• 제목/요약/키워드: Effective ionization

검색결과 135건 처리시간 0.032초

Characterization of Yeast and Bacterial Type Strains with Food and Agricultural Applications by MALDI-TOF Mass Spectrometry Biotyping

  • Harnpicharnchai, Piyanun;Jaresitthikunchai, Janthima;Seesang, Mintra;Jindamorakot, Sasitorn;Tanapongpipat, Sutipa;Ingsriswang, Supawadee
    • 한국미생물·생명공학회지
    • /
    • 제48권2호
    • /
    • pp.138-147
    • /
    • 2020
  • Various microorganisms play important roles in food fermentation, food spoilage, and agriculture. In this study, the biotype of 54 yeast and bacterial strains having high potential for utilization in food and agriculture, including Candida spp., Lactobacillus spp., and Acetobacter spp., were characterized by matrix-assisted laser desorption/ionization time-of flight mass spectrometry (MALDI-TOF MS). This characterization using a fast and robust method provides much-needed information on the selected microorganisms and will facilitate effective usage of these strains in various applications. Importantly, the unique protein profile of each microbial species obtained from this study was used to create a database of fingerprints from these species. The database was validated using microbial strains of the same species by comparing the mass spectra with the created database through pattern matching. The created reference database provides crucial information and is useful for further utilization of a large number of valuable microorganisms relevant to food and agriculture.

The Barium Star HD204075: Iron Abundance and the Absence of Evidence for Accretion

  • Jeong, Yeuncheol;Yushchenko, Alexander;Gopka, Vira;Yushchenko, Volodymyr;Rittipruk, Pakakaew;Jeong, Kyung Sook;Demessinova, Aizat
    • Journal of Astronomy and Space Sciences
    • /
    • 제36권3호
    • /
    • pp.105-113
    • /
    • 2019
  • Spectroscopic observations of barium star ${\zeta}$ Capricornus (HD204075) obtained at the 8.2 m telescope of the European Southern Observatory, with a spectral resolving power R = 80,000 and signal to noise ratio greater than 300, were used to refine the atmospheric parameters. We found new values for effective temperature ($T_{eff}=5,300{\pm}50K$), surface gravity ($log\;g=1.82{\pm}0.15$), micro-turbulent velocity ($v_{micro}=2.52{\pm}0.10km/s$), and iron abundance ($log\;N(Fe)=7.32{\pm}0.06$). Previously published abundances of chemical elements in the atmosphere of HD204075 were analyzed and no correlations of these abundances with the second ionization potentials of these elements were found. This excludes the possible influence of accretion of hydrogen and helium atoms from the interstellar or circumstellar environment to the atmosphere of this star. The accretion of nuclear processed matter from the evolved binary companion was primary cause of the abundance anomalies. The young age of HD204075 allows an estimation of the time-scale for the creation of the abundance anomalies arising from accretion of interstellar hydrogen and helium as is the case of stars with low magnetic fields; which we estimate should exceed $10^8$ years.

Screening of Nitrosamine Impurities in Sartan Pharmaceuticals by GC-MS/MS

  • Chang, Shu-Han;Ho, Hui-Yu;Zang, Chi-Zong;Hsu, Ya-Hui;Lin, Mei-Chih;Tseng, Su-Hsiang;Wang, Der-Yuan
    • Mass Spectrometry Letters
    • /
    • 제12권2호
    • /
    • pp.31-40
    • /
    • 2021
  • Probable human carcinogenic compounds nitrosamines, have been detected as by-product impurities in sartan pharmaceuticals in recent years which has drawn worries for medication safety. To provide a sensitive and effective method for the quality control of sartan pharmaceuticals, this study established a feasible gas chromatography-tandem mass spectrometry (GC-MS/MS) method for simultaneous determination of 13 nitrosamines. The target analytes were separated on a DB-WAX Ultra Inert column (30 m × 0.25 mm; i.d., 0.25 ㎛) and were then subjected to electron impact ionization in multiple reaction monitoring mode. The established method was validated and further employed to analyze authentic samples. Limits of detection (LODs) and limits of quantification (LOQs) of the 13 nitrosamines were 15-250 ng/g and 50-250 ng/g, respectively, which also exhibited intra-day and inter-day accuracies of 91.4-104.8%, thereby satisfying validation criteria. Five nitrosamines, viz., N-nitrosodiethylamine, N-nitrosodimethylamine, N-nitrosodiphenylamine, N-nitrosomorpholine, and N-nitrosopiperidine were detected at concentrations above their LODs in 68 positive samples out of 594 authentic samples from seven sartans.

Acid-Catalyzed Hydrolysis of Hexacyanoferrate (III) to Prussian Blue via Sequential Mechanism

  • Youngjin Jeon
    • 대한화학회지
    • /
    • 제68권3호
    • /
    • pp.139-145
    • /
    • 2024
  • This study aims to elucidate the mechanism involved in the hydrolysis of the hexacyanoferrate(III) complex ion (Fe(CN)63-) and the mechanism leading to the formation of Prussian blue (FeIII4[FeII(CN)6]3·xH2O, PB) in acidic aqueous solutions at moderately elevated temperatures. Hydrolysis constitutes a crucial step in generating PB through the widely used single-source or precursor method. Recent PB syntheses predominantly rely on the single-source method, where hexacyanoferrate(II/III) is the exclusive reactant, as opposed to the co-precipitation method employing bare metal ions and hexacyanometalate ions. Despite the widespread adoption of the single-source method, mechanistic exploration remains largely unexplored and speculative. Utilizing UV-vis spectrophotometry, negative-ion mode liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS), and a devised reaction, this study identifies crucial intermediates, including aqueous Fe2+/3+ ions and hydrocyanic acid (HCN) in the solution. These two intermediates eventually combine to form thermodynamically stable PB. The findings presented in this research significantly contribute to understanding the fundamental mechanism underlying the acid-catalyzed hydrolysis of the hexacyanoferrate(III) complex ion and the subsequent formation of PB, as proposed in the sequential mechanism introduced herein. This finding might contribute to the cost-effective synthesis of PB by incorporating diverse metal ions and potassium cyanide.

NeQuick G의 TEC 예측 개선을 위한 지역 최적화 기법 연구 (Regional Optimization of NeQuick G Model for Improved TEC Estimation)

  • 이재령;선기영;최헌호;이지윤
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제13권1호
    • /
    • pp.63-73
    • /
    • 2024
  • NeQuick G is the ionosphere model utilized by Galileo single-frequency users to estimate the ionospheric delay on each user-satellite link. The model is characterized by the effective ionization level (Az) index, determined by a modified dip latitude (MODIP) and broadcast coefficients derived from daily global space weather observations. However, globally fitted Az coefficients may not accurately represent ionosphere within local area. This study introduces a method for regional ionospheric modeling that searches for locally optimized Az coefficients. This approach involves fitting TEC output from NeQuick G to TEC data collected from GNSS stations around Korea under various ionospheric conditions including different seasons and both low and high solar activity phases. The optimized Az coefficients enable calculation of the Az index at any position within a region of interest, accounting for the spatial variability of the Az index in a polynomial function of MODIP. The results reveal reduced TEC estimation errors, particularly during high solar activity, with a maximum reduction in the RMS error by 85.95%. This indicates that the proposed method for NeQuick G can effectively model various ionospheric conditions in local areas, offering potential applications in GNSS performance analyses for local areas by generating various ionospheric scenarios.

Determination of an Effective Wedge Angle by Combination of Two Arbitrary Universal Wedge Fields in Radiation Therapy of Cancer Patients with Megavoltage Photon Beams

  • Shamsi, Azin;Birgani, Mohammad Javad Tahmasebi;Behrooz, Mohammad Ali;Arvandi, Sholeh;Fatahiasl, Jafar;Maskny, Reza;Abdalvand, Neda
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권1호
    • /
    • pp.197-200
    • /
    • 2016
  • Background: Wedge filters are commonly used in radiation oncology for eliminating hot spots and creating a uniform dose distribution in optimizing isodose curves in the target volume for clinical aspects. These are some limited standard physical wedges ($15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$),or creating an arbitrary wedge angle, like motorized wedge or dynamic wedge,${\ldots}$ The new formulation is presented by the combination of wedge fields for determining an arbitrary effective wedge angles. The isodose curves also are derived for these wedges. Materials and Methods: we performed the dosimetry of Varian Clinac 2100C/D with Scanditronix Wellhofer water blue phantom, CU500E, OmniPro - Accept software and 0.13cc ionization chamber for 6Mv photon beam in depth of 10cm (reference depth) for universal physical wedges ($15^{\circ}$, $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$) and reference field $10.10cm^2$. By combining the isodose curve standard wedge fields with compatible weighting dose for each field, the effective isodose curve is calculated for any wedge angle. Results: The relation between a given effective wedge angle and the weighting of each combining wedge fields was derived. A good agreement was found between the measured and calculated wedge angles and the maximum deviation did not exceed $3^{\circ}$. The difference between the measured and calculated data decreased when the combined wedge angles were closer. The results are in agreement with the motorized single wedge appliance in the literature. Conclusions: This technique showed that the effective wedge angle that is obtained from this method is adequate for clinical applications and the motorized wedge formalism is a special case of this consideration.

PEMOCVD of Ti(C,N) Thin Films on D2 Steel and Si(100) Substrates at Low Growth Temperatures

  • Kim, Myung-Chan;Heo, Cheol-Ho;Boo, Jin-Hyo;Cho,Yong-Ki;Han, Jeon-Geon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.211-211
    • /
    • 1999
  • Titanium nitride (TiN) thin films have useful properties including high hardness, good electrical conductivity, high melting point, and chemical inertness. The applications have included wear-resistant hard coatings on machine tools and bearings, decorative coating making use of the golden color, thermal control coatings for widows, and erosion resistant coatings for spacecraft plasma probes. For all these applications as feature sizes shrink and aspect ratios grow, the issue of good step coverage becomes increasingly important. It is therefore essential to manufacture conformal coatings of TiN. The growth of TiN thin films by chemical vapor deposition (CVD) is of great interest for achieving conformal deposition. The most widely used precursor for TiN is TiCl4 and NH3. However, chlorine impurity in the as-grown films and relatively high deposition temperature (>$600^{\circ}C$) are considered major drawbacks from actual device fabrication. To overcome these problems, recently, MOCVD processes including plasma assisted have been suggested. In this study, therefore, we have doposited Ti(C, N) thin films on Si(100) and D2 steel substrates in the temperature range of 150-30$0^{\circ}C$ using tetrakis diethylamido titanium (TDEAT) and titanium isopropoxide (TIP) by pulsed DC plamsa enhanced metal-organic chemical vapor deposition (PEMOCVD) method. Polycrystalline Ti(C, N) thin films were successfully grown on either D2 steel or Si(100) surfaces at temperature as low as 15$0^{\circ}C$. Compositions of the as-grown films were determined with XPS and RBS. From XPS analysis, thin films of Ti(C, N) with low oxygen concentration were obtained. RBS data were also confirmed the changes of stoichiometry and microhardness of our films. Radical formation and ionization behaviors in plasma are analyzed by optical emission spectroscopy (OES) at various pulsed bias and gases conditions. H2 and He+H2 gases are used as carrier gases to compare plasma parameter and the effect of N2 and NH3 gases as reactive gas is also evaluated in reduction of C content of the films. In this study, we fond that He and H2 mixture gas is very effective in enhancing ionization of radicals, especially N resulting is high hardness. The higher hardness of film is obtained to be ca. 1700 HK 0.01 but it depends on gas species and bias voltage. The proper process is evident for H and N2 gas atmosphere and bias voltage of 600V. However, NH3 gas highly reduces formation of CN radical, thereby decreasing C content of Ti(C, N) thin films in a great deal. Compared to PVD TiN films, the Ti(C, N) film grown by PEMOCVD has very good conformability; the step coverage exceeds 85% with an aspect ratio of more than 3.

  • PDF

임상검체에서 분리된 Ochrobactrum anthropi의 효과적인 동정 (Effective Identification of Ochrobactrum anthropi Isolated from Clinical Specimens)

  • 고현미;조준현;백해경
    • 대한임상검사과학회지
    • /
    • 제52권3호
    • /
    • pp.221-228
    • /
    • 2020
  • Ochrobactrum anthropi는 oxidase를 생산하는 비발효산소성 그람음성 막대균으로 외관이 비슷하고 oxidase가 양성인 비발효 세균과 혼합배양 시 구분이 힘들고 생화학적 동정 장비로는 정확한 동정에 한계가 있다. 따라서 본 연구에서는 생화학적 검사 방법으로 동정이 힘든 세균동정의 Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry Platform (MALDI-TOF) 법의 유용성을 제시하고자 하였다. MicroScan을 이용해 검사했던 O. anthropi 5례를 분석한 결과, 최종보고까지 6.2일이 소요되었으며 E. coli의 3.0일에 비해 3.5일이 더 소요되었다. 5번 환자 고름 검체는 Achromobater xylosoxidans와 혼합감염으로 여러 번의 계대 배양과 재검사로 인해 11.3일이 소요되었는데, MALDI-TOF법으로 검사한 경우 한 번에 동정되었다. 4명의 환자는 기저질환이 있는 60세 이상이었고 기회감염과 원내감염의 가능성을 배제할 수 없었으며, 그 중 92일 만에 채취된 검체는 imipenem과 meropenem에 내성이었다. 따라서 O. anthropi처럼 동정이 까다로운 세균은 신속하고 적절한 환자 치료를 위해 MALDI-TOF법을 이용한 검사가 매우 유용할 것으로 사료된다.

동위원소 희석 HPLC/MS에 의한 혈청 내 urea의 정량 (Quantification of urea in serum by isotope dilution HPLC/MS)

  • 이화심;박상열
    • 분석과학
    • /
    • 제18권4호
    • /
    • pp.271-277
    • /
    • 2005
  • 혈액 내 urea는 임상진단 시 신장 기능을 판단하는 중요한 표지물질로서 측정되고 있다. 단백질 등 질소화합물의 최종 대사물인 urea는 콩팥의 사구체에서 걸러져 소변으로 배출되는데, 사구체의 거르는 능력이 저하되면 결국 혈액 속의 urea 농도가 증가하게 되어 신장 기능의 정상여부를 판단할 수 있게 된다. 이러한 임상진단 결과의 신뢰성 향상을 위해서는 측정결과가 일차분석법으로 인증된 인증표준 물질과 소급성 고리를 유지해야 한다. 본 연구에서는 혈청 내 urea의 일차분석법으로서 $15^N_2$-urea를 내부 표준물질로 사용하는 동위원소희석 액체크로마토그라피-질량분석법 (ID-HPLC/MS)을 개발하였다. 이 방법은 측정원리상 고도의 정확성이 확보될 뿐 아니라 별도의 유도체화가 필요 없기 때문에 빠르고 편리하다. $C_{18}$-분리관에 0.1 mmol/L $NH_4Cl$ buffer를 이동상으로 사용하여 urea를 분리하였는데, 이 완충용액은 비교적 분자량이 작은 urea를 질량분석하는데 방해가 크지 않은 장점이 있다. HPLC와 질량분석기의 인터페이스로서 positive mode의 electrospray ionization (ESI)를 사용하여 높은 감도와 재현성을 성취하였다. 국제적으로 인정된 인증표준물질의 분석을 통해 최적화된 방법의 유효성을 확인하였으며, 국제비교시험에도 참여하여 좋은 결과를 얻었다. ISO guide에 따라 불확도를 계산하였으며, 확장 불확도는 95% 신뢰도에서 약 1.8%로 나타났다. 이 분석법은 표준연에서 개발 중인 혈청인증표준물질을 인증하는 일차기준측정절차로도 사용되고 있다.

동위원소희석 액체크로마토그래피-질량분석법을 이용한 육류 중 클로람페니콜의 정밀한 정량 분석에 관한 연구 (Accurate determination of chloramphenicol in meat by isotope dilution liquid chromatography mass spectrometry (ID-LC/MS))

  • 송혜민;김병주;정혁;안성희
    • 분석과학
    • /
    • 제23권6호
    • /
    • pp.524-530
    • /
    • 2010
  • 클로람페니콜은 미생물과 박테리아들의 활동을 억제시킴으로써 동물 치료에 효과적인 축산 항생제 중의 하나이다. 그러나 사람에게 재생 불량성 빈혈과 같은 치명적인 부작용이 발생하여 식용으로 사육하는 동물들에 대한 클로람페니콜의 사용을 유럽을 포함한 많은 나라에서 금지하였다. 본 연구에서는 돼지고기 시료 중 클로람페니콜을 분석하기 위하여 동위원소희석 액체크로마토그래피-질량분석법(IDLC/MS/MS)을 이용하여 정확하고 정밀한 정량분석을 하였다. 돼지고기 시료중의 클로람페니콜은 에틸아세테이트로 추출하였으며, 회수율을 높이기 위하여 고체상 추출법(Solid Phase Extraction)을 이용하였다. 액체크로마토그래피/질량분석기는 전기 분무 이온화 장치(Electrospray Ionization, ESI)를 장착하여 음이 온 모드로 선택반응분석법(Selected Reaction Monitoring mode)에서 수행하였다. 클로람페니콜의 분자이온 $[M-H]^-$이온이 조각이온인 $[M-H-(HCOCl)]^-$로 가는 m/z 321 ${\rightarrow}$ 257와 동위원소의 m/z 326 ${\rightarrow}$ 262 채널을 선택하여 분석하였다. 클로람페니콜을 약 0.2, 1, 10, $25\;{\mu}g$/kg의 농도가 되도록 첨가한 돼지고기 시료로부터 제조값과 측정 분석값을 비교하여 검토한 결과, 측정값들은 불확도 범위 내에서 제조값과 일치함을 보였다. 또한 IRMM(Institute for Reference Materials and Measurement)의 클로람페니콜 분석용 돼지고기 시료인 인증 표준물질 BCR 445를 분석한 결과, 본 실험의 측정값은 불확도 범위 내에서 인증값과 일치함을 보였으며 불확도의 경우에는 IRMM이 제공한 값보다 훨씬 향상된 값을 보였다.