• Title/Summary/Keyword: Effluent Standards of Sewage Treatment Plants

Search Result 11, Processing Time 0.022 seconds

A Study on the Evaluation for Operations of Public Sewage Treatment Plants Using Statistics Technique (통계기법을 이용한 공공하수처리시설의 운영실태 평가방법 연구)

  • Choi, In-Cheol;Ahn, Tae-Ung;Yu, Soon-Ju;Chung, Hyen-Mi;Kwon, Oh-Sang;Kim, Won-Ky;Yeom, Ick-Tae;Son, Dae-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.5
    • /
    • pp.524-531
    • /
    • 2014
  • Korea has been trying to manage water quality of rivers and lakes in many ways. Ministry of Environment is making continuous efforts of operation control improvement such as strengthening effluent standards in sewage treatment plants and expanding Tele-Monitoring System (TMS). However, evaluation method for operations of sewage treatment plants and establishment system of effluent standards are inadequate. The objective of this study is to evaluate for operations of sewage treatment plants using statistics technique such as frequency analysis, percentile, normal distribution analysis. We used the effluent data (BOD, COD, SS) collected at 299 plants in 2012. The values were very low by comparison with standards. The Data followed a normal distribution. We think that distribution characteristics are closely related with effluent standards, especially T-P and BOD. Statistics technique attempted in this study can be used to evaluate for operations of sewage treatment plants and assess the appropriateness of effluent standards based on TBEL(Technology-based effluent limitation). And, this technique can be used to figure out the overall level of plants, the status of each plant and the favorable treatment process for each item (BOD, COD etc.). Data acquired through this method can be used to improve facilities and operation techniques and decide on a sewerage policy.

A Study on the Management System Improvement of Effluent Water Qualities for Public Sewage Treatment Facilities in Korea (우리나라 공공하수처리시설의 방류수 수질 관리체계 개선방안 고찰 - 미국, 일본, 유럽의 공공하수처리시설 방류수 수질 관리제도를 중심으로 -)

  • Jeong, Donghwan;Choi, Incheol;Cho, Yangseok;Chung, Hyenmi;Kwon, Ohsang;Yu, Soonju;Yeom, Icktae;Son, Daehee
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.4
    • /
    • pp.296-314
    • /
    • 2014
  • In recent years, Ministry of Environment (MOE) has been implementing a phased strengthening of the effluent standards for sewage treatment plants. In this regard, a comprehensive system should be developed to help check the appropriateness of such standards by specifying the grounds for standard-setting and investigating the current operation of sewage treatment plants clearly. It is necessary to establish a new standard-setting system for the effluent that is in a closer connection with the environmental criteria and rating systems. In the United States, the federal government provides guidelines on the least provisions and requirements for the Publicly Owned Treatment Works (POTWs). Local governments set the same or stricter guidelines that reflect the characteristics of each state. In Japan, the sewage treatment plants are subject to both the effluent standards and the discharge acceptable limits to pubic waters under the sewerage law. Specific requirements and limits are set in accordance with local government regulations. The European Union imposes sewage treatment plants with different provisions for effluent standards, depending on the sensitivity of public waters to eutrophication. The effluent standards for sewage treatment plants are classified by pollutant loads discharged to receiving waters. MOE also needs to introduce systems for setting new parameter standards on a POTW effluent by applying statistical means and treatment efficiencies or optimal treatment techniques, as seen in the cases of the US National Pollutant Discharge Elimination System (NPDES) or the EU Integrated Pollution Prevention and Control (IPPC).

Evaluation of Korean Water Quality Standards in Winter by Characteristics and Statistical Analyses of the Effluent Water Quality at the Sewage Treatment Plants in Korea (우리나라 공공하수처리시설의 방류수 수질현황 분석을 통한 겨울철 방류수수질기준의 적정성 평가)

  • Um, Chul Yong;Chu, Kyoung Hoon;Yun, Zu Whan;Choi, Ik Hoon;Park, Jae Young;Lee, Han Saem;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.4
    • /
    • pp.523-532
    • /
    • 2011
  • In this study, from 2004 to 2008 influents and discharging effluents from 241 municipal public sewage treatment plants were surveyed. Statistics including average, Coefficient of Variation (CV) and Coefficient of Reliability (COR) for each season, time series analysis for removal efficiency and water quality of effluents, and a comparison of the effluent standards in Korea and other countries were presented. The average concentrations of TN and TP in influents. during winter season were 32.6 and 3.78 mg/L and during other season were 30.8 and 3.61 mg/L in 2008, respectively. The average TN concentration on the basis of the maximum monthly concentrations in the effluents during winter season ranged from 14.2~17.4 mg/L and during other season ranged from 12.2~14.8 mg/L. The TP concentration in the effluents depending on the each season was no big difference. TN removal efficiency decreased from Jan. to Feb. and TP removal efficiency decreased in Jan., Jun and July. Maximum COR during winter season were 0.61 but the COR for TN and TP during other season ranged from 0.96~1.48 and 1.09~1.81, respectively, due to big difference in the standard for TN and TP in effluents depending on the season. TN and TP standards for effluent of sewage treatment during winter season in Korea was much higher than those in other countries. Therefore the lower effluent standards during winter season is essential for the water quality improvement.

A Study on Strengthening Option of T-N Effluent Water Quality Standards of Sewage Treatment Plants (하수처리시설의 T-N 방류수 수질기준 강화방안에 관한 연구)

  • Kim, Ji Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.2
    • /
    • pp.216-225
    • /
    • 2018
  • Over the past 40 years, the public sector has continued to invest in the sewage treatment plants (STPs) in Korea. Currently, the domestic sewage treatment rate is over 90% with the enhancement of operating efficiency of the STPs, and water quality of major rivers has been continuously improved. However, COD and T-N indicators are stagnating or slightly worsening, and though advanced treatment facilities are installed in most of the STPs, there is a limit to the removal of nutrients. Since there are a lot of water pollution sources in the vicinity of the watershed because of high population density in Korea, it is essential to reduce the inflow of the nutrients in order to prevent the eutrophication of the rivers and lakes. While the effluent T-P standard in STPs has greatly strengthened since 2012, which results in the considerable investment for the improvement of treatment process in STPs for the last few years, it is necessary to strengthen the T-N standards, as the effluent standard of T-N has been maintained at 20 mg/L since 2002. In this study, based on the analysis of the effluent T-N standard status of major industrialized countries, and the domestic nitrogen load in public waters, the option of appropriate T-N standard level is reviewed, and the required investment costs and the effect of strengthening the standard are estimated.

A Study on the Influence of a Sewage Treatment Plant's Operational Parameters using the Multiple Regression Analysis Model

  • Lee, Seung-Pil;Min, Sang-Yun;Kim, Jin-Sik;Park, Jong-Un;Kim, Man-Soo
    • Environmental Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • In this study, the influence of the control and operational parameters within a sewage treatment plant were reviewed by performing multiple regression analysis on the effluent quality of the sewage treatment. The data used for this review are based on the actual data from a sewage treatment plant using the media process within the year 2012. The prediction models of chemical oxygen demand ($COD_{Mn}$) and total nitrogen (T-N) within the effluent of the 2nd settling tank based on the multiple regression analysis yielded the prediction accuracy measurements of 0.93 and 0.84, respectively; and it was concluded that the model was accurately predicting the variances of the actual observed values. If the data on the energy spent on each operating condition can be collected, then the operating parameter that conserves energy without violating the effluent quality standards of COD and T-N can be determined using the regression model and the standardized regression coefficients. These results can provide appropriate operation guidelines to conserve energy to the operators at sewage treatment plants that consume a lot of energy.

A Study on the Allocation of Permissible Water Pollution Load in the Total Water Pollution Load Management Plan (수질오염 총량관리계획과정의 오염부하량 할당에 관한 연구 - 경기도 광주시를 사례로 -)

  • Kim, Sie-Heon;Rim, Jay-Myung
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.5
    • /
    • pp.337-346
    • /
    • 2005
  • Pollution load allocation can likely be much controversial, which is essential to formulate the total water pollution load management plan. Existing rules(or guidances) in Korea, can provide no specific criteria for load allocation. Therefore, this paper studied(comprehensively) possible standards how or why to choose any particular allocation method, which was applied in the Gwangju City's load allocation for the satisfaction of set water quality goal. This load allocation is basically focused on the load reduction of domestic wastewater rather than industrial wastewater, because the land-use is strictly regulated and larger sources of pollution are few in the Gwangju City. This paper recommends the city to increase the capacity of sewage treatment plants, promote sewerage maintenance, and set higher effluent standards.

A Study on Treatment Measures of Carcass Disposal Site Leachate into the Livestock Manure and Sewage Treatment Facilities using NIER-MASS program (NIER-MASS 프로그램을 이용한 가축매립지 침출수 연계처리 방안 연구)

  • Jeong, Dong-Hwan;Lee, Chulgu;Shin, Jinsoo;Kim, Hyunwoo;Yoon, Soohyang;Kim, Yongseok;Yu, Soonju;Kim, Shinjo
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.725-734
    • /
    • 2012
  • The outbreak of foot and mouth disease in November 2010 raised many social, economic and environmental issues and water contaminations by leachate from carcass disposal sites particularly emerged as a serious concern. In oder to efficiently handle these problems, a critical method is required to transport leachate to livestock manure and sewage treatment plants and purify it. This study aims to present the best applicable method to transport leachate from carcass disposal sites into livestock manure and sewage treatment facilities. We investigated the biological and chemical characteristics such as BOD, COD, SS, TN, TP and Total coliforms. Current conjugated treatments in livestock manure and sewage treatment plants was studied by surveying the operations of those facilities. The NIER-MASS(National Institute of Environmental Research - Mass Balance Evaluation System of Sewage Treatment Facilities) program was applied to present the best conjugated treatment method through estimating the maximum daily load to meet the water quality standards in effluent.

Preliminary Studies for Efficient Treatment of Wastewater Milking Parlor in Livestock Farm (젖소 착유세정폐수의 효율적인 정화처리를 위한 기초연구)

  • Jang, Young Ho;Lee, Soo Moon;Kim, Woong Su;Kang, Jin Young
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.500-507
    • /
    • 2020
  • This study examined the wastewater at a livestock farm, and found that the dairy wastewater from the milking parlor had a lower concentration than the piggery wastewater, and that it was produced at a rate under 1.3 ㎥/day in a single farmhouse. The amount of dairy wastewater was determined based on the performance of the milking machine, the maintenance method of the milking parlor, and the amount of milk production allocated for each farmhouse, not by the area. The results confirmed that both dairy wastewater treatment processes, specifically those using Hanged Bio-Compactor (HBC) and Sequencing Batch Reactor (SBR), can fully satisfy the water quality standards of discharge. The dairy wastewater has a lower amount and concentration than piggery wastewater, meaning it is less valuable as liquid fertilizer, but it can be easily degraded using the conventional activated sludge process in a public sewage treatment plant. Therefore, discharging the dairy wastewater after individual treatment was expected to be a more reasonable method than consigning it to the centralized wastewater treatment plant. The effluent after the SBR process showed a lower degree of color than the HBC effluent, which was attributed to biological adsorption. In the case of the milking parlor in the livestock farm, the concentrations of the effluents obtained after HBC and SBR treatments both satisfied water quality standards for the discharge of public livestock wastewater treatment plants at 99% confidence intervals, and the concentrations of total nitrogen and phosphorous in untreated wastewater were even lower than the water quality standards of discharge. Therefore, we need to discuss strengthening the water quality standards to reduce environmental pollution.

Evaluation of the impact of sewage treatment plants in the Linked treatment through the sewage treatment computer simulation program (하수처리 전산모사 프로그램을 통한 연계처리시 하수처리장 영향 평가)

  • Kim, Sungji;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.22 no.4
    • /
    • pp.321-327
    • /
    • 2020
  • Recently The amount of wastewater and linked wastewater is being increased every year due to industrial development, population growth, and improvement in living standards. Linked wastewater shows the feature-low flow rate and high concentration. Therefore, it has been shown that it has a great impact on the operation of the sewage treatment plant and costs a lot for treating linked wastewater. In this study, a scenario with low increase of water quality when the total amount of the inflow of linked wastewater was entered into individual reactors is obtained. According to the result of modeling, The effluent water quality get the least increment once the water was introduced into the influent and anoxic tank. We generated the various scenarios Based on these results. scenarios are varying according to inflow from linked waste water's distribution ration. As a result of modeling through various scenarios, it was found that the increment of TN and TP were at the least when the inflow of linked water was distributed with ratio between sewage (80%) and oxygen-free tank (20%).

Evaluation of raw wastewater characteristic and effluent quality in Kashan Wastewater Treatment Plant

  • Dehghani, Rouhullah;Miranzadeh, Mohammad Bagher;Tehrani, Ashraf Mazaheri;Akbari, Hossein;Iranshahi, Leila;Zeraatkar, Abbas
    • Membrane and Water Treatment
    • /
    • v.9 no.4
    • /
    • pp.273-278
    • /
    • 2018
  • Due to the lack of water in arid and semi-arid areas, reuse of wastewater can be a suitable way to compensate for water scarcity. Therefore, in this research, evaluation of the quality of wastewater of Kashan Treatment Plant to use for irrigation was studied. This descriptive cross-sectional study was conducted in 2016. pH, TSS, TDS, turbidity, COD, BOD5, Total Kjeldahl Nitrogen, Total Phosphorus, Total Coliform, fecal coliform, nematode eggs of inlet and outlet of wastewater treatment plant in Kashan were studied. Mean and standard deviation and wastewater quality parameters before and after treatment were tested with SPSS 22 (2014) software. The mean wastewater output of COD, BOD5, TSS, TDS and turbidity were respectively 86.6, 41.2, 11.11, 1095 mgL-1 and 17.5 NTU and the pH was equal to 7.22. Also, the average of Total Kjeldahl Nitrogen and phosphorus were 22.4 and 2.2 mgL-1 respectively. The mean of Total Coliform and fecal coliform were 225, 161 MPN / 100 ml respectively. In addition, no nematode eggs were found in final effluent. The results indicated that the treatment plants had a significant role in the control of microbial and organic pollution load of wastewater. Also, it is concluded that all parameters were in accordance with the standards of Iran's Department of Environment, so, it can be used for unrestricted irrigation.