• Title/Summary/Keyword: Effect study

Search Result 116,815, Processing Time 0.157 seconds

Problems in the Korean National Family Planning Program (한국가족계획사업(韓國家族計劃事業)의 문제점(問題點))

  • Hong, Jong-Kwan
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.2 no.2
    • /
    • pp.27-36
    • /
    • 1975
  • The success of the family planning program in Korea is reflected in the decrease in the growth rate from 3.0% in 1962 to 2.0% in 1971, and in the decrease in the fertility rate from 43/1,000 in 1960 to 29/1,000 in 1970. However, it would be erroneous to attribute these reductions entirely to the family planning program. Other socio-economic factors, such as the increasing age at marriage and the increasing use of induced abortions, definitely had an impact on the lowered growth and fertility rate. Despite the relative success of the program to data in meeting its goals, there is no room for complacency. Meeting the goal of a further reduction in the population growth rate to 1.3% by 1981 is a much more difficult task than any one faced in the past. Not only must fertility be lowered further, but the size of the target population itself will expand tremendously in the late seventies; due to the post-war baby boom of the 1950's reaching reproductive ages. Furthermore, it is doubtful that the age at marriage will continue to rise as in the past or that the incidence of induced abortion will continue to increase. Consequently, future reductions in fertility will be more dependent on the performance of the national family planning program, with less assistance from these non-program factors. This paper will describe various approaches to help to the solution of these current problems. 1. PRACTICE RATE IN FAMILY PLANNING In 1973, the attitude (approval) and knowledge rates were quite high; 94% and 98% respectively. But a large gap exists between that and the actual practice rate, which is only 3695. Two factors must be considered in attempting to close the KAP-gap. The first is to change social norms, which still favor a larger family, increasing the practice rate cannot be done very quickly. The second point to consider is that the family planning program has not yet reached all the eligible women. A 1973 study determineded that a large portion, 3096 in fact, of all eligible women do not want more children, but are not practicing family planning. Thus, future efforts to help close the KAP-gap must focus attention and services on this important large group of potential acceptors. 2. CONTINUATION RATES Dissatisfaction with the loop and pill has resulted in high discontinuation rates. For example, a 1973 survey revealed that within the first six months initial loop acceptance. nearly 50% were dropouts, and that within the first four months of inital pill acceptance. nearly 50% were dropouts. These discontinuation rates have risen over the past few years. The high rate of discontinuance obviously decreases the contraceptive effectiveness. and has resulted in many unwanted births which is directly related to the increase of induced abortions. In the future, the family planning program must emphasize the improved quality of initial and follow-up services. rather than more quantity, in order to insure higher continuation rates and thus more effective contraceptive protection. 3. INDUCED ABORTION As noted earlier. the use of induced abortions has been increase yearly. For example, in 1960, the average number of abortions was 0.6 abortions per women in the 15-44 age range. By 1970. that had increased to 2 abortions per women. In 1966. 13% of all women between 15-44 had experienced at least one abortion. By 1971, that figure jumped to 28%. In 1973 alone, the total number of abortions was 400,000. Besides the ever incre.sing number of induced abortions, another change has that those who use abortions have shifted since 1965 to include- not. only the middle class, but also rural and low-income women. In the future. in response to the demand for abortion services among rural and low-income w~men, the government must provide and support abortion services for these women as a part of the national family planning program. 4. TARGET SYSTIi:M Since 1962, the nationwide target system has been used to set a target for each method, and the target number of acceptors is then apportioned out to various sub-areas according to the number of eligible couples in each area. Because these targets are set without consideration for demographic factors, particular tastes, prejudices, and previous patterns of acceptance in the area, a high discontinuation rate for all methods and a high wastage rate for the oral pill and condom results. In the future. to alleviate these problems of the methodbased target system. an alternative. such as the weighted-credit system, should be adopted on a nation wide basis. In this system. each contraceptive method is. assigned a specific number of points based upon the couple-years of protection (CYP) provided by the method. and no specific targets for each method are given. 5. INCREASE OF STERILIZA.TION TARGET Two special projects. the hospital-based family planning program and the armed forces program, has greatly contributed to the increasing acceptance in female and male sterilization respectively. From January-September 1974, 28,773 sterilizations were performed. During the same time in 1975, 46,894 were performed; a 63% increase. If this trend continues, by the end of 1975. approximately 70,000 sterilizations will have been performed. Sterilization is a much better method than both the loop and pill, in terms of more effective contraceptive protection and the almost zero dropout rate. In the future, the. family planning program should continue to stress the special programs which make more sterilizations possible. In particular, it should seek to add the laparoscope techniques to facilitate female sterilization acceptance rates. 6. INCREASE NUMBER OF PRIVATE ACCEPTORS Among the current family planning users, approximately 1/3 are in the private sector and thus do not- require government subsidy. The number of private acceptors increases with increasing urbanization and economic growth. To speed this process, the government initiated the special hospital based family planning program which is utilized mostly by the private sector. However, in the future, to further hasten the increase of private acceptors, the government should encourage doctors in private practice to provide family planning services, and provide the contraceptive supplies. This way, those do utilize the private medical system will also be able to receive family planning services and pay for it. Another means of increasing the number of private acceptors, IS to greatly expand the commercial outlets for pills and condoms beyond the existing service points of drugstores, hospitals, and health centers. 7. IE&C PROGRAM The current preferred family size is nearly twice as high as needed to achieve a stable poplation. Also, a strong boy preference hinders a small family size as nearly all couples fuel they must have at least one or more sons. The IE&C program must, in the future, strive to emphasize the values of the small family and equality of the sexes. A second problem for the IE&C program to work. with in the: future is the large group of people who approves family planning, want no more children, but do not practice. The IE&C program must work to motivate these people to accept family planning And finally, for those who already practice, an IE&C program in the future must stress continuation of use. The IE&C campaign, to insure highest effectiveness, should be based on a detailed factor analysis of contraceptive discontinuance. In conclusion, Korea faces a serious unfavorable sociodemographic situation- in the future unless the population growth rate can be curtailed. And in the future, the decrease in fertility will depend solely on the family planning program, as the effect of other socio-economic factors has already been maximumally felt. A second serious factor to consider is the increasing number of eligible women due to the 1950's baby boom. Thus, to meet these challenges, the program target must be increased and the program must improve the effectiveness of its current activities and develop new programs.

  • PDF

State of Mind in the Flow 4-Channel Model and Play (플로우 4경로모형의 마음상태와 플레이(play))

  • Sohn, Jun-Sang
    • Journal of Global Scholars of Marketing Science
    • /
    • v.17 no.2
    • /
    • pp.1-29
    • /
    • 2007
  • The flow theory becomes one of the most important frameworks in the internet research arena. Hoffman and Novak proposed a hierarchical flow model showing the antecedents and outcomes of flow and the relationship among these variables in the hyper-media computer circumstances (Hoffman and Novak 1996). This model was further tested after their initial research (Novak, Hoffman, and Yung 2000). At their paper, Hoffman and Novak explained that the balance of challenge and skill leads to flow which means the positive optimal state of mind (Hoffman and Novak 1996). An imbalance between challenge and skill, leads to negative states of mind like anxiety, boredom, apathy (Csikszentmihalyi and Csikszentmihalyi 1988). Almost all research on the flow 4-channel model have been focusingon flow, the positive state of mind (Ellis, Voelkl, and Morris 1994 Mathwick and Rigdon 2004). However, it also needs to examine the formation of the negative states of minds and their outcomes. Flow researchers explain play or playfulness as antecedents or the early state of flow. However, play has been regarded as a distinct concept from flow in the flow literatures (Hoffman and Novak 1996; Novak, Hoffman, and Yung 2000). Mathwick and Rigdon discovered the influences of challenge and skill on play; they also observed the influence of play on web-loyalty and brand loyalty (Mathwick and Rigdon 2004). Unfortunately, they did not go so far as to test the influences of play on state of mind. This study focuses on the relationships between state of mind in the flow 4-channel model and play. Early research has attempted to hypothetically explain state of mind in flow theory, but has not been tested except flow until now. Also the importance of play has been emphasized in the flow theory, but has not been tested in the flow 4-channel model context. This researcher attempts to analyze the relationships among state of mind, skill of play, challenge, state of mind and web loyalty. For this objective, I developed a measure for state of mind and defined the concept of play as a trait. Then, the influences of challenge and skill on the state of mind and play under on-line shopping conditions were tested. Also the influences of play on state of mind were tested and those of flow and play on web loyalty were highlighted. 294 undergraduate students participated in this research survey. They were asked to respond about their perceptions of challenge, skill, state of mind, play, and web-loyalty to on-line shopping mall. Respondents were restricted to students who bought products on-line in a month. In case of buying products at two or more on-line shopping malls, they asked to respond about the shopping mall where they bought the most important one. Construct validity, discriminant validity, and convergent validity were used to check the measurement validations. Also, Cronbach's alpha was used to check scale reliability. A series of exploratory factor analyses was conducted. This researcher conducted confirmatory factor analyses to assess the validity of measurements. All items loaded significantly on their respective constructs. Also, all reliabilities were greater than.70. Chi-square difference tests and goodness of fit tests supported discriminant and convergent validity. The results of clustering and ANOVA showed that high challenge and high skill leaded to flow, low challenge and high skill leaded to boredom, and low challenge and low skill leaded to apathy. But, it was different from my expectation that high challenge and low skill didnot lead to anxiety but leaded to apathy. The results also showed that high challenge and high skill, and high challenge and low skill leaded to the highest play. Low challenge leaded to low play. 4 Structural Equation Models were built by flow, anxiety, boredom, apathy for analyzing not only the impact of play on state of mind and web-loyalty, but also that of state of mind on web-loyalty. According the analyses results of these models, play impacted flow and web-loyalty positively, but impacted anxiety, boredom, and apathy negatively. Results also showed that flow impacted web-loyalty positively, but anxiety, boredom, and apathy impacted web-loyalty negatively. The interpretations and implications of the test results of the hypotheses are as follows. First, respondents belonging to different clusters based on challenge and skill level experienced different states of mind such as flow, anxiety, boredom, apathy. The low challenge and low skill group felt the highest anxiety and apathy. It could be interpreted that this group feeling high anxiety or fear, then avoided attempts to shop on-line. Second, it was found that higher challenge leads to higher levels of play. Test results show that the play level of the high challenge and low skill group (anxiety group) was higher than that of the high challenge and high skill group (flow group). However, this was not significant. Third, play positively impacted flow and negatively impacted boredom. The negative impacts on anxiety and apathy were not significant. This means that the combination of challenge and skill creates different results. Forth, play and flow positively impacted web-loyalty, but anxiety, boredom, apathy had negative impacts. The effect of play on web-loyalty was stronger in case of anxiety, boredom, apathy group than fl ow group. These results show that challenge and skill influences state of mind and play. Results also demonstrate how play and flow influence web-loyalty. It implies that state of mind and play should be the core marketing variables in internet marketing. The flow theory has been focusing on flow and on the positive outcomes of flow experiences. But, this research shows that lots of consumers experience the negative state of mind rather than flow state in the internet shopping circumstance. Results show that the negative state of mind leads to low or negative web-loyalty. Play can have an important role with the web-loyalty when consumers have the negative state of mind. Results of structural equation model analyses show that play influences web-loyalty positively, even though consumers may be in the negative state of mind. This research found the impacts of challenge and skill on state of mind in the flow 4-channel model, not only flow but also anxiety, boredom, apathy. Also, it highlighted the role of play in the flow 4-channel model context and impacts on web-loyalty. However, tests show a few different results from hypothetical expectations such as the highest anxiety level of apathy group and insignificant impacts of play on anxiety and apathy. Further research needs to replicate this research and/or to compare 3-channel model with 4-channel model.

  • PDF

Comparison of Single-Breath and Intra-Breath Method in Measuring Diffusing Capacity for Carbon Monoxide of the Lung (일산화탄소 폐확산능검사에서 단회호흡법과 호흡내검사법의 비교)

  • Lee, Jae-Ho;Chung, Hee-Soon;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.555-568
    • /
    • 1995
  • Background: It is most physiologic to measure the diffusing capacity of the lung by using oxygen, but it is so difficult to measure partial pressure of oxygen in the capillary blood of the lung that in clinical practice it is measured by using carbon monoxide, and single-breath diffusing capacity method is used most widely. However, since the process of withholding the breath for 10 seconds after inspiration to the total lung capacity is very hard to practice for patients who suffer from cough, dyspnea, etc, the intra-breath lung diffusing capacity method which requires a single exhalation of low-flow rate without such process was devised. In this study, we want to know whether or not there is any significant difference in the diffusing capacity of the lung measured by the single-breath and intra-breath methods, and if any, which factors have any influence. Methods: We chose randomly 73 persons without regarding specific disease, and after conducting 3 times the flow-volume curve test, we selected forced vital capacity(FVC), percent of predicted forced vital capacity, forced expiratory volume within 1 second($FEV_1$), percent of forced expiratory volume within 1 second, the ratio of forced expiratory volume within 1 second against forced vital capacity($FEV_1$/FVC) in test which the sum of FVC and $FEV_1$ is biggest. We measured the diffusing capacity of the lung 3 times in each of the single-breath and intra-breath methods at intervals of 5 minutes, and we evaluated which factors have any influence on the difference of the diffusing capacity of the lung between two methods[the mean values(ml/min/mmHg) of difference between two diffusing capacity measured by two methods] by means of the linear regression method, and obtained the following results: Results: 1) Intra-test reproducibility in the single-breath and intra-breath methods was excellent. 2) There was in general a good correlation between the diffusing capacity of the lung measured by a single-breath method and that measured by the intra-breath method, but there was a significant difference between values measured by both methods($1.01{\pm}0.35ml/min/mmHg$, p<0.01) 3) The difference between the diffusing capacity of the lung measured by both methods was not correlated to FVC, but was correlated to $FEV_1$, percent of $FEV_1$, $FEV_1$/FVC and the gradient of methane concentration which is an indicator of distribution of ventilation, and it was found as a result of the multiple regression test, that the effect of $FEV_1$/FVC was most strong(r=-0.4725, p<0.01) 4) In a graphic view of the difference of diffusing capacity measured by single-breath and intra-breath method and $FEV_1$/FVC, it was found that the former was divided into two groups in section where $FEV_1$/FVC is 50~60%, and that there was no significant difference between two methods in the section where $FEV_1$/FVC is equal or more than 60% ($0.05{\pm}0.24ml/min/mmHg$, p>0.1), but there was significant difference in the section, less than 60%($-4.5{\pm}0.34ml/min/mmHg$, p<0.01). 5. The diffusing capacity of the lung measured by the single-breath and intra-breath method was the same in value($24.3{\pm}0.68ml/min/mmHg$) within the normal range(2%/L) of the methane gas gradient, and there was no difference depending on the measuring method, but if the methane concentration gradients exceed 2%/L, the diffusing capacity of the lung measured by single-breath method became $15.0{\pm}0.44ml/min/mmHg$, and that measured by intra-breath method, $11.9{\pm}0.51ml/min/mmHg$, and there was a significant difference between them(p<0.01). Conclusion: Therefore, in case where $FEV_1$/FVC was less than 60%, the diffusing capacity of the lung measured by intra-breath method represented significantly lower value than that by single-breath method, and it was presumed to be caused largely by a defect of ventilation-distribution, but the possibility could not be excluded that the diffusing capacity of the lung might be overestimated in the single-breath method, or the actual reduction of the diffusing capacity of the lung appeared more sensitively in the intra-breath method.

  • PDF

Effect of Smoking and Drinking Habits on the Nutrient Intakes and Health of Middle and High School Boy Students (남자 중.고생의 흡연과 음주습관이 영양소 섭취 및 건강상태에 미치는 영향)

  • Shin, Kyung-Ok;An, Chang-Hun;Hwang, Hyo-Jeong;Choi, Kyung-Soon;Chung, Keun-Hee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.6
    • /
    • pp.694-708
    • /
    • 2009
  • The principal objective of this study was to determine the effects of smoking & drinking on the diet, nutrient intake, and overall health. A sample of 262 youths, aged 16 to 18 year-old, was randomly selected from Seoul and its vicinity. The subjects participated by answering survey questions including general questions, questions regarding health, smoking & drinking habits, dietary habits, nutrient intake, physical characteristics, and smoking cessation plans. The average height, weight, and BMI of the subjects were $173.5{\pm}6.8\;cm$, $64.8{\pm}11.8\;kg$, and $21.4{\pm}3.7\;kg/m^2$, respectively. Among the subjects, 88% appeared to be interested in health and 43.5% of youth asserted that the best way to keep healthy was to engage in regular exercise. Among 63 smokers, 52 students (82.5%) used alcoholic beverages while 11 students (17.5%) did not use alcoholic beverages, meaning that smoking was a causative factor in drinking. 55.6% of youth reported beginning to smoke in middle school, and 38.1% of them asserted that curiosity was the motive for smoking. The youth reported that the craving for smoking was highest when hungry, and the best place to smoke was the restroom. 20 students (69.0%) answered that the only way to quit smoking was just to stop. 12 students (44.4%) reported that the main reason for failures in smoking cessation attempts was a lack of intention or willpower. 87.1% of all subjects answered that they were inclined to quit smoking, and 56.7% of them would be interested in attending a smoking cessation program if they had the opportunity. Among the smoking and drinking group, 50% of drinkers began to drink in high school, and the reason for drinking given was peer pressure-40% of drinkers answered that they wished to quit drinking. 34.4% of students appeared to have breakfast everyday, but 16.4% of students answered that they had quit eating breakfast. 52.5% of all students reported that the principal reason for overeating was the presence of one's favorite food, and the smoking and drinking group reported overeating more frequently than other groups (p<0.05). 72.6% of all subjects reported eating interim meals $1{\sim}2$ times daily, 36.4% of smokers ate carbonated beverages, 38.5% ate ice cream as a interim meal, and 38.5% of the drinking and smoking groups ate fruits, 26.9% of them ate fried foods, and some of them ate fast foods as a interim meal. Among smokers, the ratio of eating fat-rich foods, and meats such as kalbi and samgyupsal more than two times per week was higher, and 54.3% of smokers ate ice cream, cookies, and carbonated beverages more than two times per week (p<0.05). The total nutrient intake of the $15{\sim}19$-year youth group was much higher than the standard value. The energy intake of the smoking group and the drinking and smoking group was significantly higher than that of the normal group (p<0.05). Intakes of phosphorus (p<0.05), cholesterol (p<0.05), and sodium (p<0.05) were the highest among all groups. Accordingly, it is recommended that practical education programs be implemented to teach young students to resist peer pressures to smoke and drink. Additionally, education that acknowledges the importance of nutrition is necessary to avoid preferential eating and overeating due to smoking and drinking.such education can also teach students to eat a balanced diet and improve their physical development.

A Study on Jurisdiction under the International Aviation Terrorism Conventions (국제항공테러협약의 관할권 연구)

  • Kim, Han-Taek
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.24 no.1
    • /
    • pp.59-89
    • /
    • 2009
  • The objectives of the 1963 Tokyo Convention cover a variety of subjects, with the intention of providing safety in aircraft, protection of life and property on board, and promoting the security of civil aviation. These objectives will be treated as follows: first, the unification of rules on jurisdiction; second, the question of filling the gap in jurisdiction; third, the scheme of maintaining law and order on board aircraft; fourth, the protection of persons acting in accordance with the Convention; fifth, the protection of the interests of disembarked persons; sixth, the question of hijacking of aircraft; and finally some general remarks on the objectives of the Convention. The Tokyo Convention mainly deals with general crimes such as murder, violence, robbery on board aircraft rather than aviation terrorism. The Article 11 of the Convention deals with hijacking in a simple way. As far as aviation terrorism is concerned 1970 Hague Convention and 1971 Montreal Convention cover the hijacking and sabotage respectively. The Problem of national jurisdiction over the offence and the offender was as tangled at the Hague and Montreal Convention, as under the Tokyo Convention. Under the Tokyo Convention the prime base of jurisdiction is the law of the flag (Article 3), but concurrent jurisdiction is also allowed on grounds of: territorial principle, active nationality and passive personality principle, security of the state, breach of flight rules, and exercise of jurisdiction necessary for the performance of obligations under multilateral agreements (Article 4). No Criminal jurisdiction exercised in accordance with national law is excluded [Article 3(2)]. However, Article 4 of the Hague Convention(hereafter Hague Article 4) and Article 5 of the Montreal Convention(hereafter Montreal Article 5), dealing with jurisdiction have moved a step further, inasmuch as the opening part of both paragraphs 1 and 2 of the Hague Article 4 and the Montreal Article 5 impose an obligation on all contracting states to take measures to establish jurisdiction over the offence (i.e., to ensure that their law is such that their courts will have jurisdiction to try offender in all the circumstances covered by Hague Article 4 and Montreal Article 5). The state of registration and the state where the aircraft lands with the hijacker still on board will have the most interest, and would be in the best position to prosecute him; the paragraphs 1(a) and (b) of the Hague Article 4 and paragraphs 1(b) and (c) of the Montreal Article 5 deal with it, respectively. However, paragraph 1(b) of the Hague Article 4 and paragraph 1(c) of the Montreal Article 5 do not specify if the aircraft is still under the control of the hijacker or if the hijacker has been overpowered by the aircraft commander, or if the offence has at all occurred in the airspace of the state of landing. The language of the paragraph would probably cover all these cases. The weaknesses of Hague Article 4 and Montreal Article 5 are however, patent. The Jurisdictions of the state of registration, the state of landing, the state of the lessee and the state where the offender is present, are concurrent. No priorities have been fixed despite a proposal to this effect in the Legal Committee and the Diplomatic Conference, and despite the fact that it was pointed out that the difficulty in accepting the Tokyo Convention has been the question of multiple jurisdiction, for the reason that it would be too difficult to determine the priorities. Disputes over the exercise of jurisdiction can be endemic, more so when Article 8(4) of the Hague Convention and the Montreal Convention give every state mentioned in Hague Article 4(1) and Montreal Article 5(1) the right to seek extradition of the offender. A solution to the problem should not have been given up only because it was difficult. Hague Article 4(3) and Montreal Article 5(3) provide that they do not exclude any criminal jurisdiction exercised in accordance with national law. Thus the provisions of the two Conventions create additional obligations on the state, and do not exclude those already existing under national laws. Although the two Conventions do not require a state to establish jurisdiction over, for example, hijacking or sabotage committed by its own nationals in a foreign aircraft anywhere in the world, they do not preclude any contracting state from doing so. However, it has be noted that any jurisdiction established merely under the national law would not make the offence an extraditable one under Article 8 of the Hague and Montreal Convention. As far as international aviation terrorism is concerned 1988 Montreal Protocol and 1991 Convention on Marking of Plastic Explosives for the Purpose of Detention are added. The former deals with airport terrorism and the latter plastic explosives. Compared to the other International Terrorism Conventions, the International Aviation Terrorism Conventions do not have clauses of the passive personality principle. If the International Aviation Terrorism Conventions need to be revised in the future, those clauses containing the passive personality principle have to be inserted for the suppression of the international aviation terrorism more effectively. Article 3 of the 1973 Convention on the Prevention and Punishment of Crimes Against Internationally Protected Persons, Including Diplomatic Agents, Article 5 of the 1979 International Convention against the Taking of Hostages and Article 6 of the 1988 Convention for the Suppression of Unlawful Acts Against the Safety of Maritime Navigation would be models that the revised International Aviation Terrorism Conventions could follow in the future.

  • PDF

Comparison of Effects of Normothermic and Hypothermic Cardiopulmonary Bypass on Cerebral Metabolism During Cardiac Surgery (체외순환 시 뇌 대사에 대한 정상 체온 체외순환과 저 체온 체외순환의 임상적 영향에 관한 비교연구)

  • 조광현;박경택;김경현;최석철;최국렬;황윤호
    • Journal of Chest Surgery
    • /
    • v.35 no.6
    • /
    • pp.420-429
    • /
    • 2002
  • Moderate hypothermic cardiopulmonary bypass (CPB) has commonly been used in cardiac surgery. Several cardiac centers recently practice normothermic CPB in cardiac surgery, However, the clinical effect and safety of normothermic CPB on cerebral metabolism are not established and not fully understood. This study was prospectively designed to evaluate the clinical influence of normothermic CPB on brain metabolism and to compare it with that of moderate hypothermic CPB. Material and Method: Thirty-six adult patients scheduled for elective cardiac surgery were randomized to receive normothermic (nasopharyngeal temperature >34.5 $^{\circ}C$, n=18) or hypothermic (nasopharyngeal temperature 29~3$0^{\circ}C$, n=18) CPB with nonpulsatile pump. Middle cerebral artery blood flow velocity (VMCA), cerebral arteriovenous oxygen content difference (CAVO$_{2}$), cerebral oxygen extraction (COE), modified cerebral metabolic rate for oxygen (MCMRO$_{2}$), cerebral oxygen transport (TEO$_{2}$), cerebral venous desaturation (oxygen saturation in internal jugular bulb blood$\leq$50 %), and arterial and internal jugular bulb blood gas analysis were measured during six phases of the operation: Pre-CPB (control), CPB-10 min, Rewarm-1 (nasopharyngeal temperature 34 $^{\circ}C$ in the hypothermic group), Rewarm-2 (nasopharyngeal temperature 37 $^{\circ}C$ in the both groups), CPB-off and Post-CPB (skin closure after CPB-off). Postoperaitve neuropsychologic complications were observed in all patients. All variables were compared between the two groups. Result: VMCA at Rewarm-2 was higher in the hypothermic group (153.11$\pm$8.98%) than in the normothermic group (131.18$\pm$6.94%) (p<0.05). CAVO$_{2}$ (3.47$\pm$0.21 vs 4.28$\pm$0.29 mL/dL, p<0.05), COE (0.30$\pm$0.02 vs 0.39$\pm$0.02, p<0.05) and MCMRO$_{2}$ (4.71 $\pm$0.42 vs 5.36$\pm$0.45, p<0.05) at CPB-10 min were lower in the hypothermic group than in the normothermic group. The hypothermic group had higher TEO$_{2}$ than the normothermic group at CPB-10 (1,527.60$\pm$25.84 vs 1,368.74$\pm$20.03, p<0.05), Rewarm-2 (1,757.50$\pm$32.30 vs 1,478.60$\pm$27.41, p<0.05) and Post-CPB (1,734.37$\pm$41.45 vs 1,597.68$\pm$27.50, p<0.05). Internal jugular bulb oxygen tension (40.96$\pm$1.16 vs 34.79$\pm$2.18 mmHg, p<0.05), saturation (72.63$\pm$2.68 vs 64.76$\pm$2.49 %, p<0.05) and content (8.08$\pm$0.34 vs 6.78$\pm$0.43 mL/dL, p<0.05) at CPB-10 were higher in the hypothermic group than in the normothermic group. The hypothermic group had less incidence of postoperative neurologic complication (delirium) than the normothermic group (2 vs 4 patients, p<0.05). Lasting periods of postoperative delirium were shorter in the hypothermic group than in the normothermic group (60 vs 160 hrs, p<0.01). Conclusion: These results indicate that normothermic CPB should not be routinely applied in all cardiac surgery, especially advanced age or the clinical situations that require prolonged operative time. Moderate hypothermic CPB may have beneficial influences relatively on brain metabolism and postoperative neuropsychologic outcomes when compared with normothermic CPB.

Studies on Fire-Retardant-Treatment and Press Drying of Plywood (합판(合板)의 내화처리(耐火處理)와 열판건조(熱板乾燥)에 관(關)한 연구(硏究))

  • Lee, Phil-Woo;Kim, Jong-Man
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.5-37
    • /
    • 1982
  • Plywood used for construction as a decorative inner material is inflammable to bring large fire accidents and burn out human life and their properties. To diminish the fire disaster, fire retardant plywood has been required indeed. In the methods of manufacturing the fire retardant plywood the soaking method is occasionally used. However after soaking plywood into fire retardant chemical solutions, redrying of soaked plywood is the most important. In this study, 3.5mm thin and 5.0mm thick plywoods were selected for fire retardant treatment. Treating solutions were prepared for 20% dilute solutions of ammonium sulfate, monoammonium phosphate, diammonium phosphate, borax-boric acid and minalith, and water solution. 1-, 3-, 6-, and 9 hour-soaking treatments were applied and after treatments hot plate drying was applied to those treated plywoods at $90^{\circ}C$, $120^{\circ}C$ and $150^{\circ}C$, of press temperature. Drying rates, drying curves, water absorption rates of fire retardant chemicals, weight per volume and fire retardant degree of plywood were investigated. The results may be summarized as follows: 1. The plywoods treated with ammonium sulfate, monoammonium phosphate and diammonium phosphate and diammonium phosphate showed increase of chemical absorption rate with proportion to increase of treating time, but not in case of the plywood treated with borax-boric acid and minalith. 2. In the treatment of definite time, the absorption rate per unit of volume of plywood showed higher in thin plywood (thickness of 3.5mm) than in thick plywood (thickness of 5.0mm). In both thin and thick plywoods, the highest absorption rate was observed in 9 hour-treatment of ammonium sulfate. The value was 1.353kg/$(30cm)^3$ in thin plywood and 1.356kg/$(30cm)^3$ in thick plywood. 3. The volume per weight of plywood after chemical treatment increased remarkably and. after hot plate drying, the values were to a little extent higher than before chemical treatment. 4. The swelling rates of thickness in chemical-treated plywoods increased similarly with that of water-treated plywood in 1- and 3 hour-treatment of both thin and thick plywoods. But in 6- and 9 hour-treatment, the greater increased value showed in water-treated ply wood than any other chemical, especially in thick plywood. 5. The shrinkage rates after hot plate drying showed the same tendency as the swelling rate, and the rate showed the increasing tendency with proportion to increase of treating time in thick plywood of both chemical and water treatments. 6. Among drying curves, the curves of water-treated plywood placed more highly than chemical-treated plywood without-relation to thickness in 6- and 9 hour-treatment except in 1- and 3 hour-treatment. 7. The drying rate related to thickness of treated plywood, was twice above in thin plywood compared with thick plywood. 8. The drying rate remarkably increased with proportion to increase of the plate temperature and, the values were respectively 1.226%/min., 6.540%/min., 25.752%/min. in hot plate temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in thin plywood and 0.550%/min., 2.490%/min, 8.187%/min, in hot plate temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in thick plywood. 9. In the treatment at $120^{\circ}C$ of hot plate temperature, the drying rates of chemical-treated plywood showed the highest value in monoammonium phosphate of thin plywood and in diammonium phosphate of thick plywood. But the drying rate of water-treated plywood was highest in 6- and 9 hour-treatment. 10. The fire retardant degree of chemical-treated plywood was higher than that of the untreated plywood as shown in loss of weight, burning time, flame-exhausted time and carbonized area. 11. The fire-retardant effect among fire retardant chemicals were the greatest in diammonium phosphate, the next were in monoammonium phosphate and ammonium sulfate, and the weakest were in borax-boric and minalith.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

A Study on Physical and Mechanical Properties of Sawdustboards combined with Polypropylene Chip and Oriented Thread (폴리프로필렌사(絲)칩과 배향사(配向絲)를 결체(結締)한 톱밥보드의 물리적(物理的) 및 기계적(機械的) 성질(性質)에 관(關)한 연구(硏究))

  • Suh, Jin-Suk;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.1-41
    • /
    • 1988
  • For the purpose of utilizing the sawdust having poor combining properties as board raw material and resulting in dimensional instability of board, polypropylene chip (abbreviated below as PP chip) or oriented PP thread was combined with sawdust particle from white meranti(Shorea sp.). The PP chip was prepared from PP thread in length of 0.25, 0.5, 1.0 and 1.5 cm for conventional blending application. Thereafter, the PP chip cut as above was combined with the sawdust particle by 3, 6, 9, 12 and 15% on the weight basis of board. Oriented PP threads were aligned with spacing of 0.5, 1.0 and 1.5cm along transverse direction of board. The physical and mechanical properties on one, two and three layer boards manufactured with the above combining conditions were investigated. The conclusions obtained at this study were summarized as follows: 1. In thickness swelling, all one layer boards combined with PP chips showed lower values than control sawdustboard, and gradually clear decreasing tendendy with the increase of PP chip composition. Two layer board showed higher swelling value than one layer board, but the majority of boards lower values than control sawdustboard. All three layer boards showed lower swelling values than control sawdustboard. 2. In the PP chip and oriented thread combining board, the swelling values of boards combining 0.5cm spacing oriented thread with 1.0 or 1.5cm long PP chip in 12 and 15% by board weight were much lower than the lowest of one or three layer. 3. In specific gravity of 0.51, modulus of rupture of one layer board combined with 3% PP chip showed higher value than control sawdustboard. However, moduli of rupture of the boards with every PP chip composition did not exceed 80kgf/cm2, the low limit value of type 100 board, Korean Industrial Standard KS F 3104 Particleboards. Moduli of rupture of 6%, 1.5cm-long and 3% PP chip combined boards in specific gravity of 0.63 as well as PP chip combined board in specific gravity of 0.72 exceeded 80kgf/$cm^2$ on KS F 3104. Two layer boards combined with every PI' chip composition showed lower values than control sawdustboard and one layer board. Three layer boards combined with.1.5cm long PP chip in 3, 6 and 9% combination level showed higher values than control sawdustboard, and exceeded 80kgf/$cm^2$ on KS F 3104. 4. In modulus of rupture of PP thread oriented sawdustboard, 0.5cm spacing oriented board showed the highest value, and 1.0 and 1.5cm spacing oriented boards lower values than the 0.5cm. However, all PP thread oriented sawdustboards showed higher values than control saw-dustboard. 5. Moduli of rupture in the majority of PP chip and oriented thread combining boards were higher than 80kgf/$cm^2$ on KS F 3104. Moduli of rupture in the boards combining longer PP chip with narrower 0.5cm spacing oriented thread showed high values. In accordance with the spacing increase of oriented thread, moduli of rupture in the PP chip and oriented thread combining boards showed increasing tendency compared with oriented sawdustboard. 6. Moduli of elasticity in one, two and three layer boards were lower than those of control sawdustboard, however, moduli of elasticity of oriented sawdustboards with 0.5, 1.0 and 1.5cm spacing increased 20, 18 and 10% compared with control sawdustboard, respectively. 7. Moduli of elasticity in the majority of PP chip and oriented thread combining boards in 0.5, 1.0 and 1.5cm oriented spacing showed much higher values than control sawdustboard. On the whole, moduli of elasticity in the oriented boards combined with 9% or less combination level and 0.5cm or more length of PP chip showed higher values than oriented sawdustboard. The increasing effect on modulus of elasticity was shown by the PP chip composition in oriented board with narrow spacing. 8. Internal bond strengths of all one layer PP chip combined boards showed lower values than control sawdust board, however, the PP chip combined boards in specific gravity of 0.63 and 0.72 exceeded 1.5kgf/$cm^2$, the low limit value of type 100 board and 3kgf/$cm^2$, type 200 board on KS F 3104, respectively. And also most of all two, three layer-and oriented boards exceeded 3kgf/$cm^2$ on KS F. 9. In general, screw holding strength of one layer board combined with PP chip showed lower value than control sawdustboard, however, that of two or three layer board combined with PP chip did no decreased tendency, and even screw holding strength with the increase of PP chip composition. In the PP chip and oriented PP thread combining boards, most of the boards showed higher values than control sawdustboard in 9% or less PP chip composition.

  • PDF