• 제목/요약/키워드: Effective thermal capacity

검색결과 91건 처리시간 0.026초

금속분말 사출성형 제품의 공정능력분석에 관한 연구 (A Study on the Process Capability Analysis of MIM Product)

  • 최병기;이동길;최병희
    • 한국생산제조학회지
    • /
    • 제19권1호
    • /
    • pp.57-64
    • /
    • 2010
  • Metal Injection Molding (MIM) is attractive because it produces consistent, complex-geometry components for high-volume, high-strength, and high-performance applications. Also MIM using in optical communication field, display field, and semi-conductor field is a cost-effective alternative to metal machining or investment casting parts. It offers tremendous single-step parts consolidation potential and design flexibility. The objective of this paper is to study the suitability of design, flow analysis, debinding and sinterin processes, and capability analysis. The suitable injection conditions were 0.5~1.5 second filling time, 11.0~12.5 MPa injection pressure derived from flow analysis. The gravity of the product is measured after debinding an sintering. The maximum and minimum gravity levels are 7.5939 and 7.5097. the average and standard deviation are 7.5579 and 0.0122; when converted into density, the figure stands at 98.154%. According to an analysis of overall capacity, PPM total, which refers to defect per million opportunities(DPMO), stands at 166,066.3 Z.Bench-the sum of defect rates exceeding the actual lowest and highest limits-is 0.97, which translates into the good quality rate of around 88.4% and the sigma level of 2.47.

지하수 히트펌프 시스템의 대수층 활용 사레 연구 (Study on the aquifer utilization for a ground water heat pump system)

  • 심병완;이철우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.32-35
    • /
    • 2006
  • The validation of a groundwater source heat pump system installation site is estimated by bydrogeothermic model ing. The hydraulic characteristics of the aquifer system is evaluated from pumping and recovery tests. In addition, the temperature distribution by the pumping and the injection of groundwater, and water level fluctuations are simulated by numerical modeling. The total cooling and heating load for the building is designed as 120RT(refrigeration ton) and the ground water source heat pump system covers 50RT as a subsidiary system The scenario of heat pump operation is organized as pumping and inject ion of groundwater that is performed for 8 hours per day in cooling mode for 90 days during the summer season The heat transfer by the injected warm water is limited near the inject ion wells in the simulated temperature distribution. The reason is that the given operation time is too short to expect broad thermal diffusion in large volume of the aquifer in the simulation time The simulated groundwater level and temperature distribution can be used as important data to develope an energy effective pumping and injection well system. Also it will be very useful to evaluate the hydraulic capacity of a target groundwater reservoir.

  • PDF

Desulfurization of Model Oil via Adsorption by Copper(II) Modified Bentonite

  • Yi, Dezhi;Huang, Huan;Li, Shi
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권3호
    • /
    • pp.777-782
    • /
    • 2013
  • In order to further reduce the sulfur content in liquid hydrocarbon fuels, a desulfurization process by adsorption for removing dimethyl sulfide (DMS) and propylmercaptan (PM) was investigated. Bentonite adsorbents modified by $CuCl_2$ for the desulfurization of model oil was investigated. The results indicated that the modified bentonite adsorbents were effective for adsorption of DMS and PM. The bentonite adsorbents were characterized by X-ray diffraction (XRD) and thermal analysis (TGA). The acidity was measured by FT-IR spectroscopy. Several factors that influence the desulfurization capability, including loading and calcination temperature, were studied. The maximum sulfur adsorption capacity was obtained at a Cu(II) loading of 15 wt %, and the optimum calcination temperature was $150^{\circ}C$. Spectral shifts of the ${\nu}$(C-S) and ${\nu}$(Cu-S) vibrations of the complex compound obtained by the reaction of $CuCl_2$ and DMS were measured with the Raman spectrum. On the basis of complex adsorption reaction and hybrid orbital theory, the adsorption on modified bentonite occurred via multilayer intermolecular forces and S-M (${\sigma}$) bonds.

포접화합물을 이용한 축냉시스템에 대한 이론적 해석 (Theoretical analysis on the cool storage system using clathrates)

  • 정재동;정인성;유호선;이준식
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.343-353
    • /
    • 1997
  • This paper presents a theoretical model for predicting transient behaviors during storage process of the cool storage system using the R141b clathrate. Introduction of the lumped capacitance method along with a brine reservoir having large thermal capacity yields a set of simplified energy equations. Based on the Arrhenius equation and the known experimental findings, the formation rate of clathrate for which the degree of subcooling is properly accounted is newly developed. An effective nondimensionalization of the model equations facilitates the closure of modeling as well as parametric study. Calculated results for a specific case not only simulate a typical pattern of temperautre variation in the tank successfully, but also agree reasonably well with available data. The effect of each characteristic parameter on the system performance is also investigated. It is revealed that the dominant among relevant parameters are the activation energy of reaction, the degree of subcoling and the initial mass fraction of refrigerant. Finally, the uncertainty associated with modeling of the shaft work variation appears to need further studies.

  • PDF

건물용 열병합발전 시스템의 적정규모 산정을 위한 최적 투자모형 (Optimal Sizing Evaluation Model of Building Cogeneration System)

  • 박종성;원선재;김정훈;박승호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.117-119
    • /
    • 1995
  • For an effective application of the cogeneration system for commercial and industrial buildings, we need to develop a relevant model to determine the long-term based optimal sizing of the cogeneration system considering electrical and thermal load demands, buy and sell contracts with electric utility and the annual production cost. In assessing the optimal sizing of cogeneration, we have to consider both economic parameters and their capacity expansion for the increased electrical and thermals demand in the future. In this paper, we propose a mathematical model for the optimal sizing of cogeneration systems considering annual production costs and other economic parameter such as, lifetime of the equipment, time value of the capital, etc. In the case study, we thoroughly examine the effects of the economic parameters and determine the optimal size of the sample system. In addition, we calculate the payback period of the cogeneration investment.

  • PDF

Structuring of Bulk Silicon Particles for Lithium-Ion Battery Applications

  • Bang, Byoung-Man;Kim, Hyun-Jung;Park, Soo-Jin
    • Journal of Electrochemical Science and Technology
    • /
    • 제2권3호
    • /
    • pp.157-162
    • /
    • 2011
  • We report a simple route for synthesizing multi-dimensional structured silicon anode materials from commercially available bulk silicon powders via metal-assisted chemical etching process. In the first step, silver catalyst was deposited onto the surface of bulk silicon via a galvanic displacement reaction. Next, the silver-decorated silicon particles were chemically etched in a mixture of hydrofluoric acid and hydrogen peroxide to make multi-dimensional silicon consisting of one-dimensional silicon nanowires and micro-scale silicon cores. As-synthesized silicon particles were coated with a carbon via thermal decomposition of acetylene gas. The carbon-coated multi-dimensional silicon anodes exhibited excellent electrochemical properties, including a high specific capacity (1800 mAh/g), a stable cycling retention (cycling retention of 89% after 20 cycles), and a high rate capability (71% at 3 C rate, compared to 0.1 C rate). This process is a simple and mass-productive (yield of 40-50%), thus opens up an effective route to make a high-performance silicon anode materials for lithiumion batteries.

선형열원 모델과 수정 DST(TRNVDSTP) 모델에 의한 지열 히트펌프 시스템 성능 예측 (Performance Prediction of Geothermal Heat Pump System by Line-Source and Modified DST(TRNVDSTP) Models)

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.61-69
    • /
    • 2012
  • Geothermal heat pump(GHP) systems have been shown to be an environmentally-friendly, efficient alternative to traditional cooling and heating systems in both residential and commercial applications. Although some experimental work related to performance evaluation of GHP systems with vertical borehole ground heat exchangers for commercial buildings has been done, relatively little has been reported on the performance simulation of these systems. The aim of this study is to evaluate the cooling and heating performance of the GHP system with 30 borehole ground heat exchangers applied to an commercial building($1,210m^2$) in Seoul. For this purpose, a typical design procedure was involved with a combination of design parameters such as building loads, heat pump capacity, circulating pump, borehole diameter, and ground effective thermal properties, etc. The cooling and heating performance prediction of the system was conducted with different prediction methods and then each result is compared.

플라이애시 사용 콘크리트의 품질에 미치는 미분시멘트의 영향 (The Effects of Fine Particle Cement on the Quality of Fly Ash Concrete)

  • 이정아;전규남;백대현;박종호;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.113-117
    • /
    • 2009
  • Fly ash (called FA hereafter) that results from thermal power plants is a long-term strength improving substance with reactivity to pozzolan and has been used for long. However, large amount of FA shows many advantages such as reduction of hydratio energy, long-term improvement in strength and economic feasibility and also has difficulties from reduction in initial strength and durability. In a preceding study, fine particle cement was applied to test the effects on initial strength. Therefore in this study, the effects of fine particle cement on the quality of FA concrete were reviewed. The results can be summarized as follows. Liquidity was increased by the most at FC substitution ratio of 15%. Air capacity was reduced according to increasing substitution ratio of FA and FC. Compressive strength showed high strength expression at all ages when FC was substituted at 45%. Synthesizing the above results, appropriate mixing of FC in FA concrete can improve liquidity, reduce unit quantity and show improvement in strength. In particular, mixed use of FC seems effective in improving early quality of concrete.

  • PDF

변압기용 절연유의 특성에 관한 실험적 연구 (A study on an experimental basis a special character of insulating oil the use of a transformers)

  • 김성대;박일수
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.5188-5193
    • /
    • 2011
  • 본 연구는 변압기 내부에 있는 절연유의 온도제어를 목적으로 열전소자인 펠티어 소자와 무전력 냉각장치인 Heat pipe를 이용한 다양한 시스템을 설계 제작하여, 절연유의 용량별 온도제어에 적용함으로써 최적의 시스템을 구현할 수 있었다. 실험을 통하여 $60^{\circ}C$ 이내의 상태에서는 Heat pipe 100 W + 펠티어 100 W의 조합형이 순수 Heat pipe 300 W보다 탁월한 성능을 확인할 수 있었다. 이를 통하여 조합형의 적정설계 방식이 우수하다는 것을 증명하고, 조합형을 사용함으로써 전기절약 효과와 수배전반의 보다 더 효율적인 관리에 기여하고자 한다.

하수슬러지 탄화물 흡착제를 이용한 혼합 악취(H$_2$S/CH$_3$SH)의 제거 (Removal of Mixed Odor(H$_2$S/CH$_3$SH) using Char Adsorbent Made from Sewage Sludge)

  • 한영석;최원준;김택준;김임경;오광중
    • 대한환경공학회지
    • /
    • 제30권11호
    • /
    • pp.1132-1138
    • /
    • 2008
  • 수슬러지의 열분해를 통해 생성된 char를 이용하여 황화수소(H$_2$S), 메틸머캡탄(CH$_3$SH) 복합악취를 제거하기 위한 흡착제를 제조하여 흡착특성을 살펴보았다. 고정층 반응기 실험에서 최적의 L/D ratio는 1.0이었으며, 온도의 증가에 따라 파과점과 흡착능이 증가되었다. H$_2$S와 CH$_3$SH의 동시흡착 특성은 단일흡착 실험보다 파과점에 도달하는 시간과 흡착량이 증가하였고, 동일 조건에서 CH$_3$SH이 H$_2$S보다 높은 유효확산계수 값을 가지므로 빠른 흡착속도로 인한 흡착능의 증가를 보였다. 또한 하수슬러지로부터 제조된 탄화물은 상업용 활성탄과 비교하여 H$_2$S 77%, CH$_3$SH 80%의 성능으로 혼합 악취성가스 제거가 가능할 것으로 판단된다.