• Title/Summary/Keyword: Effective discharge energy

Search Result 130, Processing Time 0.032 seconds

Economic Analysis of Dam Operation Improvement by Dam Downstream River Improvement Works (II)-Economic Benefit and Cost Allocation Analysis (댐하류하천정비사업의 댐 운영개선 효과 경제성 분석 (II) -경제적 편익 및 비용분담률 분석)

  • Yoo, Seung-Hoon;Lee, Gwang-Man;Lee, Eul-Rae
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.9
    • /
    • pp.765-776
    • /
    • 2011
  • Flood discharge capacity in a dam downstream reach has been decreased after dam construction because of the river cross section reduction impacted by farm lands, sand-bars and parking lots, etc. in river flood plains. Those obstacles being in the river inside areas have caused negative influences to the dam operation policy. Therefore, the dam downstream river improvement work associated with the dam operation improvement plan is under construction for removing reduction factors on the dam effective storage, assuring flood safety in the dam downstream river and incrementing dam operation benefits. But the project has issued some problems such as project feasibility, economic evaluation, cost allocation and benefit share, etc. Since a dam enterpriser has not committed such kind of project before, it is necessary to set up an objective analysis process and a quantitative financial valuation. This study examines the measurable economic benefits and the cost allocation of the project for the fairness between benefit owners (central government and water electricity enterprisers). As a result, the total economic benefit from 3 dams (Imha, Daechung and Youngdam Dam) accounts for 14.41 Billion Won/year. The financial valuation of K-water as a project enterpriser is approximately estimated at 40% of the total value and the government is 60%.

Contribution of Non-Point Pollution to Water Quality and Runoff Characteristics from Agricultural Area of the Upstream Watersheds of Lake Chinyang

  • Lee, Chun-Sik;Jang, Seong-Ho
    • Journal of Environmental Science International
    • /
    • v.22 no.3
    • /
    • pp.259-267
    • /
    • 2013
  • In this study, non-point source(NPS) contribution was investigated based on flow rates and water qualities of streams into the lake during rainfall events. Event mean concentration(EMC) and the pollution loads were calculated to establish a database for NPS control measurement in the survey area, and so on. The runoff characteristics of NPS were investigated and estimated on the basis of the ratio of an agricultural to forest area in the stream of sub-catch basin during rainfall events. Non-point source pollution loads were also calculated to establish a database for NPS control measure in the upstream lake Chinyang. At a rainfall event, BOD concentrations rise sharply at the early peak time of runoff, however, peaks of TSS concentration were observed at the similar time of peak flow. This was a phenomenon shown at the watersheds caused by forest and geological types. The discharged EMC range was 2.9-4.8 mg/L in terms of BOD. The discharged EMC range was 6.2-8.2 mg/L in terms of SS. The discharged EMCs of T-N and T-P were 1.4-2.5 mg/L and 0.059-0.233 mg/L, respectively. Total BOD loading rate through the 3 tributaries to the lake Chinyang was 1,136 kg/d during dry weather. The upper watershed area of the Nam-river dam in this study was divided into 14 catchment basins based on the Korean guideline for total maximum daily load(TMDL) of water quality pollutants. The higher the agricultural land-use ratio, the more NPS loading rate discharged, but the more occupied a forest area, the lower more NPS loading rate discharged. In an agricultural land-use area more than 20%, the increase of NPS loadings might be dramatically diffused by increasing the integrated complex-use like vinyl-house facilities and fertilizer use etc. according to the effective land-use utilization. The NPS loading rates were BOD 0.3 $kg/ha{\cdot}day$, SS 0.21 $kg/ha{\cdot}day$, TN 0.02 $kg/ha{\cdot}day$, TP 0.005 $kg/ha{\cdot}day$ under less than 10% agricultural land-use. In agricultural land-use of 20%-50%, these values were investigated in the range of 0.32 $kg/ha{\cdot}day$-0.73 $kg/ha{\cdot}day$ for BOD, 0.92 $kg/ha{\cdot}day$-3.32 $kg/ha{\cdot}day$ for SS, 0.70 $kg/ha{\cdot}day$-0.90 $kg/ha{\cdot}day$ TN, 0.03 $kg/ha{\cdot}day$-0.044 $kg/ha{\cdot}day$ for TP.

Performance of Carbon Cathode and Anode Electrodes Functionalized by N and O Doping Treatments for Charge-discharge of Vanadium Redox Flow Battery (탄소전극의 질소 및 산소 도핑에 따른 바나듐 레독스-흐름전지 양극 및 음극에서의 촉매화학적 특성 연구)

  • Lim, Hyebin;Kim, Jiyeon;Yi, Jung S.;Lee, Doohwan
    • Clean Technology
    • /
    • v.23 no.3
    • /
    • pp.308-313
    • /
    • 2017
  • In this study, we investigated the electrocatalytic effects of the N and O co-doping of Graphite Felt (GF) electrode for the vanadium redox flow battery (VRFB) at the cathode and the anode reaction, respectively. The electrodes were prepared by chemical vapor deposition (CVD) with $NH_3-O_2$ at 773 K, and its effects were compared with an electrode prepared by an O doping treatment. The surface morphology and chemical composition of the electrodes were characterized by scanning electron microscopy (SEM) and photoelectron spectroscopy (XPS). The electrocatalytic properties of these electrodes were characterized in a VRFB single cell comparing the efficiencies and performance of the electrodes at the cathode, anode, and single cell level. The results exhibited about 2% higher voltage and energy efficiencies on the N-O-GF than the O-GF electrode. It was found that the N and O co-doping was particularly effective in the enhancement of the reduction-oxidation reaction at the anode.

Development of State of Charge and Life Cycle Evaluation Algorithm for Secondary Battery (이차전지의 상태 감시 및 수명 예측 알고리즘 개발)

  • Park, Jaebeom;Kim, Byeonggi;Song, Seokhwan;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.369-377
    • /
    • 2013
  • This paper deals with the state of charge(SOC) and life cycle evaluation algorithm for lead-acid battery, which is essential factor of the electric vehicle(EV) and the stabilization of renewable energy in the smart grid. In order to perform the effective operation of the lead-acid battery, SOC and life cycle evaluation algorithm is required. Specific gravity with the change of electrolyte temperature inside battery case should be obtained to evaluate the SOC of lead-acid battery, however it is difficult to measure the electrolyte temperature of sealed type lead-acid battery. To overcome this problem, this paper proposes the equation of thermal transmission to compensate internal temperature of the lead-acid battery. Also, it is difficult to exactly evaluate the life cycle of battery, depending on the operation conditions of lead-acid battery such as charging and discharging state, self discharging rate and environmental issue. In order to solve the problem, this paper presents the concept for gravity accumulation of charge and discharge cycle, which is the value converted at $20^{\circ}C$. By using the proposed algorithm, this paper propose the test device based on the Labview software. The simulation results show that it is a practical tool for the maintenance of lead-acid battery in the field of industry.

Comparison of meridians electric response property for laser and acupuncture stimulation (레이저자극과 수기자극에 대한 경락전기반응 특성비교)

  • Lee, Yong-Heum;Ryu, Yeon-Hang;Jung, Byoung-Jo;Shin, Tae-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.12
    • /
    • pp.2335-2342
    • /
    • 2007
  • Laser stimulation has been widely studied and used in clinic. However, electrical response by laser stimulation on meridians has not been investigated. In this study, we compared electric potential of laser and acupuncture stimulation on meridians. We measured electric potential variation at acupoints(Samgan(LI3) and Hapgok(LI4)) on Large Intestine Meridian. In laser stimulation results, average peak electric potential is very low($7.53{\pm}3.44{\mu}V$) for before and after stimulation. However, acupuncture stimulation was performed in ground connection condition and resulted in huge variation of average peak electric potential($2.65{\pm}1.53mV$). That is, the intensity and pattern of electric potential were dependent on the ground connection condition and individual. Also, the electric potential pattern was very similar to the pattern of electric charge and discharge of capacitor. The acupuncture stimulation using a insulating needle resulted in lower average peak electric potential variation($0.25{\pm}0.16mV$) than that of acupuncture stimulation. It might present little electrical response of acupuncture stimulation using insulating needles. In point of electrical response, the laser stimulation was determined to be no acupuncture effect at meridian. Acupuncture stimulation seems to be most effective method to induce electrical response at meridians. The procedure and effect of acupuncture might be considered as energy consensus phenomenon by transportation of bio-ion charge between a practitioner and patient.

Threshold Condition for Exclusion of Riprap into Bypass Pipe (저층수 배출관에 유입된 사석의 배제 한계조건)

  • Jeong, Seokil;Lee, Seung Oh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.1
    • /
    • pp.57-66
    • /
    • 2019
  • One of the most serious problems with concrete small dams or barriers installed in small/median rivers is the deposit of sediments, especially, in Korea. An effective way to discharge such sediments to downstream is to construct a bypass pipe under the river bed. However, efficiency may become lowered if ripraps are entered into the bypass pipe. Therefore, in this study, we derived the threshold condition for the exclusion of ripraps from the bypass pipe using 3D numerical analysis. Upstream flow of the small dam was assumed to be stationary, and the energy concept was applied to the control volume containing the bypass pipe and its periphery. As a result, when the ratio of the water level difference between upstream and downstream to the diameter of the riprap was approximately equal to 1.2, the threshold condition for exclusion of the stones or riprap from the bypass pipe was affirmatively determined. If the characteristics of the adsorptive sediment adversely affecting the river environment in the future would be taken into account, results from this study are expected to put to practical use in the management of concrete small dam with bypass pipe system.

Three Cases of Menopausal Hot Flush and Sweating Treated by Ascending Kidney Water and Descending Heart Fire (AKDH) Pharmacopuncture Treatment (약침을 이용한 수화조절법으로 호전된 갱년기 상열감 및 발한과다 환자 치험 3례)

  • Jo, Na-Young;Roh, Jeong-Du
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.28 no.2
    • /
    • pp.193-203
    • /
    • 2015
  • Objectives : The purpose of this study is to evaluate the clinical effects of ascending kidney water and descending heart fire pharmacopuncture treatment for hot flush and sweating. Methods : Ascending kidney water and descending heart fire pharmacopuncture is achieved by injecting pharmacopuncture on a specific acupoint to change from the state of water-fire disharmony to harmonious state. Hwangryunhaedok-tang (黃連解毒湯) pharmacopuncture is injected on both side Gyeonjeong (GB 21 ), Pungji (GB 20 ). Total 0.4 cc was injected by 0.1 cc each point. BUM (Bear’s gall bladder, ox bezoar and musk) pharmacopuncture is injected on both side Jeonjung (CV 17 ), Jungwan (CV 12 ), Gihae (CV 6 ). Total 0.15 cc was injected by 0.05 cc each point. Treatment was done daily. The method of evaluation are Hot Flush Score (HFS), VAS and sweating areas. Results : In case 1, after treatment hot flush score was reduced from 24 to 4 points. VAS scale was reduced from 7 to 2. It took about two weeks for the symptoms to decrease by half. Associated symptoms almost did not stay at discharge. In case 2, after treatment hot flush score was reduced from 28 to 2 points. VAS scale was reduced from 10 to 3. And emotional symptoms were reduced about 70%. In case 3, after treatment hot flush score was reduced from 8 to 1 points. VAS scale was reduced from 6 to 1. And headache and chest discomfort symptoms have disappeared. Conclusions : Ascending kidney water and descending heart fire pharmacopuncture treatment is effective for improve ascending kidney water and descending heart fire energy. Therefore, it will be used to alleviate hot flush and sweating.

Air Sampling and Isotope Analyses of Water Vapor and CO2 using Multi-Level Profile System (다중연직농도시스템(Multi-Level Profile System)을 이용한 수증기와 이산화탄소 시료채취 및 안정동위원소 조성 분석)

  • Lee, Dong-Ho;Kim, Su-Jin;Cheon, Jung-Hwa;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.12 no.4
    • /
    • pp.277-288
    • /
    • 2010
  • The multi-level $H_2O/CO_2$ profile system has been widely used to quantify the storage and advection effects on energy and mass fluxes measured by eddy covariance systems. In this study, we expanded the utility of the profile system by accommodating air sampling devices for isotope analyses of water vapor and $CO_2$. A pre-evacuated 2L glass flask was connected to the discharge of an Infrared Gas Analyzer (IRGA) of the profile system so that airs with known concentration of $H_2O$ and $CO_2$ can be sampled. To test the performance of this sampling system, we sampled airs from 8 levels (from 0.1 to 40 m) at the KoFlux tower of Gwangneung deciduous forest, Korea. Air samples in the 2L flask were separated into its component gases and pure $H_2O$ and $CO_2$ were extracted by using a vacuum extraction line. This novel technique successfully produced vertical profiles of ${\delta}D$ of $H_2O$ and ${\delta}^{13}C$ of $CO_2$ in a mature forest, and estimated ${\delta}D$ of evapotranspiration (${\delta}D_{ET}$) and ${\delta}^{13}C$ of $CO_2$ from ecosystem respiration (${\delta}^{13}C_{resp}$) by using Keeling plots. While technical improvement is still required in various aspects, our sampling system has two major advantages over other proposed techniques. First, it is cost effective since our system uses the existing structure of the profile system. Second, both $CO_2$ and $H_2O$ can be sampled simultaneously so that net ecosystem exchange of $H_2O$ and $CO_2$ can be partitioned at the same temporal resolution, which will improve our understanding of the coupling between water and carbon cycles in terrestrial ecosystems.

Plasma-assisted Catalysis for the Abatement of Isopropyl Alcohol over Metal Oxides (금속산화물 촉매상에서 플라즈마를 이용한 IPA 저감)

  • Jo, Jin Oh;Lee, Sang Baek;Jang, Dong Lyong;Park, Jong-Ho;Mok, Young Sun
    • Clean Technology
    • /
    • v.20 no.4
    • /
    • pp.375-382
    • /
    • 2014
  • This work investigated the plasma-catalytic decomposition of isopropyl alcohol (IPA) and the behavior of the byproduct compounds over monolith-supported metal oxide catalysts. Iron oxide ($Fe_2O_3$) or copper oxide (CuO) was loaded on a monolithic porous ${\alpha}-Al_2O_3$ support, which was placed inside the coaxial electrodes of plasma reactor. The IPA decomposition efficiency itself hardly depended on the presence and type of metal oxides because the rate of plasma-induced decomposition was so fast, but the behavior of byproduct formation was largely affected by them. The concentrations of the unwanted byproducts, including acetone, formaldehyde, acetaldehyde, methane, carbon monoxide, etc., were in order of $Fe_2O_3/{\alpha}-Al_2O_3$ < $CuO/{\alpha}-Al_2O_3$ < ${\alpha}-Al_2O_3$ from low to high. Under the condition (flow rate: $1L\;min^{-1}$; IPA concentration: 5,000 ppm; $O_2$ content: 10%; discharge power: 47 W), the selectivity towards $CO_2$ was about 40, 80 and 95% for ${\alpha}-Al_2O_3$, $CuO/{\alpha}-Al_2O_3$ and $Fe_2O_3/{\alpha}-Al_2O_3$, respectively, indicating that $Fe_2O_3/{\alpha}-Al_2O_3$ is the most effective for plasma-catalytic oxidation of IPA. Unlike plasma-alone processes in which tar-like products formed from volatile organic compounds are deposited, the present plasma-catalyst hybrid system did not exhibit such a phenomenon, thus retaining the original catalytic activity.

Nutritional Status of Intensive Care Unit Patients According to the Referral to the Nutrition Support Team and Compliance with the Recommendations (영양집중지원팀 자문 의뢰 및 순응 여부에 따른 중환자실 환자의 영양상태 비교)

  • Sohn, Yunjin;Hyun, Taisun
    • Korean Journal of Community Nutrition
    • /
    • v.27 no.2
    • /
    • pp.121-131
    • /
    • 2022
  • Objectives: This study aimed to examine the effectiveness of the intervention of the nutrition support team (NST) on the nutritional status of critically ill patients. Methods: The medical records of 176 adult patients who were admitted to the intensive care unit and received enteral or parenteral nutrition for more than 7 days were retrospectively analyzed. The patients were classified into the NST and non-NST groups according to whether they were referred to the NST or not. The NST group was further classified into the compliance and non-compliance groups depending on their compliance with the NST recommendations. Results: The NST referral rate was 56.8%, and the rate of compliance with the NST recommendations was 47.0%. Significantly higher energy and protein were provided to the NST and the compliance groups than to the non-NST and the non-compliance groups. The proportion of patients who reached the target calories after the initiation of enteral nutrition was significantly higher in the NST and the compliance groups than in the non-NST and the non-compliance groups. The serum albumin and hemoglobin levels significantly decreased in every group, but the changes were significantly lower in the compliance group. The nutritional status at discharge from the intensive care unit compared to the status at admission was significantly worse in the NST, non-NST, and non-compliance groups. However, the status was maintained in the compliance group. The length of stay in the intensive care unit was significantly shorter in the compliance group. Conclusions: Compliance with the NST recommendations was found to provide more calories and protein and prevent the deterioration of the nutritional status of critically ill patients. Therefore, effective communication between medical staff and the NST from the early stages of admission to the intensive care unit is needed to improve referrals to the NST and compliance with the recommendations.