• Title/Summary/Keyword: Efficiency calibration

Search Result 333, Processing Time 0.027 seconds

Seamless Superimposition Technique of Virtual Objects for AR System of Excavator Based on Image Processing (굴삭기 AR 시스템을 위한 이미지 프로세싱 기반 가상 이미지 중첩 기술)

  • Lee, Kanghyeok;Park, Joohwan;Kang, Hojun;Shin, Dohyoung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.2
    • /
    • pp.21-29
    • /
    • 2017
  • Recently, with having a great interest of the general public for the AR (Augmented Reality) technology, there have been lots of study to improve efficiency of a construction equipment with applying the AR technology to a construction equipment. The clear extrinsic calibration is essential to applying AR technology at the construction site without any error which came from superimposition between 'Real world' and 'Virtual world'. However, on the construction site, the clear extrinsic calibration is not possible, because of lack of time and budget for the specific survey, also, the huge error of the outdoor tracking system such as gyro, GPS system and so on. In this study, we do research about seamless superposition with unclear extrinsic calibration and the image process method for making AR navigator operating in the excavator. Based on this study, we figure that we can fully develop the AR navigator for the excavator. Furthermore, thereby operating AR navigator at many construction sites, we expect that the efficiency of the excavator will be improved. In addition, we can develop AR navigator for not only a excavator but all about construction equipment.

Measurement of Detection Efficiency of Plastic Track Detector to ${\alpha}-particle$ (고체비적검출기의 알파선 검출효율 측정에 관한 연구)

  • Park, Young-Woong;Yang, Hyun-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.3
    • /
    • pp.167-173
    • /
    • 1996
  • The calibration method for the detection efficiency of solid state track detector to alpha is presented, and the detection efficiency of CN-85 and LEXAN to alpha is measured by this method. The results are 97% and 57% in CN-85 and LEXAN, respectively. The reason for a better result in CN-85 in not only the high sensitivity but also the low energy dependency with comparing for LEXAN. The peak detection efficiency is 3MeV and 1.8MeV in CN-85 and LEXAN, respectively.

  • PDF

A Study on Accuracy Evaluation and Accuracy Improvement in Cadastral Re-survey Surveying Method (지적재조사 측량방법의 정확도 비교 및 정확도 향상방안 연구)

  • Lee, Suk Bae;Auh, Su Chang;Suh, Yong Woon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.4
    • /
    • pp.39-46
    • /
    • 2014
  • Network RTK GNSS positioning technique which has been developed to overcome the limitation of Single reference station RTK is used widely in the field of general surveying, cadastre surveying and engineering surveying due to the high accuracy and efficiency. It is specified Network RTK, Single reference station RTK and Static of GNSS as a surveying method in the regulation of Cadastre Re-survey Surveying. In this study, Network RTK and Static GNSS surveying were accomplished at cadastral re-survey field in Hadong, Gyeongnam and the surveying results were compared. Also, to analyze the performance of site calibration in Network RTK surveying, two types of Network RTK surveying with and without site calibration were accomplished and the results was compared. The research result shows that average positioning error between Network RTK(VRS) without site calibration and Static surveying result is 2.44cm and 1.53cm respectively and average positioning error between Network RTK(VRS) with site calibration and Static surveying result is 0.19cm and 0.82cm respectively at two zone. So, it was proved the effect of calibration in network RTK(VRS) surveying.

Application of SWAT-CUP for Streamflow Auto-calibration at Soyang-gang Dam Watershed (소양강댐 유역의 유출 자동보정을 위한 SWAT-CUP의 적용 및 평가)

  • Ryu, Jichul;Kang, Hyunwoo;Choi, Jae Wan;Kong, Dong Soo;Gum, Donghyuk;Jang, Chun Hwa;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.347-358
    • /
    • 2012
  • The SWAT (Soil and Water Assessment Tool) should be calibrated and validated with observed data to secure accuracy of model prediction. Recently, the SWAT-CUP (Calibration and Uncertainty Program for SWAT) software, which can calibrate SWAT using various algorithms, were developed to help SWAT users calibrate model efficiently. In this study, three algorithms (GLUE: Generalized Likelihood Uncertainty Estimation, PARASOL: Parameter solution, SUFI-2: Sequential Uncertainty Fitting ver. 2) in the SWAT-CUP were applied for the Soyang-gang dam watershed to evaluate these algorithms. Simulated total streamflow and 0~75% percentile streamflow were compared with observed data, respectively. The NSE (Nash-Sutcliffe Efficiency) and $R^2$ (Coefficient of Determination) values were the same from three algorithms but the P-factor for confidence of calibration ranged from 0.27 to 0.81 . the PARASOL shows the lowest p-factor (0.27), SUFI-2 gives the greatest P-factor (0.81) among these three algorithms. Based on calibration results, the SUFI-2 was found to be suitable for calibration in Soyang-gang dam watershed. Although the NSE and $R^2$ values were satisfactory for total streamflow estimation, the SWAT simulated values for low flow regime were not satisfactory (negative NSE values) in this study. This is because of limitations in semi-distributed SWAT modeling structure, which cannot simulated effects of spatial locations of HRUs (Hydrologic Response Unit) within subwatersheds in SWAT. To solve this problem, a module capable of simulating groundwater/baseflow should be developed and added to the SWAT system. With this enhancement in SWAT/SWAT-CUP, the SWAT estimated streamflow values could be used in determining standard flow rate in TMDLs (Total Maximum Daily Load) application at a watershed.

Construction of small hydropower facilities performance evaluation system (소수력 발전설비 성능평가 시스템 구축)

  • Kim, Youngjoon;Kim, Yongyeol;Cho, Yong;Ko, Jaemyoung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.193.2-193.2
    • /
    • 2010
  • Domestic hydroelectric power plants has been manufactured as the design condition by the demand. Hydraulic turbine power plants operating at appointed load shall be operate stable in terms of pressure, discharge, rotational speed and torque. A performance guarantees for hydro turbines shall be contain, as a minimum, guarantees covering power, discharge and specific hydraulic energy, efficiency, maximum momentary overspeed and maximum momentary pressure and maximum steady-state runaway speed, as well as guarantees related to cavitation. But, present in Korea, the absence of testing laboratories and technical criteria for the performance test of small hydropower degrades the efficiency of the domestic hydropower machines, and makes it difficult to objectively evaluate the performance of hydro turbine. Therefore We planned making a basis of performance test of small hydropower turbine by using our flowmeter calibration system the largest one in Korea. We planned the maximum measurable power of hydro turbine will be 200 kW in our system.

  • PDF

Development of an Automated Diffusion Scrubber-Conductometry System for Measuring Atmospheric Ammonia

  • Lee, Bo-Kyoung;Lee, Chong-Keun;Lee, Dong-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.6
    • /
    • pp.2039-2044
    • /
    • 2011
  • A semi-continuous and automated method for quantifying atmospheric ammonia at the parts per billion level has been developed. The instrument consists of a high efficiency diffusion scrubber, an electrolytic on-line anion exchange device, and a conductivity detector. Water soluble gases in sampled air diffuse through the porous membrane and are absorbed in an absorbing solution. Interferences are eliminated by using an anion exchange devises. The electrical conductivity of the solution is measured without chromatographic separation. The collection efficiency was over 99%. Over the 0-200 ppbv concentration range, the calibration was linear with $r^2$ = 0.99. The lower limit of detection was 0.09 ppbv. A parallel analysis of Seoul air over several days using this method and a diffusion scrubber coupled to an ion chromatography system showed acceptable agreement, $r^2$ = 0.940 (n = 686). This method can be applied for ambient air monitoring of ammonia.

Construction of small hydropower facilities performance evaluation system (소수력 발전설비 성능평가 시스템 구축)

  • Kim, Youngjoon;Cho, Yong;Ko, Jaemyoung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.206.2-206.2
    • /
    • 2011
  • Domestic hydroelectric power plants has been manufactured as the design condition by the demand. Hydraulic turbine power plants operating at appointed load shall be operate stable in terms of pressure, discharge, rotational speed and torque. A performance guarantees for hydro turbines shall be contain, as a minimum, guarantees covering power, discharge and specific hydraulic energy, efficiency, maximum momentary overspeed and maximum momentary pressure and maximum steady-state runaway speed, as well as guarantees related to cavitation. But, present in Korea, the absence of testing laboratories and technical criteria for the performance test of small hydropower degrades the efficiency of the domestic hydropower machines, and makes it difficult to objectively evaluate the performance of hydro turbine. Therefore We planned making a basis of performance test of small hydropower turbine by using our flowmeter calibration system the largest one in Korea. We planned the maximum measurable power of hydro turbine will be 200 kW in our system.

  • PDF

Assay Method for Lectin-conjugated Ellagitannin Encapsulated in Liposomal Formulations (리포좀 제제 중 렉틴-엘라지탄닌 포합체의 분석법 확립)

  • Jeon, Hyun-Joo;Choi, Young-Wook
    • Journal of Pharmaceutical Investigation
    • /
    • v.31 no.3
    • /
    • pp.197-200
    • /
    • 2001
  • Lectin-conjugated ellagitannin (LET), a newly introduced melanoma-specific antitumor agent which has been synthesized by conjugation of wheat germ agglutinin as a lectin with praecoxin A as an ellagitannin, was encapsulated into sterically stabilized liposomes (SSL). Modified Folin phenol method was established for the quantitation of LET contents in liposomal formulations protein employing the standard calibration curve with bovine serum albumin. After removal of phospholipid by organic solvent extraction, which interferes the specific selectivity of the Folin-Ciocalteu reagent with the protein, recovery of LET was $94.5{\pm}2.3%$ and the encapsulation efficiency was revealed as $37.8{\pm}5.9%$ for 2.5 mg/ml LET solution.

  • PDF

A Measuring Data Calibration Technique for Measurement and Verification of Energy-Efficiency Programs (효율향상 프로그램의 성과계량검증을 위한 계측자료 보정 기법)

  • Cho, Ki-Seon;Park, Jong-Jin;Rhee, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.834-836
    • /
    • 2005
  • This paper describes algorithms for enhancing the reliability of measurements to verify the performance of energy efficiency programs with an simple method. Fundamentally, measurements contain erroneous data because of the various causes. and so proper procedures or schemes are prepared before the performance is evaluated. In this paper, we propose an approach for detecting and correcting an adulterate data, such as missing and bad data. Erroneous data are detected or corrected by pre-described measuring conditions, ensemble average, and standard deviation of measurements at measuring time. The proposed algorithms are tested by field test measurements. From case studies we drew the promising results.

  • PDF

Experimental Study on the Temperature Distribution and CO, NOx Emission of Porous Ceramic Oil Burner (다공 세라믹 오일 연소기의 온도분포 및 CO, NOx 배출 특성에 관한 실험적 연구)

  • Cho, J.D.;Kang, J.H.;Lim, I.G.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.398-403
    • /
    • 2000
  • Experimental study on the porous ceramic burner for oil burning has been performed. Temperature profile of the combustor and CO and NOx emission have been obtained for with and without porous ceramic plate. It is found that very uniform and high temperature region with porous ceramic plate can be realized due to high radiation emission from the plate and also obtained lower CO and soot particulate emission, when compared to the conventional burner. When this burning method is applied to conventional boiler of small heating capacity, it is found that near 6 and 7 percent increase in thermal efficiency could be obtained without a proper calibration for optimization.

  • PDF