• 제목/요약/키워드: Efficiency grade standard

검색결과 36건 처리시간 0.028초

농촌주택표준설계도 에너지효율등급평가 및 설계변수에 따른 에너지소요량 변화에 관한 연구 (A Study on Energy Requirement Variation According to Energy Efficiency Rating Evaluation and Design Variable of Standard Design of Rural Houses)

  • 박미란;류연수;최정만;서혜원
    • 한국농촌건축학회논문집
    • /
    • 제19권2호
    • /
    • pp.9-16
    • /
    • 2017
  • The study analyzed the heat losses and the building energy efficiency grade by the energy simulation using the ENERGY# and ECO2 programs for the three types of Standard design of rural houses. It was calculated the energy efficiency rating by the ECO2 program for the rural housing standard design, and the energy demand and the energy consumption by each factor were compared and analyzed. And it analyzed energy consumption by element of each house by ENERGY # program. As a result, first in the evaluation of the energy efficiency grade of buildings by the ECO2 program, the rating for primary energy requirement for the housing newly built by the standard design of rural house is expected to range from 2 to 4 with 189.3 to $238.7kWh/m^2.a$. Second, the energy loss of each part of standard design of rural housing occurs in the order of ventilation 39%, window 33%, outer wall 14%, roof 9%, bottom 5%, and energy loss through ventilation and window occurs more than 70%. Third, the most beneficial effects on the energy efficiency grade is obtained the lowest grade of all three types by 2 when the lowering of the window and door heat transmission rate and the lowering of the light density, and the heat exchange ventilation device is not installed. Fourth, in the standard design of rural housing, the energy demand is occupied by heating > hot water > lighting order, and the order of the weight is changed in order of heating > lighting > ventilation > hot water. Fifth, building energy efficiency assessment system needs to establish policy for fixing rural housing energy as a practical device to ensure energy performance and quality.

전자사진 기술을 사용하는 이미징 장치의 에너지 효율 기준 연구 (Energy efficiency standard for imaging equipments using electrophotograph printing)

  • 박준영;윤원식
    • 한국정보통신학회논문지
    • /
    • 제18권10호
    • /
    • pp.2433-2442
    • /
    • 2014
  • 본 논문에서는 전자사진 기술을 이용하는 프린터, 복사기, 팩시밀리, 복합기 등과 같은 이미징 장치의 효율등급기준에 대한 연구를 수행하였다. 대기전력을 관리하고 있는 현 제도의 문제점을 파악하고 효율관리 필요성을 제안하였으며, 이를 위한 효율 기준을 국내 대기전력저감 프로그램에 등록된 실증 데이터를 기반으로 개발하였다. 효율부여지표를 찾기 위해 상관분석(Correlation Analysis)을 실시하였으며, 인쇄 속도가 가장 큰 상관계수(Correlation Coefficient)를 가짐을 확인하였다. 이를 적용한 복합기, 프린터에 대한 1~5 등급의 효율등급 기준과 에너지 프론티어 기준을 도출하였으며, 정책반영 시 연간 약 650 억 원의 에너지 비용을 절감할 것으로 기대한다.

Classification Index and Grade Levels for Energy Efficiency Classification of Agricultural Dryers in Korea

  • Shin, Chang Seop;Park, Jin Geun;Kim, Kyeong Uk
    • Journal of Biosystems Engineering
    • /
    • 제39권2호
    • /
    • pp.96-100
    • /
    • 2014
  • Purpose: The objective of this study was to develop a classification index and the grade levels for a five-grade energy efficiency classification of agricultural dryers in Korea. Methods: The classification index and the grade levels were determined by using the performance test data published by the FACT over the last eight years to reflect a state of the art technology for agricultural dryers in Korea. The five grades were designed to have the classified dryers distributed normally over the grades with 15% for the $1^{st}$ grade, 20% for the $2^{nd}$ grade, 30% for the $3^{rd}$ grade, 20% for the $4^{th}$ grade and 15% for the $5^{th}$ grade. Results: The classification index was defined as the total amount of fuel and electrical energy consumed per 1% of the wet basis moisture content evaporated from a unit mass of grain or agricultural crops during the drying process: 1 MT of paddy rice for grain dryers and 1 kg of red pepper for agricultural crop dryers as the standard mass. Conclusions: The grade levels for the five-grade energy efficiency classification of grain dryers, kerosene dryers, and electric dryers were proposed in terms of the classification index value.

Study on the grading standard of Panax notoginseng seedlings

  • Chen, Lijuan;Yang, Ye;Ge, Jin;Cui, Xiuming;Xiong, Yin
    • Journal of Ginseng Research
    • /
    • 제42권2호
    • /
    • pp.208-217
    • /
    • 2018
  • Background: The quality differences in seedlings of medicinal herbs often affect the quality of medicinal parts. The establishment of the grading standard of Panax notoginseng seedlings is significant for the stable quality of medicinal parts of P. notoginseng. Methods: To establish the grading standard of P. notoginseng seedlings, a total of 36,000 P. notoginseng seedlings were collected from 30 producing areas, of which the fresh weight, root length, root diameter, bud length, bud diameter, and rootlet number were measured. The K-means clustering method was applied to grade seedlings and establish the grading standard. Results: The fresh weight and rootlet number of P. notoginseng seedlings were determined as the final indices of grading. P. notoginseng seedlings from different regions of Yunnan could be preliminarily classified into four grades: the special grade, the premium grade, the standard grade, and culled seedlings. Conclusion: The grading standard was proven to be reasonable according to the agronomic characters, emergence rate, and photosynthetic efficiency of seedlings after transplantation, and the yields and contents of active constituents of the medicinal parts from different grades of seedlings.

중소형화재실험을 이용한 외단열 시스템(EIFS) 화재위험성평가에 관한 연구 (A Study on the Fire Risk Assessment of EIFS by Cone Calorimeter Test & Single Burning Item Test)

  • 민세홍;김미숙
    • 대한안전경영과학회지
    • /
    • 제12권1호
    • /
    • pp.1-9
    • /
    • 2010
  • Recently, in circumstantial situation it is recommended positively to utilize of EIFS(Exterior Insulating and Finishing System) as energy policy for economizing energy. But internal EPS insulators of EIFS are exterior panel of high fire risk, because of constituting of flammable materials to be fragile in fire. In this study, fire risk is assessed by experiment Con Calorimeter test and SBI(Single Burning Item) test. As the result of experiment, Con Calorimeter tests do not reach to capability standard of internal incombustible grade, and are assessed as low grade in SBI incombustible grade. Because EIPS is exterior material in buildings with high fire risk in spite of good efficiency, it is required rapidly to take measures to meet situation through various studies(for instance, adjusting law regulation, etc.) in the future.

Where's the Procedural Fluency?: U.S. Fifth Graders' Demonstration of the Standard Multiplication Algorithm

  • Colen, Yong S.;Colen, Jung
    • 한국수학교육학회지시리즈D:수학교육연구
    • /
    • 제24권1호
    • /
    • pp.1-27
    • /
    • 2021
  • For elementary school children, learning the standard multiplication algorithm with accuracy, clarity, consistency, and efficiency is a daunting task. Nonetheless, what should be our expectation in procedural fluency, for example, in finding the product of 25 and 37 among fifth grade students? Collectively, has the mathematics education community emphasized the value of conceptual understanding to the detriment of procedural fluency? In addition to examining these questions, we survey multiplication algorithms throughout history and in textbooks and reconceptualize the standard multiplication algorithm by using a new tool called the Multiplication Aid Template.

1급 응급구조사의 비디오후두경 기관삽관과 직접후두경 기관삽관의 신속성 및 정확도 비교 (Comparison of Video Laryngoscope and Direct Laryngoscope on Rapidity and Accuracy in Tracheal Intubation by Paramedic)

  • 심규식
    • 한국응급구조학회지
    • /
    • 제14권1호
    • /
    • pp.5-18
    • /
    • 2010
  • Objective : This study compares Video laryngoscope and Direct laryngoscope in tracheal Intubation on rapidity and accuracy by paramedic and aims to improve efficiency of airway management and survival rate in pre-hospital treatment for the patients with severe trauma, cardiac arrest or dyspnea caused by acute diseases. Methods : 60 paramedics were recruited from 13 fire stations located in C province. With the consent of the paramedics, likelihood ratio test was carried out and they were divided into two different groups; DL group (30) and GVL group (30). Regarding intubation conditions, difficult airway grade I, grade II and grade III as well as sniffing position and neutral position were examined. This study also compared between ambulance in motion and in stand still. Frequency, average and standard deviation were analyzed with statistics program, SPSS WIN 17.0 and repeated measure design was introduced to examine inter-relations between position, grade and groups. Results : Intubation was performed more rapidly in neutral position and GVL than in sniffing position and DL(F = 15.260, p = .000). Rapidity value was better with grade I and grade II than grade III and better with GVL than DL(F = 32.629, p = .000). Accuracy value was higher with neutral position and GVL than sniffing position and DL(F = 5.008, p = .011). grade III was less accurate than grade I, grade II and GVL was more accurate than DL(F = 10.966, p = .000). Ambulance motion status did not show any statistically significant differences in accuracy and rapidity. Conclusion : Given this study results, neutral position is better for the patient with severe trauma. For a better survival, GVL intubation can be considered since GVL can enhance accuracy as well as rapidity regarding difficult airway. Since there is no significant differences in ambulance motion factors, intubation can be recommended even in moving ambulance for shortening traveling time to a hospital.

  • PDF

병원 간호등급에 따른 간호수행 정도 (Evaluation on the Performance of Nursing in according to the Nursing grade of Hospitals)

  • 윤순길;박재용;김기훈;한창현
    • 한국병원경영학회지
    • /
    • 제15권3호
    • /
    • pp.1-16
    • /
    • 2010
  • As a cross-sectional study, this study was aimed to investigate and compare the job efficiency and satisfaction of nurses according to the hospital grade. Survey was conducted by mail on June 2009, and the respondents were 1,016 nurses working in 15 hospitals which are 9 high-grade general hospitals and 6 general hospitals. The percent of nurses acknowledging their hospital grades is 34.5%, and that is 20.5% at high-grade general hospitals. As the result of review of studies, it is concluded that under the circumstance that differential rates are contracted to calculate fees for hospital services and copayment of patients are according to nursing grades and hospital grades, the degree of nurses' awareness of insurance fees impact on their performance like recording of care and prescription. In order to improve nurses' performance, they need to be educated about the national insurance fee system. In hospitals with higher nursing grade and more beds, the levels of nursing quality and faithfulnes and their job satisfaction were higher. Nurses' awareness of their hospital nursing grade was related to the quality of nursing but not the faithfulness. Nurses working in higher nursing-grade hospital are more self-respect and satisfied at their jobs, and their job efficiencies are not significantly different. The current nursing fees based on the proper number of nurses per beds of nursing units should be changed to be based on the amount of job per nurse by their nursing protocol, and the nurse staffing standard should be differentiated between nursing grades. As the aspect of nursing, 24-hours patient care, it is difficult to improve nurses' job satisfaction, and in the other hand, that tends to depend on their income level. In the current circumstance, comprehensive research is required to investigate the propriety of 25% of the inpatient fees as the nursing management charge.

  • PDF

Online analysis of iron ore slurry using PGNAA technology with artificial neural network

  • Haolong Huang;Pingkun Cai;Xuwen Liang;Wenbao Jia
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2835-2841
    • /
    • 2024
  • Real-time analysis of metallic mineral grade and slurry concentration is significant for improving flotation efficiency and product quality. This study proposes an online detection method of ore slurry combining the Prompt Gamma Neutron Activation Analysis (PGNAA) technology and artificial neural network (ANN), which can provide mineral information rapidly and accurately. Firstly, a PGNAA analyzer based on a D-T neutron generator and a BGO detector was used to obtain a gamma-ray spectrum dataset of ore slurry samples, which was used to construct and optimize the ANN model for adaptive analysis. The evaluation metrics calculated by leave-one-out cross-validation indicated that, compared with the weighted library least squares (WLLS) approach, ANN obtained more precise and stable results, with mean absolute percentage errors of 4.66% and 2.80% for Fe grade and slurry concentration, respectively, and the highest average standard deviation of only 0.0119. Meanwhile, the analytical errors of the samples most affected by matrix effects was reduced to 0.61 times and 0.56 times of the WLLS method, respectively.

척도운용체계를 통해 본 18세기 화성건축의 건축구성에 관한 연구 (A Study on the Operating System of the Architectural Standard Scale of Length(尺度, Korean foot) used in the Hwasong City Wall in the 18th Century)

  • 이호락;이상해
    • 건축역사연구
    • /
    • 제6권2호
    • /
    • pp.65-77
    • /
    • 1997
  • The Hwasong City Wall was built for three years(1794-1796), but the real construction term was taken only 28 months. The wall and the buildings on the wall were built simultaneously, and the esttimated construction cost was highly restricted. These conditions were main factors for considering the high efficiency of construction productivity. This study examines these factors that are reflected in the operating system of the architectural standard scale of length, the architectural composition system in the Hwasong City Wall to reduce the construction cost. Through the study, following factors are found. 1.The rule of multiple proportion is found in the relationship between the partition distance, that is, span and the height of the girder which is related to the productivity of ready-made building members. 2.The ruling grade system of scale in the component members is found in the chang-bang(창방, penetration members)

  • PDF