• Title/Summary/Keyword: Effective block

Search Result 1,157, Processing Time 0.027 seconds

The Effects of Stellate Ganglion Block for Constipation in the Spinal Cord Injured Patients -Report of 2 Cases- (척수손상환자의 변비에 있어서 성상신경절 차단의 효과 -2예 보고-)

  • Yang, Nae-Yun;Moon, Dong-Eon;Suh, Jae-Hyun
    • The Korean Journal of Pain
    • /
    • v.7 no.2
    • /
    • pp.254-257
    • /
    • 1994
  • In the patients having constipation or irritable bowel syndrome, stellate ganglion block is commonly used in many pain clinics because of its excellent effects. But in the case of patients having spinal cord injury complain constipation, its management is very difficult and there is no report about the effects of stellate ganglion block in this case. We experieced good results that stellate ganglion block was very effective in the patients having spinal cord injury complaining severe constipation and other symptoms.

  • PDF

CT Guided Celiac plexus Block (CT를 이용한 복강신경총 차단)

  • Kim, Jong-Il;Park, No-Cheon;Go, Joon-Seock;Min, Byung-Woo
    • The Korean Journal of Pain
    • /
    • v.1 no.1
    • /
    • pp.28-33
    • /
    • 1988
  • Neurolysis of the celiac plexus has been performed to relieve intractable pain caused by carcinoma of the pancreas, liver, gall bladder or stomach. It is also occasionally effective in controlling the pain of chronic pancreatitis. In practice, however celiac plexus block is not a simple procedure to the beginner. The results and complications are variable. In order to correctly inject neurolytic agents into or near the celiac plexus and to reduce the time consumed to perform celiac plexus block, we used CT scanner for 7 cases of alcohol celiac plexus block. The effects will be described. The purpose of this article is to improve the technical aspect of celiac plexus block to the beginner.

  • PDF

Impossible Differential Cryptanalysis on DVB-CSA

  • Zhang, Kai;Guan, Jie;Hu, Bin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.4
    • /
    • pp.1944-1956
    • /
    • 2016
  • The Digital Video Broadcasting-Common Scrambling Algorithm is an ETSI-designated algorithm designed for protecting MPEG-2 signal streams, and it is universally used. Its structure is a typical hybrid symmetric cipher which contains stream part and block part within a symmetric cipher, although the entropy is 64 bits, there haven't any effective cryptanalytic results up to now. This paper studies the security level of CSA against impossible differential cryptanalysis, a 20-round impossible differential for the block cipher part is proposed and a flaw in the cipher structure is revealed. When we attack the block cipher part alone, to recover 16 bits of the initial key, the data complexity of the attack is O(244.5), computational complexity is O(222.7) and memory complexity is O(210.5) when we attack CSA-BC reduced to 21 rounds. According to the structure flaw, an attack on CSA with block cipher part reduced to 21 rounds is proposed, the computational complexity is O(221.7), data complexity is O(243.5) and memory complexity is O(210.5), we can recover 8 bits of the key accordingly. Taking both the block cipher part and stream cipher part of CSA into consideration, it is currently the best result on CSA which is accessible as far as we know.

Error Concealment Using Intra-Mode Information Included in H.264/AVC-Coded Bitstream

  • Kim, Dong-Hyung;Jeong, Se-Yoon;Choi, Jin-Soo;Jeon, Gwang-Gil;Kim, Seung-Jong;Jeong, Je-Chang
    • ETRI Journal
    • /
    • v.30 no.4
    • /
    • pp.506-515
    • /
    • 2008
  • The H.264/AVC standard has adopted new coding tools such as intra-prediction, variable block size, motion estimation with quarter-pixel-accuracy, loop filter, and so on. The adoption of these tools enables an H.264/AVC-coded bitstream to have more information than was possible with previous standards. In this paper, we propose an effective spatial error concealment method with low complexity in H.264/AVC intra-frame. From information included in an H.264/AVC-coded bitstream, we use prediction modes of intra-blocks to recover a damaged block. This is because the prediction direction in each prediction mode is highly correlated to the edge direction. We first estimate the edge direction of a damaged block using the prediction modes of the intra-blocks adjacent to a damaged block and classify the area inside the damaged block into edge and flat areas. Our method then recovers pixel values in the edge area using edge-directed interpolation, and recovers pixel values in the flat area using weighted interpolation. Simulation results show that the proposed method yields better video quality than conventional approaches.

  • PDF

The Life Cycle Cost Estimation for Domestic Products Motor Block of KTX-1 Considering Periodic Maintenance (유지보수정보 주기를 고려한 KTX-1 모터블럭 개발품의 수명주기비용 예측)

  • Yun, Cha-Jung;Noh, Myoung-Gyu;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.288-292
    • /
    • 2013
  • This paper presents the result of life-cycle cost (LCC) estimation for domestic products propulsion control system (motor block unit) of KTX-1 considering periodic maintenance. Life cycle costing is one of the most effective approaches for the cost analysis of long-life systems such as the KTX-1. Life cycle costing includes the cost of concept design, development, manufacture, operation, maintenance and disposal. To estimate LCC for domestic products motor block unit, it was analyzed physical breakdown structure (PBS) on motor unit in view of maintenance cost and unit cost etc. As a results, life cycle cost on motor block unit increased moderately expect for periodical time when major parts are replaced at the same time. hereafter this results will be reflected in the domestic products being developed.

Block-VN: A Distributed Blockchain Based Vehicular Network Architecture in Smart City

  • Sharma, Pradip Kumar;Moon, Seo Yeon;Park, Jong Hyuk
    • Journal of Information Processing Systems
    • /
    • v.13 no.1
    • /
    • pp.184-195
    • /
    • 2017
  • In recent decades, the ad hoc network for vehicles has been a core network technology to provide comfort and security to drivers in vehicle environments. However, emerging applications and services require major changes in underlying network models and computing that require new road network planning. Meanwhile, blockchain widely known as one of the disruptive technologies has emerged in recent years, is experiencing rapid development and has the potential to revolutionize intelligent transport systems. Blockchain can be used to build an intelligent, secure, distributed and autonomous transport system. It allows better utilization of the infrastructure and resources of intelligent transport systems, particularly effective for crowdsourcing technology. In this paper, we proposes a vehicle network architecture based on blockchain in the smart city (Block-VN). Block-VN is a reliable and secure architecture that operates in a distributed way to build the new distributed transport management system. We are considering a new network system of vehicles, Block-VN, above them. In addition, we examine how the network of vehicles evolves with paradigms focused on networking and vehicular information. Finally, we discuss service scenarios and design principles for Block-VN.

Adsorption Stabilization of $TiC_{2}$ Particles in Water Soluble Block Copolymers (수용성 블록공중합물에서 산화티탄 분말의 흡착 안정화)

  • Kwan, Soun-Il;Jeong, Hwan-Kyeong;Choi, Seung-Ok;Nam, Ki-Dae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.118-126
    • /
    • 2001
  • Micelle formation and adsorption at the $Ti0_{2}$ interface of a series of polystyrene-polythylene oxide(PS-PEO) block copolymer in aqueous solution was studied using fluorescence probing and small-angle X-ray methods. Further, the stability of aqueous $Ti0_{2}$ dispersion in the presence of copolymer was investigated by microelectrophoresis, optical density and sedimentation measurements. The dissolution of pyrene as fluorescent probe in aqueous surfactant solution leads to a slow decrease of the $I_{1}/I_{3}$ ratio, as the copolymer concentration increase; $I_{1}$ and $I_{3}$ are respectively the intensities of the first and third vibrionic peaks in the pyrene fluorescence emission. The behaviour was due to the characteristics of the copolymers and/or to the copolymer association efficiency in water. Moreover, the adsorption at the plateau level increases with decreasing PEO until chain length. The zeta potential of $TiO_{2}$ particles decreases with increasing copolymer concentration and reaches a plateau value. Finally, stabilization using block copolymers was more effective with samples having higher weight fractions of PS block.

Adaptive Error Detection Using Causal Block Boundary Matching in Block-Coded Video (블록기반 부호화 비디오에서 인과적 블록 경계정합을 이용한 적응적 오류 검출)

  • 주용수;김태식;김남철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.8C
    • /
    • pp.1125-1132
    • /
    • 2004
  • In this Paper, we Propose an effective boundary matching based error detection algorithm using causal neighbor blocks to improve video quality degraded from channel error in block-coded video. The proposed algorithm first calculates boundary mismatch powers between a current block and each of its causal neighbor blocks. It then decides that a current block should be normal if all the mismatch powers are less than an adaptive threshold, which is adaptively determined using the statistics of the two adjacent blocks. In some experiments under the environment of 16bi1s burst error at bit error rates (BERs) of 10$^{-3}$ -10$^{-4}$ , it is shown that the proposed algorithm yields the improvements of maximum 20% in error detection rate and of maximum 3.5㏈ in PSNR of concealed kames, compared with Zeng's error detection algorithm.

THE REVERSE TWIN BLOCK APPLIANCE WITH REMOVABLE LIP PADS (가철식 Lip Pad가 부가된 Reverse Twin Block 장치)

  • Kim, Sung-Ki;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.1
    • /
    • pp.32-37
    • /
    • 1999
  • Twin blocks are bite-blocks that effectively modify the occlusal inclined plane to induce favorably directed occlusal forces by causing a functional mandibular displacement. One of the advantage is that full-time wear can be possible because of less interference with normal function such as eating and speaking. So rapid correction of malocclusion is expected. Reverse twin block appliance is modification for correction of class III malocclusion with sagittal component. For increased growth stimulation effort on premaxilla, lip pads can be added. But with lip pads, patients are incapable of full-time wear especially during mealtime. So, removable lip pads can be used for stimulation of growth on premaxilla without any restriction of function. The advantages of the reverse twin block appliance with removable lip pads are: 1. Full-time wear is possible (including mealtime). 2. Patients' cooperation and adaptation is excellent. 3. There is no period of dual bite. 4. Orthopedic correction is achieved by multiple modes, shortening the treatment time. The applied case shows that the reverse twin block appliance with removable lip pads is effective for treatment of class III malocclusion and can shorten the time of treatment.

  • PDF

Clinical Outcome of Percutaneous Trigeminal Nerve Block in Elderly Patients in Outpatient Clinics

  • Seo, Hyek Jun;Park, Chang Kyu;Choi, Man Kyu;Ryu, Jiwook;Park, Bong Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.6
    • /
    • pp.814-820
    • /
    • 2020
  • Objective : Trigeminal neuralgia (TN) is a severe neuropathic condition that affects several elderly patients. It is characterized by uncontrolled pain that significantly impacts the quality of life of patients. Therefore, the condition should be treated as an emergency. In the majority of patients, pain can be controlled with medication; however, other treatment modalities are being explored in those who become refractory to drug treatment. The use of the trigeminal nerve block with a local anesthetic serves as an excellent adjunct to drug treatment. This technique rapidly relieves the patient of pain while medications are being titrated to effective levels. We report the efficacy and safety of percutaneous trigeminal nerve block in elderly patients with TN at our outpatient clinic. Methods : Twenty-one patients older than 65 years with TN received percutaneous nerve block at our outpatient clinic. We used bupivacaine (1 mL/injection site) to block the supraorbital, infraorbital, superior alveolar, mental, and inferior alveolar nerves according to pain sites of patients. Results : All patients reported relief from pain, which decreased by approximately 78% after 2 weeks of nerve block. The effect lasted for more than 4 weeks in 12 patients and for 6 weeks in two patients. There were no complications. Conclusion : Percutaneous nerve block procedure performed at our outpatient clinic provided immediate relief from pain to elderly patients with TN. The procedure is simple, has no serious side effects, and is easy to apply.