• Title/Summary/Keyword: Effect-Site Concentration

Search Result 356, Processing Time 0.026 seconds

Effect on N Defect in Cu-doped III-nitride Semiconductors

  • Kang, Byung-Sub;Lee, Jae-Kwang;Lim, Yong-Sik;Song, Kie-Moon;Chae, Kwang-Pyo
    • Journal of Magnetics
    • /
    • 제16권4호
    • /
    • pp.332-336
    • /
    • 2011
  • We studied the effect on the electronic and magnetic properties of the N defect in clean and Cu-doped wurtzite III-nitrides by using the first-principles calculations. When it is doped two Cu atoms in the nearest neighboring sites, the system of AlN, GaN, or InN with the N vacancy is energetically more favorable than that without the N vacancy site. When the Cu concentration increases, the total magnetic moment of a supercell becomes small. The ferromagnetism of Cu atom is very low due to the weak 3d-3d coupling. It is noticeable that the spin-exchange interaction between the Cu-3d and N defect states is important.

태안군 신두리 해안사구의 식생과 토양특성 (Vegetation and Soil Properties of the Coastal Sand Dune in Sinduri, Taean Gun)

  • 송호경;박관수;박혜림;서은경;소순구;김무열
    • 한국환경복원기술학회지
    • /
    • 제8권6호
    • /
    • pp.59-68
    • /
    • 2005
  • This study was carried out to investigate soil properties, ordination, and vegetation of the coastal sand dune in Sinduri, Taean-Gun. 1. The Orobanche coerulescens and Ixeris repens that are a peculiar species were found in Sinduri coastal sand dune and the Salix purpurea var. japonica that is an endemic species of korea was found in that place. The plant communities was categorized into seven groups, such as Rosa rugosa community, Vitex rotundifolia communit, Carex kobomugi community, Imperata cylndrica var. koenigii community, Carex pumila community, Artemisia capillaris community, and Calamagrostis epigeios community. 2. The soil organic matter, total nitrogen, available phosphorous concentrations, and cation exchange capacity were lower in the study sites than in forest soil of seashore. There was little difference in soil exchangeable Ca, Mg, and K concentrations between in the study site and in the forest soil of seashore. The soil pH was ranged from 5.69 to 7.63. The soil texture in the study site was sand or loamy sand. 3. The results of the correlation between Sinduri coastal sand dune community and environmental factor are as follows; the soil pH was the most effect to the community distribution, and CEC, total nitrogen, soil organic matter, and the amount of silt in soil have some correlation with community distribution. 4. The results of the correlation between Sinduri coastal sand dune community and soil characteristics are as follows; the Calamagrostis epigeios community was found in area that have high soil moisture content; the Rosa rugosa community was found in area that have high soil CEC, organic matter concentration, and total nitrogen concentration, and low soil pH; the Vitex rotundifolia community, Carex kobomugi community, and Artemisia capillaris community were found in area that have low soil CEC, organic matter concentration, and total nitrogen concentration, and high soil pH; the Imperata cylndrica var. koenigii community and Carex pumila community were found in area that have medium soil CEC, organic matter concentration, total nitrogen concentration, and soil pH.

황련 유래 Antimicrobial Peptide의 Candida albicans 감염 억제효과 (Effect of Antimicrobial Peptide from Coptidis Rhizoma on Candida albicans Infection)

  • 이주희
    • 약학회지
    • /
    • 제55권3호
    • /
    • pp.227-233
    • /
    • 2011
  • We previously reported the protein isolated from Coptidis Rhizoma (CRP), which has antifungal activity against a fungal pathogen, Candida albicans. In the current study, we investigated what portion in the CRP is responsible for the antifungal activity. For the investigation, the CRP was fractionated on a Shepadex G-50 column. Data resulting from the fractionation, seven fractions were obtained. Fractions (Fr.) I, II, and III eluted initially from the column showed no inhibitory effect on the growth of C. albicans, whereas Fr. IV, V, and VI eluted later revealed inhibition of the growth, and Fr. IV and VI showed potent antifungal activity by broth susceptibility analysis. However, Fr. VI was contained in the CRP more than Fr. IV, which led us to select the VI for the following experiments. In a murine model of a subcutaneous candidiasis caused by C. albicans, the Fr. VI displayed a therapeutic effect on nude mice pretreated with anti-neutrophil monoclonal antibody (RB68C5) and then infected subcutaneously with live C. albicans. At day 16, these mice were healed almost up to 78% of the infected area when compared to infected area of control nude mice that received diluent (Dulbecco's Phosphate-Buffered Saline; DPBS), instead of the Fr. VI (P<0.01). The Fr. VI blocked hyphal formation from blastoconidial form of C. albicans (P<0.01), which might prevent penetration of hyphae to the deeper site of skin and thus helps the healing. In the ionic strength test, the effect of Fr. was influenced by $Ca^{2+}$ ion just like other known antimicrobial peptides, but the influence was affected at an extremely high concentration such as 500 mM. Thus, such ion-concentration is considered to be meaningless in the clinical situation. Considering all data together, Coptidis Rhizoma is appeared to produce an antimicrobial peptide that has therapeutic effect on subcutaneous infection caused by C. albicans.

ICT 확산과 성형외과의 강남구 집중화 현상사이의 종단적 연관성 분석-웹 속성을 중심으로 (A longitudinal association analysis between the diffusion of ICT and the spatial concentration of plastic surgery clinics in Gangnam-Gu)

  • 조영빈;이석기
    • 디지털융복합연구
    • /
    • 제12권11호
    • /
    • pp.123-131
    • /
    • 2014
  • ICT의 확산과 함께 물리적 공간에서의 집중화 현상이 일어났는데 바로 성형외과 의원의 강남구 집중이다. 본 연구는 ICT의 확산과 물리적 공간에서의 집중화가 연관성이 있는지 알아보기 위하여 강남구의 성형외과 의원 집중화에 초점을 맞추어 종단적으로 검증했다. 이를 위하여 2006년부터 2011년까지 5년 동안 총 401개 샘풀을 조사하였다. 강남구 성형외과 의원의 웹 사이트와 타 지역 성형외과 의원의 웹 사이트의 동질성을 비교하였다. 분석방법으로는 다변량 판별분석을 사용하였다. 분석결과, 강남구의 성형외과 웹 사이트는 5년 동안 타 지역과 유의하게 같지 않았다. 그러므로 ICT의 확산과 성형외과의 지역적 집중화는 서로 연관성이 있다고 결론지을 수 있었다.

AZ31 Mg합금의 PEO피막 형성거동에 미치는 인산나트륨 농도의 영향 (Effect of Na3PO4 Concentration on The Formation Behavior of PEO films on AZ31 Mg Alloy)

  • 문성모;김주석
    • 한국표면공학회지
    • /
    • 제52권5호
    • /
    • pp.265-274
    • /
    • 2019
  • Formation behavior of PEO (Plasma Electrolytic Oxidation) films on AZ31 Mg alloy was investigated under application of 310 Hz AC as a function of $Na_3PO_4$ concentration from 0.02 M to 0.2 M. Film formation voltage and in-situ observation of arcs generated on the specimen surface were recorded with time, and surface morphologies of the PEO films were investigated using optical microscopy, confocal scanning laser microscopy and scanning electron microscopy. PEO film formation voltage decreased linearly with increasing $Na_3PO_4$ concentration which is attributed to the increase of solution pH. PEO films were grown uniformly over the entire surface in $Na_3PO_4$ solutions between 0.05 M and 0.1 M. However, non-uniform PEO films with white spots were formed in $Na_3PO_4$ solutions containing more than 0.1 M. Thickness and roughness of PEO films on AZ31 Mg alloy increased linearly with increasing $Na_3PO_4$ concentration and their increasing rates appeared to be much higher under 1 M than above 1 M. The experimental results suggest that phosphate ions can contribute to the formation of PEO films but higher $Na_3PO_4$ concentration more than 1 M results in local damages of PEO films due to repeated generation of white arcs at the same surface site of AZ31 Mg alloy.

Composition and Characteristics of ionic Components of Aerosols Collected at Gosan Site in Jeiu Island, Korea

  • Kang, Chang-Hee;Kim, Won-Hyung;Hu, Chul-Goo;Kim, Yong-Pyo;Shim, Shang-Gyoo;Hong, Min-Sun;Kim, Ki-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제19권E4호
    • /
    • pp.177-186
    • /
    • 2003
  • The total of 1,454 aerosol samples were collected by high volume tape sampler at the Gosan Site in Jeju Island from 1992 to 1999, and the major water-soluble ionic components were chemically analyzed. The mean concentrations of nss-S $O_4$$^{2-}$, N $H_4$$^{+}$, and N $O_3$$^{[-10]}$ showed high values, which were 6.73, 1.45, and 1.45 ${\mu}{\textrm}{m}$/㎥, respectively, while $Ca^{2+}$ and $K^{+}$ concentrations were low with the values of 0.49 and 0.42 $\mu\textrm{g}$/㎥. The concentrations of most components increased in spring but decreased in summer, especially with the remarkable increase of $Ca^{2+}$ and N $O_3$$^{[-10]}$ concentrations in spring. The seasonal comparison of nss-S $O_4$$^{2-}$ concentrations showed higher values with the order of spring > fall 〉 winter〉 summer, but spring 〉 winter〉 fall 〉 summer for N $O_3$$^{[-10]}$ Meanwhile, the concentration levels of N $a^{+}$ and C $l^{[-10]}$ increased more in winter season. According to the investigation of wind direction effect, the concentrations of most aerosol ionic components showed higher values consistently at the westerly and northerly wind conditions. Based on the factor analysis, the atmospheric aerosols in the Gosan Site are considered to be largely affected by marine sources, followed by anthropogenic and soil sources.urces..

파주생태습지의 부착규조를 이용한 생물학적 수질평가 (The biological assessment of water quality using DAIpo and TDI of Paju Ecological wetland)

  • 김용진;김헌년;이옥민
    • 환경영향평가
    • /
    • 제21권2호
    • /
    • pp.229-238
    • /
    • 2012
  • This research was to examine the physiochemical factors and the attached diatoms of ecological wetland in Paju from August 2010 to May 2011. As a result of physicohemical water quality assessment, the water temperature did not fluctuate much due to ample riparian vegetation and aquatic plants growing at the site. Due to the effect of Han River Estuary, site 4, 5 and 6 had high electricity conductivity. The BOD concentration was high at site 2, 3, and 4 caused by decrease in water quantity and inflow of polluted water. At all sites, T-N and T-P concentrations ranged from eutrophic to hypertrophic status. At the downstream, the T-N and T-P concentrations decreased by inhabiting aquatic plant. Total of 98 taxa of attached diatoms were found. As for dominant taxa, Achnanthes convergens, A. minutissima, Gomphonema gracile, G. parvulum, Melosira varians, Navicula seminulum, N. minima, N. pseudolanceolata, Nitzschia amphibia, N. palea, Surirella minuta and Synedra ulna var. fragilariodes appeared. The result of biological assessment of water quality rated the sites B(suboptimal)~D(poor) during seasons of low water temperature, Fall and Winter, with DAIpo ranging 24.1~68.2 and TDI of 48.4~85.6. During Spring and Summer, all sites were rated D(poor) with DAIpo lower than or equal to 40, and TDI above or equal to 70. The biological assessment of water quality at the research site showed inferior TDI result compared to that of DAIpo.

축산농가에서 배출되는 비점오염 물질이 소규모 유역에 미치는 영향 (Effect of NPS Loadings from Livestock on Small Watersheds)

  • 이수인;신민환;전제홍;박병기;이지민;원철희;최중대
    • 한국농공학회논문집
    • /
    • 제57권2호
    • /
    • pp.27-36
    • /
    • 2015
  • The objective of this paper was to quantitatively analyze the effect of concentrated animal feeding operations (CAFO) NPS pollution on a small watershed water quality. Monitoring was conducted from March to October, 2013. Monthly flow rate and selected water quality at each monitoring site were measured during dry days. Rainy day monitoring also was conducted. Modeling was conducted to evaluate the effect of CAFO NPS pollution on the water quality at the watershed outlet. The highest and mean concentration of selected water quality indices during rainy days were higher than those in dry days in general. The highest TN concentration measured at the CAFP pollution discharge point was 237.831 mg/L. The results revealed that the CAFO NPS pollution sources could be equally blamed for the water quality degradation of the stream. However, the effect of the NPS pollution from CAFOs seemed not to be very influential to the watershed water quality at the outlet. SWAT modeling revealed that the TN load was reduced by 18.95 %, 23.39 % and 30.53 % at the watershed outlet if the TN load at the CAFO NPS pollution discharge point reduced by 20 %, 40 % and 60 %, respectively. It was thought that the natural attenuation processes played an important role. The modeling was based only on the assumption of the load reduction and not verified by the monitored data. Therefore, it was suggested that a long term monitoring studies for the evaluation of the impact of CAFO NPS pollution on the watershed water quality be conducted.

Dual Effect of Dynorphin A on Single-Unit Spike Potentials in Rat Trigeminal Nucleus

  • Lee, Keun-Mi;Han, Hee-Seok;Jang, Jae-Hee;Ahn, Doug-Kuk;Park, Jae-Sik
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제5권3호
    • /
    • pp.213-221
    • /
    • 2001
  • The amygdala is known as a site for inducing analgesia, but its action on the trigeminal nucleus has not been known well. Little information is available on the effect of dynorphin on NMDA receptor-mediated electrophysiological events in the trigeminal nucleus. The purpose of this study was to investigate the changes in the single neuron spikes at the trigeminal nucleus caused by the amygdala and the action of dynorphin on the trigeminal nucleus. In the present study, extracellular single unit recordings were made in the dorsal horn of the medulla (trigeminal nucleus caudalis) and the effects of microiontophoretically applied compounds were examined. When [D-Ala2, N-Me-Phe4, Glys5-ol]enkephalin (DAMGO, 10-25 mM), a ${\mu}-opioid$ receptor agonist, was infused into the amygdala, the number of NMDA-evoked spikes at the trigeminal nucleus decreased. However, the application of naloxone into the trigeminal nucleus while DAMGO being infused into the amygdala increased the number of spikes. Low dose (1 mM) of dynorphin in the trigeminal nucleus produced a significant decrease in NMDA-evoked spikes of the trigeminal nucleus but the NMDA-evoked responses were facilitated by a high dose (5 mM) of dynorphin. After the ${\kappa}$ receptors were blocked with naloxone, dynorphin induced hyperalgesia. After the NMDA receptors were blocked with AP5, dynorphin induced analgesia. In conclusion, dynorphin A exerted dose-dependent dual effects (increased & decreased spike activity) on NMDA-evoked spikes in the trigeminal nucleus. The inhibitory effect of the dynorphin at a low concentration was due to the activation of ${\kappa}$ receptors and the excitatory effect at a high concentration was due to activation of NMDA receptors in the trigeminal neurons.

  • PDF

학교 숲 식재구조에 따른 음이온 발생량 비교 분석 (A Comparative Analysis of Negative Air Ions according to the Planting Structure at School Forests)

  • 김정호;오득균;박용관;윤용한
    • 한국조경학회지
    • /
    • 제43권5호
    • /
    • pp.55-64
    • /
    • 2015
  • 본 연구는 쾌적성을 증진시킬 수 있고, 인간의 건강에 긍정적인 영향을 미칠 수 있는 음이온을 평가인자로 설정하고, 학교별 녹지특성 및 배치, 기상요소를 구분하여 음이온 발생에 효과적인 학교숲 조성모델을 제시하고, 더 나아가 도시녹지 조성에 대한 기초자료로 제공하고자 하였다. 연구결과, 음이온의 경우 식재구조에 따라 차이가 있으며, 단층구조($934ea/cm^3$) > 다층구조($794ea/cm^3$) > 잔디($553ea/cm^3$) > 나지($529ea/cm^3$)의 순으로 분석되었다. 또한 기상요소와의 상관성의 경우, 기온과 부의 상관관계인 것으로 분석되었다. 분산분석 및 사후분석 결과, 식재구조의 차이에 따른 음이온발생량은 통계적으로 차이가 있는 것으로 분석되었다. 녹지구조에 따른 음이온농도의 차이는 다층구조보다 단층구조에서 더 높은 것으로 분석되었다. 이는 다층구조에서 단층구조보다 기온이 더 높게 측정되었는데, 선행연구 고찰결과, 음이온 발생원에서 일정거리 이내에서는 기온이 높을수록 음이온 농도가 낮아지기 때문인 것으로 사료되었다. 또한 풍속이 다층구조 식재구조보다 단층구조 식재구조에서 더 높게 측정되었는데, 음이온의 확산에 있어 단층구조 식재구조가 다층구조 식재구조에 비하여 수목에 의한 바람의 차폐가 상대적으로 덜 이루어져 음이온의 발생과 확산이 더 유리할 것으로 사료되었다.