• 제목/요약/키워드: Effluent rate

검색결과 553건 처리시간 0.03초

Petrochemical effluent treatment using natural coagulants and an aerobic biofilter

  • Bandala, Erick R.;Tiro, Juan Bernardo;Lujan, Mariana;Camargo, Francisco J.;Sanchez-Salas, Jose Luis;Reyna, Silvia;Moeller, Gabriela;Torres, Luis G.
    • Advances in environmental research
    • /
    • 제2권3호
    • /
    • pp.229-243
    • /
    • 2013
  • Coagulation-flocculation (CF) was tested coupled with an aerobic biofilter to reduce total petroleum hydrocarbon (TPHs) concentration and toxicity from petrochemical wastewater. The efficiency of the process was followed using turbidity and chemical oxygen demand (COD). The biofilter was packed with a basaltic waste (tezontle) and inoculated with a bacterial consortium. Toxicity test were carried out using Lactuca sativa var. capitata seeds. Best results for turbidity removal were obtained using alum. Considerable turbidity removal was obtained when using Opuntia spp. COD removal with alum was 25%, for Opuntia powder it was 36%. The application of the biofilter allowed the removal of 70% of the remaining TPHs after 30 days with a biodegradation rate (BDR) value 47 $mgL^{-1}d^{-1}$. COD removal was slightly higher with BDR value 63 $mgL^{-1}d^{-1}$. TPH kinetics allowed a degradation rate constant equal to $4.05{\times}10^{-2}d^{-1}$. COD removal showed similar trend with $k=4.23{\times}10^{-2}d^{-1}$. Toxicity reduction was also successfully achieved by the combined treatment process.

MTBE(Methyl Tertiary Butyl Ether)의 토양내 이동특성에 관한 연구 (A Study on Transport Characteristics of MTBE(Methyl Tertiary Butyl Ether) in Soil)

  • 조기철;박창웅;최원준;강승엽;황종현;김윤수;오광중
    • 대한환경공학회지
    • /
    • 제30권2호
    • /
    • pp.190-198
    • /
    • 2008
  • 본 연구에서는 주유소 등의 지하 유류저장탱크나 파이프의 제한된 수명으로 인해 발생할 수 있는 가솔린의 누출에 의해 MTBE로 토양이 오염되었을 경우를 가정하여, 칼럼실험을 수행하고, CXTFIT 기법을 이용하여 토양 내 MTBE의 이동특성을 살펴 보았다. 칼럼실험에서는 토성, 수분함량, 유기물함량, 주입유속을 달리하여, 주입액과 유출액의 MTBE의 농도 측정값을 비교하고, CXTFIT기법을 이용하여 two-site 비평형 흡착모델에 사용된 매개변수(D, R, $\beta$, $\omega$)를 구하였다. 이들 매개변수와 파과곡선을 이용하여 MTBE의 토양 내 이동특성을 살펴보았다. 토양 내 미세입자와 유기물함량이 많을수록 이류에 의한 영향이 감소하는 것으로 나타났으며, 수분함량과 유속의 증가는 이류에 의한 MTBE의 이동을 더욱 가속시키는 것으로 나타났다.

영가철(Fe0) 충진 복극전해조를 이용한 질산성질소의 연속식 제거 연구 (Continuous Nitrate Removal using Bipolar ZVI Packed Bed Electrolytic Cell)

  • 정주영;김한기;신자원;박주양
    • 대한토목학회논문집
    • /
    • 제32권1B호
    • /
    • pp.79-84
    • /
    • 2012
  • 질산성질소는 일반적인 지하수 오염물질로서, 본 연구에서는 영가철을 충진한 복극전해조를 이용하여 서로 다른 조건에서 질산성질소 제거실험을 수행하였다. 실험에 사용된 전해조에는 양쪽 끝에 위치한 주 전극 사이에 전도체로서 영가철이, 비전도체로서 규사가 혼합하여 충진되었다. 모의폐수(오염된 지하수를 모사하였으며 초기 질산성질소 농도 약 30 mg/L, 전기전도도 약 300 ${\mu}S/cm$)를 이용한 연속식 실험에서 인가전압 600 V, 유입유량 20 mL/min으로 최대 99% 이상의 질산성질소를 제거하였다. 최적 혼합비 및 최적 유입유량은 각각 1:1~2:1(규사:영가철), 30 mL/min으로 결정하였다. 질산성질소의 주입농도에 따라 유출수의 pH가 비례적으로 거동하였으며, 질산성질소 환원의 최종산물로서 약 60% 정도가 암모니아로 유출되었다. 실험이 끝난 후 영가철 표면에서의 산화철은 대부분 magnetite형태로 존재하였다.

물억새를 식재한 플러그 흐름 습지에서의 RDX 제거동역학 (Removal of RDX using Lab-scale Plug Flow Constructed Wetlands Planted with Miscanthus sacchariflorus (Maxim.) Benth)

  • 이아름;김범준;박지은;배범한
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권6호
    • /
    • pp.85-94
    • /
    • 2015
  • RDX (hexahydro-1,3,5-trinitro-1,3,5-triazine) is the most important explosive contaminant, both in concentration and in frequency, at military shooting ranges in which green technologies such as phytoremediation or constructed wetlands are the best option for mitigation of explosive compounds discharge to the environment. A study was conducted with two identical lab-scale plug flow constructed wetlands planted with Amur silver grass to treat water artificially contaminated with 40 mg/L of toxic explosive compound, RDX. The reactor was inoculated with or without RDX degrading mixed culture to evaluate plant-microorganism interactions in RDX removal, transformation products distribution, and kinetic constants. RDX and its metabolites in water, plant, and sediment were analyzed by HPLC to determine mass balance and kinetic constants. After 30 days of operation, the reactor reached steady-state at which more than 99% of RDX was removed with or without the mixed culture inoculation. The major transformation product was TNX (Trinitroso-RDX) that comprised approximately 50% in the mass balance of both reactors. It was also the major compound in the plant root and shoot system. Acute toxicity analysis of the water samples showed more than 30% of toxicity reduction in the effluent than that of influent containing 40 mg/L of RDX. In the Amur silver grass mesocosm seeded with the mixed culture, the specific RDX removal rate, that is 1st order removal rate normalized to plant fresh weight, was estimated to be 0.84 kg−1 day−1 which is 16.7% higher than that in the planted only mesocosm. Therefore, the results of this study proved that Amur silver grass is an effective plant for RDX removal in constructed wetlands and the efficiency can be increased even more when applied with RDX degrading microbial consortia.

Pilot scale 세정산발효를 이용한 하수 일차슬러지의 산발효 (The Recovery of Carbon Source from Municipal Primary Sludge using Pilot Scale Elutriated Acidogenic Fermentation)

  • 권구호;김시원;정용준;민경석
    • 한국습지학회지
    • /
    • 제15권2호
    • /
    • pp.165-170
    • /
    • 2013
  • 본 연구에서는 하수일차슬러지의 가용화 및 산발효를 위한 pilot scale 세정산발효공정의 운전 특성을 검토하였다. 하수일 차슬러지의 가용화 및 산발효 특성을 평가하기 위해 SRT, 세정수 및 운전온도를 변화시켜 실험을 수행하였다. 세정산발 효공정의 가용화율은 온도가 높을수록 증가하는 반면, 산생성율은 중온조건($35^{\circ}C$)이 고온조건($55^{\circ}C$)보다 높게 나타났다. VS 감량은 약 56%, 슬러지 부피감량은 약 93%까지 나타났다. 가용화측면에서 세정산발효공정의 최적운전조건은 pH 9, $35^{\circ}C$ 및 SRT 5일이 적합 할 것으로 판단된다.

적출활동심장에서 Prostacyclin [PGI2]의 심근보호효과 (Effects of Prostacyclin [PGI2] on Myocardial Protection in the Isolating Working Heart Model)

  • 이길노;김규태
    • Journal of Chest Surgery
    • /
    • 제20권4호
    • /
    • pp.643-654
    • /
    • 1987
  • The effect of prostacyclin[PGI, ] on myocardial preservation during global ischemia was studied in the isolating working rabbit heart model. Forty hearts underwent a 15 minute period of retrograde nonworking perfusion with Krebs-Henseleit buffer solution [37*C] and were switched over to the working mode for 15 minutes. After baseline measurement of heart rate, peak aortic pressure, aortic flow, and coronary flow, all hearts were subjected to 60 minutes of ischemic arrest at 10*C induced with St. Thomas Hospital cardioplegic solution: Group I had single dose cardioplegia, Croup II double dose, Croup III oxygenated double dose, and Group IV single dose with PCI, infusion [10ng/min./gm heart weight]. Hearts were then revived with 15 minute period of nonworking reperfusion at normothermia, followed by 30 minutes of working perfusion. Repeat measurements of cardiac function were obtained and expressed as a percent of the preischemic baseline values. Oxygen content of arterial perfusate and coronary effluent was measured by designed time interval. Leakage of creatine kinase was determined during post-ischemic reperfusion period. Finally wet hearts were weighed and placed in 120*C oven for 36 hours for measurement of dry weight. In the PGI, treated group [IV], heart rate increased consistently throughout the period of reperfusion from 100*5.0% [p<0.001] to 107*6.2% [p<0.001]. The percent recovery of aortic flow showed 95*5.7% [p<0.001] at the first 3 minute and full recovery through the subsequent time. Coronary flow was augmented significantly in the 3 minute [96*6.2%, p<0.001] and then sustained above baseline values. Among the Croup I, II, and III, all hemodynamic values were significantly below preischemic levels. PGI2 relatively increased oxygen delivery [1.22*0.19ml/min, p<0.001] and myocardial oxygen consumption [0.90*0.13ml/min, p<0.001] during reperfusion period. Leakage of creatine kinase in the PGI2 group was 9.3*1.58IU/15min [p<0.001]. This was significantly lower than Group I [33.0*2.68 IU/15min]. The water content of PCI2 treated hearts [81*0.9%, p<0.001] was also lower than the other groups.

  • PDF

원자력발전소의 온배수 배출량을 고려한 어업생산감소율 추정 모델 (A Quantitative Model for Estimating Fishery Production Damages as a Result of Thermal Effluents from Nuclear Power Plants)

  • 장창익;이성일;이종희
    • 한국수산과학회지
    • /
    • 제42권5호
    • /
    • pp.494-502
    • /
    • 2009
  • A quantitative model was developed in order to estimate fishery production damage due to anthropogenically induced environmental changes. The model is described in the following equation, $Y_D=\frac{{\phi}_D}{{\phi}_G}[Y_0{\cdot}(t_p-t_0)-\frac{Y_0}{{\phi}_G}(1-e^{-{\phi}_G(t_p-t_0)})]$, where, $Y_D$ is annual amount of fishery production by nuclear power plant. ${\varphi}$ D and ${\varphi}$ G are instantaneous decreasing coefficient of fishery production by nuclear power plant and instantaneous decreasing coefficient of gross fishery production, respectively. $Y_0$ is annual mean fishery production without damages. $t_p$ is the present time, and $t_0$ is the starting time of damages. The model was applied to fishing grounds near a nuclear power plant on the east coast of Korea. Since fishery production damages have become bigger with increasing emission of thermal effluents from generators activities in the power plant, this factor has also been considered as, $\delta_{D_i}=\delta_D\({\sum}\limits_{i=0}^{n}\;W_i/W_T\)$, where, $\delta_{Di}$ is the cumulative damage rate in fishery production from generators, $\delta_D$ is the total cumulative damage rate in fishery production, $W_i$ is the emission amount of thermal effluents by generator i, and n is the number of generators in the nuclear power plant. This model can be used to conduct initial estimates of fishery production damages, before more detailed assessments are undertaken.

상향류식 혐기성반응조와 산발효조의 병합처리시 유기물질과 질소거동에 관한 연구 (A Study on the Behaviour of Organics and Nitrogen Using Upflow Anaerobic Reactor When Acid Fermenter is Added)

  • 오대민;이영신
    • 한국환경과학회지
    • /
    • 제18권3호
    • /
    • pp.325-331
    • /
    • 2009
  • This study was aimed to behaviour of organics and nitrogen on the upflow anaerobic reactor when a acid fermenter is added. Up flow anaerobic reactor (UAR) reaction will result which operates, COD removal efficiencies of reactor with nitrate loading rate 0.11, 0.66g/L/d were over 77%, but one with 1.0g/L/d was 73.5%. Especially, on NLR 0.11g/L/d, COD removal was 77% and nitrate removal efficiency was 93% simultaneously. The other side upflow anaerobic reactor and acid fermenter (UAR+AF) reaction will result witch operates, COD removal efficiencies of reactor with nitrate loading rate 0.11, 0.66g/L/d were over 85%, but one with 1.0g/L/d was 80%. Especially, on NLR 0.11g/L/d, COD removal was 85% and nitrate removal efficiency was 98% simultaneously. Also, without in reaction condition increase of influent nitrate concentration resulted in the linear decrease of nitrate removal efficiency and nitrate removal efficiency at influent nitrate-nitrogen 800mg/L was 50%. Alkalinity was increased theoretically by denitrification at low nitrate-N concentration, however, it was not increased theoretically at high nitrate-No 40% nitrate-N of UAR was denitrified until 70% height of reactor and 90% nitrate-N of UAR+AF was denitrified until 30% height of reactor Upflow anaerobic reactor was to occur accumulate acid, which TVA/Alkalinity is 0.3$\sim$0.47. Increase of NLR resulted increase of effluent alkalinity and TVA production

Isolation, identification and immobilized-cell characteristics of a bacterium that produces $N_2$ from $NH{_4}{^+}$ under an aerobic condition

  • Park, Kyoung-Joo;Cho, Kyoung-Sook;Kim, Jeong-Bo;Lee, Min-Gyu;Lee, Byung-Hun;Hong, Young-Ki;Kim, Joong-Kyun
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2005년도 생물공학의 동향(XVII)
    • /
    • pp.450-455
    • /
    • 2005
  • To treat wastewater efficiently by a one-step process of nitrogen removal, a new strain of $N_2-producing$ bacteria from $NH{_4}{^+}$ under an aerobic condition was isolated and identified. By 16S-rDNA analysis, the isolate was identified as Enterobacter asburiae with 96% similarity. The isolate shows that the capacity of $N_2$ production under an oxic condition was approximately three times higher than that under an anoxic condition. The optimal conditions (pH, temperature and C/N ratio) of the immobilized isolate for $N_2$ production were found to be 7.0, $30^{\circ}C$ and 5, respectively. Under all the optimum reaction conditions, the removal efficiency of $COD_{Cr}$ and TN reached 56.1 and 60.9%, respectively. The removal rates of $COD_{Cr}$ and TN were highest for the first 2.5 hrs (with the removal $COD_{Cr}$ ratios of 32.1), and afterwards the rates decreased as reaction proceeded. For application of the immobilized isolate to a practical process of ammonium removal, a continuous bioreactor system exhibited a satisfactory performance at HRT of 12.1 hr, in which the effluent concentrations of $NH{_4}{^+}-N$ was measured to be 15.4 mg/L with its removal efficiency of 56.0%. The maximum removal rate of $NH{_4}{^+}-N$ reached 1.6 mg $NH{_4}{^+}-N/L/hr$ at HRT of 12.1 hr (with N loading rate of 0.08 $Kg-N/m^3-carrier/d)$. As a result, the application of the immobilized isolate appears a viable alternative to the nitrification-denitrification processes.

  • PDF

멀티 플라즈마 반응기를 이용한 E. coli 소독 (E. coli Disinfection Using a Multi Plasma Reactor)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제39권2호
    • /
    • pp.187-195
    • /
    • 2013
  • Objectives: For the practical application of the dielectric barrier discharge plasma reactor, a plasma reactor able to manage large volumes of water is needed. This study investigated the possibility of the practical application of a multi-plasma reactor which is a scaled-up version of a single plasma reactor. Methods: The multi-plasma reactor consists of several high-voltage transformers and plasma modules (discharge, ground electrodes and quartz dielectric tubes). The effects of water characteristics such as voltage (30-120 V), air flow rate (1-5 l/min), number of high-voltage transformers and plasma modules, and water quality on Escherichia coli (E. coli) disinfection and decrease of COD and $UV_{254}$ absorbance were investigated. Results: The experimental results showed that at a voltage of over 80 V, most of the E. coli were disinfected within 90 seconds. E. coli inactivation was not affected by the air flow rate. E. coli disinfection in the multiplasma process showed the traditional log-linear form of the disinfection curve. E. coli inactivation performance by transformer 3-Reactor 5 and transformer 3-Reactor 3 were similar. The disinfection performance of the UV process was affected by artificial sewage water. However, the plasma process was less affected by the artificial sewage within the standards for effluent water quality. Conclusions: Disinfection performance with several low voltages and plasma modules of three to five in number applied to the plasma process was higher than that concentrating a small amount of high voltage through a single plasma reactor. Removal of COD, $UV_{254}$ absorbance, and E. coli disinfection with the plasma process were better than with the UV process.