환기관점에서 본 열교환 환기유니트 (Consideration of Heat Recovery Ventilator from Ventilating Standpoint)

  • 송준원;강일경;김태희;신용섭;박재성;최원영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.417-422
    • /
    • 2006
  • On trends of 'well-being', heat recovery ventilators(HRV) are recently installed in high rise buildings. HRV is not energy saving instrument but ventilating one. But many people have not been aware of the accurate fact. In this study, performances of HRV are tested under foreign and domestic standards. Especially air-tightness is measured three times by using gas concentration method and pressing equipment. Wet effective ventilating air volume is acquired by solving gas concentration equations. After research air-tightness and effective ventilating air volume must be more focused on than heat transfer efficiency to select the optimal HRV. Heat transfer efficiency must be adjusted by air-tightness results.

  • PDF

폐쇄공간 화재 발생시 온도 및 연소산화물의 분포에 관한 모델 해석 (A Numerical Analysis of the Distribution of Temperature and Combustio Products I case of Compartment Fire)

  • 차형석;이희근
    • 터널과지하공간
    • /
    • 제8권1호
    • /
    • pp.8-16
    • /
    • 1998
  • The first purpose of this study is to verify the application of computer modelling to a enclosed space fire. The second one is to determine temperature distribution for the three different ventilation types in case of a enclosed space fire. The third one is to find out the ventilation direction and ventilation quantity to remove effectively heat and combustion products generated by a fire in variable air volume(VAV) system. Firstly, compared with experimental results of Lawrence Livermore National Laboratory(LLNL), numerical results show good agreements. Secondly, among three different ventilation types, the numerical analyses show the highest temperature distribution in occupied zone(up to 1.8 m from bottom) from firing moment to 100 sec. when supply ducts are placed in ceiling and extract duct is placed close to the bottom on side walls. This is due to disadvantageous position of extract duct in ventilating high temperature air which rise because of buoyancy force. Thirdly, this study finds out effective ventilation direction and ventilation quantity to remove heat and combustion products generated by a fire by using VAV system. $CO_2$ concentration is used as a fire fume removal index. As soon as a fire happens, ventilation direction is changed in order to gather and drive out fire fumes. In case of three times ventilation quantity of ordinary one, $CO_2$ concentration and temperature have begun to decrease at 120 sec. after firing, i.e.fire fumes have begun to be removed.

  • PDF

유리섬유 및 알루미늄 금속 혼합물 유리조성 개발 (Development on Glass Formulation for Aluminum Metal and Glass Fiber)

  • 조현제;김천우
    • 방사성폐기물학회지
    • /
    • 제10권4호
    • /
    • pp.247-254
    • /
    • 2012
  • 원전에서 발생되는 방사성폐기물에 대한 고화처리 방법 중 하나인 유리화기술이 일부 가연성폐기물에 대해 적용되고 있다. 국내외적으로 중저준위 방사성폐기물의 효과적인 감용과 안정적인 처분을 위해 다양한 폐기물에 대한 유리화기술 적용방안이 확대 연구되고 있으며, 최근에는 가연성폐기물 뿐만 아니라 알루미늄 금속과 같은 비가연성폐기물에도 유리화 연구가 활발하게 진행되고 있다. 공기조화계통 (HVAC)에는 주로 필터가 이용되고 있으며, 사용 후 필터는 여과재 (유리섬유 및 알루미늄)를 이용하여 배기체를 흡착하기 때문에 방사성폐기물로 처리가 되어야 한다. 본 연구는 필터에 대한 처리기술 연구를 위해 유도가열식 저온용융로 (Cold Crucible Induction Melter: CCIM)를 이용한 유리화 타당성 연구를 수행하였다. 사용후 필터에 대한 유리화 (Vitrification)는 먼저 유리섬유 및 알루미늄 함량을 고려한 최적의 유리조성을 개발 하였으며, 개발된 유리 조성을 이용하여 최적의 폐기물 저감을 위한 용융변수와 최종 생성된 유리고화체의 특성을 분석하였다. 사용후 필터 유리화용 조성유리는 주로 $SiO_2$$B_2O_3$로 구성되어 있다. 전기로를 이용한 용융물 특성시험에서는 폐기물 투입률 및 최종 생성물인 유리고화체의 특성이 검토되었다. 본 연구에서는 알루미늄 금속과 유리섬유로 구성된 필터에 대한 유리조성 개발과 이를 통해 생성된 유리고화체의 물리화학적 특성을 검토하고 유리화 타당성을 확인하였다.