• Title/Summary/Keyword: Effective measurement distance

Search Result 160, Processing Time 0.029 seconds

Image Based Text Matching Using Local Crowdedness and Hausdorff Distance (지역 밀집도 및 Hausdorff 거리를 이용한 영상기반 텍스트 매칭)

  • Son, Hwa-Jeong;Kim, Ji-Soo;Park, Mi-Seon;Yoo, Jae-Myeong;Kim, Soo-Hyung
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.10
    • /
    • pp.134-142
    • /
    • 2006
  • In this paper, we investigate a Hausdorff distance, which is used for the measurement of image similarity, to see whether it is also effective for document retrieval. The proposed method uses a local crowdedness and a Hausdorff distance to locate text images by determining whether a pair of images scanned at different time comes from the same text or not. To reduce the processing time, which is one of the disadvantages of a Hausdorff distance algorithm, we adopt a local crowdedness for feature point extraction. We apply the proposed method to 190 pairs of the same class and 190 pairs of the different class collected from postal envelop images. The results show that the modified Hausdorff distance proposed in this paper performed well in locating the tort region and calculating the degree of similarity between two images. An improvement of accuracy by 2.7% and 9.0% has been obtained, compared to a binary correlation method and the original Hausdorff distance method, respectively.

  • PDF

Estimation of the Substrate Size with Minimum Mutual Coupling of a Linear Microstrip Patch Antenna Array Positioned Along the H-Plane

  • Kwak, Eun-Hyuk;Yoon, Young-Min;Kim, Boo-Gyoun
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.320-324
    • /
    • 2015
  • Mutual coupling between antenna elements of a linear microstrip patch antenna array positioned along the H-plane including the effect of edge reflections is investigated. Simple formulas are presented for the estimation of the grounded dielectric substrate size with minimum mutual coupling. The substrate sizes calculated by these formulas are in good agreement with those obtained by the full-wave simulation and experimental measurement. The substrate size with minimum mutual coupling is a function of the effective dielectric constant for surface waves and the distance between the antenna centers. The substrate size with minimum mutual coupling decreases as the effective dielectric constant for surface waves on a finite grounded dielectric substrate increases.

Unsupervised Single Moving Object Detection Based on Coarse-to-Fine Segmentation

  • Zhu, Xiaozhou;Song, Xin;Chen, Xiaoqian;Lu, Huimin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.6
    • /
    • pp.2669-2688
    • /
    • 2016
  • An efficient and effective unsupervised single moving object detection framework is presented in this paper. Given the sparsely labelled trajectory points, we adopt a coarse-to-fine strategy to detect and segment the foreground from the background. The superpixel level coarse segmentation reduces the complexity of subsequent processing, and the pixel level refinement improves the segmentation accuracy. A distance measurement is devised in the coarse segmentation stage to measure the similarities between generated superpixels, which can then be used for clustering. Moreover, a Quadmap is introduced to facilitate the refinement in the fine segmentation stage. According to the experiments, our algorithm is effective and efficient, and favorable results can be achieved compared with state-of-the-art methods.

Effective Range Evaluation of Wireless Monitoring System for Monopile (모노파일용 원거리 무선 모니터링 시스템의 유효거리 평가)

  • Park, Kiwon;Lee, Jong-Sub;Choi, Changho;Byun, Yong-Hoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.6
    • /
    • pp.91-100
    • /
    • 2012
  • Wireless monitoring system for the structural health evaluation has a limit to the reliability of measured response. The objective of this study is to evaluate an effective measurement range of the wireless monitoring system on the analyzed data. For the wireless monitoring system, Bluetooth and Wi-Fi are applied to datalogger-receiver and receiver-personal computer, respectively. For the model of the monopile structure response, a laboratory-scale monopile is manufactured with Mono Cast Nylon and a lateral loading is applied by hammer impacting. Strain gauges attached on the model monopile are connected with the datalogger. The distances of datalogger-receiver and receiver-personal computer are changed for the evaluation of the measurement range. Experimental results show that the receiving rates of the response remain almost constant within limited distance, while the receiving rates dramatically decrease out of effective range. In addition, the receiving rates affect on the measured natural frequencies of the model monopile. This study suggests that the effective range evaluation of the wireless monitoring system may be used for the determination of a monitoring distance to the monopile installed in the offshore wind farm.

A Study on the Improvement of Measuring Methods in Land Suitability Assessment: Focused on the Distance Measurement and Threshold Definition (토지적성평가 평가방법 개선방안 연구 : 거리측정 및 임계치 설정방안을 중심으로)

  • Jeong, Yeun-Woo;Lee, Sang-Jun
    • Land and Housing Review
    • /
    • v.3 no.1
    • /
    • pp.69-78
    • /
    • 2012
  • This study proposes an approach to improve the accuracy of land assessment result focused on the Land Suitability Assessment. The detailed analysis processes are; (a) that they are analyzed considering resistance in distance measurement on the space characteristics of location, and; (b) that an assessment result is measured according to the threshold definition of membership function, which is applied in estimating conservation suitability. The assessment results are; firstly, the method considering resistance better reflects the local characteristics of area with worse accessibility including rivers and mountains than one by linear distance; secondly, the existing method that the maximum value of a target area is defined as the maximum threshold may draw a value evaluated lower than a threshold definition considering the distribution of measured indices. Finally, satellite images are overlapped with the assessed results, the applicability level from the approach proposed by this study is more coincident with the present status. The assessment method proposed by this study can be meaningful in view of that it improves the accuracy of Land Suitability Assessment. Furthermore, it can be applied as SDSS, which can support effective establishment of urban policies, in case of complementing the problems in executing the assessment system.

A Study on the Functional Efficiency according to Composition of Single Bedroom in Ward - Focused on Distance from NS to Bed - (종합병원 병동부 1인 병실 적용에 따른 기능효율성에 관한 연구 - 간호거점에서 병상간의 거리를 중심으로 -)

  • Kim, Khilchae;Lee, Hyunjin;Kwun, Joonbum
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.2
    • /
    • pp.17-24
    • /
    • 2015
  • Purpose: This study examines distance from nurse station to bed according to composition of single bedroom. Methods: This study has two groups of target sample ward planes. The first group has diverse patients bedroom. The other group is 36 single bedrooms and 2 3-bedrooms. The guideline of distance measurement was instituted for consistency. This study has 3 main concepts of the guideline. 1) The distance is shortcut from NS to bed. 2) The traffic line is center line between walls and center of door. 3) The start point is center of NS and the end point is bed. Results: The result of this study can be summarized into two points. The first one is that single bedroom has good privacy and longer distance from NS to bed. The second one is that weak point of single bedroom was asked ward operating system and architectural planning like as patients room, bed per unit, location of NS and plan type. Implications: Consideration Should be taken into account for the effective bedroom composition and allocation in ward. This Stuy hopefully serve as a stepping stone for the standard design of space program in ward planning.

A Study on Effective Range of Baseline Measurement Using Single Frequency (1 주파수에 의한 기선측정 유효범위에 관한 연구)

  • 김용일;박민호;김동현
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.12 no.2
    • /
    • pp.163-172
    • /
    • 1994
  • As for the baseline measurement using geodetic GPS receiver, this paper puts forth the effective measurement range of a low-priced GPS system receiving Ll frequency only. Compared with the data of baseline eliminated the ionospheric effects with L1/L2 frequencies, the results with Ll frequency approximate to those with dual frequency within the range of 15 km (the baseline discrepancy of the two methods is less than 2 cm). The results with Ll frequency are better within the range of 18 km. Based upon the analysis of data, we find that the convergence limit of integer ambiguity-applicable to double difference fixed solution- is about 18 km and the ionospheric effects have a great influence on the results when the baseline are longer than 20 km. This study also presents a standard which makes it possible to select the favorable data from the results of the GPS relative distance measurements.

  • PDF

A Study on the Effective Maintenance Method of the Stair Passage Leading Light installed In the Shopping Building (상가건물 계단통로유도등의 유지관리 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • This study was conducted by survey and inspection of stair passage leading lights in shopping buildings which are more than 5 stories and have an underground parking lot located at Pyeongtaek-si and Seongnam-si. Number of shopping building for this study is 30 and of stair passage leading light inspected by two lights in each shopping building is 60. The result of this study is that the type of installed leading lights is LED(77%), and 60% of leading lights has problem such as no cleaning, scratch and discoloration, etc. The height of installed leading lights meets the fire law which is less than 1m from the floor. Visible condition of leading lights is good except some leading lights which have a little visible problem due to banner advertisement. 37% of standby power has flickered and went out. 93% of total leading lights meets the fire law which is more than 1lux from 0.5m distance, but cold cathode fluorescent lamps(CCFLs) have the problem which not meets proper brightness level based on fire law. In additional measurement result, zero lux of leading lights is 32%(from 1m distance), 68%(from 1.5m distance) and 98%(from 2m distance). Leading light is very important facility because it is eyes and guide when emergency. Therefore, proper fire facility operating function inspection and total detailed inspection are important to keep the good condition of leading light except simple visual check, and also improvement in law system of type approval, fire construction inspection and illumination level will be needed.

Performance Evaluation of Gamma ray Shielding of Antimony Shielding Sheet (안티몬 차폐시트의 감마선 차폐 성능평가)

  • Han, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.135-140
    • /
    • 2018
  • In this study, the dose of antimony shielding sheet was measured and the shielding rates according to the distance between the radioisotopes and the detector was analyzed according to the type of $^{99m}Tc$, $^{18}F$, $^{201}Tl$, $^{131}I$, $^{123}I$ using the antimony shielding sheet. The detector was used with an inspector. Six sheets of 0.25 mmPb were prepared with 20 cm width and length. Measurement results using $^{99m}Tc$, $^{201}Tl$, and $^{123}I$ showed that as the thickness of the sheet became thicker, the farther the distance from the source to the sheet was, the smaller the transmitted dose amount was measured. It was analyzed that a thickness of 1.50 mm or more was required to obtain a shielding rates of 90% or more. In the experiments of $^{18}F$ and $^{131}I$, the dose value was highest when 0.25 mm sheet was used, and the shielding rates was negative, unlike the results of other radioisotopes. Since $^{201}Tl$ are used when using antimony sheet and $^{18}F$ and $^{131}I$ have no shielding effect, it is thought that it is effective to reduce dose by repeating training and simulation training so that work can be done in a short time.

The Effect of Pelvic Tilt Exercise with Changing the Body Position on Foot Contact Pattern in Hemiplegic Patients (자세에 따른 골반경사운동이 편마비 환자의 발 접촉양상에 미치는 효과)

  • Jang, Sang-Hun;Park, Soo-Jin;Kim, Min-Hee;Kim, Joong-Hwi;Kim, Jin-Sang
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.3
    • /
    • pp.445-453
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate the effect of pelvic tilt exercise with changing the body position on foot contact pattern in the hemiplegic patients. Methods : Thirty seven hemiplegic patients were randomly divided 3 groups; control group (CG), sitting exercise group (SIEG) and standing exercise group (STEG). F-mat system and F-scan system were used for the measurement of foot contact pattern of hemiplegic side in walking. Data were analyzed statistically using paired t-test and one-way ANOVA. Results : The results were as follows : 1) Contact area of CG and SIEG were not significant difference in walking. Contact area of STEG was significant increased in walking. 2) Anteroposterior distance of COP of SIEG and STEG were significant increased in walking. Conclusion : These results suggest that pelvic tilt exercise in sitting and standing position are effective in the improvement of Anteroposterior distance of COP and gait stability are increased in only standing position.