• 제목/요약/키워드: Effective Flow Area

Search Result 468, Processing Time 0.023 seconds

Simulating Daily Inflow and Release Rates for Irrigation Reservoirs(II) -Modeling Reservoir Release Rates- (관개용 저수지의 일별 유입량과 방류량의 모의 발생(II) -저수지 통관 방류량의 추정-)

  • 김현영;박승우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.30 no.2
    • /
    • pp.95-104
    • /
    • 1988
  • This study refers to the development of a hydrologic model simulating daily inflow and release rates for inigation reservoirs. A daily - based model is needed for adequate operation of an irrigation reservoir sufficing the water demand for paddy fields which is closely related to meteorological conditions. And the objective of this study is to develop a reservoir release rate model and then to calibrata the parameters. The release rates model considers daily water demands , water supply for transplanting, minmum release for maintaining canal flow, and maxirnun and regular flooding depth for determining effective rainfall on paddy fields. Each of the factors in the model was regarded as a lumped pararuter representing the average condition of a whole irrigated area. The water demand was estimated form the potential evapotranspiration by Penman method, the effective rainfall, and the infiltration on paddy fields. The release model was found to be capable of adequately simulating daily reservoir releases based on meteorological data.

  • PDF

Characterization of Stitched Multiaxial Warp Knit Fabric Composites and Channel Beam Manufacturing (Stitched 다축경편 복합재료의 기계적 특성 및 U 빔 성형)

  • 변준형;이상관;엄문광;김태원;배성우;하동호
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.280-283
    • /
    • 2002
  • In the manufacturing of large scale composite structures, the cost-effective processing and the enhancement of structural performance are critical. One of the most effective ways for this purpose is to use stitched multiaxial warp knitted (MWK) perform in the resin transfer molding process. This study reports the effect of stitching on the mechanical properties of MWK composites, and the feasibility processing of the thick U-beam structure utilizing the stitched preforms. Permeability of the preform, viscosity and cure property of the epoxy resin have been measured. The results of resin flow analysis has been used in determining the gate/vent locations of the RTM mold. Cross-sectional observation of the channel beam prototype demonstrated that the resin impregnation was almost complete, except for some surrounding area of stitched yarns.

  • PDF

Removal Characterics of $SO_x$ by CuO Impregnated ${\gamma}-Alumina$ (${\gamma}-Alumina$에 담지된 산화구리에 의한 $SO_x$가스의 제거 특성)

  • 이창선;윤용수
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.3
    • /
    • pp.29-35
    • /
    • 1996
  • Numerical solutions were obtained to the model equations for various parameters characterizing the pore structure, effective internal diffusion and the chemical reaction constant. The conversion was decreased with the cause of pore closure at the surface of reacting particles, reduction of porosity, surface area of reaction and effective diffusion coefficient in the solid with the progress of reaction. Total conversion was strongly depend on the local conversion at surface. According to the decreasing of impregnated concentration of the copper oxide and the increase of the flue gases concentration, total conversion was increased. And the conversion were affected by gas flow rate and pore size distribution of the reacting solid.

  • PDF

Analysis on ventilation efficiency by CFD simulation for breathing zone in bed room (CFD해석에 의한 침실 호흡역의 환기효율 분석)

  • Yoo, Bok-Hee;Yoon, Chung-Sook
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.11-16
    • /
    • 2002
  • Indoor air environment is one of the most important factors that affect resident's health and comfort level. In this paper, the influence of ventilation efficiency with different types of furniture arrangement at breathing zone in a room was analyzed by numerical simulation based on computational fluid dynamics(CFD). The furniture layout of students' bedroom have been classified by three different patterns so that SVE3(scale for ventilation efficiency3) in the rooms was analyzed for air flow distribution. According to the results of the study, SVE3 has the maximum value in spaces between furnitures and each comer of the room. The furniture arrangement influences the ventilation efficiency. It was con finned that ventilation effective in a room is not uniformly distributed as compared the breathing zone with all the area in a room. It means that a study of ventilation efficiency was considered relatively with target zone(a residential or breathing zone) and all the area in a space.

Aortic Valve Replacement with Patch Enlargement of Aortic Annulus in Aortic Stenosis with small aortic Annulus. (소 대동맥 판막륜을 가진 대동맥판막 협착증 치험 1례 보고)

  • 권오춘
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.663-666
    • /
    • 1985
  • Whatever a surgeon choose aortic prosthesis in aortic stenosis, it will always provoke some degree of obstruction to flow due to its smaller effective orifice area to tissue annulus. Occasionally, we meet small aortic annulus to his or her body surface area in aortic valve replacement. The small annulus remains a problem in that both tissue and mechanical prosthesis have significant pressure gradients between LV and aorta in resting or exercising states. In these circumstances, diverse surgical procedures, such as tilting disc prosthesis, supraannular position of aortic prosthesis, and enlargement of aortic root [including aortoventriculoplasty, translocation of aortic valve, & double outlet of LV by valved conduit], were applied. We experienced one case of aortic stenosis with small aortic annulus. Systolic pressure gradients between LV & aorta were 90 mmHg. Diameter of annulus was 19 mm. So we performed patch enlargement of aortic root by Manouguian and AVR with St. Jude medical valve 23 mm.

  • PDF

Numerical simulation for dispersion of anthropogenic material near shellfish growing area in Geoje Bay (거제만 패류양식 해역에서의 육상기인 물질 확산에 관한 수치실험)

  • KIM, Jin-Ho;LEE, Won-Chan;HONG, Sok-Jin;KIM, Dong-Myung;CHANG, Yong-Hyun;JUNG, Woo-Sung
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.3
    • /
    • pp.831-840
    • /
    • 2016
  • Hydrodynamic condition can be used to predict particle movement within water column and the results used to optimize environmental conditions for effective site selection, setting of environmental quality standard, waste dispersion, and pathogen transfer. To predict the extent of movement of particle from land, 3D hydrodynamic model that includes particle tracking module was applied to Geoje Bay and to calibrate particle tracking model, floating buoy measurement is operated. The model results show that short time is required for particles released into system from river to be transported to the shellfish farming area. It takes about 2 days for the particles to shellfish farming area under mean flow condition. It meant Geoje Bay, especially shellfish farming area is vulnerable to anthropogenic waste from river.

A Study on Kitchen Use Behaviors through User Observation - Focused on Small-sized Apartments in Shanghai, China - (사용자 관찰을 통한 부엌 사용 행태 연구 - 중국 상해 소형아파트를 중심으로 -)

  • Kim, Myoung;Choi, Kyung-Ran
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.3
    • /
    • pp.121-128
    • /
    • 2015
  • As a neighboring country belonged to the same cultural sphere with the Northeast Asia, China is recently emerging as a center of the world's economy. The social transformations caused by the rapid economic growth are bringing changes in the Chinese housing culture and thus, it is considered that the identification of a user's need concerning a new housing space and social and cultural understanding on China are necessary. Accordingly, this research intended to conduct the basic research on the Chinese housing space design by observing the small apartment users in Shanghai area in terms of not only the tangible element of the residential space type but also the intangible elements such as lifestyle, values, behaviors, etc. The research range was limited to the kitchen area at the center of a house as a place where the exchanges among the family members are most frequently occur, and the research was carried out in the following methods. First, the effective user research method for the analysis of the Chinese small apartment kitchen users was studied through the literature investigation. Second, the 6 families of a research target were selected focused on the small apartments in Shanghai, China and the user research was performed using three methods of User observation, Video ethnography, and Contextual inquiry. Third, the research results were analyzed focused on the flow of human traffic in the kitchen area and user's behaviors. What were identified as a result take account of the human traffic movements in the kitchen areas around the sink-counter-cook top, cooking behaviors and meal areas outside of the kitchen. Through this, the need for the effective organization of the sink-counter-cook top, arrangement of meal area, and placement of storage by section for the kitchen space of China were drawn based on the understanding of the cooking process, and it was identified that such results require comprehensive understanding of Chinese housing culture.

A Study on the Condensation Heat Transfer and Pressure Drop in Internally Grooved Tubes Used in Condenser (응축기용 낮은 핀관의 내부 나선 홈에 의한 응축 열전달 성능과 압력손실에 관한 연구)

  • Han, Kyuil;Cho, Dong-Hyun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.2
    • /
    • pp.212-222
    • /
    • 1998
  • Heat transfer performance improvement by fin and groovs is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapczodially shaped integral-fins having fin density from 748 to 1654fpm(fin per meter) and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also used for comparison. R-11 condensates at saturation state of 32 $^{\circ}C$ on the outside tube surface coded by inside water flow. All of test data are taken at steady state. The heat transfer loop is used for testing singe long tubes and cooling is pumped from a storage tank through filters and folwmeters to the horizontal test section where it is heated by steam condensing on the outside of the tubes. The pressure drop across the test section is measured by menas pressure gauge and manometer. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, overall heat transfer coefficients of finned tube are enhanced up to 1.6 ~ 3.7 times that of a plain tube at a constant Reynolds number. 2. Friction factors are up to 1.6 ~ 2.1 times those of plain tubes. 3. The constant pumping power ratio for the low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio. 4. A tube having a fin density of 1299fpm and 30 grooves has the best heat transfer performance.

  • PDF

Determination of an Underground Seawater Flow Using a TEM Decay Curve (TEM감쇠곡선을 이용한 해수의 지하 유동현상 파악)

  • 황학수;문창규;이상규;이태섭
    • Economic and Environmental Geology
    • /
    • v.34 no.5
    • /
    • pp.499-506
    • /
    • 2001
  • The geophysical monitoring technique using the high resolution time-domain electromagnetic (TEM) method with a coincident loop away was applied for determination of an underground seawater flow in the coastal areas. In comparison of the TEM monitoring to direct current (DC) resistivity monitoring, the TEM response to the under ground seawater flow is less sensitive than the DC resistivity response. However, the TEM monitoring is more effective in terms of measuring time, survey expense, and real-time data processing than the DC monitoring thor evaluating the spatial distribution of the fresh water-seawater transition zone in a regional area.

  • PDF

Inflow Nozzle Conditions for Improving Vortex Tube Performance (보텍스튜브 성능향상을 위한 유입노즐 조건에 관한 연구)

  • Choi, Hoon-Ki;Yoo, Geun-Jong;Lim, Yun-Seung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.2
    • /
    • pp.68-76
    • /
    • 2018
  • A vortex tube is a simple energy separating device that splits a compressed air stream into a cold and hot stream without any external energy supply or chemical reactions. The efforts of many researchers and designers have been focused on improvement of vortex tube efficiency by changing the parameters affecting vortex tube operation. The effective parameters are nozzle specifications and inflow pressure conditions. Effects of different nozzle cross-sectional area and number of nozzles are evaluated by computational fluid dynamics (CFD) analysis. In this study, CFD analysis of 3-D steady state and turbulent flow through a vortex tube was performed. We investigated the cold air mass flow rate, the cold air temperature, and the cold air heat transfer rate behavior of a vortex tube by utilizing seven straight nozzles and four inflow pressure conditions.