• 제목/요약/키워드: Efficiency of ventilation

검색결과 402건 처리시간 0.024초

전산유체역학을 사용한 양돈장 내 작업환경 환기효율성 분석 (Analysis of Working Environment and Ventilation Efficiency in Pig House using Computational Fluid Dynamics)

  • 오병욱;이성원;김효철;서일환
    • 한국농공학회논문집
    • /
    • 제61권2호
    • /
    • pp.85-95
    • /
    • 2019
  • The internal environment in pig house is closely related to the animal productivity. In addition, it is important to consider a working environment inside the pig house due to high gas and dust concentrations. The poor working environment inside the pig house can cause health problems including respiratory diseases. To analyze the working environment, it is important to evaluate the ventilation efficiency to effectively remove harmful gases and dust. The purpose of this study is to develop a 3D CFD model to analyze the working environment in the pig house. CFD model was validated by comparing air temperature distributions between CFD computed and field measured data. The average air flow rate at the pig height was 40.1 % lower than the working height when incoming air was concentrated on upper layer by the installed ventilation system on the experimental pig house. Using the validated CFD model, the regional ventilation efficiency was computed by the TGD(tracer gas decay) method at the pig and working heights. There was a difference of ventilation efficiency on 14 % between the air stagnated section and the rest sections. Stagnated gas concentration can be effected by animal and human health.

실내 유해가스 제거효율 향상을 위한 환기성능에 관한 실험적 연구 (An Experimental Study on the Ventilation Performance to Enhance Removal Efficiency of Indoor Hamful Gases)

  • 구재현
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.117-124
    • /
    • 2009
  • 본 연구의 목적은 실내 유해가스의 제거효율 향상을 위하여 기계 환기시스템의 환기성능을 분석하는 것이다. 환기성능은 ASTM E741-83 기준에 의거하여 체강법을 사용하여 평가하였다. 추적가스($CO_2$) 기법을 사용하여 환기율과 급기/배기구 위치에 따른 환기성능이 평가되었다. 결과적으로 $CO_2$ 농도는 환기율 증가에 따라 지수적으로 감소하며 환기농도가 증가함을 파악하였다. 2종 환기방식 시스템의 환기성능이 1종 환기방식 또는 3종 환기방식 보다 더 우수하였다. 환경공조챔버에서 자연감쇠의 경우와 비교하여 급기량 570Lpm에서 1시간 후에 재실자가 없는 경우의 환기성능은 55%까지 증가하였고 1인 재실자가 있는 경우의 환기성능은 25%까지 증가하였다. 사무실에서 급기량 570Lpm인 경우 환기성능은 자연감쇠와 비교하여 15% 이상 크게 나타났다.

Effect of Contaminant Source Location on Indoor Air Quality

  • Lee, Hee-Kwan;Kim, Shin-Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제14권E호
    • /
    • pp.1-7
    • /
    • 1998
  • This paper presents an experimental study for understanding the indoor air quality in a room. A model room, which had a ceiling-mounted supply and a sidewall-mounted exhaust, was used to examine the effect of air exchange rate (AER) and contaminant source location (CSL) as a function of the elapsed time. A tracer gas method, using carbon monoxide tracer, gas analyzers, and a data acquisition system, was applied to study the ventilation air distribution and the tracer removal efficiency, so-called pollutant removal efficiency, in the model room. The experiment was composed of two parts; firstly the AER was varied to examine its effect on the ventilation air distribution and the ventilation effectiveness and secondly both AER and CSL were considered to determine their effect on the pollutant removal efficiency. It was found that the ventilation effectiveness in the model was proportional to AER but not linearly. It was also found that changing the CSL can improve the pollutant removal efficiency. In some cases, the efficiency improvement by increasing AER was achieved by simply changing CSL.

  • PDF

지하철 모사터널에서 에어커튼을 이용한 환기구의 배기효율 및 미세입자 농도 변화 연구 (The Study on Changes of Exhaust Efficiency and Fine Particle Concentration at a Ventilation Opening by a Air Curtain Flow in a Subway Model Tunnel)

  • 한방우;김학준;김용진;정상현;김용민;김종률
    • 한국대기환경학회지
    • /
    • 제27권5호
    • /
    • pp.614-622
    • /
    • 2011
  • In this study, a new tunnel ventilation method with a high velocity air curtain flow has been investigated for improving the ventilation exhaust efficiency and removing air pollutants in subway tunnels. At upper or lower position right downstream of a main duct connected with a ventilation opening, air curtain flows were suppled into the main duct where the air flow velocity was in the range of 2~6 m/s. Exhaust efficiency was monitored for both cases with and without air curtain flow for different air velocities, locations and injection angles of the air curtain. Particulate matter concentrations (PM10, PM2.5 and PM1.0) were also checked at both the main duct and ventilation opening before and after supplying air curtain flows. Lower air velocity of the main duct flow, higher air velocity of the air curtain led to higher exhaust efficiency and the air curtain condition of 30..inclined injection toward the main flow showed the maximum exhaust efficiency. The exhaust efficiency of about 24% without the air curtain could be improved to about 34% after using the air curtain flow. PM concentration decreased at the main duct and increased at the ventilation opening after using the air curtain flow. Therefore, the suggested method to use air curtain flows in tunnels will be probably one of the promising tools to reduce air pollutants in subway tunnels.

Dry Room에서 종횡비와 배기구 위치가 환기성능에 미치는 영향 (Effect of Aspect Ratio and Location of Outlets on Ventilation Performance in a Dry Room)

  • 이관수;임광옥;최석호
    • 설비공학논문집
    • /
    • 제14권4호
    • /
    • pp.324-331
    • /
    • 2002
  • The characteristics of moisture ventilation in a dry room are studied numerically The behaviors of moisture ventilation are analyzed by varying the aspect ratio of the horizontal plane and for various positions of the outlets in the room. Three different ventilation efficiencies have been used to examine the effect of the longitudinal arrangement of outlets and transverse arrangement of outlets for each aspect ratio on ventilation inside the room. It is shown that the ventilation efficiency in the dry room can be improved by arranging the outlets transversely in the cases that the aspect ratio is less than three and longitudinally in the cases that it is greater than four.

급기구 유입각도에 따른 실내 환기효율 (Indoor Ventilation Efficiency Depending on Diffuser Inlet Angle)

  • 전현준;장용준;양경수
    • 설비공학논문집
    • /
    • 제23권5호
    • /
    • pp.349-355
    • /
    • 2011
  • In this study, numerical simulation has been conducted to investigate dispersion of a pollutant released from a new furniture, a kind of Sick Building Syndrome (SBS). A sofa which generates formaldehyde is implemented by using an immersed boundary method. Large Eddy Simulation (LES) is employed to obtain time-dependent velocity and concentration fields. It is shown that the ventilation efficiency in this room can be improved by changing inlet angle of diffuser, even though other conditions still remain unchanged. Both active diffusion near a sofa and air flow pattern are important parameters to enhance the ventilation efficiency.

공간 절약형 환기덕트를 위한 챔버 개발에 관한 연구 (Development of Ventilation Duct Chamber for Reducing Space)

  • 김상진;최상식;이성
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.535-539
    • /
    • 2008
  • The machinery ventilation system in case of using the window nature ventilation is difficult due to strong outdoor wind pressure is common ventilation measure. increasing height and decreasing economical efficiency problem because of ventilation duct installation is rising and a measure is urgent. The purpose of this study is analysis required height according to each ventilation system and development of ventilation duct system to reducing height and model testing.

  • PDF

환기구 위치별 실내오염물질의 환기효과 변동에 관한 연구 (A Study on the Variation of Ventilation Effect for Indoor Air Pollutants by Ventilation Hole Sites)

  • 이정주;이주상;김신도
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.226-240
    • /
    • 1995
  • This research has a purpose to achieve experimental data used for design of ventilation systems necessary for indoor air quality control and their operation and management. For the study, spatial concentration distribution of indoor air quality according to pollutant site in a simplified model chamber. In low flow ventilation, flow pattern of indoor air was mainly influenced by diffusion and additionally, spatial distribution was formed by convection. Distribution of ventilation efficiency according to each pattern of model chamber was evaluated. It was confirmed that diffusion patterns of a pollutant among sites were formed, centering around main stream areas of supply and exhaust outlets.

  • PDF

굴착중인 장대터널 내 최적의 환기시스템에 관한 연구 (The Study on Optimum Ventilation System during Long Tunnel Construction)

  • 임한욱;오병화
    • 산업기술연구
    • /
    • 제26권A호
    • /
    • pp.3-15
    • /
    • 2006
  • To determine the optimum ventilation systems during long tunnel excavation, the velocity vector profile and the contaminant's distribution at working place are studied using 2-D, 3-D numerical analysis. The main results can be summarized as follow; In case of long tunnels, blower-exhaust-mixture types which enable to use soft blast ducts is most appropriate in terms of ventilation and economical efficiency. Of the same ventilation types, ventilation efficiency has a difference according to blast ducts and the distance between fan and working place. The 3-D numerical result shows that arranging blower and exhaust ducts in the right and left corners of the tunnel respectively is effective to discharge contaminant. The result of the real measurement shows that CO concentration can be reduced to below 50 ppm, which is regulation value, as 16-minutes fan operation goes on.

  • PDF

네트워크형 지하 도로터널 분기부에서의 환기효율 향상방안에 대한 실험적 연구 (Experimental study of improvement of ventilation efficiency at intersection in network-form underground road tunnel)

  • 이호석;홍기혁;최창림;강명구;임재범;문홍표
    • 한국터널지하공간학회 논문집
    • /
    • 제14권2호
    • /
    • pp.107-116
    • /
    • 2012
  • 네트워크형 도로터널 내 분기부 구조물과 제트팬에 의한 분기 환기효율 분석하고자 실제 도로터널을 1/45로 축소하여 실험을 수행하였다. 차량이 주행할 때 발생하는 교통관성력을 적용하기 위해 블로워 팬를 사용하여 축소모형 터널내 기류를 형성하였고, 터널의 국부적인 위치에서 속도를 측정하여 분기 효율을 연구하였다. 구조물의 특징으로 발생되는 환기 저감을 개선하기 위해 제트팬을 설치하여 터널 내 환기 효율을 최적화하였다.