• Title/Summary/Keyword: Efficiency test

Search Result 5,997, Processing Time 0.038 seconds

The Evaluation of Relative Management Efficiency of Automobile Companies Using Non-parametric Approach (비모수 검정을 활용한 자동차 기업의 상대적 경영 효율성 평가)

  • Ha, Gui Ryong;Choi, Suk Bong
    • Knowledge Management Research
    • /
    • v.15 no.2
    • /
    • pp.147-164
    • /
    • 2014
  • This paper investigated the efficiency of automobile firms by using several non-parametric approaches. First, using Data Envelopment Analysis (DEA), the paper has investigated the critical factors that determine the relative efficiency of management performance in automobile companies. Second, we examined how the firm size impact on the difference of this efficiency by using Kruskl-Wallis Test. Third, by using Mann-whitney test, we also investigated the difference of the efficiency accoss existence of technological innovation activity. Finally, the paper explored the relationship between technological innovation and management efficiency by using logistic regression model. The findings of this study provided practical information for inefficient automobile firms to find benchmarking firms and strategic position to improve their efficiency. The result also provided theoretical and methodological implications for those who explore factors affecting management efficiencies. Future research directions with the limitation of the study are discussed.

  • PDF

Median Ranked Ordering-Set Sample Test for Ordered Alternatives

  • Kim, Dong-Hee;Ock, Bong-Seak
    • Communications for Statistical Applications and Methods
    • /
    • v.15 no.6
    • /
    • pp.947-957
    • /
    • 2008
  • In this paper, we consider the c-sample location problem for ordered alternatives using median ranked ordering-set samples(MROSS). We propose the test statistic using the median of samples that have the same ranked order in each cycle of ranted ordering-set sample(ROSS). We obtain the asymptotic property of the proposed test statistic and Pitman efficiency with respect to other test statistic. In simulation study, our proposed test statistic has good powers for some underlying distributions we consider.

Testing NBUCA Class of Life Distribution Using U-Test

  • Al-Nachawati, H.
    • International Journal of Reliability and Applications
    • /
    • v.8 no.2
    • /
    • pp.125-135
    • /
    • 2007
  • In this paper, testing exponentiality against new better than used in convex average and denote by (NBUCA), or its dual (NWUCA) is investigated through the U-test. The percentiles of these tests are tabulated for samples sizes n = 5(1)40. The power estimates of the test are simulated for some commonly used distributions in reliability. Pitman's asymptotic efficiency of the test is calculated and compared. Data of 40 patients suffering from blood cancer disease (Leukemia) is considered as a practical application of the proposed test in the medical sciences.

  • PDF

Catching efficiency of biodegradable trap for swimming crab (Portunus trituberculatus) in the western sea of Korea (생분해성 꽃게 통발의 어획 성능)

  • Kim, In-Ok;Lee, Gun-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.3
    • /
    • pp.262-273
    • /
    • 2014
  • To investigate the catching efficiency of a biodegradable round trap for a swimming crab (Portunus trituberculatus), four types of material (two types of biodegradable net, one type of biodegradable plus polyethylene net and one type of polyethylene net) for traps were used in the field test, and the field tests were carried out 11 times in the Boryeong fishing ground of Korea, 2012~2013. The catching efficiency of four type traps was analyzed by catch per trap, weight per trap and mean weight per individual of small and large size swimming crab. Statistical Kruskal-Wallis test was carried out to verify the significant difference for the efficiency between types of material. The catch in number of swimming crab was 9,015 and formed about 94.3% of total catch. In the results of catching efficiency of traps, there was a little difference in catch per trap, weight per trap and mean weight per individual of swimming crab in-situ data. But there was no significant difference in catching efficiency between the biodegradable traps and the PE trap (P>0.05), so it's needed to use widely a biodegradable trap for the conservation and sustainable management of swimming crab resources.

A Development of Test Method on the Energy Consumption Efficiency of Domestic Gas Boiler below 70 kW (70 kW 이하 가정용 가스보일러 에너지소비효율 실험방법 개발)

  • Park, Chanil;Kim, Laehyun
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.73-82
    • /
    • 2016
  • The energy consumption efficiency in a variety of operational test mode was considered for domestic gas boiler below 70 kW. The energy efficiency test carried out in the experimental conditions similar to the actual operation status was analyzed and compared with the current Korean efficiency test method. Four types of test modes for each boiler(Non-condensing and condensing boiler) were carried out in the condition of laboratory mode(full load, steady state) and actual operating mode. Futhermore divided into two operational status for each of these, it was applied by maximum gas consumption and consumer sales conditions. Test equipment has the function referred to gas boiler standards, such as KS or European standard EN. The equipment should be continuously measured and record the measuring factors which are the flow volume of gas and water, laboratory temperature, water flow volume for heating, return water volume after heating and quantity of the exhaust gases(CO, NO, $NO_2$). The experimental results were found that non-condensing boiler efficiency of laboratory mode is about 10% higher than that of actual mode. In case of condensing boiler, the efficiency of laboratory condition is about 20% higher than that of the actual using conditions. I suggest that the government will gradually take the efficiency test method considering the actual conditions.

Tracer Experiment and Computational Fluid Dynamics Analysis for the Drainage Efficiency of a Reservoir (배수지의 배수효율분석을 위한 추적자실험 및 전산유체해석)

  • Cho, Jung-Yeon;Go, Sun-Ho;Kwac, Lee-Ku
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.2
    • /
    • pp.22-27
    • /
    • 2017
  • During the water treatment process for household water supply, a reservoir is the last place the water is stored before being supplied to users, and the duration of the water's stay is an important factor that affects its safety. This may cause the concentration of the residual chlorine disinfectant to increase and thus lower the water's quality. The concentration and discharge efficiency of residual chlorine must be verified and managed, because these are key factors that affect the reservoir's performance. Because the actual verification test for analyzing the efficiency of a reservoir and the disinfectant's dilution capacity is difficult, simulations are generally conducted using the computational fluid analysis method. However, the simulation results require validation with experiments. The error and drainage efficiency were analyzed in this study by comparing and analyzing the actual tracer test and simulation so that the actual test for a hexagonal drainage can be replaced by the computational fluid analysis method. Based on the results of the efficiency analysis, the hexagonal reservoir was found to be appropriate, and the simulation's reliability was verified with a tracer test.

Effects of the Incidence Angle and Temperature on the Performance of a Thin-Film CIGS Solar Cell for Solar Powered UAVs (태양광무인기를 위한 박막형 태양전지의 입사각 및 온도에 따른 성능분석)

  • Shin, Donghun;Kim, Tae Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.55.2-55.2
    • /
    • 2011
  • This research aims to study the effects of the incidence angle and surface temperature on the power generation performance of a thin-film CIGS solar cell for solar powered unmanned aerial vehicles (UAVs). The test rig consists of a unit CIGS solar cell is installed on a table whose angle is controlled manually. A K-type thermocouple is attached to the solar cell surface for temperature measurements. A solar module analyzer measures the voltage and current generated from the test solar cell. The solar module analyzer also calculates the maximum solar power and efficiency of the solar cell. All test data are acquired in a PC. Test results show that the solar cell efficiency decreases significantly with increasing incidence angle and increasing surface temperature in general. As the incidence angle increases from 0 degree to 90 degree, the solar cell efficiency decreases by 60%. The solar cell efficiency decreases by 10% with increasing solar cell surface temperature from $20^{\circ}C$ to $30^{\circ}C$, for exmaple. The direct cooling method of the solar cell using dry ice decreases dramatically the solar cell surface temperature, thus increasing the solar cell efficiency by 15%.

  • PDF

Fuel Efficiency and Emission Characteristics on Aged Three-way Catalyst of LPG Vehicle (LPG 차량의 삼원촉매 노후화에 따른 연비 및 배출가스 특성)

  • Kang, Minkyung;Kwon, Seokjoo;Kim, Kiho;Seo, Youngho
    • Journal of ILASS-Korea
    • /
    • v.21 no.3
    • /
    • pp.137-143
    • /
    • 2016
  • The LPG vehicles are being operated by commercial purposes generally such as taxis. Most of taxis have a long-mileage and a harsh driving pattern. These properties may accelerate aging of the three-way catalysts much faster than the passenger vehicles. Because of this background, it was analyzed the test result of fuel efficiency and emissions on the LPG-fueled light duty vehicle. It was selected for a LPG vehicle of ULEV level to measure the fuel efficiency and emissions of the aged three-way catalysts. And the aged three-way catalysts which was driven about 300,000km and 550,000km replaced on the test vehicle in consecutive order. As a result, The aged three-way catalysts generally had no effect on fuel efficiency result, and harmful exhaust emissions had been shown to increase in most of the test mode, even though it satisfied the regulation value on most test modes.

Effect of Tip-Clearance on the Performance of a Supersonic Impulse Turbine (초음속 충동형 터빈의 팁간극에 따른 성능변화 연구)

  • Jeong, Eun-Hwan;Lee, Hang-Gi;Park, Pyun-Goo;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.117-121
    • /
    • 2008
  • The effect of tip clearance on the performance of a supersonic impulse turbine was investigated experimentally. Test was performed using high pressure air in wide ranges of pressure ratio and rotational speeds. Test revealed that efficiency gradient of the subject turbine at a reference test point was a very low value of 0.05. Turbine efficiency was varied non-linearly with respect to tip clearance. It has been found that efficiency gradient is proportional to the cube of rotational speed at a fixed turbine pressure ratio. It also has been found that efficiency gradient shows its minimum at a reference test pressure ratio irrespective of rotational speeds.

  • PDF

A study of the performance on large capacity screw compressors (중대형 스크루 압축기의 성능에 관한 연구)

  • Park, D.S.;Yang, S.H.;Lee, D.J.;Shin, J.K.;Yoo, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.668-671
    • /
    • 2001
  • For the saving of energy consumption, it is necessary that the high efficient energy transfer machine. We found the optimum operating condition of screw water chiller during this performance test. The specifications of compressor for this performance test are as follows. Built-in volume ratio; Vi=2.4, using refrigerant; HCFC-22, nominal motor output; 60kW(80Hp). We found the test results on water cooled chiller standard test condition that the evaporating capacity is increased 8% maximum and 5.6% under same operating condition. and COP is increased 11 % max. and 8% under same operating condition with change of the evaporating inlet/outlet condition. For the results of these test, we can estimate the optimum operating condition of water cooled type screw chiller.

  • PDF