• Title/Summary/Keyword: Effective frequency

Search Result 4,778, Processing Time 0.04 seconds

An Analysis of the Frequency-Dependent Resultant Ground Impedance of Vertical Ground Electrodes Installed in Parallel (병렬로 시공된 수직 접지전극의 합성접지임피던스의 주파수의존성 분석)

  • Lee, Bok-Hee;Cho, Sung-Chul;Seong, Chang-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • This paper deals with the experimental results of the frequency-dependent resultant ground impedance of vertical ground electrodes installed with a regular n-polygon. In order to propose an effective method of installing the vertically-driven multiple ground electrodes used to obtain the low ground impedance, the resultant ground impedance of ground electrodes installed with a regular n-polygon were measured as functions of the number of ground electrodes and the frequency of test currents and the results were discussed based on the potential interferences among ground electrodes. As a consequence, the effect of potential interference on the resultant ground impedance of vertical ground electrodes is frequency-dependent and it is significant in the low frequency of a few hundreds [Hz]. The resultant ground impedance of multiple vertical ground electrodes is not decreased in linearly proportion to the number of ground electrodes due to the overlapped potential interferences. Also the distributed-parameter circuit model considering the potential interference, the frequency-dependent relative permittivity and resistivity of soil was proposed. The simulated results of the frequency-dependent resultant ground impedance of multiple vertical ground electrodes are in good agreement with the measured data.

Effect of Rainfall Design Frequency Determination on the Design of Storm Sewer System (강우 확률년수의 설정이 우수관거 설계에 미치는 영향)

  • Lee, Cheol-kyu;Hyun, In-hwan;Dockko, Seok;Kim, Hyung-jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.647-654
    • /
    • 2005
  • Recently, the economic losses caused by inundation are increasing due to the urbanization and industrialization, i.e., intensive land utilization and concentration of population and properties. It is regarded that the role of the storm sewer systems in urban areas becomes more important as one of the effective countermeasures for reducing the inundation losses. In this study, the effects of rainfall design frequency enhancement on the construction cost of the storm sewer systems were analyzed by increasing the design frequency from the present design frequency of the sewer systems, which is 5~10 years, to 15 years, 20 years and 30 years. The change rate functions of the design discharge and construction cost based on the various design frequencies were derived by regression analysis. According to the analysis, change the rate of design discharge at 15, 20, 30 years rainfall design frequencies were increased by 10%, 17.1%, and 27.2%, respectively, when compared to that at 10 year frequency. Furthermore, it was found that by increasing the design frequency from 10 years to 15 years, 20 years and 30 years, the construction costs were increased by 5.0%, 8.0% and 12.4%, respectively. Finally, their reliabilities need to be tested by applying the rate functions to the real storm sewer districts.

A Study on the Characteristics of New Frequency Controller According to Changing the Frequency Measurement Position of HVDC System (HVDC 시스템의 주파수 신호검출 위치 변경에 따른 새로운 주파수 제어기 특성 연구)

  • Kim Chan-Ki;Han Byoung-Sung;Park Jong-Kwang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.457-467
    • /
    • 2005
  • This paper deals with the new frequency controller of the HVDC scheme linking Haenam to Cheju Island. The primary aim of the study is to develop and evaluate a new frequency controller after the removing of the present synchronous compensators. The simulation methods are the mix of PSCAD/EMTDC and PSS/E, the main system studies are done for the transient state analysis using PSCAD/EMTDC. The study cases are completed involving 3 phase, single phase trip and load tripping events and study plots presented. In conclusion, the new frequency measurement from the AC network gives effective frequency control and dynamic performance.

Analysis method for the Measured Track Geometry Data using Wavelet Transform (웨이브렛 변환을 이용한 궤도틀림 분석)

  • Lee, In-Kyu;Kim, Sung-Il;Yeo, In-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.2 s.33
    • /
    • pp.187-192
    • /
    • 2006
  • The regularity of railway track alignment is a crucial component fur maintaining travel safety and the smoothness of passenger ride. The conventional spectral analysis has been considered to estimate the severity of the track irregularity from measured data. The time domain data used to be changed into the frequency domain by Fourier transform. Because the measuring points can be regarded as the time points, the spatial-frequency can be introduced instead of the time-frequency. Although FFT(Fast Fourier Transform) and/or PSD(Power Spectral Density) function could provide fairly localized information within frequency domain, but chronical configurations of data could be missed. In this study, we attempt to apply the Morlet wavelet transform for the purpose of a frequency-time-domain analysis rather than a frequency-domain analysis. The applicability of wavelet transform is examined for the estimation of the track irregularity with real measured track data on the section of Kyoung-bu line by EM-120 measuring vehicle. It is shown that the wavelet transform can be an effective tool to manage the track irregularity.

Robust fine carrier offset estimation for OFDM in Doppler conditions (도플러 환경에 강인한 OFDM 반송파 미세 주파수 동기)

  • Kang, Eun-Su;Han, Dong-Seog
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.5
    • /
    • pp.109-114
    • /
    • 2009
  • An orthogonal frequency division multiplexing(OFDM) system is effective to bandwidth because of orthogonality of subcarriers and robust to multipath fading. However, if there is a frequency offset, we lose the orthogonality of subcarriers and that results in inter-carrier interference(ICI) which increases errors in the system. In this paper, we propose an algorithm that estimates the fine frequency offset using a correlation method in OFDM systems. This scheme compares two correlation values in different frequency offsets with opposite directions. From the difference between two correlation values we can derive a fine frequency offset estimation algorithm. Its performance is verified by computer simulations.

The Effect of Sling Exercise Therapy with Vibration Balls on Upper Limb Muscle Activity for Paraplegia-Spinal Cord Injury

  • Oh, Ju Hwan;Kwon, Tae Kyu
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.3
    • /
    • pp.187-191
    • /
    • 2018
  • Objective: The purpose of the present study is to investigate the effect of a muscle activity by applying the complex exercise method of sling in accordance with the provision of various vibration intensities for paraplegia-spinal cord injury. Method: The subjects of the study were 15 men in their 40s and 50s with lower limb disabilities and low potential risk, who were randomly divided into a sling exercise group (SG n=4), a sling with low frequency vibration group (SLVG n=4), a sling with mid-frequency vibration group (SMVG n=4), and a sling with high frequency group (SHVG n=4) in accordance with the provision of slings and vibration stimuli. The vibratory intensity provided was divided into low frequency (30 Hz), mid-frequency (50 Hz), and high frequency (70 Hz). The anterior deltoid (AD), the posterior deltoid (PD), the pectoralis major (PM), the upper trapezius (UT), the latissimus dorsi (LD), and the multifidus (MF) were measured to compare and analyze muscle activity. Results: The closed kinetic chain (CKC) exercise to the shoulder joint showed higher muscle activity in most muscles for the SMVG, and statistically significant differences in the anterior deltoid (AD), the pectoralis major (PM), and the multifidus (MF) in particular. Conclusion: The intermediate frequency (50 Hz) string vibration was the effective vibration stimuli for Closed kinetic chain (CKC) exercises.

Relationship among Sexual Knowledge, Frequency, Satisfaction, Marital Intimacy and Levels of Depression in Stroke Survivors and Their Spouses (뇌졸중으로 인한 편마비 중년 남성과 배우자의 성지식, 성행동, 성만족, 부부친밀감, 우울감의 관계)

  • Kim, Jung-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.38 no.3
    • /
    • pp.483-491
    • /
    • 2008
  • Purpose: The purpose of this research was to examine the relationship between sexual knowledge, frequency, satisfaction, marital intimacy, and depression levels in stroke survivors and their spouses. Methods: This study was a convenience sample of Korean men who had experienced a stroke and their spouses. The subjects were discharged from the hospital and received physical therapy. Data such as sexual knowledge, frequency, satisfaction, marital intimacy, and depression levels were collected from November 2005 to April 2006. Results: In a comparison of stroke survivors and their spouses, the survivors showed higher mean levels of sexual knowledge and marital intimacy. The levels of knowledge, frequency, satisfaction and marital intimacy were low and depression was mild in the subjects. There were significant correlations between sexual frequency, sexual satisfaction and marital intimacy. Also, subjects with lower levels of sexual satisfaction were more depressed. The spouses who possessed greater levels of sexual knowledge reported a higher frequency of sex and greater marital intimacy. In addition, spouses who reported feeling greater levels of marital intimacy experienced fewer depressive symptoms. Conclusion: These findings demonstrate a need for the development of sexual adaptation programs which could be effective in improving sexual knowledge, frequency, satisfaction, marital intimacy, and depression reported by stroke patients and their spouses. Ideally, these corrective programs should be administered before patients are discharged from the hospital.

Frequency Characteristics of Acoustic Emission Signal from Fatigue Crack Propagation in 5083 Aluminum by Joint Time-Frequency Analysis Method (시간-주파수 해석법에 의한 5083 알루미늄의 피로균열 진전에 의할 음향방출 신호의 주파수특성)

  • NAM KI-WOO;LEE KUN-CHAN
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.3 s.52
    • /
    • pp.46-51
    • /
    • 2003
  • Acoustic emission (AE) signals, emanated during local failure of aluminum alloys, have been the subject of numerous investigations. It is well known that the characteristics of AE are strongly influenced by the previous thermal and mechanical treatment of the sample. Possible sources of AE during deformation have been suggested as the avalanche motion of dislocations, fracture of brittle particles, and debonding of these particles from the alloy matrix. The goal of the present study is to determine if AE occurring as the result of fatigue crack propagation could be evaluated by the joint time-frequency analysis method, short time Fourier transform (STFT), and Wigner-Ville distribution (WVD). The time-frequency analysis methods can be used to analyze non-stationary AE more effectively than conventional techniques. STFT is more effective than WVD in analyzing AE signals. Noise and frequency characteristics of crack openings and closures could be separated using STFT. The influence of various fatigue parameters on the frequency characteristics of AE signals was investigated.

Design and Fabrication of High Frequency Ground Impedance Measuring System for Assessment of Grounding System for Lightning Protection (낙뢰 보호용 접지시스템 평가를 위한 고주파 접지임피던스 측정시스템의 설계 및 제작)

  • Gil, Hyoung-Jun;Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min;Kim, Young-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.47-52
    • /
    • 2016
  • This paper describes the design and fabrication of high frequency ground impedance measuring system for assessment of grounding system for Lightning protection. The ground impedance measuring system has been designed and fabricated which makes it possible to assess the ground impedance by frequency ranges from 100 Hz to 1 MHz. The effective grounding systems having a very low impedance to electromagnetic disturbance such as lightning surges and noises in microelectronics and high-technology branches are strongly required. In order to analyze the dynamic characteristic of grounding system impedances in lightning and surge protection grounding systems, it is highly desirable to assess the ground impedances as a measure of performance of grounding system in which lightning and switching surge currents with fast rise time and high frequency flow. The measuring system is based on the variable frequency power supply and consists of signal circuit part, main control part, data acquisition and processing unit, and voltage and current probe system. The ground impedance measuring system can be used to assess grounding system during occurrence of lightning.

Open-Loop Control of Combustion Instability in Hot-Firing Test Using Gaseous Hydrocarbon Fuel (기체 탄화수소 연료 연소시험에서 연소불안정의 개루프 제어)

  • Hwang, Donghyun;Ahn, Kyubok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.28-36
    • /
    • 2018
  • A study was conducted to apply open-loop control to the combustion instability in a dump combustor using gaseous hydrocarbon fuels. Control power and frequency were varied by employing a loudspeaker under combustion conditions with similar characteristic chemistry times of the fuels. In the case of open-loop control where the frequency was identical to the combustion instability frequency, the open-loop control power affected the control performance. Results obtained from conducted open-loop control tests, where the frequency was different from the combustion instability frequency, show that setting the open-loop control frequency similar to the combustion instability frequency is effective.