• Title/Summary/Keyword: Effective Flow Area

Search Result 468, Processing Time 0.031 seconds

The Analysis of the Effect of Spatial Variability in Land Use and Pollutant Source on the Stream Water (유역에서 토지이용과 오염원자료의 공간적 변화가 하천수질에 미치는 영향 분석)

  • Jung, Kwang-Wook;Lee, Seung-Jae;Lee, Sang-Woo;Han, Jung-Yoon
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.1
    • /
    • pp.40-49
    • /
    • 2007
  • For effective watershed management, we must understand the complex and dynamic relationships of land uses and water quality. Despite numerous studies investigated the relationships between water quality and land use, there are increasing concerns on the geographical variation and lack of spatial integrations in previous studies. We investigated the relationships between land use and water quality characteristics in the Hwa-Sung estuarine reservoir watershed in Korea, which has spatially integrated land uses. The spatial variations of these relationships were also examined using zonal analysis. Water quality parameter were correlated positively with residential and forest and negatively with paddy and upland especially during base flow in the near buffer zone. During storm flow, correlation between land use and water quality was less apparent. Population and livestock density was correlated well to water quality parameter than just number of population and livestock. Relationships across zones, distinguished by distances from streams, were inconsistent and erratic, suggesting that the relationships between remote land uses and water quality may be affected more significantly by sub-basin characteristics than by the land use itself. The watersheds studied are mainly non-urban and their land uses are similar to typical watershed of other estuarine reservoirs, therefore, the correlation developed in this study might be helpful to manage other watersheds of estuarine reservoir. This methodology could be applied to other areas where the watershed characteristics are not significantly different from the study area.

Closing Characteristics of a Main Oxidizer Shut-off Valve (연소기 산화제 개폐밸브 닫힘 작동특성)

  • Hong, Moongeun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.9
    • /
    • pp.717-724
    • /
    • 2020
  • We study the closing characteristics of a self-sustainable poppet valve which serves as a main oxidizer shut-off valve for liquid rocket engines. Numerical analysis for predicting closing transient responses are presented and the calculated results have been verified by a comparison with experimental data. The effective area of a pilot gas discharge system and the pressure distribution of passage flow around the valve moving part are shown to be main parameters in determining the closing characteristics for dry and cryogenic conditions, respectively. Moreover, it is presented that the passage flow pressure at the valve closing moment as well as the valve closing velocity can be effectively adjusted by the appropriate employment of the pilot gas.

Numerical Simulation for the Subsurface Temperature Distribution Disturbed by Heat-Pump Operation (지열펌프 구동에 의한 지중 온도 분포 변화 모델링 연구)

  • Shin, Ji-Youn;Bae, Gwang-Ok;Lee, Kang-Kun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.40-43
    • /
    • 2006
  • Public demand for the heat pump system as a next generation energy equipment is increasing for its eco-friendly and cost-effective advantage. Many researches have been concentrated on how to calculate and develop its own efficiency, while the possible effect of the heat pump operation on the whole subsurface temperature distribution is relatively less considered, During the current study, subsurface temperature disturbance caused by seasonal surface temperature cycle in Busan area and general W-tube heat pump operation is simulated in 3-dimensional heterogeneous medium. It shows that subsurface deeper than 10m from the surface remains nearly unchanged throughout the 4 seasons and groundwater convect ion in highly permeable layer near the surface acts like a main path of heat plume from heat pump system, This implies the significance of detail descript ion in shallow sedimentary layer or highly permeable layer which plays an important role on the regional flow advection and heat transfer. Also, the effect of groundwater convection increases when the arrangement of the 2 injection pipes and 2 extract ion well is maintained parallel to groundwater flow. Therefore, more careful and detail investigation is required before installation and operation of heat pump system that it may not cause any possible change of microbial ecosystem in the shallow subsurface environment or 'contamination of temperature' for groundwater use as well as the loss of efficiency of the equipment itself. This can also help to design the optimized grouting system for heat pump.

  • PDF

Runoff Reduction Effect of Rainwater Retentive Green roof (저류형 옥상녹화의 우수유출저감에 대한 연구)

  • Baek, So-Young;Kim, Hyun-Woo;Kim, Mi-Kyeong;Han, Moo-Young
    • KIEAE Journal
    • /
    • v.16 no.1
    • /
    • pp.67-71
    • /
    • 2016
  • Purpose: There is a growing interest in rainwater runoff reduction effect of green roof, as flooding caused by increasing impervious surface is becoming more and more frequent in urban areas. This study was conducted to prove runoff reduction and runoff delay effect of the retentive green roof and to investigate its influencing factors to the rainfall events that occurred in the summer of 2013. Method: The experiment intended to monitor the runoff quantity of the retentive green roof($140m^2$) and normal roof($100m^2$) in #35 building in Seoul National University, Seoul, Korea for 75 days in 2013. Result: On analysis of 9 rainfall events, it showed that the retentive green roof has 24.8~100% of runoff reduction ratio, 21.2~100% of peak flow reduction ratio, 0.5~3.75 hours of peak delay, and $1.8{\sim}7.2m^3$ of retaining capacity in an area of $140m^2$. It shows different results depending on rainfall and antecedent dry days. The results show that runoff reduction effect is effective when the rainfall is less than 50 mm and antecedent dry day is longer than five days on average. By installing retentive green roofs on buildings, it can help mitigate urban floods and rehabilitate urban water cycle.

Experimental Study on Thermal Insulation and Cooling for Rotor/Bearing Area in 500W Class Micro Gas Turbine Generator (500W급 마이크로 가스터빈 발전기 회전체-베어링부의 단열 및 냉각 성능에 대한 실험적 연구)

  • Park, Cheol Hoon;Choi, Sang Kyu;Ham, Sang Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.3
    • /
    • pp.19-24
    • /
    • 2014
  • Development of long-term mobile energy sources for mobile robots or small-sized unmanned vehicles are actively increasing. The micro gas turbine generator (MTG) is a good candidate for this purpose because it has both of high energy density and high power density, and 500W class MTG is under development. The designed MTG can be divided into 2 main parts. One part consists of motor/ generator and compressor, and the other one consists of combustor, recuperator and turbine. 500W class MTG is designed to operate at ultra-high speed of 400,000 rpm in high turbine temperature over $700^{\circ}C$ to improve the efficiency. Because the magnetism of NdFeB permanent magnet for the motor/generator could be degraded if the temperature is over $150-200^{\circ}C$, MTG needs the thermal insulation to block the heat transfer from combustor/turbine side to motor/generator side. Moreover, the motor/generator is allocated to get the cooling effect from the rapid air flow by the compressor. This study presents the experimental results to verify whether the thermal insulator and air flow are effective enough to keep the motor/generator part in the low temperature less than $100^{\circ}C$. From the motoring test by using the high temperature test rig, it was confirmed that the motor/generator part could maintain the temperature less than $50^{\circ}C$ under the condition of 1.0 bar compressed air.

Treatment of Intraoperative Thrombosis and Spasm in Free Tissue Transfers Using the Fogarty Catheter (포가티 카테터를 이용한 유리조직 전이술 시 수술 중 혈전 및 연축의 치료)

  • Lee, Seung Ryul;Yun, Young Mook;Oh, Sang-Ha
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.159-164
    • /
    • 2008
  • Purpose: Microvascular free tissue transfer has become a reliable technique for the reconstruction of complex wounds. Occasionally, unexpected intraoperative thrombosis and/or spasm of recipient artery might be annoying problems even for the technically competent microvascular surgeons. If such problems are not treated properly, they will inevitably cause to flap failure. Methods: From January 2006 to February 2007, soft tissue reconstructions by free tissue transfers were performed on 21 patients having complex defects in the lower extremity. Although segmental revision and various pharmacologic agents were repeatedly applied, arterial occlusions were not managed in 6 cases. For removal of thrombi and release of spasm, Fogarty No. 2 or No. 3 catheters were inserted into the lumen to the proximal recipient artery. Its balloon was then inflated after passing through a resistant area. Next, the catheter was gently withdrawn backward. Results: After the Fogarty catheter was inserted two or three times, the pulsatile arterial flow was restored. When the catheter was inserted into the lumen, a feeling of resistance existed in a 5-10cm more proximal portion that could not be easily accessed from the vascular end. After the reestablishment of blood flow, successful anastomoses were achieved and immediate rethrombosis or spasm did not occur. No long-term sequelae associated with balloon trauma to the arterial wall were observed. Conclusion: The use of the Fogarty catheter can be an effective method in treating pedicle thrombosis and spasm. This is a very simple and rapid technique that offers microvascular surgeons another option to increase the success rate of microvascular anastomosis in free tissue transfers.

Study on clinical chemistry and DNA ploidy pattern changes in carcinogenesis of the rat liver and kidney (간과 선장의 암유발과정에서 혈액화학효소 및 DNA ploidy pattern 의 변화에 대한 조사)

  • Jeong, Ja-Young;Jang, Dong-Deuk;Cho, Jae-Cheon;Lee, Yong-Soon
    • Korean Journal of Veterinary Pathology
    • /
    • v.2 no.2
    • /
    • pp.73-84
    • /
    • 1998
  • This study was carried out to investigate on the serum chemistry and the DNA ploidy changes in carcinogenesis of the rat liver and kidney. Sixty male Sprague-Dawley rats were divided into two groups. Group I was non-treated control. Group II was given initiators (2,2'-dihydroxy- di-N-propylnitrosamine, 0.1% in drinking water(d.w.) for 1 week and N-ethyl-N-hydroxy-ethylnitrosamine; 0.15% in d.w. for 1 week) and promoters (3'methyl-cholanthrene; 3'MC, l0mg/kg, intraperitoneally(i.p.) twice a week and DL-serine; 0.05% in d.w. for 5 weeks, from 3 to 8 weeks). All examinations were performed at 12 and 20 weeks RBC, HGBCp<0.05) and PCVCp<0.01) significantly decreased in Group II at 20 weeks. Activities of ALT, AST(p<0.05) and GGT(p<0.01) were significantly increased in Group II at 20 weeks. Flow cytometric analysis showed hepatocyte nuclei from normal livers were predominantly tetraploid(66~67%) and then diploid(28~30%). Most of hepatocyte nuclei from carcinogen-treated rats were diploid (52~68%) and less were tetraploid(28~42%). Neoplastic liver nodules and hepatocellular carcinoma contained almost exclusively diploid nuclei. Renal cell nuclei from normal kidney were predominantly diploid(88~93%), those from carcinogen-treated rats had an abnormal DNA-content peak(aneuploidy, 6-7%), near the tetraploidy area. These results suggest that diploidy may be an effective screening marker of the liver carcinogenesis. Aneuploidy may be an useful marker in assessment of the experimental renal carcinogenesis.

  • PDF

Prediction of Cavitation Intensity in Pumps Based on Propagation Analysis of Bubble Collapse Pressure Using Multi-Point Vibration Acceleration Method

  • Fukaya, Masashi;Ono, Shigeyoshi;Udo, Ryujiro
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.2
    • /
    • pp.165-171
    • /
    • 2009
  • We developed a 'multi-point vibration acceleration method' for accurately predicting the cavitation intensity in pumps. Pressure wave generated by cavitation bubble collapse propagates and causes pump vibration. We measured vibration accelerations at several points on a casing, suction and discharge pipes of centrifugal and mixed-flow pumps. The measured vibration accelerations scattered because the pressure wave damped differently between the bubble collapse location and each sensor. In a conventional method, experimental constants are proposed without evaluating pressure propagation paths, then, the scattered vibration accelerations cause the inaccurate cavitation intensity. In our method, we formulated damping rate, transmittance of the pressure wave, and energy conversion from the pressure wave to the vibration along assumed pressure propagation paths. In the formulation, we theoretically defined a 'pressure propagation coefficient,' which is a correlation coefficient between the vibration acceleration and the bubble collapse pressure. With the pressure propagation coefficient, we can predict the cavitation intensity without experimental constants as proposed in a conventional method. The prediction accuracy of cavitation intensity is improved based on a statistical analysis of the multi-point vibration accelerations. The predicted cavitation intensity was verified with the plastic deformation rate of an aluminum sheet in the cavitation erosion area of the impeller blade. The cavitation intensities were proportional to the measured plastic deformation rates for three kinds of pumps. This suggests that our method is effective for estimating the cavitation intensity in pumps. We can make a cavitation intensity map by conducting this method and varying the flow rate and the net positive suction head (NPSH). The map is useful for avoiding the operating conditions having high risk of cavitation erosion.

Effect of Pollutant Loading and Flow Distance to Wastewater Treatment Efficiency in the Constructed Wetland System (오염부하량 및 유하거리가 인공습지에 의한 폐수처리 효율에 미치는 영향)

  • 김형중;김선주;윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.5
    • /
    • pp.97-108
    • /
    • 1997
  • Natural wastewater treatment systems using the constructed wetland system were evaluated for the wastewater from the industrial complex in rural areas. For the treatment of wastewater from the industrial complex in rural area, a pilot plant of the constructed wetland system was installed at Baeksuk agri-industrial complex in ChunahnCity, Chunchungnam-Do. The experiment with this pilot plants was performed for 1996 and 1997. Results of the study were summarized as follows. For the BOD and COD, when the pollutant loading of them was about 1 3.8g/$m^2$. day (the concentration was l24.0mg/${\ell}$) arid 24.4g/$m^2$.day(the concentration was 220.Omg/${\ell}$), the removal rate of them was high, 90.2% and 93.4%, respectively. For the SS, the effluent concentration was consistently lower than the water quality standard even though the influent concentration varied significantly, which showed that SS was removed by the system effectively which consist of soil and plants. For the T-N and T-P, when the influent pollutant loading of them were moderately high, 2.8g/$m^2$.day to 7.4g/$m^2$. day(concentration 25.0mg/${\ell}$ to 49.7mg/${\ell}$) for T-N and 1.0g/$m^2$.day to 2.6g /$m^2$.day(concentration 8.6mg/${\ell}$ to 14.7mg/${\ell}$) for T-P, the removal rate of them were 86.5% and 94.0%, respectively. The removal rate by the flow distance increased rapidly in the first 4m from the inlet zone, and gradually there after. The width of system was 2m. Overall, the result showed that constructed wetland system is a feasible alternative for the treatment of wastewater from industrial complex in rural areas. Compared to existing systems, this system is quite competitive because it requires low capital cost, almost no energy and maintenance, and therefore, very cost effective.

  • PDF

Difference of tension on mooring line by buoy type (부이 형상에 따른 부이줄 장력의 차이)

  • Lee, Gun-Ho;Kim, In-Ok;Cha, Bong-Jin;Jung, Seong-Jae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.3
    • /
    • pp.233-243
    • /
    • 2014
  • The difference of mooring tension by type of buoy was investigated in the circulating water channel and the wave tank for deducting the most stable buoy from the current and the wave condition. 5 types of buoy made up of short cylinder laid vertically (CL-V), short cylinder laid horizontally (CL-H), capsule (CS), sphere (SP) and long cylinder (CL-L) were used for experiments. A mooring line and a weight were connected with each buoy. A tensile gauge was installed between a mooring line and a weight. All buoy's mooring tension was measured at the same time for the wave test with periods of 1.5~3.0 sec and wave heights of 0.1~0.3 m, and the current test with flow speeds of 0.2~1.0 m/sec. As a result, the order of tension value in the wave test was CL-H > CL-V > SP > CS > CL-L. In the current test CL-V and CL-H were recorded in the largest tension value, whereas SP has the smallest tension value. So it seems that SP buoy is the most effective in the location affected by fast current. CS is predicted to be suitable for a location that influence of wave is important more than that of current if practical use in the field is considered. And it was found that the difference of mooring tension among buoys in wave is related to the product of the cross sectional area and the drag coefficient for the buoy's bottom side in high wave height. The factor for the current condition was not found. But it was supposed to be related to complex factors like a dimension and a shape by buoy's posture to flow.