• Title/Summary/Keyword: Effective SNR

Search Result 166, Processing Time 0.022 seconds

Comparative Evaluation of Single-Energy CT and Dual-Energy CT in Brain Angiography : Using a Rando Phantom and OSLD (뇌혈관조영검사 시 단일에너지 CT와 이중에너지 CT의 비교평가 : 화질 및 유효선량평가)

  • Byeong-Geun Shin;Seong-Min Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.809-817
    • /
    • 2023
  • Single source and dual source measurements using anthropomorphic phantoms in which the phantoms are lined up in human body equivalents use OSLD (Optically Stimulated Luminescence Dosimeter), so the effective dose is calculated using OSLD. For hospital images, SNR (Signal to Noise Ratio) and CNR (Contrast to Noise Ratio) were measured in MCA (Middle Cerebral Artery) for single source and dual source, and for phantom images, SNR and CNR were measured for brain parenchyma of single source and dual source. For hospital imaging, SNR and CNR were measured in MCA for both single-source and dual-source, and for phantom images, SNR and CNR were measured for brain parenchyma from single-source and dual-source. As a result of comparing the SNR and CNR of the hospital image and the phantom image, there was no statistical difference. Comparing patient doses in hospital images, the effective dose of the dual source was 53.53% less and the effective dose of the dual energy phantom was 57.94% less. The dose can be increased in other areas, but the cerebrovascular area is useful because the dose is small.

A Comparative Study of CTDI and the Effective Dose and the SNR according to the Area in the Abdominal CT (복부CT에서 면적에 따른 CTDI와 유효선량 및 SNR의 비교 연구)

  • Choi, Sung-Jun;Kang, Jun-Guk;Kim, Su-In;Kim, Youn-Ho;Lee, Do-Gyeong;Jung, Jin-Gyung;Cho, Ar-A;Jang, Jae-Hyeok;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.245-252
    • /
    • 2015
  • To obtain the best SNR (signal to noise ratio) due to changes in CTDI (computed tomography dose index) made for the purpose of setting the optimum image obtained by reducing the dose in abdominal CT. Abdominal CT scans of 59 patients a $400-499cm^2$ (n = 12), $500-599cm^2$ (n = 21), $600-699cm^2$ (n = 17), $700-799cm^2$ (n = 9) were separated by four groups and the effective dose was used in the Excel to get the area of the patient using the ImageJ program. Patients of CTDI, DLP, SNR, the effective dose were analyzed. Abdominal CT area was increased to 13 mGy in CTDI is 7.3 mGy, DLP to 732 in $394.4mGy{\cdot}cm$, also effective dose was 5.9 mSv increase in 11mSv. SNR is 15 dB was maintained at 12.7. CTDI according to the average of the abdominal area of 8.9 mGy, the average of the DLP was $481.54mGy{\cdot}cm$, the effective dose is calculated to be 7.2 mSV. Effective dose was calculated by multiplying the load factor of DLP in the abdomen showed no statistically significant difference of (p < .05), there was a significant difference in SNR (p > . 05). To improve image quality of abdominal CT scan image in consideration of the CTDI according to the volume of the patient it should be able to reduce the radiation exposure of the patients.

A Selection Transmit Diversity with Adaptive Modulation (적응변조를 이용한 선택적 송신 다이버시티 기술)

  • 김준오;권종만;임창헌
    • Proceedings of the IEEK Conference
    • /
    • 2001.06a
    • /
    • pp.65-68
    • /
    • 2001
  • The selection transmit diversity is an effective way to avoid the deep fading in a wireless channel. However, it may not completely eliminate the SNR fluctuation of a received signal at the receiver. This letter presents an application of an adaptive modulation effectively exploiting the SNR variation over time for a higher spectral efficiency to the conventional selection transmit diversity. Numerical results show that the proposed scheme can achieve a SNR gain of about 7 dB over the conventional selection diversity in a flat Rayleigh fading environment, when a BER of 10$^{-3}$ and a spectral efficiency of 2 bps/Hz are required..

  • PDF

A Study on the Context-dependent Speaker Recognition Adopting the Method of Weighting the Frame-based Likelihood Using SNR (SNR을 이용한 프레임별 유사도 가중방법을 적용한 문맥종속 화자인식에 관한 연구)

  • Choi, Hong-Sub
    • MALSORI
    • /
    • no.61
    • /
    • pp.113-123
    • /
    • 2007
  • The environmental differences between training and testing mode are generally considered to be the critical factor for the performance degradation in speaker recognition systems. Especially, general speaker recognition systems try to get as clean speech as possible to train the speaker model, but it's not true in real testing phase due to environmental and channel noise. So in this paper, the new method of weighting the frame-based likelihood according to frame SNR is proposed in order to cope with that problem. That is to make use of the deep correlation between speech SNR and speaker discrimination rate. To verify the usefulness of this proposed method, it is applied to the context dependent speaker identification system. And the experimental results with the cellular phone speech DB which is designed by ETRI for Koran speaker recognition show that the proposed method is effective and increase the identification accuracy by 11% at maximum.

  • PDF

Effect Analysis of Timing Offsets for Asynchronous MC-CDMA Uplink Systems (비동기 MC-CDMA 상향 링크 시스템에서의 시간 옵셋 영향 분석)

  • Ko, Kyun-Byoung;Woo, Choong-Chae
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.8
    • /
    • pp.1-8
    • /
    • 2010
  • This paper models a symbol timing offset (STO) with respect to the guard period and the maximum access delay time for asynchronous multicarrier code division multiple access (MC-CDMA) uplink systems over frequency-selective multipath fading channels. Analytical derivation shows that STO causes desired signal power degradation and generates self-interferences. This effect of the STO on the average bit error rate (BER) and the effective signal-to-noise ratio (SNR) is evaluated. The approximated BER and the SNR loss caused by STO are then obtained as closed-form expressions. The tightness between the analytical result and the simulated one is verified for the different STOs and SNRs. Furthermore, the derived analytical results are verified via Monte Carlo simulations.

High SNR Analysis of User-Multiplexing Technique Provisioning Delay QoS in OFDMA Systems (OFDMA 시스템에서 지연 QoS를 지원하는 2-D 사용자 다중화 기법에 대한 높은 SNR영역에서의 성능 분석)

  • Ahn, Seong-Woo;Hong, Dae-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.4
    • /
    • pp.77-83
    • /
    • 2011
  • In this paper, we study the throughput-delay tradeoff of OFDMA systems in context of 2-dimensional resource allocation, and analyze the effect of frequency diversity and user-multiplexing in time domain that has on delay QoS performance. Based on the analysis results, we investigate the impacts of delay QoS on spectral efficiency. In high SNR regime, the optimal DoM (degree of multiplexing) maximizing the spectral efficiency is identified. The results of the high SNR analysis can give us an intuition on an efficient resource allocation policy. Finally, through the simulation results, we verify that our approach with its optimal DoM yields substantial capacity gain.

Efficient and Secure Routing Protocol forWireless Sensor Networks through SNR Based Dynamic Clustering Mechanisms

  • Ganesh, Subramanian;Amutha, Ramachandran
    • Journal of Communications and Networks
    • /
    • v.15 no.4
    • /
    • pp.422-429
    • /
    • 2013
  • Advances in wireless sensor network (WSN) technology have enabled small and low-cost sensors with the capability of sensing various types of physical and environmental conditions, data processing, and wireless communication. In the WSN, the sensor nodes have a limited transmission range and their processing and storage capabilities as well as their energy resources are limited. A triple umpiring system has already been proved for its better performance in WSNs. The clustering technique is effective in prolonging the lifetime of the WSN. In this study, we have modified the ad-hoc on demand distance vector routing by incorporating signal-to-noise ratio (SNR) based dynamic clustering. The proposed scheme, which is an efficient and secure routing protocol for wireless sensor networks through SNR-based dynamic clustering (ESRPSDC) mechanisms, can partition the nodes into clusters and select the cluster head (CH) among the nodes based on the energy, and non CH nodes join with a specific CH based on the SNR values. Error recovery has been implemented during the inter-cluster routing in order to avoid end-to-end error recovery. Security has been achieved by isolating the malicious nodes using sink-based routing pattern analysis. Extensive investigation studies using a global mobile simulator have shown that this hybrid ESRP significantly improves the energy efficiency and packet reception rate as compared with the SNR unaware routing algorithms such as the low energy aware adaptive clustering hierarchy and power efficient gathering in sensor information systems.

The Study of Radiation Exposure Reduction by Developing Corpus Striatum Phantom (두개골-선조체 팬텀을 이용한 선량 저감화 방안 연구)

  • Kim, Jung-Soo;Park, Chan-Rok
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.595-603
    • /
    • 2017
  • The study is to produced a brain phantom simulating corpus striatum, which can evaluate the progression of parkinson's disease, to investigate possibility of reducing the brain exposure dose to CT while maintaining optimal image quality during PET-CT examinations. CT scans were performed by varying tube voltage (100, 120 kVp) and tube current (80, 140, 200 mAs) with $^{18}F$ FP-CIT injected into the phantom's hot sphere and background (radioactivity ratio 3:1)(reference condition; 120 kVp, 140 mAs). Estimated effective dose was calculated by using conversion factor according to each condition, and image quality was evaluated by setting SNR and CRChot image evaluation factors. Experimental results showed that the predicted effective dose below the CT imaging reference condition was reduced by at least 10% and by up to 60%, and the predicted effective dose beyond the reference condition was increased by 40%. In addition, there was no significant difference between SNR and CRChot of PET images, and it was confirmed that brain dose decreased with decrease of tube voltage and tube current. At the same time, there was no significant change in the quality of the image in terms of SNR and CRChot despite the change in scan conditions. This fact suggests that the quality of the images acquired under the existing dose conditions can be obtained even at low dose conditions and it is expected that it will be possible to use the brain PET-CT scan as a basic data for the research on reduction of dose and improvement of image quality.

The Effect of Source to Image-Receptor Distance(SID) on Radiation Dose for Digital Chest Radiography (Digital Chest Radiography에서 방사선량에 대한 Source to Image-Receptor Distance (SID)의 영향)

  • Kwon, Soonmu;Park, Changhee;Park, Jeongkyu;Son, Woonheung;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.203-210
    • /
    • 2014
  • Chest radiography has been typically performed at SID of 180 cm. Image quality and patient dose were investigated between 180 cm and 340 cm by 20 cm intervals at 120 kVp and 320 mAs with the AEC. VGA was performed for qualitative assessment and SNR was analysed for quantitative assessment on the image of the chest phantom. Patients dose was measured by ESAK and PCXMC was used for effective dose. As a result, when using the standard of SID of 180 cm which is typically used in the clinical practice, in the case of ESAK, 240 cm, 280 cm, and 320 cm were 8.7%, 11.47%, and 13.56% respectively therefore significant reduction was confirmed. In the case of effective dose, 2.89%, 4.67%, and 6.41% in the body and 5.08%, 6.09%, and 9.6% in lung were reduced. In the case of SNR, 9.04%, 8.24%, and 11.46% were respectively decreased especially, by 8.03% between SID of 260 cm and 300 cm, but SNR was 5.24 up to 340 cm. There were no significant differences in VGA thus the image is valuable in diagnosis. It is predicted that increasing SID up to 300 cm in digital chest radiography can reduce patient dose without decreasing image quality.

Simultaneous Transmission of Multiple Unicast and Multicast Streams Using Non-orthogonal Multiple Access (비직교 다중접속 방식을 이용한 다중 유니캐스트와 멀티캐스트 스트림 동시 전송)

  • Shin, Changyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.11-19
    • /
    • 2021
  • In this paper, we propose a non-orthogonal multiple access (NOMA) method based on channel alignment to simultaneously transmit multiple unicast and multicast streams in frequency-efficient manner. In this method, all receivers in a multicast cluster use the receive beamforming vectors that align their channels, and the base station uses the aligned channel information to design the transmit beamforming vectors that eliminate interference between multicast clusters. Using the effective receive channel information combined with the transmit beamforming vectors, unicast receivers design their own receive beamforming vectors that eliminate interference between unicast receivers. Since the proposed method effectively eliminates the interference, it achieves a higher sum rate than the existing orthogonal multiple access (OMA) method in high SNR regions. In addition, we present a hybrid method that exploits the benefits of the proposed NOMA method and the existing OMA method. Depending on the channel state, the hybrid method adaptively employs the existing OMA method, which improves the received signal power, in low SNR regions and the proposed NOMA method, which effectively eliminates the interference, in high SNR regions, thereby achieving a good sum rate over the entire SNR region.