• Title/Summary/Keyword: Effect study

Search Result 117,687, Processing Time 0.136 seconds

The study of growth and characterization of CuGaTe$_2$single crystal thin films by hot wall epitaxy (Hot wall epitaxy(HWE) 방법에 의한 CuGaTe$_2$단결정 박막 성장과 특성에 관한 연구)

  • 홍광준;이관교;이상열;유상하;정준우;정경아;백형원;방진주;신영진
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.10 no.6
    • /
    • pp.425-433
    • /
    • 2000
  • The stochiometric mix of evaporating materials for the $CuGaTe_2$single crystal thin films was prepared from horizontal furnance. Using extrapolation method of X-ray diffraction patterns for the $CuGaTe_2$polycrystal, it was found tetragonal structure whose lattice constant $a_0 and c_0$ were 6.025 $\AA$ and 11.931 $\AA$, respectively. To obtain the single crystal thin films, $CuGaTe_2$mixed crystal was deposited on throughly etched semi-insulator GaAs(100) substrate by the Hot Wall Epitaxy (HWE) system. The source and substrate temperature were $670^{\circ}C$ and $410^{\circ}C$ respectively, and the thickness of the single crystal thin films is 2.1$\mu\textrm{m}$. The crystalline structure of single crystal thin films was investigated by the photoluminescence and double crystal X-ray diffraction (DCXD). Hall effect on this sample was measured by the method of van der Pauw and studied on carrier density and mobility dependence on temperature. The carrier density and mobility of $CuGaTe_2$single crystal thin films deduced from Hall data are $8.72{\times}10{23}$$\textrm m^3$, $3.42{\times}10^{-2}$ $\textrm m^2$/V.s at 293K, respectively. From the photocurrent spectrum by illumination of perpendicular light on the c-axis of the $CuGaTe_2$single crystal thin film, we have found that the values of spin orbit coupling $\Delta$s.o and the crystal field splitting $\Delta$cr were 0.0791 eV and 0.2463 eV at 10 K, respectively. From the PL spectra at 10 K, the peaks corresponding to free bound excitons and D-A pair and a broad emission band due to SA is identified. The binding energy of the free excitons are determined to be 0.0470 eV and the dissipation energy of the donor-bound exciton and acceptor-bound exciton to be 0.0490 eV, 0.0558 eV, respectively.

  • PDF

An IRS Study on the Adsorption of Carbonmonoxide on Silica Supported Ni-Cu Alloys (실리카 지지 니켈-구리 합금에서 일산화탄소의 흡착에 관한 IRS 연구)

  • Ahn, Jeong-Soo;Yoon, Koo-Sik;Park, Sang-Youn;Park, Sung-Kyun
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.3
    • /
    • pp.233-243
    • /
    • 2009
  • We have investigated the infrared spectra for CO adsorbed on silica supported nickel(Ni-Si$O_2$), silica supported copper(Cu-Si$O_2$), silica supported nickel-copper alloys(Ni/Cu-Si$O_2$) of several compositions with varying CO pressures(0.2 $torr{\sim}$50 torr) at room temperature and on pumping to vacumn at room temperature within the frequency range of 1500 $cm^{-1}{\sim}2500\;cm^{-1}$. Four bands(2059.6 $cm^{-1},\;{\sim}$2036.5 $cm^{-1},\;{\sim}$ 1868.7 $cm^{-1},\;{\sim}$ 1697.1 $cm^{-1}$) were observed for Ni-Si$O_2$, two bands($\sim$2115.5 $cm^{-1},\;{\sim}$1743.0 $cm^{-1}$) were observed for Cu-Si$O_2$ and five bands(${\sim}2123.2\;cm^{-1}$, 2059.6 $cm^{-1},\;{\sim}$2036.4 $cm^{-1},\;{\sim}$1899.5 $cm^{-1},\;{\sim}$1697.1 $cm^{-1}$) were observed for Ni/Cu-Si$O_2$. These absorption bands correspond with those of the previous reports approximately. The bands below 1800 $cm^{-1}$ were only observed with Ni metal or Ni/Cu alloy crystal plane containing step at room temperature and the ${\sim}1697.1\;cm^{-1}$ bands observed with Ni-Si$O_2$ and Ni/Cu-Si$O_2$ may be ascribed to CO molecule adsorbed on the adsorption sites near step. The bands below 2000 $cm^{-1}$ were rarely observed with Cu metal crystal plane at room temperature and the 1743.0 $cm^{-1}$ bands may be ascribed to CO molecule adsorbed on the adsorption sites near step. The band shifts of adsorbed CO with varing Cu contents from 0 to 0.5 mole fraction at the same CO pressure or at the same pumping time to vacumn were below 21 $cm^{-1}$. and comparatively small than those with other ⅠB metal addition. It may means ligand effect of Cu d electron is small.

Effect of Blanching Condition, Acid and Alkali Treatments on the Qualities of Carrot Juices (Blanching 조건(條件) 및 산(酸)·알칼리 처리(處理)가 당근주우스의 품질(品質)에 미치는 영향(影響))

  • Kim, Woon Sung;Kim, Seung Yeol
    • Korean Journal of Agricultural Science
    • /
    • v.10 no.1
    • /
    • pp.135-145
    • /
    • 1983
  • This study was conducted to obtain the fundamental data for the processing of carrot juices and know the effects of blanching conditions, acid and alkali treatments and sterilization on the quality factors of carrot juices. The result obtained was as follows. 1. Blanching condition, $100^{\circ}C$, 5min. was the most effective for the Brix, amino-N content, suspended solid, light transmittance and yield of carrot juices among $90^{\circ}C$, 15min., $95^{\circ}C$, 10 min., and $100^{\circ}C$, 5min. 2. 0.05N-acetic acid solution was the most effective blanching solution for the suspended solid, light transmittance, viscosity and yield of the juices compared to 0.05N-citric acid and 0.03N-hydrochloric acid solution. 3. The color changes during the processing of carrot juices caused by blanching process rather than sterilization process. 4. The ${\beta}$-carotene in carrot juices was very stable and about 80 % of it was remained in the carrot juice which had been blanched, extracted and sterilized at $115^{\circ}C$ for 30min. 5. Alkali treatment for the juice from acid - blanched carrots formed discoloration after sterilization. 6. Relative content (%) of sugars in raw carrot juice we re ribose, 8.51%; fructose. 10.15%; glucose, 12.25%; sucrose, 49.53% and oligosaccharide, 19.56%. When the carrots were blanched in boiling water, the contents of monosaccharide and disaccharide decreased slightly but that of oligosaccharide increased slightly, however, when the carrots were blanched in acid solution, and then neutralized and sterilized, relative contents of ribose and sucrose decreased remarkably but that of oligosaccharide increased considerably and those of glucose and fructose increased slightly. 7. Nineteen sorts of free amino acid were detected from the carrot juices and the mains of them were threonine+asparagine, alanine, serine+glutamine, aspartic acid, arginine, and glutamic acid.

  • PDF

Influence of Septic in Vibrio Vulnificus from Phytic Acid (피틴산(Phytic acid)이 비브리오(Vibrio vulnificus) 패혈증에 미치는 영향)

  • Chung, Young-Ho;Cho, Chun-Hwi;Lee, Sun-Woo;Lim, Chi-Hwan
    • Korean Journal of Agricultural Science
    • /
    • v.32 no.1
    • /
    • pp.71-80
    • /
    • 2005
  • Phytic acid chelates excellently the metallic ions and the positive ions, especially has high affinity with $Fe^{2+}$ and $Ca^{2+}$. Merits of phytic acid can be taked in easily, edibile and harmless to body, so it was investigated that phytic acid can be substituted for EDTA in this study. 1. The Intensificative effect of chelating agent and disinfective osmotic shock of Vibrio vulnificus The number of initial existent fungi measured $1.7{\times}10^6$. The percentages of the survival fungi against the osmotic shock by distillated water were calculated at 1 minute, 3 minute and 5 minute after inoculation. The percentages of the survival fungi in $Mg^{2+}$ were 92.5%, 91.8% and 79.8% at each time, the average percentage was 88%. Also the sudden extinction was observed around 1 minute after inoculation and the survival fungi were not observed from 3 through 5 minute in spite of repeated experimentation. 2. Influence of Vibrio vulnificus on the survival of the mice. The first mouse started to die in 180 minute after inoculation in case that the inoculating number was $2.3{\times}10^7cfu/ml$. All died within 4.5 hour. The average of survival time was 226 minute. The first mouse started to die in 228 minute after inoculation in case that the inoculating number was $0.8{\times}10^6cfu/ml$. All died within 5 hour. The average of survival time was 300 minute and the survival time was 1.3 times high. The tendencies of death in two cases were similar, but the fatal rate were largely dependent on inoculating number.

  • PDF

The Effect of Vitamin E on the Composition of inflammatory Cells in Alveoli after Paraquat Intoxication in Rats (Paraquat에 의한 급성 폐손상에서 Vitamin E처치가 기관지폐포 세척액내 세포조성에 미치는 영향)

  • Song, Kwang-Seon;Lee, Won-Yeon;Cho, Do-Yeun;Yong, Suk-Joong;Shin, Kye-Chul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1332-1342
    • /
    • 1997
  • Background : Acute pulmonary injury by paraquat are caused by multiple mechanisms including direct injury with oxygen free radicals and several mediators released from inflammatory cells. In order to clarify whether vitamin E could reduce tissue damages induced by intraperitoneal administration of paraquat and to investigate the pathogenetic mechanisms of paraquat-induced pulmonary injury, vitamin E as a free radical scavenger was administered. Method : Rats were divided into three groups (group 1 : control, group 2 : paraquat treated group, group 3 : paraquat and vitamin E treated group). Animals were sacrificed on day 1, day 2, day 3, and day 8 after the administration of saline, paraquat, or paraquat/vitamin E. Results : Treatment with vitamin E decreased the death rate of rats treated with paraquat. Comparing with control group ($1.37{\times}10^6/ml$), mean total cell counts recovered from the lavage fluid from animals treated with paraquat($1.65{\times}10^6/ml$) were increased(p=0.06). Magnitudes of increment of the total cell counts on the Day 8 in the vitamin E treated group were smaller than those of the animals treated with paraquat alone. The neutrophils began to appear in significant amounts in the lavage fluid on Day 8 after the administration of paraquat(37.0+12.7%). A significant decreasing neutrophil concentration at Day 8 was observed in the paraquat/vitamin E treated group(20.6+13.4%). Histologically the degree of pulmonary fibrosis was most prominent in the paraquat treated group while diffuse alveolar damage was continuously observed in the paraquat/vitamin E treated group and extensive interstitial lymphocytic infiltration was seen in the paraquat/vitamin E treated group. The paraquat/vitamin E treated group showed the less histologic changes. Conclusion : In this study vitamin E acting as a scavenger of neutrophil-derived free radicals and suppressant of lipid peroxidation, seemed to be the effective antioxidant in the inhibition of paraquat-induced pulmonary injury.

  • PDF

Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments (지르코늄 임플란트 지대주의 나사결합부 안정성에 관한 연구)

  • Lee, Mi-Soon;Suh, Kyu-Won;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.164-173
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effect of abutment material on screw-loosening before and after cyclic loading. Among the different materials of abutments, zirconia and metal abutment were used. Material and methods: Two types of implant systems: external butt joint(US II, Osstem Implant, Korea) and internal conical joint(GS II, Osstem Implant, Korea) were used. In each type, specimens were divided into two different kinds of abutments: zirconia and metal(n=5). The implant was rigidly held in a special holding to device ensure fixation. Abutment was connected to 30 Ncm with digital torque gauge, and was retightened in 30 Ncm after 10 minutes. The initial removal torque values were measured. The same specimens were tightened in 30 Ncm again and held in the cycling loading simulator(Instron, USA) according to ISO/FPIS 1480. Cycling loading tests were performed at loads 10 to 250 N, for 1 million cycles, at 14 Hz,(by subjecting sinusoidal wave from 10 to 250 N at a frequency of 14 Hz for 1 million cycles,) and then postload removal torque values were evaluated. Results: 1. In all samples, the removal values of abutment screw were lower than tightening torque values(30 Ncm), but the phenomenon of the screw loosening was not observed. 2. In both of the implant systems, initial and postload removal torque of zirconia abutment were significantly higher than those of metal abutment(P<.05). 3. In both of the implant systems, the difference in removal torque ratio between zirconia abutment and metal abutment was not significant(P>.05). 4. In metal abutments, the removal torque ratio of GS II system(internal conical joint system) was lower than that of US II system(external butt joint system)(P<.05). 5. In zirconia abutments, the difference in removal torque ratio between the two implant systems was not significant(P>.05). Conclusion: Zirconia abutment had a good screw joint stability in the condition of one million cycling loading.

Influence of air abrasion and different dentin sealing techniques on microtensile bond strength to dentin (상아질의 봉쇄 시기와 표면처리 방법이 미세인장 결합강도에 미치는 영향)

  • Kang, Dong-Ho;Han, Chong-Hyun;Park, Jung-Won;Kim, Sun-Jai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.8-15
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the effect of various methods of dentin bonding agent application and air abrasion pretreatment on microtensile bond strength between dentin and resin, using a self-etching adhesive system. Material and methods: Thirty freshly extracted human molars were obtained and divided into 6 groups of 5 teeth. A 2-step self etching adhesive system (Clearfil SE Bond) was used for all groups. The control specimens were prepared using a direct immediate bonding technique. The delayed dentin sealing specimens were prepared using an indirect approach without dentin prebonding. The immediate dentin sealing specimens were prepared using dentin prebonding immediately following preparation. Immediate dentin sealing teeth and delayed dentin sealing teeth had provisional restorations using Fermit for two weeks. Then all specimens of each group were divided into two groups of three, depending on air abrasion pretreatment. Composite "crowns" were incrementally built on and specimens were stored in water for 24 hours. All teeth were prepared for a microtensile bond strength test. Bond strength data were analyzed with a one-way ANOVA test, and post hoc comparison was done using the Scheffe's test. Results: The mean microtensile bond strengths of all groups were not statistically different from each other. Conclusion: When preparing teeth for indirect restorations, IDS and DDS with Clearfil SE bond, have no difference on the microtensile bond strength between dentin and resin. Air abrasion pretreatment did not affect the microtensile bond strength when using IDS and DDS with Clearfil SE bond.

The Effect of Three Surface Sealants on Microleakage of Class V Composite Resin Restorations (복합레진으로 수복한 5급 와동의 미세누출에 대한 3종의 레진 표면 전색제의 효과)

  • Lee, Won-Cheol;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.182-190
    • /
    • 2009
  • Statement of problem: Microleakage at the occlusal and gingival margin of Class V cavities restored with composite resin has traditionally been considered an obstacle to successful restoration. Purpose: The aim of this study was to assess the effectiveness of three different surface sealants(Fortify, Permaseal and Biscover LV) on the marginal sealing of Class V light-activated composite resin restorations(Z250). Material and methods: Forty noncarious human premolars and molars extracted within a three-month period were selected. Class V cavities with the occlusal margin in enamel and gingival margin in cementum were prepared in both buccal and lingual surfaces. The teeth, randomly assigned in four groups with twenty cavities in each group, were restored with composite resin after applying an adhesive system(Clearfil SE bond). After the finishing and polishing procedures, the restorations were covered with a specific surface sealants, except for the control samples, which were not sealed. After placing restorations, the specimens were thermocycled, and immersed in a 2% methylene blue solution for twenty four hours and sectioned longitudinally. The marginal microleakage was evaluated at the occlusal and gingival interfaces using a microscope and compared among the four groups using ANOVA test and Wilcoxon Rank-Sum test($\alpha$=0.05). Results: Statistical analysis showed that there was significantly less leakage when the surface sealants were used than there was in control group(P<.05). There were no significant differences of microleakage at occlusal and gingival margins among groups. There were no significant differences between microleakage of occlusal and gingival margins in each group. Fortify was not statistically different from control group at the gingival margin(P>.05). Conclusion: Application of surface sealants was an effective method of surface coating in reducing microleakage at occlusal and gingival margins of Class V composite resin restorations. However, it is certain that some microleakage still occurred despite the application of surface sealants, especially gingival margins.

A Comparative Study of Initial Healing Process in White Rats after Gingivectomy using $CO_2$ Laser of different watts (($CO_2$)레이저를 이용한 백서의 치은절제술시 출력에 따른 초기 치유과정의 비교)

  • Cho, Kyoo-Sung;Hong, Sung-Jae;Choi, Seong-Ho;Chai, Jung-Kiu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.603-619
    • /
    • 1997
  • The use of laser in the treatment of soft tissue minimizes hemorrhage, provides better view of the operating field, and thereby minimizes operating time. Also, there will be far less post-operative swelling, pain and scar formation, and sterilizing effect are shown in some portions of the wound site. All these advantages of laser therapy contribute to its widespread use in the field of medicine and dentistry. Regarding such facts, we used CO2 laser of different watts in gingivectomy for white rats to compare initial healing process. For the control group, the least amount of output in performing gingivectomy(4watts) was offered, and for the experimental group, 6watts was given. Animals were sacrificed on the second, third days, 1 weeks, 2 weeks, and 3 weeks after operation, and their specimens were histologically analyzed. The following results were obtained: 1. Blood clot of small size was observed in both the control and experimental groups after two days, and no more thereafter. 2. In both the control and experimental groups, the inflammation zone size was the greatest after two days, and it decreased gradually to become almost invisble by the second week. The experimental group showed larger size of inflammation zone during second and third days: however, there was no difference after one week. 3. Granulation tissue in both the control and experimental groups showed gradual maturation with time, and by the second week, it was almost replaced by normal connective tissue. By the third week, complete healing pattern was observed. The experimental group showed larger granulation tissue than the control group until the third day, but there was no significant difference after one week. 4. In both the control and experimental groups, gingival epithelialization began on the second day. After one week, regeneration of rete peg and partial formation of junctional epithelium were observed: by the second week, keratinization of oral sulcular epithelium began, and it was completed by the third week.

  • PDF

Influencing factors on the final color of laminate veneer restorations with various IPS Empress Esthetic$^{(R)}$ ingots (다양한 IPS Empress Esthetic$^{(R)}$ ingot으로 제작한 laminate veneer의 최종 색조에 대한 영향)

  • Yang, Mi-Seon;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.308-315
    • /
    • 2011
  • Purpose: The purpose of this study was to colorimetrically evaluate the masking effect of different opacity of ingots on the final shade of IPS Empress Esthetic$^{(R)}$ laminate veneer restorations using the CIE $L^*a^*b^*$ system. Materials and methods: Six porcelain disks of IPS Empress Esthetic$^{(R)}$ system (translucency: E 01, E 03, E 0C-1, E TC-1, E TC-2, E TC-3) were fabricated with 7 mm in diameter and 0.6 mm in thickness. Six extracted human incisors (shade: A1, A3, A4, B2, B3, C3) were used as the abutment specimens. The incisors were prepared using a diamond wheel and made with a flat labial surface on the middle 1/3. For each combination of different shades of abutments and copings, the change in color was measured with a colorimeter. CIE $L^*a^*b^*$ coordinates were recorded for each specimen. Color differences (${\Delta}E$) were calculated. Descriptive statistical analysis was done. Results: ${\Delta}E$ values were significantly affected by coping translucency and abutment shade (P<.05). The color differences (${\Delta}E$) of laminate veneers among abutments with A3, B3, C3, and A4 shade were mostly below 2.7 which was within the clinically acceptable range, while color differences between A4 and B2, A3 and B2, and A1 and A4 showed more than 2.7. Conclusion: The final color of IPS Empress Esthetic$^{(R)}$ laminate veneers were significantly influenced by translucency of the coping and shade of abutment teeth. The large value difference of abutment teeth limited the masking ability by laminate veneers.