• Title/Summary/Keyword: Effluent rate

Search Result 550, Processing Time 0.026 seconds

A Study on the Disinfection of Coliform Group in the Effluent of Sewage Plant by High Voltage Electric Field Treatment (고전압 전기장을 이용한 하수처리장 방류수 중의 대장균군 소독에 관한 연구)

  • Lee, Min-Gyu;Chung, Geun-Sik;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.17 no.7
    • /
    • pp.817-826
    • /
    • 2008
  • Using high voltage electric fields induced by high voltage AC (10-12 kV/cm, 20 kHz) and pulsed (20-30 kV/cm, 40 Hz) electric field generator as a semipermanent and environment-friendly disinfecting apparatus, the disinfection effect of coliform group in the effluent of sewage plant was investigated. The effects of electric field strength, treatment time, discharge area of a discharge tube, water quality factors (electric conductivity, pH and SS) on its death rate were examined. The death rate of coliform group was increased with increasing electric field strength and treatment time. For AC and pulsed electric field generator, the critical electric field strength was 6 kV/cm and 2 kV/cm, respectively, and the critical treatment time was 5 min and 2 min, respectively, regardless of electric field strength. Comparing the death rate of coliform group by AC and pulsed electric fields used in this study, its death rate was higher for the latter than the former, but did not increase linearly with increasing electric field strength. The results obtained for the effects of discharge area, electric conductivity, pH and SS on the death rate of coliform group using AC electric field (12 kV/cm, 20 kHz) were as follows: its death rate showed the trend to increase linearly with increasing discharge area; for the effect of electric conductivity, its death rate was increased with increasing electric conductivity, regardless of ionic species, increased with increasing cationic valency, but was similar between the same cationic valency; the pH $5{\sim}9$ used in this study did not affect its death rate; its death rate was decreased with increasing SS concentration.

Effects of Denitrification on Acid Production in a Two-phase Anaerobic Digestion Process (2상 혐기성 소화공정에서 탈질반응이 산생성에 미치는 영향)

  • Park, Sang-Min;Park, Noh-Back;Seo, Tae-Kyeong;Jun, Hang-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.6
    • /
    • pp.628-636
    • /
    • 2008
  • Anaerobic denitrification in a two phase anaerobic digestion(TPAD) process combined with biological nutrients removal (BNR) system was studied for a piggery wastewater treatment. Denitrification efficiency and the effects of the nitrified effluent on acidification was investigated by recycling the nitrified effluent to the acidogenic reactor. Recycle of the nitrified effluent to the acidogenic reactor enhanced the conversion efficiency of the influent COD into volatile fatty acids(VFAs) in the TPAD-BNR system treating the piggery wastewater. Acidification rate of the acidogenic sludge acclimated with the nitrified effluent showed 6 times higher than that acclimated without it. VFA could be used for denitrification as carbon sources, however, nitrate could enhance acidification activity in the acidogenic reactor. VFA production rate was affected on the COD/Nitrate(COD/N) ratio, however, it depended much more whether the acidogenic sludge acclimated with nitrate or not. Denitrification with the acidogenic sludge acclimated without nitrified effluent followed zero-order reaction and the reaction rate constants were in the range of 1.31$\sim$1.90 mg/L$\cdot$h. Denitrification reaction rate constants of the acidogenic sludge acclimated with nitrified effluent were 3.30 mg/L$\cdot$h that showed almost twice of them evaluated from the previous tests. The stoichiometric ratios of utilized COD to removed nitrate showed similar in both tests which were in the range of 5.1$\sim$6.4 at COD/N ratio of 10.

Potential Water Retention Capacity as a Factor in Silage Effluent Control: Experiments with High Moisture By-product Feedstuffs

  • Razak, Okine Abdul;Masaaki, Hanada;Yimamu, Aibibula;Meiji, Okamoto
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.4
    • /
    • pp.471-478
    • /
    • 2012
  • The role of moisture absorptive capacity of pre-silage material and its relationship with silage effluent in high moisture by-product feedstuffs (HMBF) is assessed. The term water retention capacity which is sometimes used in explaining the rate of effluent control in ensilage may be inadequate, since it accounts exclusively for the capacity of an absorbent incorporated into a pre-silage material prior to ensiling, without consideration to how much the pre-silage material can release. A new terminology, 'potential water retention capacity' (PWRC), which attempts to address this shortcoming, is proposed. Data were pooled from a series of experiments conducted separately over a period of five years using laboratory silos with four categories of agro by-products (n = 27) with differing moisture contents (highest 96.9%, lowest 78.1% in fresh matter, respectively), and their silages (n = 81). These were from a vegetable source (Daikon, Raphanus sativus), a root tuber source (potato pulp), a fruit source (apple pomace) and a cereal source (brewer's grain), respectively. The pre-silage materials were adjusted with dry in-silo absorbents consisting wheat straw, wheat or rice bran, beet pulp and bean stalks. The pooled mean for the moisture contents of all pre-silage materials was 78.3% (${\pm}10.3$). Silage effluent decreased (p<0.01), with increase in PWRC of pre-silage material. The theoretical moisture content and PWRC of pre-silage material necessary to stem effluent flow completely in HMBF silage was 69.1% and 82.9 g/100 g in fresh matter, respectively. The high correlation (r = 0.76) between PWRC of ensiled material and silage effluent indicated that the latter is an important factor in silage-effluent relationship.

Inactivation of Sewage Microorganisms using Multi-Plasma Process (멀티 플라즈마 공정을 이용한 하수 미생물의 불활성화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.985-993
    • /
    • 2014
  • For the field application of dielectric barrier discharge plasma reactor, a multi-plasma reactor was investigated for the inactivation of microorganisms in sewage. We also considered the possibility of degradation of non-biodegradable matter ($UV_{254}$) and total organic carbon (TOC) in sewage. The multi-plasma reactor in this study was divided into high voltage neon transformers, gas supply unit and three plasma modules (consist of discharge, ground electrode and quartz dielectric tube). The experimental results showed that the inactivation of microorganisms with treated water type ranked in the following order: distilled water > synthetic sewage effluent >> real sewage effluent. The dissolved various components in the real sewage effluent highly influenced the performance of the inactivation of microorganisms. After continuous plasma treatment for 10 min at 180 V, residual microorganisms appeared below 2 log and $UV_{254}$ absorbance (showing a non-biodegradable substance in water) and TOC removal rate were 27.5% and 8.5%, respectively. Therefore, when the sewage effluent is treated with plasma, it can be expected the inactivation of microorganisms and additional improvement of water quality. It was observed that the $NH_4{^+}$-N and $PO{_4}^{3-}$-P concentrations of sewage was kept at the constant plasma discharging for 30 min. On the other hand, $NO_3{^-}$-N concentration was increased with proceeding of the plasma discharge.

The Effects of Light Intensity, Inoculum Size, and Cell Immobilisation on the Treatment of Sago Effluent with Rhodopseudomonas palustris Strain B1

  • Ibrahim, Shaliza;Vikineswary, S.;Al-Azad, Sujjat;Chong, L.L.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.5
    • /
    • pp.377-381
    • /
    • 2006
  • A study was carried out to determine a suitable light intensity and inoculum size for the growth of Rhodopseudomonas palustris strain B1. The pollution reduction of sago effluent using free and immobilised R. palustris cells was also evaluated. The growth rate in glutamatemalate medium was highest at 4 klux compared to 2.5 and 3 klux. The optimal inoculum size was 10% (v/v). Both the COD and BOD of the sago effluent were reduced by 67% after three days of treatment. The difference in biomass production or BOD and COD removal with higher inoculum sizes of 15 and 20% was minimal. This could be attributed to limited nutrient availability in the substrate. The use of immobilised cells of R. palustris reduced the pollution load 10% less compared to pollution reduction by free cells. Hence, there was no significant difference in using free or immobilised cells for the treatment of sago effluent.

Performance Evaluation of Tertiary Post-denitrification Processes for the Reuse of Secondary Effluent from Wastewater Treatment Plant (하수2차처리수의 재이용을 위한 후탈질공정의 평가)

  • Lee, Chanho;Yun, Zuwhan;Yi, Yun Seok;Lee, Han Saem;Ahn, Dong Keun
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.642-649
    • /
    • 2007
  • The effectiveness of add-on tertiary treatment processes for the polishing of the effluent of a biological nutrient removal (BNR) system from a modified $A^2/O$ process has been examined under the field condition with pilot-scale plants. The add-on treatment processes of 1) combined biofilm anoxic reactor and sand filtration, and 2) two-stage denitrification filter had been operated with various operating conditions. The experimental results indicated that two-stage denitrification filter could produced a better polished tertiary effluent. Filtration rate of $150m^3/m^2{\cdot}d$ for the 2-stage denitrifying filter could decrease the nitrate removal probably due to shorter detention time that caused insufficient reaction for denitrification. Two stage denitrification filter operated with M/N ratio of 3.0 and filtration rate of $100m^3/m^2{\cdot}d$ produced the tertiary effluent with nitrate and SS concentraitons of 2.8 mg/L and 2.3 mg/L, respectively. When the operating temperature reduced $30^{\circ}C$ to $18^{\circ}C$, $NO_3{^-}-N$ removal efficiency decreased from 73% to 68%.

Simulations of a System Dynamics Model for Operations and Maintenance of Activated-Sludge Wastewater Treatment Plants (활성슬러지 하수처리시설 운영 및 유지관리를 위한 시스템다이내믹스 모델의 모의에 관한 연구)

  • Park, Suwan;Kim, Bong Jae;Jun, Hwan Don;Kim, In Chul
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.905-912
    • /
    • 2006
  • In this paper, simulation methods of the system dynamics model developed by Das et al. (1997) for activated-sludge wastewater treatment plants are illustrated in an attempt to determine the operating rules and the policies related to capacity expansion of an activated-sludge wastewater treatment plant. For existing conditions, the analyses were performed by varying activated-sludge return rate to observe changes in effluent water quality and treatment efficiency. The effluent water quality is also analyzed for various average daily inflow conditions and activated-sludge return rates. As a result, without expanding the aeration tank, maximum average daily inflow that can satisfy the effluent water quality standard of BOD $0.02kg/m^3$ was determined as $2,840m^3/hr$, subject to 100% of activated-sludge return rate while other factors remain constant. When the activated-sludge return rate is less than 100%, expansion of the aeration tank is necessary and minimum sizes of the aeration tank to satisfy the effluent water quality standard were determined for various activated-sludge return rates. In addition, the total operating and maintenance as well as unit treatment cost regression equations for activated-sludge wastewater treatment plants are suggested by using the cost data that are obtained from Water and Wastewater Division, Ministry of Environment. The regression analyses showed that the economies of scale phenomena exist in the operating and maintenance costs of activated-sludge wastewater treatment plants.

Biologic Effect of Effluents from Shipyard and the Adjacent Stream Water on Four Cultured Organisms (조선소 배출수 및 주변 하천수의 생물독성)

  • Seo, Jin-Young;Kim, Gi-Beum;An, Joon-Geon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.4
    • /
    • pp.187-192
    • /
    • 2006
  • In order to know the biological effect of effluent from shipyard and the adjacent stream water on four organisms (flatfish, rockfish, sea squirt and arkshell) cultured around the shipyard, lethal rate and DNA damage were measured after 48 hr exposure and carried out by a single cell gel electrophoresis, namely comet assay. $LC_{50}$ (48 hr) could not be calculated in any organism 48 hours after exposure to effluent from shipyard and stream water, because all organism showed a lethal rate lower than 20%. Regardless of no acute toxicity, DNA damage of flatfish and rockfish was detected higher in Jang-Pyoung stream than in control, whereas sea squirt revealed higher DNA damage in laundry waste water. From these results, Jang-Pyoung stream seemed to have a relatively higher genotoxicity rather than effluent from shipyard.

  • PDF

Microbial Conversion of Organic Wastes for Production of Biogas and Algal Biomass (바이오가스와 균체단백질 생산을 위한 유기질 폐기물의 미생물 전환 연구)

  • 권순찬;김진상
    • KSBB Journal
    • /
    • v.8 no.5
    • /
    • pp.438-445
    • /
    • 1993
  • Raw cow manure was treated by a 4-step integrated system with phase separation anaerobic digestion and algal culture. When the first methane fermentation was performed by the effluent from the acid fermenter with retention time of 4 days, the elrerage blogas production rate was 977m1/1 culture/day Gas productivity compared to conventional single-stage anaerobic digestion increased up to 31.4%. As the 2nd methane fermenter was fed by the effluent from the first methane fermenter with 4 days of retention time, average amount of 428m1/1 culture/day of biogas was produced. The reduction rate of COD in the effluent from the acid fermenter, the 1st and the 2nd methane fermenter were 71.8%, 42.6% and 24.0% respectively. Finally, we examined algal treatment process for the effluent from the 2nd methane fermenter. A semi-continuous culture of Chlorella sp. PSH3 was conducted by feeding the effluent with retention time of 10days. In this process, the production rate of algal biomass and COD reduction rate were averaged 1.8g/1 culture/day(2.8$\times$106 cells/ml) and 73%, respectively. Through the 4-setp treatments, the total chemical oxygen demand was reduced from 51,300ppm to 85ppm. Therefore, the reduction rate of total chemical oxygen demand reached about 99.8%. The results indicate that the integrated system could be applicable for treatment of organic wastes, concurrently producing biogas and algal biomass.

  • PDF

Analysis of Temperature Effect on Activated Sludge Process at Cheong-Gye Cheon Sewage Treatment Plant (활성오니공법에 있어서 수온이 처리효율에 미치는 영향에 관한 분석 -청계천 하수종말처리장에 대하여-)

  • 이은경
    • Journal of Environmental Health Sciences
    • /
    • v.7 no.1
    • /
    • pp.9-20
    • /
    • 1981
  • This study was performed to determine the correlationship between temperature and overall removals of BOD, SS and to demonstrate the effect of temperature on treatment performance. These data for a period from February 1, 1977 to January 31, 1980 were obtained from the Cheong-Gye Cheon Sewage Treatment plant. The results of correlation and stepwise multiple regression analysis were as follows. 1) Secondary effluent BOD and SS showed negative correlationship with water temperature, with correlation coefficient of -0.1710, and -0.1654 respectively. 2) Correlation coefficient of BOD, SS removal rate and water temperature were 0.1823 and 0.0429 respectively. 3) Regresion equation for estimate of BOD removal rate was as follows $\widehat{Y}_1$ (BOD removal rate)=63.9994+0.5442X(water temperature). And BOD removal rate showed non significant change according to the water temperature. 4) Regression equation for estimate of SS removal rate was as follows $\widehat{Y}_2$ (SS removal rate)=61.6881+0.1514X(Water temperature). And SS removal rate showed non significant change according to the water temperature. 5) According to the Stepwise Multiple Regression analysis, water temperature ranked second order in the BOD removal rate estimation and the equation was as follows $\widehat{Y}_1$ (BOD removal rate)=69.7398+0.2665 $X_1$ (Primary effluent BOD)+0.3562 $X_2$ (Water temperature)-0.0122 $X_3(Flow)+4413.271X_4$ (Organic Loading).

  • PDF