• Title/Summary/Keyword: Efficiency of operations

Search Result 1,344, Processing Time 0.026 seconds

Procedural Fluid Animation using Mirror Image Method

  • Park, Jin-Ho
    • International Journal of Contents
    • /
    • v.7 no.4
    • /
    • pp.1-5
    • /
    • 2011
  • Physics based fluid animation schemes need large computation cost due to tremendous degree of freedom. Many researchers tried to reduce the cost for solving the large linear system that is involved in grid-based schemes. GPU based algorithms and advanced numerical analysis methods are used to efficiently solve the system. Other groups studied local operation methods such as SPH (Smoothed Particle Hydrodynamics) and LBM (Lattice Boltzmann Method) for enhancing the efficiency. Our method investigates this efficiency problem thoroughly, and suggests novel paradigm in fluid animation field. Rather than physics based simulation, we propose a robust boundary handling technique for procedural fluid animation. Our method can be applied to arbitrary shaped objects and potential fields. Since only local operations are involved in our method, parallel computing can be easily implemented.

The Productivity and Cost of Yarding Operations Using a Tractor-attached Winch in Pinus densiflora Stands (소나무 임분에서의 트랙터윈치를 이용한 집재작업 생산성 및 비용분석)

  • Jeong, Eung-Jin;Cho, Min-Jae;Park, Jeong-Mook;Cho, Koo-Hyun;Yoo, Young-Min;Cha, Du-Song
    • Journal of Korean Society of Forest Science
    • /
    • v.108 no.4
    • /
    • pp.574-581
    • /
    • 2019
  • The present study analyzed the productivity and cost of winching operations for evaluating the efficiency of a tractor-attached winch in a Pinus densiflora thinning site located in the Yangyang County of Gangwon-do. The mean yarding distance and mean timber volume were 29 m and 0.15 ㎥, respectively. In the 95 cycles of yarding operations, the uphill and downhill yarding operations constituted 51% and 49%, respectively, of the total yarding operations. The productivity of the uphill yarding operation was 2.28 ㎥/h, and the productivity of the downhill yarding operation was 1.89 ㎥/h. The findings of this study revealedthat productivity would increase by 0.5 ㎥/h when the rate of utilization of the machine is increased to 80% by reducing the operational delay time. The cost of the downhill yarding operation was 44,116 KRW/㎥, whereas that of the uphill yarding operation was 53,369 KRW/㎥. The difference in cost resulted from the difference in the number of yarding stems (stems/cycle). Furthermore, the results of the multiple linear regression equation developed for predicting the yarding operation times showed that productivity was significantly affected by working conditions such as yarding distance (m), the number of stems per cycle (stems/cycle), and the terrain slope (%) in the uphill and downhill yarding operations. Further research is required for developing an accurate prediction model equation according to a yarding direction.

The Determinants of The Bank Regulation and Supervision on The Efficiency of Islamic Banks in Different Country's Income Level

  • MOHD NOOR, Nor Halida Haziaton;BAKRI, Mohammed Hariri;WAN YUSOF, Wan Yusrol Rizal;MOHD NOOR, Nor Raihana Asmar;ABDULLAH, Hasni;MOHAMED, Zulkifli
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.12
    • /
    • pp.721-730
    • /
    • 2020
  • This study investigates the impact of the country's governance on the revenue efficiency of 108 Islamic banks from 26 countries offering Islamic banking and finance products services. The technical efficiencies of individual Islamic banks have been analyzed using the Data Envelopment Analysis method. The data will be pooled across the selected countries and utilize the intermediation approach. The Ordinary Least Square estimation method is employed to examine the impact of country supervision and regulation on the technical efficiency of Islamic banks. As robustness check, the study examines the impact of the level of bank regulations and supervision on the efficiency of Islamic banks operating in different income-level countries. The results found that the stricter the supervisory power, the less strict capital requirement, the tighter the restrictions on non-banking activities, and the stricter the private monitoring enhance statistically significantly the level of efficiency of Islamic banks. In upgrading the regulations and supervision of the Islamic banks, the existing regulatory framework based on the Basel Committee on Banking Supervision (BCBS) must be complemented with the prescriptions on Islamic banking or Shariah compliance diligently, so that the Islamic banks could be regulated accurately and further improve the technical efficiency of their operations.

A Wide Output Range, High Power Efficiency Reconfigurable Charge Pump in 0.18 mm BCD process

  • Park, Hyung-Gu;Jang, Jeong-A;Cho, Sung Hun;Lee, Juri;Kim, Sang-Yun;Tiwari, Honey Durga;Pu, Young Gun;Hwang, Keum Cheol;Yang, Youngoo;Lee, Kang-Yoon;Seo, Munkyo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.6
    • /
    • pp.777-788
    • /
    • 2014
  • This paper presents a wide output range, high power efficiency reconfigurable charge pump for driving touch panels with the high resistances. The charge pump is composed of 4-stages and its configuration automatically changes based on the required output voltage level. In order to keep the power efficiency over the wide output voltage range, internal blocks are automatically activated or deactivated by the clock driver in the reconfigurable charge pump minimizing the switching power loss due to the On and Off operations of MOSFET. In addition, the leakage current paths in each mode are blocked to compensate for the variation of power efficiency with respect to the wide output voltage range. This chip is fabricated using $0.18{\mu}m$ BCD process with high power MOSFET options, and the die area is $1870{\mu}m{\times}1430{\mu}m$. The power consumption of the charge pump itself is 79.13 mW when the output power is 415.45 mW at the high voltage mode, while it is 20.097 mW when the output power is 89.903 mW at the low voltage mode. The measured maximum power efficiency is 84.01 %, when the output voltage is from 7.43 V to 12.23 V.

DC-DC Converter for Low-Power Power Management IC (저-전력 전력 관리 회로를 위한 DC-DC 변환기)

  • Jeon, Hyeondeok;Yun, Beomsu;Choi, Joongho
    • Journal of IKEEE
    • /
    • v.22 no.1
    • /
    • pp.174-179
    • /
    • 2018
  • In this paper, design of high-efficiency DC-DC converter is presented for low-power PMIC (power management integrated circuit). As PMIC technologies for IoT and wearable devices have been continuously improved, high-efficiency energy harvesting schemes should be essential. Since the supply voltage resulting from energy harvesting is low and widely variable, design techniques to achieve high efficiency over a wide input voltage range are required. To obtain a constant switching frequency for wide input voltage range, frequency compensation circuit using supply-voltage variation sensing circuit is included. In order to obtain high efficiency performance at very low-power condition, accurate burst-mode control circuit was adopted to control switching operations. In the proposed DC-DC buck converter, output voltage is set to be 0.9V at the input voltage of 0.95~3.3V and maximum measured efficiency is up to 78% for the load current of 180uA.

Performance Study on Odor Reduction of Indole/Skatole by Composite

  • Young-Do Kim
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.7 no.3
    • /
    • pp.67-72
    • /
    • 2024
  • This study developed a dry composite module-type deodorization facility with Twisting airflow changes and two forms (catalyst, adsorbent) within one module. Experiments were conducted to evaluate the reduction efficiency of odor substances C8H7N and C9H9N. The device combines UV oxidation using TiO2, catalytic oxidation using MnO2, and adsorption using A/C in five different methods. Data analysis of experimental results utilized the statistical package program Python 3.12. The program applied frequency analysis of odor removal efficiency, one-way ANOVA, and post-hoc tests, with statistical significance determined by p-value to ensure reliability and validity of the measurements. Results indicated that the highest removal efficiency of C8H7N and C9H9N was achieved by the UV+A/C method, suggesting the superior effectiveness and efficiency of the developed device. Combining multiple processes and technologies within one module enhanced odor treatment efficiency compared to using a single method. The device's modularity allows for flexibility in adapting to various sewage treatment scenarios, offering easy maintenance and cost-effective deodorization. This composite reaction module device can apply multiple technologies, such as biofilters, plasma, activated carbon filters, UV-photocatalysis, and electromagnetic-chemical systems. However, this study focused on UV-photocatalysis, catalysts, and activated carbon filters. Ultimately, the research demonstrates the practical applicability of this innovative device in real sewage treatment operations, showing excellent reduction efficiency and effectiveness by integrating UV oxidation, TiO2 photocatalysis, MnO2 catalytic oxidation, and A/C adsorption within a modular system.

The Efficiency and Determinants of 4 Major Container Ports in Korea (국내 주요 4대 컨테이너항만의 효율성 및 결정요인 분석)

  • Park, Ho;Kim, Dongjin
    • Journal of Korea Port Economic Association
    • /
    • v.28 no.3
    • /
    • pp.73-89
    • /
    • 2012
  • As the environment surrounding ports is rapidly changing and ports competition in Southeast Asia has become more severe to secure cargo volumes, ports strive to enhance their competitiveness by improving the efficiency of operations. The operational efficiency of ports, plays a crucial role to improve a nation's. This study aims to analyze the efficiency of container port and its determinants during over five year(2006 to 2010) period using DEA-O and Tobit regression respectively. The results show that firstly, Gamman is the most efficient container terminal, followed by New Gamman container terminal and Hutchison Busan container terminal. Secondly, it is notable that the efficiency of Busan Newport is dramatically increasing, and finally, the yard productivity of the container port is only influencing determinant of all.

A Study on the Investment Portfolios of Stocks using DEA (DEA를 활용한 주식 포트폴리오 구성에 관한 연구)

  • Gu, Seung Hwan;Jang, Seong Yong
    • Korean Management Science Review
    • /
    • v.31 no.3
    • /
    • pp.1-12
    • /
    • 2014
  • This study suggests the two types DEA models such as DEA CCR model and Super Efficiency model to evaluate the value of a company and to apply them for the investments. 14 kinds of real data of companies such as EV/EBITDA, EPS growth rate, PCR, PER, dividend yield, PBR, stock price/net current asset, debt ratio, current ratio, ROE, operating margin, inventory turnover, accounts receivable turnover, and sales growth ratio were used as input variables of DEA models. 12 year data from December 30, 2000 up to December 30, 2012 were collected, and the data with negative, missing and 0 values were removed reflecting the characteristics of the DEA. In order to verify the effectiveness of the models, we compared the historical variability and rate of return of both models those of the market. Study results are as follows. First, two DEA models are more stable than market in terms of rate of return because the historical variability of both models are less than that of market. Second, Super Efficiency model is more stable than CCR model. Lastly, the cumulative rate of return of Super Efficiency model (434%) is greater than that of the CCR model (420%) and that of the market (269%).

Optimal Configuration of Distribution System considering the Economic Operations of a Microgrid

  • Moon, Hyun-Ho;Lee, Jong-Joo;Choi, Sang-Yule;Shin, Myong-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.7
    • /
    • pp.20-25
    • /
    • 2010
  • With the diversification of distribution facilities, existing distributed generation can be subdivided into Microgrids, which are smaller units for application. These Microgrids, subdivided as such and connected to distribution systems, should operate under driving plans that will ensure their economic efficiency and, accordingly, the configuration of those distribution systems that include Microgrids should also be changed. The perception of the necessity to secure the economic efficiency of distribution systems is gradually increasing and studies intended to assess the economic efficiency of Microgrids and Smartgrids are ongoing. In this paper, the power generation capacity of an economically operative Microgrid was calculated using the MonteCarlo simulation, which is a method based on the probability theory considering the power generation cost of Microgrids linked with power supply systems and reverse sales costs, etc., and an optimum distribution systems was configured based on the results of these calculation.

A Study on PFC AC-DC Converter of High Efficiency added in Electric Isolation (절연형 고효율 PFC AC-DC 컨버터에 관한 연구)

  • Kwak, Dong-Kurl;Kim, Sang-Roan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1349-1355
    • /
    • 2009
  • This paper is studied on a novel power factor correction (PFC) AC-DC converter of high efficiency by soft switching technique. The input current waveform in the proposed converter is got to be a sinusoidal form composed of many a discontinuous pulse in proportion to the magnitude of a ac input voltage under the constant switching frequency. Therefore, the input power factor is nearly unity and the control method is simple. The proposed converter adding an electric isolation operates with a discontinuous current mode (DCM) of the reactor in order to obtain some merits of simpler control, such as fixed switching frequency, without synchronization control circuit used in continuous current mode (CCM). To achieve the soft switching (ZCS or ZVS) of control devices, the converter is constructed with a new loss-less snubber for a partial resonant circuit. It is that the switching losses are very low and the efficiency of the converter is high, Particularly, the stored energy in a loss-less snubber capacitor recovers into input side and increases input current from a resonant operation. The result is that the input power factor of the proposed converter is higher than that of a conventional PFC converter. This paper deals mainly with the circuit operations, theoretical, simulated and experimental results of the proposed PFC AC-DC converter in comparison with a conventional PFC AC-DC converter.