for wastewater treatment in rural area. The pilot plant was installed in Kon-Kuk University and the school building septic tank effluent was used as an influent to the treatment basin. Hydraulic loading rate was about 0.1 6$0.16^3/m^2$ day and theoretical detention time in the system was 1.38 days. The treatment basin was composed of sand and reed. The influent DO concentration was low and many cases close to zero, but effluent concentration was higher than the influent which implies that oxygen was supplied naturally. The average concentration of influent BOD was 126mg/L, and with average removal rate of 69 % the average effluent concentration was 4Omg/L which satisfied the effluent water quality standard for the system of interest. The average influent concentration of COD was 2Olmg/L and average effluent concentration was 75mg/L with average removal rate of 60%. The performance of BOD and COD tends to deteriorate in the low temperature, and appropriate action needs to be taken during the cold winter time for stable operation. The average influent concentration of SS was 5Omg/L, and effluent was 1 1mg/L with average removal rate of 76% which satisfied the effluent water quality standard for the system of interest. The results for the regulated components, SOD and SS, from the experiment showed that constructed wetland system can meet the effluent water quality standards. The average influent concentration of total phosphorus was 25.6mg/L and average effluent concentration was 7.8mg/L with average removal rate of 63%. Not like the performance of the above components, average nitrogen removal rate was only 11.2% which is not satisfactory. Although, nitrogen is not regulated at this moment, it can cause many environmental problems including eutrophication. Therefore, nitrogen removal efficiency should be improved for actual application. From the result of the field experiment, constructed wetland system was thought to be an appropriate alternative for wastewater treatment in rural area.

  • PDF

공공하수처리시설 수질기준 선진화 방안 (Improvement on Sewerage Effluent Standard of Public Sewerage Treatment Plants)

  • 유순주;박상민;권오상;박수정;염익태
    • 한국물환경학회지
    • /
    • 제29권2호
    • /
    • pp.276-287
    • /
    • 2013
  • Domestic sewage contains increasingly more pharmaceuticals and personal care products (PPCPs), due to rising use of medicines, health supplement food and daily necessities. And various types of industrial wastewater from pollution sources in treatment areas could flow into the public sewerage treatment plants (PSTPs) in metropolitan areas. The conventional PSTPs are designed to treat suspended solids, biodegradable organics, nitrogen and phosphorous from residential and industrial areas and public facilities. However, toxic, conventional, and non-coventional pollutants from non-domestic sources that discharge into sewer system as well as domestic source with various chemicals could not be treated in the conventional PSTPs and discharged untreated to public basin. In this paper we aim to consider the establishment system of effluent standard of PSTPs in comparison with water quality standard of water environment and wastewater discharge regulation. And also we suggest the necessity of regulations on the pretreatment of industrial wastewater as part of efforts to improve water quality in sewerage systems and to protect public basin.

국내 호수의 제한영양소와 하수처리장 방류수 인 기준 강화의 필요성 (The Limiting Nutrient of Eutrophication in Reservoirs of Korea and the Suggestion of a Reinforced Phosphorus Standard for Sewage Treatment Effluent)

  • 김범철;사승환;김문숙;이윤경;김재구
    • 한국물환경학회지
    • /
    • 제23권4호
    • /
    • pp.512-517
    • /
    • 2007
  • The limiting nutrient of eutrophication in freshwater bodies in Korea was examined and the phosphorus concentration standard for sewage treatment effluent was discussed. The weight ratio of N/P in 13 major reservoirs showed the range of 18 to 163, which implies phosphorus is more limited than nitrogen for algal growth. In the correlation analysis phosphorus showed higher correlation with chlorophyll-a concentration than with nitrogen. In the algal bioassay phosphorus spike test enhanced algal growth in all 25 samples of five reservoirs, while nitrogen was found to co-limit only in four samples. It confirms that phosphorus is the only limiting nutrient for eutrophication in Korean reservoirs. As many reservoirs are eutrophic in Korea, phosphorus control is critical for the management of water quality. The phosphorus standard of sewage treatment effluent in Korea was compared with other countries, and it can be concluded that phosphorus standard is too high to be effective in eutrophication control and a lower phosphorus standard is essential for the water quality improvement.

활성슬러지공정 하수종말처리장의 단위공정별 세균 제거효율 (Bacterial Removal Efficiencies by Unit Processes in a Sewage Treatment Plant using Activated Sludge Process)

  • 이동근;정미라;성기문;박성주
    • 한국물환경학회지
    • /
    • 제26권5호
    • /
    • pp.871-879
    • /
    • 2010
  • To figure out the removal efficiency of indicator and pathogenic bacteria by unit processes of a sewage treatment plant using activated sludge process, analyses were done for incoming sewage, influent and effluent of primary clarifier, aeration tank, secondary clarifier and final discharge conduit of the plant. A matrix of bacterial items (average of bacterial reduction [log/ml], p value of paired t-test, number of decreased cases of twenty analyses, removal percentage only for decreased cases) between incoming sewage and final effluent of the plant were heterotrophic plate counts (1.54, 0.000, 20, 95.01), total coliforms (1.38, 0.000, 19, 83.94), fecal coliforms (0.90, 0.000, 20, 94.84), fecal streptococci (0.90, 0.000, 20, 98.08), presumptive Salmonella (0.23, 0.561, 7, 99.09), and presumptive Shigella (1.02, 0.002, 15, 92.98). Total coliforms, fecal coliforms, heterotrophic plate counts, and fecal streptococci showed highest decrease through secondary clarifier about 1-log (p<0.001) between 88% and 96%, and primary clarifier represented the significant (p<0.05) decrease. However, final effluent through discharge conduit showed higher total coliforms and fecal streptococci than effluent of secondary clarifier (p<0.05). In addition, final effluent once violated the water quality standard while effluent of secondary clarifier satisfied the standard. Hence some control measures including elimination of deposits in discharge conduit or disinfection of final effluent are necessary.

인공습지에 의한 농촌오수처리에 관한 연구 (Study on Natural Wastewater Treatment Systems by Constructed Wetland for Rural Area)

  • 윤춘경;권순국;김형중
    • 한국농공학회지
    • /
    • 제39권4호
    • /
    • pp.55-63
    • /
    • 1997
  • Constructed wetland system which can be applied to the rural wastewater treatment system was examined by pilot plant in Kon-Kuk University. Hydraulic loading rate of wastewater was about 0.16m$^3$/m$^2$. day and theoretical detention time in the system was 1.38 days. The effluent of the septic tank for the school building was applied as inflow to the system. The influent concentration of DO was zero but effluent was up to 4.37mg/${\ell}$ which implies that oxygen was supplied enough from atmosphere by reaeration to support biological activity of the system. Average influent concentration of BOD was 104mg/${\ell}$ and effluent was 24mg/${\ell}$ with average removal rate of 76%. Average influent concentration of COD was 215mg/${\ell}$ and effluent was 63mg/${\ell}$ with average removal rate of 70 % . Average influent concentration of SS was 78mg/${\ell}$ and effluent was 10mg/${\ell}$ with average removal rate of 87%. Two components, BOD and SS, are regulated by law to keep maximum water quality standard of 80mg/${\ell}$ when daily outflow rate is less than 100$m^3$/day which is the case of most rural communities. Therefore, the results from the experiment showed that constructed wetland system can meet the water quality standard easily. Average influent concentration of total nitrogen was 165mg/lwhich is relatively higher than normal wastewater, and effluent was about 156mg/${\ell}$ with average removal rate of only 6%. Average influent concentration of total phosphorus was 41 mg/${\ell}$ and effluent was 6mg/${\ell}$ with average removal rate of 87%. Overall, constructed wetland system was thought to be effective to treat wastewater if nitrogen removal mechanism is improved. Considering low cost, less maintenance, and high treatability, this system can be a practical alternative for the wastewater treatment in rural area The experiment was performed during the summer and fall season, and treatment efficiency of the system is expected to decrease in low temperature. therefore, further study including temperature is required to evaluate feasibility of the system more in detail.

  • PDF

환경기초시설의 인 기준 강화에 따른 팔당호 유입 수계의 수질개선 효과분석 (Study on the Improvement of Water Quality by the strengthening of T-P effluent standard for Environmental Facilities in Paldang Basin)

  • 정원구;한영한;임재명
    • 산업기술연구
    • /
    • 제30권B호
    • /
    • pp.125-135
    • /
    • 2010
  • The influences on water quality of each river by effluents from environmental facilities $located^{*}$ in 14 unit watersheds of North- and South-Han River, and Gyungan-cheon were analyzed. Also, the water quality modeling for study area was carried out to analyze the improvement effect of water quality by the strengthening of T-P effluent standard of environmental facilities. For the calibration and verification of model, water quality data and effluent loading calculated for 2006 were used. Data of low water period were used for calibration, and normal water period for verification. The results of calibration and verification were well matched with the real water quality dataset of revers. Also, the validity of the results were estimated using RI (Reliability Index) method. When the T-P effluent standards for environmental facilities were strengthened, T-P concentrations were predicted to improve from $0.025mg/{\ell}$ to $0.023mg/{\ell}$ in the outlet location of North-Han River, from $0.056mg/{\ell}$ to $0.040mg/{\ell}$ for South-Han River,and from $0.233mg/{\ell}$ to $0.146mg/{\ell}$ for Gyungan-cheon. Also, the T-P concentrations of tributaries including Jojong-cheon, Dal-cheong, Sumgang, Chungmi-cheon, Bokha-cheon, Heuk-cheon, and Wonju-cheon were predicted to improve from $0.063mg/{\ell}$ to $0.010mg/{\ell}$, from $0.091mg/{\ell}$ to $0.053mg/{\ell}$, from $0.199mg/{\ell}$ to $0.100mg/{\ell}$, from $0.168mg/{\ell}$ to $0.148mg/{\ell}$, from $0.186mg/{\ell}$ to $0.105mg/{\ell}$, from $0.019mg/{\ell}$ to $0.013mg/{\ell}$, and from $0.822mg/{\ell}$ to $0.236mg/{\ell}$, respectively.

  • PDF

국내 수질측정대행업에 대한 생태독성 숙련도시험 평가 (Evaluation of Whole Effluent Toxicity (WET) Proficiency Testing for Water Quality Measurement Agencies in Korea)

  • 박우상;김상훈
    • 한국물환경학회지
    • /
    • 제29권4호
    • /
    • pp.568-573
    • /
    • 2013
  • In this study, we conducted whole effluent toxicity (WET) proficiency testing based on the results which $EC_{50}$ value of 3 types (A, B, C) unknown samples calculated from 32 water quality measurement agencies in Korea. WET proficiency testing was expected to their improve of analysis skill and ensure reliability of analysis results. Ultimately, it is intended to promote the reliable enforcement of WET. WET proficiency testing was evaluated using the z-score, robust z-score and the results showed that 30 participating agencies were "compliance". In addition, $EC_{50}$ values of "unknown sample A" were the normal distribution. Therefore, "unknown sample A" was considered as the most suitable standard toxicity substance.

우리나라 공공하수처리시설의 방류수 수질 관리체계 개선방안 고찰 - 미국, 일본, 유럽의 공공하수처리시설 방류수 수질 관리제도를 중심으로 - (A Study on the Management System Improvement of Effluent Water Qualities for Public Sewage Treatment Facilities in Korea)

  • 정동환;최인철;조양석;정현미;권오상;유순주;염익태;손대희
    • 환경영향평가
    • /
    • 제23권4호
    • /
    • pp.296-314
    • /
    • 2014
  • 우리나라의 공공하수처리시설 방류수 수질기준을 마련하는데 있어 기준설정 근거를 명확히 하는 것과 하수처리시설의 운영조사를 근거로 적정성 여부를 검토할 수 있는 종합적인 기준설정 체계를 마련할 필요가 있다. 미국은 연방정부가 POTW에 대한 최소한의 항목과 기준의 가이드라인을 제시하며, 지방정부는 국가 가이드라인과 동일하거나 주별 특성을 반영하여 보다 엄격한 가이드라인을 제시하도록 하고 있다. 일본의 경우 하수도법상 방류수 수질기준에서 하수처리시설 구조 기술상의 기준을 만족하여야 하고 방류수 수질기준과 공공수역으로의 배수기준을 동시에 적용하도록 하고 있으며 이에 대한 세부항목 및 기준은 지자체 조례로 규정하고 있다. 유럽의 경우 하수처리시설 방류수 수질기준은 공공수역에 대한 부영양화의 민감성에 따라 수질기준 항목을 차등하여 적용하고, 수계로 배출되는 오염물질 부하량에 따라 수질기준을 차등하여 적용하고 있다. 우리나라도 공공하수처리시설 방류수 수질기준 설정 시 미국 국가오염물질배출삭감제도 또는 유럽 통합환경관리제도에서와 같이 통계적 평균값 및 처리효율 또는 최적처리기술을 적용한 방류수 수질기준을 설정하는 체계를 도입하는 것이 필요하다.