• Title/Summary/Keyword: Effluent discharge

Search Result 205, Processing Time 0.034 seconds

Temporal and Spatial Variations of Phytoplankton Communities in the Pelagic Environment of Kori, Korea (고리해역 표영환경내 식물플랑크톤 군집의 시공간적 변화)

  • 여환구;허성회
    • Korean Journal of Environmental Biology
    • /
    • v.17 no.1
    • /
    • pp.71-77
    • /
    • 1999
  • Phytoplankton communities were investigated 13 times during the period from November, 1995 to December, 1996 in the coastal area of Kori. A total of 162 taxa (including unidentified species) were observed; 120 diatoms, 3 silicoflagellates, 34 dinoflagellates, 2 euglenoids, 1 chlorophyte and 2 unidentified microflagellates. A diatom species, Skeletonema costatum (Greville) Clove dominated all the year round. The standing stocks of phytoplankton ranged from 94 cells/ml in August to 1059 cells/ml in July. The peaks of standing stocks occurred in February and July. The effects of thermal effluent to the phytoplankton communities changed seasonally and might affect increasing the standing stocks where about 1 ∼ 3 km from the discharge of Kori Nuclear Power Plant in autumn and winter. But the effects of thermal effluent must be negative in summer.

  • PDF

TREATMENT OF HIGH-CONCENTRATION SWINE WASTEWATER BY ANAEROBIC DIGESTION AND AN AQUATIC PLANT SYSTEM

  • Kim, B.U.;Kwon, J.H.
    • Environmental Engineering Research
    • /
    • v.11 no.3
    • /
    • pp.134-142
    • /
    • 2006
  • The treatment of high-strength swine wastewater by anaerobic digestion combined with an aquatic plant system was investigated. Anaerobic digestion of swine wastewater gave volatile solids (VS) removal efficiencies of 43.3%, 52.1% and 54.5% for hydraulic retention times (HRTs) of 20, 30, 40 days, respectively. The removal efficiencies of VS, total chemical oxygen demand (TCOD) and soluble chemical oxygen demand (SCOD) decreased with increasing VS volumetric loading rate (VLR). Higher organic removal efficiency was observed at longer HRTs for the same VS volumetric loading rate. As VS volumetric loading rate increased, biogas production increased and the methane content of the biogas decreased. Experiments using duckweed (Lemna species) as an aquatic macrophyte gave the following results. In the case of nitrogen, removal efficiency was above 60% and effluent concentration was below 10.0 mg/L when the influent ammonia-N loading was about $1.0\;g/m^2/day$. In the case of phosphorus, removal efficiency was above 55% and effluent concentration was below 2.0 mg/L when the influent $PO_4$-P loading was about $0.15\;g/m^2/day$. In addition, crude protein and phosphorus content of duckweed biomass increased from 15.6% to 41.6% and from 0.8% to 1.6%, respectively, as the influent nutrient concentration increased. The treatment of high-strength swine wastewater by anaerobic digestion combined with an aquatic plant system offers good performance in terms of organics and nutrient removal for relatively low operation and maintenance costs. The results indicate that under appropriate operational conditions, the effluent quality is within the limits set by Korean discharge criteria.

A review on status of organic micropollutants from sewage effluent and their management strategies (하수 유래 미량오염물질 현황과 관리 방안 고찰)

  • Choi, Sangki;Lee, Woongbae;Kim, Young-Mo;Hong, Seok-Won;Son, Heejong;Lee, Yunho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.3
    • /
    • pp.205-225
    • /
    • 2021
  • Due to the large-scale production and use of synthetic chemicals in industralized countries, various chemicals are found in the aquatic environment, which are often termed as micropollutants. Effluents of municipal wastewater treatment plants (WWTPs) have been identified as one of the major sources of these micropollutants. In this article, the current status of occurrence and removal of micropollutants in WWTPs and their management policies and options in domestic and foregin countries were critically reviewed. A large number of pharmaceuticals, personal care products, and industrial chemicals are found in WWTPs' influent, and are only partially removed by current biological wastewater treatment processes. As a result, some micropollutants are present in WWTPs' effluents, which can negatively affect receiving water quality or drinking water source. To better understand and assess the potential risk of micropollutants, a systematic monitoring framework including advanced analytical tools such as high resolution mass spectrometry and bioanalytical methods is needed. Some Western European countries are taking proactive approach to controlling the micropollutants by upgrading WWTP with enahnced effluent treatment processes. While this enahnced WWTP effluent treatment appears to be a viable option for controlling micropollutant, its implementation requires careful consideration of the technical, economical, political, and cultural issues of all stakeholders.

Coastal Eutrophication caused by Effluent from Aquaculture Ponds in Jeju (제주연안 육상양식장 밀집지역 주변해역의 영양염 과잉 요인)

  • Koh, Hyuk-Joon;Park, Sung-Eun;Cha, Hyung-Kee;Chang, Dae-Soo;Koo, Jun-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.4
    • /
    • pp.315-326
    • /
    • 2013
  • This study investigated the temporal-spatial distribution and variations in water quality parameters (temperature, salinity, pH, DO, COD, SPM, DIN, DIP, silicate, TN, TP, and chlorophyll-a) in the coastal area of Jeju, Korea, adjacent to aquaculture ponds (Aewol-ri, Haengwon-ri, Pyosun-ri, and Ilkwa-ri). Data were collected bimonthly from February 2010 to December 2011. A principal component analysis (PCA) identified three major factors controlling variations in water quality during the sampling period. Aquaculture effluent water led to large changes in nutrient levels. The highest nutrient values were observed during the investigation period. The relatively large increase in organic matter at the sampling stations coupled with sea area runoff events during the summer rainy period. Variation in chlorophyll-a concentration was mainly driven by meteorological factors such as air temperature and rainfall in the coastal areas of Aewol and Haengwon. In the coastal areas of Pyosun and Ilkwa, pollution was caused by anthropogenic factors such as discharge of aquaculture effluent water. High nutrient concentrations at the majority of the coastal stations indicate eutrophication of coastal waters, especially within a distance of 300 m and depth of 10m from drainage channels. Coastal eutrophication driven by aquaculture effluent may be harmful inshore. Events such as eutrophication may potentially influence water pollution in aquaculture ponds when seawater intake is detected because of aquaculture effluent water.

Water Reuse of Sewage Discharge Water Using Fertilizer Drawn Forward Osmosis - Evaluating the Performance of Draw Solution - (비료 유도용액의 정삼투를 이용한 하수처리수의 재이용 - 유도용액의 성능 평가 -)

  • Kim, Seung-Geon;Lee, Ho-Won
    • Membrane Journal
    • /
    • v.26 no.2
    • /
    • pp.108-115
    • /
    • 2016
  • This study is to evaluate the performance of draw solutions in the water reuse of sewage discharge water using fertilizer drawn forward osmosis. Feed water used in all experiments was the effluent from secondary sedimentation tank in activated sludge process. Considering osmotic pressure, solubility, and pH, $NH_4H_2PO_4$, KCl, $KNO_3$, $NH_4Cl$, $(NH_4)_2HPO_4$, $NH_4NO_3$, $NH_4HCO_3$, and $KHCO_3$ were screened from a comprehensive lists of fertilizer. Their performances were evaluated in terms of water permeate flux and reverse solute flux. KCl showed the highest average water flux followed by $NH_4Cl$, $NH_4NO_3$, $KNO_3$, $KHCO_3$, $NH_4HCO_3$, $NH_4H_2PO_4$, and $(NH_4)_2HPO_4$. Using KCl as draw solution, the average water permeate flux was 13.49 LMH. There was no big difference in osmotic pressure between the effluent from secondary sedimentation tank and deionized water. $NH_4H_2PO_4$ showed the lowest reverse solute flux followed by $NH_4Cl$, $(NH_4)_2HPO_4$, $KNO_3$, $NH_4HCO_3$, and $NH_4NO_3$. Using $NH_4H_2PO_4$ as draw solution, the reverse solute flux was $4.96{\times}10^{-3}mmol/m^2{\cdot}sec$.

Appropriate Sewerage Systems for Korea (우리나라 적합 하수도시설 및 관리방안)

  • 이상은
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.2
    • /
    • pp.37-52
    • /
    • 1992
  • Since the first sewage treatment plant was constructed in 1976, the sewerage systems of Korea have been rapidly expanded. As of the end of 1991, 22 sewage treatment plants with total capacity of 5.4 million tons/day are in operation which is equivalent of 3395 total daily sewage generation. Total extension of sewer 39.534 km in 1990 which is 55% of the target extension for the year 2001. However, the most sewage treatment plants employ activated sludge process which may not be suitable for medium and/or small scale plants. The poor existing sewer systems do not effectively collect and transport sewage to adversely affect the function of sewage treatment plant. To select the appropriate treatment system, the cities are classified into 3 categories such as large and medium size inland cities, small size cities and coastal cities. Considering the criteria suggested during this study, appropriate treatment processes were selected for each category. Conventional activated sludge process and step aeration process were found to be the most appropriate for big inland cities while biological nutrient removal processes should be considered for the cities discharge the effluent to lakes or reservoirs. RBC or Oxidation Ditch process might be appropriate for the medium size cities while several processes which do not require skilled operation and maintenance were suggested for the small cities. Ocean discharge after primary treatment can be considered for some east coast cities, Appropriate methodology to rehabilitate the existing sewers and strategy to convert combined sewer system to separate sewer system were proposed. This paper also include the appropriate management system for industrial wastewater, sludge and nightsoil.

  • PDF

Effect of NOD on BOD Test for the Effluents of Biological Treatment Plant (하수처리장 유출수의 NOD를 고려한 BOD 측정에 관한 연구)

  • Jang, Se-joo;Lee, Seong-ho;Park, Hae-sik;Park, Chung-kil
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.188-192
    • /
    • 2007
  • The biochemical oxygen demand (BOD) test is widely used to determine the pollution strength of water, to evaluate the performance of wastewater treatment plants and to judge compliance with discharge permits. However, nitrification is a cause of significant errors in measuring BOD, particularly when a large population of nitrifying organisms is existing in water such as effluents from biological treatment plants. In order to investigate the amount of nitrogenous oxygen demand (NOD), BOD with and without inhibitor was measured as samples in the biological treatment plants. About 81% of effluent BOD from the biological treatment plant used in this experiment was comprised of NOD. In the case of influents, the NOD accounted for about 9% of BOD. The inhibited 5-day BOD (Carbonaceous BOD) test must be considered in evaluating the performance of wastewater treatment plant and judging compliance with discharge permit limitations.

Remove of Three Pathogenic Bacteria in Cultured Fish and Tetracycline Antibiotics Using Underwater Non-Thermal Dielectric Barrier Discharge Plasma (수중 비열 유전체장벽 방전 플라즈마를 이용한 양식어류의 병원성세균 3종 및 Tetracycline계 항생제 제거)

  • Cho, Kyu Seok;Park, Jong Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.55 no.6
    • /
    • pp.910-916
    • /
    • 2022
  • The purpose of this study is to evaluate the effect of underwater non-thermal dielectric barrier discharge plasma (DBD plasma) on the sterilization of three types of pathogenic bacteria that cause diseases in freshwater fish and the reduction of a tetracycline antibiotics. This experiment was conducted in the DBD plasma generator, and the voltages used to generate plasma were 11.6 kV and 23.1 kV. The measurement intervals were 0, 1, 5, 10 and 15 min. As a result of DBD plasma treatment, Aeromonas hydrophila, Edwardsiella tarda and Pseudomonas fluorescens were removed 93-99% after 5 min at 23.1 kV, and the tetracycline antibiotics were reduced 70-95% after 15 min at 23.1 kV. In this study, as a result of treating the effluent with DBD plasma at a fish farm where the medicinal bath was conducted with oxytetracycline-HCl (OTC-HCl) products, OTC-HCl decreased by 62% after 10 min at 23.1 kV.

Water Quality Impact Assessment in Korea - Comparing with the Integrated Control of Pollutant-Discharging Facilities - (수질분야 환경영향평가의 개선방안 - 환경오염시설의 통합관리와 대비하여 -)

  • Lee, Jong Ho;Cho, Jae Heon
    • Journal of Environmental Impact Assessment
    • /
    • v.26 no.5
    • /
    • pp.331-343
    • /
    • 2017
  • The important changes in water environment management in Korea can be summarized as the enactment of Act on the Integrated Control of Pollutant-Discharging Facilities. Therefore water quality impact assessment should be reexamined and be revised. This study examines the present water quality impact assessment items (permissible discharge limits, standards for effluent water quality including Total Pollutant Load Management System) and considers the land use regulation for water quality conservation and NVZs(Nitrate Vulnerable Zones of EU and England). It also considers lately adopted standards(maximum discharge standards, permissible discharge standards, and marginal discharge standards etc) based on Act on the Integrated Control of Pollutant-Discharging Facilities and then compares Korean BAT and its counterpart control technology of U.S.A. And it also compares the items of water quality impact assessment with those of Integrated Control of Pollutant-Discharging Facilities, based on EIS reporting items. This study suggests five improvement measures for water quality impact assessment. First reflection of discharge impact analysis on impact prediction and assessment, second reflection of permissible discharge standards on agreed standards in the EIA procedure, third, reflection of diversified BAT on mitigation measures in the EIA procedure, forth introduction of land use regulation such as NVZs, finally strengthening linkage between water quality items and land use items etc.

High-Rate Phosphorous Removal by PAC (Poly Aluminum Chloride) Coagulation of A2O Effluent (생물공정 처리수의 PAC (Poly Aluminum Chloride) 응집에 의한 고효율 인 제거 특성)

  • Hwang, Eung-Ju;Cheon, Hyo-Chang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.8
    • /
    • pp.673-678
    • /
    • 2009
  • High-rate phosphorous removal by PAC (poly aluminum chloride) coagulation of A2O effluent was investigate to meet the stringent requirement of wastewater discharge from municipal wastewater treatment plant. A series of jar tests were conducted to find optimum coagulation condition and to enhance removal efficiency. The optimum volumetric concentration of PAC was 30 ppm (2.81mol Al/mol P by mol ratio). Only 17.2% of soluble P was removed for 30 minutes' settling without PAC addition, while this increased to 30.3% by dosing 10ppm PAC. It even increased conspicuously from 49.3% to 88.4% by increasing PAC dose from 20 ppm to 30 ppm. 92.4% of total P was removed by 30 ppm PAC, and the effluent concentration (0.3 mg/L) was acceptable for discharge. The optimum value of coagulation time, settling time, and pH were 4minutes, 20 minutes, and 7.0, respectively. It was not necessary to control pH of raw sample whose pH was 7.0. Soluble P removal was remarkably enhanced at pH 7.0. This implied that sweep floc formation by $Al(OH)_3$ was the main mechanism of coagulation for soluble P removal. Influent and effluent of secondary clarifier were tested for coagulation, and the effluent was better for high-rate P removal. It resulted in 0.18 mg/L of P and 95.4% of P removal by coagulation. It was favorable to recycle the treated water to coagulation tank and the optimum recycle ratio was 0.3.