• Title/Summary/Keyword: Effective Flow Area

Search Result 468, Processing Time 0.025 seconds

Valve Seat Design for Full Contact Effect Using Grey Relational Analysis (회색 관계 분석법을 이용한 누수 방지용 밸브 시트 설계)

  • Lee, Jung-Hee;Kang, Gyeong-Ah;Kwak, Jae-Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.17-22
    • /
    • 2018
  • A glove valve regulates the flow in a pipeline as a kind of control valve. However, when the disc and seat contact, the valve structure can be distorted and flow can leak due to the elongation of the valve material under high pressure. The surface texture is not good enough to seal the contact surface (in practice) because the lapping process is usually done manually. Furthermore, assembly performance is analyzed by structural analysis. Compared with a standard seat, the newly designed seat had a smaller radial deformation and a larger longitudinal deformation. Therefore, the newly designed seat can maintain a tight and uniform contact with the disc with a reduced radial deformation and an expanded available seal area with an increased longitudinal deformation. The seal performance of the glove valve has been improved in a cost-effective manner.

Comparative Study on the Runoff Process of Granite Drainage Basins in Korea and Mongolia

  • Tanaka, Yukiya;Matsukura, Yukinori
    • The Korean Journal of Quaternary Research
    • /
    • v.17 no.2
    • /
    • pp.79-84
    • /
    • 2003
  • This study revealed the differences in runoff processes of granite drainage basins in Korea and Mongolia by hydrological measurements in the field. The experimental drainage basins are chosen in Korea (K-basin) and Mongolia (M-basin). Occurrence of intermittent flow in K-basin possibly implies that very quick discharge dominates. The very high runoff coefficient implies that most of effective rainfall quickly discharge by throughflow or pipeflow. The Hortonian overlandflow is thought to almost not occur because of high infiltration capacity originated by coarse grain sized soils of K- basin. Very little baseflow and high runoff coefficient also suggest that rainfall almost does not infiltrate into bedrocks in K-basin. Flood runoff coefficient in M-basin shows less than 1 %. This means that most of rainfall infiltrates or evaporates in M-basin. Runoff characteristics of constant and gradually increasing discharge imply that most of rainfall infiltrates into joint planes of bedrock and flow out from spring very slowly. The hydrograph peaks are sharp and their recession limbs steep. Very short time flood with less than 1-hour lag time in M-basin means that overland flow occurs only associating with rainfall intensity of more than 10 mm/hr. When peak lag time shows less than 1 hour for the size of drainage area of 1 to 10 km2, Hortonian overland flow causes peak discharge (Jones, 1997). The results of electric conductivity suggest that residence time in soils or weathered mantles of M-basin is longer than that of K-basin. Qucik discharge caused by throughflow and pipeflow occurs dominantly in K-basin, whereas baseflow more dominantly occur than quick discharge in M-basin. Quick discharge caused by Hortonian overlandflow only associating with rainfall intensity of more than 10 mm/hr in M-basin.

  • PDF

Optimization of air scouring for an effective control of membrane fouling in submerged MBR (침지형 MBR 공정의 공기 세정 최적화를 통한 효율적 막 오염 제어)

  • Kim, Jun-Young;Baek, Byung-Do;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.645-652
    • /
    • 2016
  • A membrane module including grid was designed and introduced to MBR (membrane bio-reactor) for the purpose of better control of membrane fouling. It could be anticipated that the grid enhances the shear force of fluid-air mixture into the membrane surface by even-distributing the fluid-air to the membrane module. As MLSS concentration, packing density which is expressed in the ratio of the housing and the cross-sectional area of membrane fibers ($A_m/A_t$) and air-flow rate were changed, membrane foulings were checked by monitoring fouling resistances. The total fouling resistance ($R_c+R_f$) without grid installation (i.e., control) was $2.13{\times}10^{12}m^{-1}$, whereas it was reduced to $1.69{\times}10^{12}m^{-1}$ after the grid was installed. Regardless of the grid installation, the $R_c+R_f$ increased as the packing density increased from 0.09 to 0.28, however, the increment of resistance for the grid installation was less than that of the control. Increase in the air flow rate did not always guarantee the reduction of fouling resistance, indicating that the higher air flow rate can partially de-flocculate the activated sludge flocs, which led to severer membrane fouling. Consequently, installation of grids inside the housing have brought a beneficial effect on membrane fouling and optimum air flow rate is important to keep the membrane lowering fouling.

Investigation of flow-regime characteristics in a sloshing pool with mixed-size solid particles

  • Cheng, Songbai;Jin, Wenhui;Qin, Yitong;Zeng, Xiangchu;Wen, Junlang
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.925-936
    • /
    • 2020
  • To ascertain the characteristics of pool sloshing behavior that might be encountered during a core disruptive accident of sodium-cooled fast reactors, in our earlier work several series of experiments were conducted under various scenarios including the condition with mono-sized solid particles. It is found that under the particle-bed condition, three typical flow regimes (namely the bubble-impulsion dominant regime, the transitional regime and the bed-inertia dominant regime) could be identified and a flow-regime model (base model) has been even successfully established to estimate the regime transition. In this study, aimed to further understand this behavior at more realistic particle-bed conditions, a series of simulated experiments is newly carried out using mixed-size particles. Through analyses, it is verified that for present scenario, by applying the area mean diameter, our previously-developed base model can provide the most appropriate predictive results among the various effective diameters. To predict the regime transition with a form of extension scheme, a correction factor which is based on the volume-mean diameter and the degree of convergence in particle-size distribution is suggested and validated. The conducted analyses in this work also indicate that under certain conditions, the potential separation between different particle components might exist during the sloshing process.

Vibrational energy flow in steel box girders: Dominant modes and components, and effective vibration reduction measures

  • Derui Kong;Xun Zhang;Cong Li;Keer Cui
    • Steel and Composite Structures
    • /
    • v.50 no.3
    • /
    • pp.347-362
    • /
    • 2024
  • Controlling vibrations and noise in steel box girders is important for reducing noise pollution and avoiding discomfort to residents of dwellings along bridges. The fundamental approach to solving this problem involves first identifying the main path of transmission of the vibration energy and then cutting it off by using targeted measures. However, this requires an investigation of the characteristics of flow of vibration energy in the steel box girder, whereas most studies in the area have focused on analyzing its single-point frequency response and overall vibrations. To solve this problem, this study examines the transmission of vibrations through the segments of a steel box girder when it is subjected to harmonic loads through structural intensity analysis based on standard finite element software and a post-processing code created by the authors. We identified several frequencies that dominated the vibrations of the steel box girder as well as the factors that influenced their emergence. We also assessed the contributions of a variety of vibrational waves to power flow, and the results showed that bending waves were dominant in the top plate and in-plane waves in the vertical plate of the girder. Finally, we analyzed the effects of commonly used stiffened structures and steel-concrete composite structures on the flow of vibration energy in the girder, and verified their positive impacts on energy regionalization. In addition to providing an efficient tool for the relevant analyses, the work here informs research on optimizing steel box girders to reduce vibrations and noise in them.

Analysis of Nocturnal Cold Air Flow Characteristics for Setting of Tropical Night Response Zone in Daegu (대구시 열대야 대응 구역 설정을 위한 야간 찬공기 유동성 분석)

  • SEO, Bo-Yong;LEE, Sang-Beom;GWON, Soon-Beom;CHA, Jae-Gyu;JUNG, Eung-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.3
    • /
    • pp.220-235
    • /
    • 2020
  • Heat wave generation in cities is basically affected by global warming, but it is further exacerbated by the impact of artificial heat emission and heat accumulation in the city. In particular, the effects of urban heat waves directly affect the occurrence of tropical nights. Basically, however, the choice of countermeasures against tropical nights is very limited compared to the daytime heat wave response. The purpose of this study was to analyze the characteristics of cold air flow at night as a countermeasure against tropical nights in Daegu Metropolitan City and to suggest its spatial applicability. As a research method, the spatial characteristics (flow velocity, flow rate, flow direction and range) of cold air flow in Daegu were quantitatively analyzed using KLAM_21, a cold air flow analysis program. As a result of the analysis, it was found that cold air generation and flow in the surrounding mountains of Daegu Metropolitan City was very active, but the inflow was limited to the urban area, which has tropical nights. However, it has been shown that the flow of cold air flowing from the surrounding mountains is very active in some urban areas, so it has spatial conditions that are very effective in countering tropical nights. If these spatial conditions are used for the urban planning, it will be very useful to develop countermeasures for tropical nights.

Characteristic Analysis and Prediction of Debris Flow-Prone Area at Daeryongsan (대룡산 토석류 특성 분석 및 위험지역 예측에 관한 연구)

  • CHOI, Young-Nam;LEE, Hyung-Ho;YOO, Nam-Jae
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.3
    • /
    • pp.48-62
    • /
    • 2018
  • In this study, landslide of debris flow occurred at 51 sites around Daeryounsan located in between Chuncheon-si and Hongcheon-gun during July in 2013 were investigated in field and behavior characteristics of debris flow were analyzed on the basis of records of rainfall and site investigation. According to debris flow types of channelized and hill slope, location and slope angle of initiation and deposit zone, and width and depth of erosion were investigated along entire runout of debris flow. DEM(Digital Elevation Model) of Daeryounsan was constructed with digital map of 1:5,000 scale. Land slide hazard was estimated using SINMAP(Stability INdex MAPping) and the predicted results were compared with field sites where debris flow occurred. As analyzed results, for hill slope type of debris flow, predicted sites were quite comparable to actual sites. On the other hand, for channelized type of debris flow, debris flow occurrence sites were predicted by using stability index associated with topographic wetness index. As analyzed results of 4 different conditions with the parameter T/R, Hydraulic transmissivity/Effective recharge rate, proposed by NRCS (Natual Resources Conservation Service), predicted results showed more or less different actual sites and the degree of hazard tended to increase with decrease of T/R value.

Improvement in the Simulation of Wind Fields Over the Complex Coastal Area, Korea (한반도 복잡 해안지역의 바람장 모의 개선)

  • Kim, Yoo-Keun;Bae, Joo-Hyun;Jeong, Ju-Hee;Kweon, Ji-Hye;Seo, Jang-Won;Kim, Yong-Sang
    • Journal of Environmental Science International
    • /
    • v.15 no.5
    • /
    • pp.417-430
    • /
    • 2006
  • We focused on improvement in simulation of wind fields for the complex coastal area. Local Analysis and Prediction System(LAPS) was used as a data assimilation method to improve initial conditions. Case studies of different LAPS inputs were performed to compare improvement of wind fields. Five cases have been employed : I) non data assimilation, II) all available data, III) AWS, buoy, QuikSCAT, IV) AWS, buoy, wind profiler, V) AWS, buoy, AMEDAS. Data assimilation can supplement insufficiency of the mesoscale model which does not represent detailed terrain effect and small scale atmospheric flow fields. Result assimilated all available data showed a good agreement to the observations rather than other cases and estimated veil the local meteorological characteristics including sea breeze and up-slope winds. Result using wind profiler data was the next best thing. This implies that data assimilation with many high-resolution sounding data could contribute to the improvements of good initial condition in the complex coastal area. As a result, these indicated that effective data assimilation process and application of the selective LAPS inputs played an important role in simulating wind fields accurately in a complex area.

Evaluation of the Impact of Abandoned Channel Restoration on Zaco platypus habitat using the Physical Habitat Simulation: A Case Study of the Cheongmi-cheon Stream in Korea (물리서식처 모의를 이용한 구하도 복원이 피라미의 서식처에 미치는 영향 평가: 청미천 연구 사례)

  • Kim, Seung Ki;Choi, Sung-Uk
    • Ecology and Resilient Infrastructure
    • /
    • v.6 no.2
    • /
    • pp.101-108
    • /
    • 2019
  • This study investigated the impact of abandoned channel restoration on fish habitat using the physical habitat simulation. The study area is a 1.2 km long reach of the Cheongmi-cheon stream. In the study area, the restoration of the abandoned channel was carried out from July 2012 to December 2105. Physical habitat simulations were carried out for both cases before and after the restoration. The River2D model and habitat suitability curve were used for hydraulic and habitat simulations, respectively. Zacco platypus, which is a dominant fish species in the study area, was selected as target fish for the physical habitat simulation. Hydraulic simulations were carried out before and after restoration for various discharges. Then, composite suitability index and weighted usable area were calculated before and after restoration and changes in the physical habitat of Zacco platypus were discussed. Simulation results indicated that the abandoned channel restoration is effective in creating fish habitat and mitigating the degradation of fish habitat from the high flow condition.

Ozone Production Characteristics of the DBD Discharge the Electrode Shape at the Same Electrode surface area (동일한 전극 표면적에서 DBD방전형 내부전극 형상에 따른 오존생성특성 연구)

  • Kwon, Young-Hak;Park, Hyunmi;Song, HyunGig;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.71-77
    • /
    • 2016
  • The dielectric barrier discharge (DBD) has low efficiency due to about 70% input power is consumed as thermal energy in the discharge space. However, because of the usage of DBD ozone generator is easier than other methods. The DBD ozone generator has been widely applied for high concentration ozone generation in the industrial application. But, the low-capacity compact DBD ozone generator is not applied so far. Therefore, the DBD ozone generator is necessary to improve ozone production efficiency and reduce the capacity. In this paper, the stainless steel pipe inner electrode was designed with hall type and screw type to improve the ozone production yield. The manufactured two inner electrodes were experimented with normal type for comparison of the discharge characteristics and the ozone generating characteristics. As the experimental results, the discharge current effective value of designed inner electrodes with hall type and screw type are higher than the normal type, due to unequal electric field is formed at the boundary. However, the difference of designed and original electrodes is less than 0.1mA that has no effect on the discharge characteristic. On the other hand, the screw type inner electrode increased higher than original model about 7 times when the flow rate of the oxygen source gas was increased from $0.6{\ell}/min$ to $1.0{\ell}/min$ The reason was assumed by the flow rate of the raw gas through the inner electrode was became fast that has a cooling effect. The designed hall type and screw type inner electrodes have shown good performances in ozone generation and ozone production that better than normal type in the same electrode surface area.