• 제목/요약/키워드: Effective capacity

검색결과 2,843건 처리시간 0.034초

사무용 건축물 공조설비 설계도서 분석 (Analysis of Office Building HVAC System Drawings)

  • 박종일;김세환;김동규
    • 설비공학논문집
    • /
    • 제19권11호
    • /
    • pp.776-781
    • /
    • 2007
  • Optimized capacity of equipments are essential for energy saving and low cost construction and operation. So we must use proper design data for HVAC system design. We investigated for architectural data, equipment capacity, cooling and heating load design criteria of 52 office buildings. Following research results were obtained by carrying out each task. Office building effective area rate is 63%. The average building cooling load of South Korea is $140W/m^2$ and average heating loads in Seoul and Pusan area are $120{\sim}130W/m^2$ and $70{\sim}80W/m^2$. We also analysised HVAC design criteria. Person ratio in effective building area is $0.2person/m^2$, sensitive and latent heat loads of a person are 60W and 65W, light and equipment loads of office buildings are $25W/m^2$ and $20W/m^2$.

Effects of Heat Processing Time on Total Phenolic Content and Antioxidant Capacity of Ginseng Jung Kwa

  • Oh, Chang-Ho;Kim, Gyo-Nam;Lee, Sang-Hyun;Lee, Jung-Sook;Jang, Hae-Dong
    • Journal of Ginseng Research
    • /
    • 제34권3호
    • /
    • pp.198-204
    • /
    • 2010
  • Korean ginseng (Panax ginseng C.A. Meyer) preserved in syrup, known as ginseng Jung Kwa (GJK), is a popular traditional snack in Korea. We investigated the effects of heat processing time on total phenolic content and antioxidant capacity of GJK. Water extract was prepared from GJK with different heat processing times, 3 hours (GJK-3), 6 hours (GJK-6), or 12 hours (GJK-12), with sonication for 2 hours. The GJK extract contained total phenolic content in the following order: GJK-12 (2.28%)>GJK-6 (1.57%)>GJK-3 (1.29%). Both the peroxy and hydroxyl radical-scavenging activity and cellular antioxidant capacity of GJK extract was significantly enhanced with increasing heat processing time. The hydroxyl radical-scavenging activity of GJK-12 extract was greater than that of the GJK-3 and GJK-6 extracts, consistent with metal chelating capacity and reducing capacity. In a cellular model, the GJK extract effectively reduced 2,2'-azobis(2-amidinopropane) dihydrochloride, $Cu^{2+}$-, and $H_2O_2$-induced oxidative stress, with GJK-12 and GJK-6 extracts demonstrating greater cellular antioxidant capacity than the GJK-3 extract. These results suggest that heat processing time can contribute to the antioxidant capacity of GJK and that GJK extract may have the potential to be used as an effective dietary antioxidant to prevent oxidative stress-related diseases.

선형열원법에 의한 지중유효열전도도와 보어홀 전열저항 해석 (Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Line Source Method)

  • 이세균;우정선;노정근
    • 한국태양에너지학회 논문집
    • /
    • 제30권4호
    • /
    • pp.71-78
    • /
    • 2010
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. The line source method is required by New and Renewable Energy Center of Korea Energy Management Corporation in analyzing data obtained from thermal response tests. Another important factor in designing the ground loop heat exchanger is the borehole thermal resistance($R_b$). There are two methods to evaluate $R_b$ : one is to use a line source method, and the other is to use a shape factor of the borehole. In this study, we demonstrated that the line source method produces better results than the shape factor method in evaluating $R_b$. This is because the borehole thermal resistance evaluated with the line source method characteristically reduces the temperature differences between an actual and a theoretical thermal behaviors of the borehole. Evaluation of $R_b$ requires soil volumetric heat capacity. However, the effect of the soil volumetric heat capacity on the borehole thermal resistance is very small. Therefore, it is possible to use a generally accepted average value of soil volumetric heat capacity($=2MJ/m^3{\cdot}K$) in the analysis. In this work, it is also shown that an acceptable range of the initial ignoring time should be in the range of 8~16hrs. Thus, a mean value of 12 hrs is recommended.

산림환경 변화가 토양내 수저유능력과 유출에 미치는 영향 (Effect of change in forest environment on water storage capacity in soil and streamflow)

  • 남이;박승기
    • 한국토양환경학회지
    • /
    • 제2권2호
    • /
    • pp.35-51
    • /
    • 1997
  • 강원도 평창군 연평면과 용평면 일원에 위치한 백옥포유역과 이목정유역에서 산림의 환경변화(임상차이 및 피해목 벌채)가유출과토양내 수저유능력에 미치는 영향을 구명하기 위하여 1983∼1993년의 유출량, 유출률, 유황곡선등을 분석하였다. 또한 유출 구성성분중 총유출량, 직접유출량, 토양내 가비중, 전공극량, 조공극, 세공극, 투수성, 유출가능수량을 분석하였다. 유출을, 유출량, 유황곡선은 임상이 불량한 이목정유역이 임상이 양호한 백옥포유역보다 높게 나타났으며, 두시험유역 모두에서 전처리기간이 처리기간보다 낮게 나타났다. 또한 벌채에 의한 산림환경변화에 따라 융설촉진 현상이 처리기간에 크게 일어났으며, 융설지연 현상으로 인한 산림효과가 전처리기간에 나타났다 산림환경변화에 따른 토양의 물리적 성질중 가비중, 전공극량(조공극, 세공극), 투수성, 유출가능수량에서도 백옥포유역이 이목정유역보다 양호하였으며, 두 시험유역 모두에서 전처리기간이 처리기간보다 양호한 결과를 나타내어 산림환경 변화에 따른 수자원함양기능의 중요성을 제시하였다.

  • PDF

한국 고유의 산채류 첨가 식이가 흰쥐의 지방 대사 및 항산화능과 Cadmium 제독에 미치는 영향 (Effect of Korean Native Plant Diet on Lipid Metabolism, Antioxidative Capacity and Cadmium Detoxification in Rats)

  • 박진아
    • Journal of Nutrition and Health
    • /
    • 제32권4호
    • /
    • pp.353-368
    • /
    • 1999
  • This study was performed to investigate the effects of Korean native plant diets on lipid and cadmium (Cd) metabolisms and also antioxidative enzyme activities in rats. Seventy male Sprague-Dawley rats weighing 210.3$\pm$2.7g were blocked into ten groups according to body weight. Rats were raised for four weeks with diets containing 0 or 0.04%(w/w) cadmium chloride and 5%(w/w) plant powder-Ssook(Artemisia princeps var. orientalis HARA), Chamchwi(Aster scaber THUNB), Gomchwi(Lingularia fischeri TUBCZ). or Solbeerum (Portulaca oleracea LINNE). Food intake, weight gain, food efficiency ratio, and weights of liver, kidney, spleen and epididymal fat were significantly lower in Cd-exposed groups, food efficiency ratio, and weights of liver, kidney, spleen and epididymal fat were significanlty lower in Cd-exposed groups. Plasma total lipid level, liver total lipid, cholesterol and triglycerde concentrations, and fecal total lipid, cholesterol and triglyceride excretions were decreased by Cd administration. Total lipid and triglyceride concentration in plasma and liver were lower in Chamchwi groups together with increased fecal total lipid and triglyceride excretions. Cholesterol concentration in plasma and liver were lower in Gomchwi groups with increased fecal cholesterol excretions. Activities of red-blood-cell superoxide dismutase(SOD), and liver catalase, SOD and glutathione peroxidase (GSH-px) were decreased significantly by Cd administration. Thiobarbituric acid reactive substance(TBARS) concentrations of plasma and liver were increased by Cd administration. Thiobarbituric acid reactive substance(TBARS) concentration of plasma and liver were increased by Cd administration. Administration of plant diets decreased plasma and liver catalase, SOD and GSH-px activities in Cd-free diet groups and increased them in Cd-administered groups. Plasma and liver TBARS concentrations were decreased in animals fed plant diets, with Chamchwi showing the most effective antioxidative capacity. The concentration of Cd accumulated in blood and tissue decreased in Cd-exposed groups fed plant diets. Liver Cd concentration were lower in the Chamchwi and Gomchwi groups, and kidney Cd levels were lower in the Ssook and Chamchwi groups. Among them, Chamchwi was the most effective in Cd detoxification. In conclusion, Chamchwi and Gomchwi were effective in lowering tissue lipid levels, with Chamchwi having the greatest antioxidative and detoxifying effects.

  • PDF

기반암의 파쇄대 특성을 고려한 지하차도 기초 보강사례 (The Case Study of Rock Treatment Method for the Fractured Rock Foundation of Underground Roadway Structure)

  • 윤지남;양성돈;이근하;박사원;정헌철
    • 터널과지하공간
    • /
    • 제18권2호
    • /
    • pp.125-133
    • /
    • 2008
  • 본 고에서는 파쇄대가 존재하는 기반암 상부에 지하차도를 계획하는 경우, 하부지반의 지지력 증대 및 침하량 감소 목적으로 적용할 수 있는 기초 보강공법에 대하여 연구하였다. 보강효과 및 적정 설치간격을 수치해석적으로 예측함으로써 실제 시공시 기초자료로 활용할 수 있도록 하였다. 이를 위해, 충청남도 연기군 지역에서 수행된 시추조사, 물리탐사 및 실내 실험결과 등을 분석하여 그 결과로부터 파쇄대의 물리적, 역학적특성을 파악하고 지하차도의 지내력을 확보할 수 있는 효과적인 보강대책을 검토하였다. 아울러, 보강사례에서 조사된 공법들 중 이중관 고압분사 공법, 삼중관 고압분사 공법, 마이크로 파일 등의 적정 보강심도를 선정하였으며, 수치해석(Plaxis 8.2 프로그램)을 통해 설치간격 등을 변화시켜가면서 동일한 안정성을 기준으로 가장 효과적인 공법의 제원을 비교 검토하였다.

기상활성화 표면처리된 다중벽 탄소나노튜브의 수소저장거동 (Hydrogen Storage Behaviors of Multi-walled Carbon Nanotubes Modified by Physical Activation Process)

  • 박수진;이슬이;김병주
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.765-768
    • /
    • 2009
  • In this work, we prepared the activated multi-walled carbon nanotubes (Acti-MWNTs) with well developed physical surface structures, high specific surface area, and higher adsorption capacity by a physical activation process, in order to enhance the hydrogen storage capacity. The Acti-MWNTs' changes in the crystalline phase and in their lattice distortions were characterized by X-ray diffraction (XRD). The textural properties of the Acti-MWNTs were investigated by a nitrogen adsorption isotherms by Brunauer-Emmett-Teller (BET) equation and Harvath-Kawazoe (H-K) calculation, respectively. The hydrogen storage capacity of the Acti-MWNTs was investigated by BEL-HP at 298 K/100 bar. The hydrogen storage capacity of the Acti-MWNTs was improved with the physical activation, resulted from the formation of new hydrogen-favorable sites on the Acti-MWNT surfaces. In conclusion, the physical activation was one of the effective method to enhance the hydrogen storage capacity of the MWNTs.

  • PDF

Flexural behaviour and capacity of composite panels of light gage steel and concrete

  • Shi, L.;Liu, Y.;Dawe, J.L.;Bischoff, P.
    • Steel and Composite Structures
    • /
    • 제9권5호
    • /
    • pp.397-418
    • /
    • 2009
  • Eight panel specimens were tested in one-way bending to study the behaviour and capacity of composite slab joists consisting of cold-formed steel C-sections and concrete. Various shear transfer mechanisms were implemented on the C-section flange embedded in the concrete to provide the longitudinal shear resistance. Results showed that all specimens reached serviceability limit state while in elastic range and failure was ductile. Shear transfer achieved for all specimens ranged from 42 to 99% of a full transfer while specimens employed with shear transfer enhancements showed a greater percentage and therefore a higher strength compared with those relying only on surface bond to resist shear. The implementation of pre-drilled holes on the embedded flange of the steel C-section was shown to be most effective. The correlation study between the push-out and panel specimens indicated that the calculated moment capacity based on shear transfer resistance obtained from push-out tests was, on average, 10% lower than the experimental ultimate capacity of the panel specimen.

Cost-effective polyvinylchloride-based adsorbing membrane for cationic dye removal

  • Namvar-Mahboub, Mahdieh;Jafari, Zahra;Khojasteh, Yasaman
    • Membrane and Water Treatment
    • /
    • 제11권2호
    • /
    • pp.131-139
    • /
    • 2020
  • The current study focused on the preparation of low-cost PVC-based adsorbing membrane. Metakaolin, as available adsorbent, was embedded into the PVC matrix via solution blending method. The as-prepared PVC/metakaolin mixed matrix membranes were characterized using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy, atomic force microscopy (AFM), pure water permeability and contact angle measurements. The results confirmed the improvement of PWP and hydrophilicity due to the presence of metakaolin in the PVC matrix. Additionally the structure of PVC membrane was changed due to the incorporation of metakaolin in the polymer matrix. The static adsorption capacity of all samples was determined through dye removal. The effect of metakaolin dosage (0-7%) and pH (4, 8, 12) on dye adsorption capacity was investigated. The results depicted that the highest adsorption capacity was achieved at pH of 4 for all samples. Additionally, adsorption data were fitted on Langmuir, Freundlich, and Temkin models to determine the appropriate governing isotherm model. Finally, the dynamic adsorption capacity of the optimum PVC/metakaolin membrane was studied using dead-end filtration cell. The dye removal efficiency was determined for pure PVC and PVC/metakaolin membrane. The results demonstrated that PVC/metakaolin mixed matrix membrane had a high adsorption capacity for dye removal from aqueous solution.

Partial sectional confinement in a quasi-encased steel-concrete composite beam

  • Hassanzadeh, Amir Masoud;Dehestani, Mehdi
    • Computers and Concrete
    • /
    • 제22권3호
    • /
    • pp.269-278
    • /
    • 2018
  • In the recent decades, the application of composite materials, due to their desirable properties, has increased dramatically. In the present study, a quasi-encased trapezoidal section composite steel beam encased with concrete is thoroughly examined. Calculation of the load bearing capacity is carried out by finite element modeling of concrete and FRP beams with trapezoidal section under the effect of controlled displacement loading. The results are then validated comparing to the existing experimental results obtained from similar studies. Further on, the materials are changed to steel and concrete, and the section is de-signed in such a way that both concrete and steel reach a high percent-age of their load bearing capacity. In the last step, the parameters affecting the bending capacity and the behavior of the semi-confined composite beam are investigated. Results revealed that the beam diagonal web thickness plays the most effective role in load bearing capacity amongst other studied parameters. Furthermore, by analyzing the results on the effect of different parameters, an optimal model for primary beam section is presented, which exhibits a greater load bearing capacity compared to the initial design with the same amount of materials used for both sections.