• Title/Summary/Keyword: Effluent rate

Search Result 551, Processing Time 0.027 seconds

A Study of Disinfection Process Automation through Control Logic Program Development (제어로직 프로그램 개발을 통한 소독공정 자동운전에 관한 연구)

  • Park, Jong-Duk;Shin, Gang-Wook;Hong, Sung-Taek;Lee, Chang-Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3644-3653
    • /
    • 2011
  • This study proposes the automation of disinfection process in water treat plant to reach target effluent chlorine concentration rate according to chlorine consumption rate by varying travel time. Hydraulic analysis about the process and local facility was surveyed first and the program for automatic operation was developed to solve current problem, whose applied result was presented and proved to be better than present controller. Especially using multi variable process algorithm, the correlation coefficient is analyzed between environment factor and reaction time, and process control prove to be stable through model estimation with optimal control input.

Effects of Polyurethane as Support Material for the Methanogenic Digester of a Two-Stage Anaerobic Wastewater Digestion System

  • Woo, Kyung-Soo;Yang, Han-Chul;Lim, Wang-Jin
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.1
    • /
    • pp.14-17
    • /
    • 2002
  • To increase the efficiency of a two-stage anaerobic wastewater digestion system, various polymers were added to the methanogenic reactor as supports. The addition of polyurethane addition (6%, w/v) to the methanogenic reactor facilitated the organic loading rate (2-day Hydraulic Retention Time), higher than that of the conventional methanogenic reactor (6-day HRT). During the operation of the polyurethane-added reactor, a significant decrease in the organic mass in the effluent (COD 5-6 kg/l) was achieved, compared to that of the conventional reactor (COD 15-20 kg/l). The methane gas production rate also improved about 3-fold in the polyurethane-added reactor. More biomass was found to accumulate in the polyurethane-liquid phase (volatile solid, 26-28kg) than in the free-liquid phase (volatile solid, 5- 7 kg/l) after 90 days of operation. A scaled-up experiment with a polyurethane-added 2.5-1 reactor confirmed the previous results, and no adverse effects such as plugging or channeling due to decreased efficiency was observed even after 4 months of operation.

Methane Production and Nitrogen Removal from Piggery Wastewater in the TPAD Coupled with BNR Process (질소제거공정과 결합한 2상 혐기성 소화공정에서 돈분폐수의 메탄생성 및 질소제거)

  • Park, Noh-Back;Park, Sang-Min;Choi, Woo-Young;Jun, Hang-Bae
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.1
    • /
    • pp.18-25
    • /
    • 2009
  • Nitrogen removal and methane production from piggery wastewater were investigated in two-phase anaerobic digestion (TPAD) coupled with biological nitrogen removal (BNR) process at $35^{\circ}C$. Methane production rate was about $0.7L/L{\cdot}day$ at organic loading rate (OLR) of $1.2g{\cdot}TCOD/L{\cdot}day$ in methanogenic UASB. Conversion efficiency of the removed TCOD into methane in UASB was as high as 72% and overall TCOD removal efficiency in this system was over 97%. Ammonia nitrogen were stably removed in BNR system and overall efficiency were 98%. With recirculation of the nitrified final effluent to TPAD, nitrogen oxides were completely removed by anaerobic denitrification in the acidogenic reactor, which did not inhibit the acidogenic activities. Overall TN removal efficiency in the TPAD-BNR system was as high as 94%.

Evaluation of hydraulic dead-zone and particle removal efficiency in the base frame of a constructed wetland using computational fluid dynamics (인공습지 기본형상에서 전산유체역학을 이용한 사류구간 및 입자제거율 평가)

  • Choi, Young-Gyun;Park, Min-Cheol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.4
    • /
    • pp.495-502
    • /
    • 2013
  • Hydraulic dead-zone and particle removal efficiency in the base frame of a constructed wetland was evaluated with computational fluid dynamics (CFD). The fraction of hydraulic dead-zone was estimated to be 1.2-2.1 % (v/v) and it was attributed to the artificial islands developed in the constructed wetland. Solids deposition rate could be increased with higher hydraulic retention time (HRT, ranged from 2.2 to 4.2 hr) of the wetland and larger particle size (ranged from 10 to $50{\mu}m$) in the influent. Experimental results showed that the volume concentration of the particles smaller than $10{\mu}m$ in diameter was varied from $1.99{\times}10^3{\mu}m^3/ml$ (HRT 12.8 hr) to $3.92{\times}10^3{\mu}m^3/ml$(HRT 2.2 hr) in the influent of the constructed wetland. With the effluent volume concentration data, removal efficiency of those particles was calculated to be 71.2 and 24.7 % when the HRT was 12.8 and 2.2 hr, respectively. Similar trend with the HRT variation could be identified with CFD analysis.

Continuous Ethanol Fermentation by Immobilized Kluyveromyces marxianus F043 Using Jerusalem Arichoke Powder (돼지감자 분말을 이용한 고정화 Kluyveromyces marxianus sp.의 에탄올 연속발효)

  • 신지현;최언호
    • Microbiology and Biotechnology Letters
    • /
    • v.23 no.3
    • /
    • pp.346-351
    • /
    • 1995
  • To produce ethanol from Jerusalem artichoke powder efficiently, Kluyveromyces marxianus F043 cells were encapsulated in 2% sodium alginate and were cultured in a countinuous reactor to investigate the fermentation properties. Immobilized K. marxianus F043 cells were activated for 48 hours in a fermentor for continuous ethanol production. The culture in a CSTR using a Jerusalem artichoke substrate treated with 2% cellulase showed a decrease in ethanol concentration and an increase in residual saccharide concentration with a increasing dilution rate. Optimum conditions for high ethanol productivity and low residual saccharide output were clarified to be given at a dilution rate of 0.2 h$^{-1}$ and a Jerusalem artichoke medium concentration of 75 g/l. Ethanol productivity of 3.1 g/l-h and saccharide utilization of 62.6% were obtained under the optimum condition. When the fermentation was performed for 3 weeks under these conditions, the effluent medium showed stable ethanol concentrations of 16.3 - 17.9 g/l and viable cells of 6.60-7.16 log cells/ml without contamination. Trace amounts of methyl, n-propyl, iso-butyl, isoamyl alcohols besides ethanol were detected.

  • PDF

Selection of Surfactant and Operation Scheme for Improved Efficiency of In-situ Soil Flushing Process (원위치 토양세척 공정의 효율향상을 위한 세제선정과 운전기법)

  • Son, Bong-Ho;Lim, Bong-Su;Oa, Seong-Wook;Lee, Byung-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.824-830
    • /
    • 2006
  • Several tests were conducted to optimize the design parameters of ln-situ soil flushing processes for diesel contaminated soil. According to the batch extraction test for three anionic surfactants evaluation, Calgonit limiting bubble occurrence was selected for its higher oil cleaning efficiency. After optimum surfactant selection, there were many sets of column flushing test. Over 70% of BTEX was removed in this surfactant dose with 400% of soil volume. In the case of no surfactant addition flushing in column, so called "blank flushing test", BTEX removal rate was 64%. But when we reused the effluent for the cleaning solution, the removal rate was decreased to 46.9%. This result showed reabsorption of oil occurred on the soil. With the addition of Calgonit solution to the diesel contaminated column, BTEX was removed up to 98.9% during the first flushing and 99.4% for the second recirculation flushing. In microcosm tests, diesel contaminated soils were cleaned by both surfactant flushing and biological activities. In anoxic condition, nitrate was used as an electron acceptor while the surfactant and the oil were used an electron donor. BTEX removal efficiency could be achieved up to 80% by biological degradation.

Column-switching High Performance Liquid Chromatographic Determination of Fluconazole in Human Plasma (컬럼 스위칭 고속액체크로마토그라프법을 이용한 혈장 중 플루코나졸의 분석)

  • Jee, Jun-Pil;Jin, Sook;Lee, Mi-Kyung;Kim, Yang-Bae;Kim, Chong-Kook
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.1
    • /
    • pp.51-54
    • /
    • 2000
  • A column-switching high performance liquid chromatographic method has been developed for the determination of a fluconazole in human plasma. Each plasma sample was centrifuged for 10 min at 5000 g. After an aliqout of the supernatant was taken to nylon microcentrifuge filter, these samples were centrifuged for 10 min at 5000 g. An aliqout of the supernatant was injected directly onto the HPLC column. Deionized water was run for 2 min at a flow rate of 1.0 ml/min to retain fluconazole in an extration column, while proteins and endogenous interferences were eluted to the waste. The analyte was then back-flushed onto an analytical column, $C_{18}$ reversed-phase column. The mobile phase for analytical column, 0.01 M sodium acetate (pH 5.0)-methanol (65:35, v/v), was run at a flow rate of 1.0 ml/min. The column effluent was monitored by ultraviolet detection at 261 nm. The retention time for fluconazole was 11.76 min in human plasma. The detection limit for fluconazole in human plasma was $0.2\;{\mu}g/ml$. No interference from endogenous substances was observed.

  • PDF

Hydrodynamics and parametric study of an activated sludge process using residence time distribution technique

  • Sarkar, Metali;Sangal, Vikas K.;Bhunia, Haripada
    • Environmental Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.400-408
    • /
    • 2020
  • Hydrodynamic study of Activated Sludge Process (ASP) is important to optimize the reactor performance and detect anomalies in the system. Residence time distribution (RTD) study has been performed using LiCl as tracer on a pilot scale aeration tank (AT) and ASP, treating the pulp and paper mill effluent. The hydraulic performance and treatment efficiency of the AT and ASP at different operating parameters like residence time, recycle rate was investigated. Flow anomalies were identified and based on the experimental data empirical models was suggested to interpret the hydrodynamics of the reactors using compartment modelling technique. The analysis of the RTD curves and the compartment models indicated increase in back-mixing ratio as the mean hydraulic retention time (MHRT) of the tank was increased. Bypassing stream was observed at lower MHRT. The fraction of dead zone in the tank increased by approximate 20-25% with increase in recycle rate. The fraction of the stagnant zone was found well below 5% for all performed experiments, which was under experimental error. The substrate removal of 91% for Chemical oxygen demand and 96% for Biochemical oxygen demand were observed for the ASP working at a hydraulic mean residence time 39 h MRT with a 20% recycling of activated sludge.

High-Rate Nitrogen Removal using a Submerged Module of Sulfur-Utilizing Denitrification (침지형 황 탈질 모듈을 이용한 고속의 질소제거)

  • Moon, Jin-Young;Hwang, Yong-Woo;Ga, Mi-Sun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.429-437
    • /
    • 2007
  • This study aims to develop a sulfur-using denitrification process which is possible a renovation to advanced treatment plant submerging a simple module in activated sludge aeration tank. At first, the impact factor of sulfur-using denitrification was appreciated by the batch test. Secondly, reflecting a dissolved oxygen effect of sulfur-using denitrification that was confirmed by the batch test, in a continuous nitrification/sulfur-using denitrification, high-rate nitrogen removal reaction was induced at optimum condition controlling DO concentration according to phases. Also, inside and outside of sulfur-using denitrification module was covered with microfilter and the module was considered as an alternative of clarifier. Result of batch test for sulfur-using denitrification, $NO_2{^-}N$ was lower for consumption of alkalinity and sulfur than that of $NO_3{^-}-N$. These results revealed the accordance of theoretical prediction. In continuous nitrification/sulfur-using denitrification experiment, actual wastewater was used as a influent, and influent nitrogen loading rates were increased 0.04, 0.07, 0.11, $0.14kg\;N/m^3-day$ by changing hydraulic retention times. At this time, nitrogen loading rates of packed sulfur were increased 0.23, 0.46, 0.69, $0.93kg\;N/m^3-day$. As a result, nitrification efficiency was about 100% and denitrification efficiency was 93, 81, 79, 72%. Accordingly, nitrogen removal was a high-rate. Also the module of sulfur-using denitrification covered with microfilter did not make a fouling phenomena according to increased flux. And the module was achieved effluent suspended solids of below 10 mg/L without a clarifier. In conclusion, it is possible a renovation to advanced treatment plant submerging a simple module packed sulfur in activated sludge aeration tank of traditional facilities. And the plant used the module packed sulfur is expected as a effective facilities of high-rate and the smallest.

Low Temperature Effects on the Nitrification in a Nitrogen Removal Fixed Biofilm Process Packed with SAC Media

  • Jang, Se-Yong;Byun, Im-Gyu
    • Journal of Environmental Science International
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • A fixed biofilm reactor system composed of anaerobic, anoxic(1), anoxic(2), aerobic(1) and aerobic(2) reactor was packed with synthetic activated ceramic (SAC) media and adopted to reduce the inhibition effect of low temperature on nitrification activities. The changes of nitrification activity at different wastewater temperature were investigated through the evaluation of temperature coefficient, volatile attached solid (VAS), specific nitrification rate and alkalinity consumption. Operating temperature was varied from 20 to $5^{\circ}C$. In this biofilm system, the specific nitrification rates of $15^{\circ}C$, $10^{\circ}C$ and $5^{\circ}C$ were 0.972, 0.859 and 0.613 when the specific nitrification rate of $20^{\circ}C$ was assumed to 1.00. Moreover the nitrification activity was also observed at $5^{\circ}C$ which is lower temperature than the critical temperature condition for the microorganism of activated sludge system. The specific amount of volatile attached solid (VAS) on media was maintained the range of 13.6-12.5 mg VAS/g media at $20{\sim}10^{\circ}C$. As the temperature was downed to $5^{\circ}C$, VAS was rapidly decreased to 10.9 mg VAS/g media and effluent suspended solids was increased from 3.2 mg/L to 12.0 mg/L due to the detachment of microorganism from SAC media. And alkalinity consumption was lower than theoretical value with 5.23 mg as $CaCO_3$/mg ${NH_4}^+$-N removal at $20^{\circ}C$. Temperature coefficient (${\Theta}$) of nitrification rate ($20^{\circ}C{\sim}5^{\circ}C$) was 1.033. Therefore, this fixed film nitrogen removal process showed superior stability for low temperature condition than conventional suspended growth process.