• Title/Summary/Keyword: Effect ratio

Search Result 16,683, Processing Time 0.039 seconds

Luminance Performance of a Room with Light Guide and Blind Systems by Mockup Experiments (혼합형 채광조절장치가 실내공간의 휘도분포에 미치는 영향에 관한 Mockup 실험평가)

  • Shin, Hwa Young;Ahn, Hyun Tae;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 2007
  • As ecological design elements, daylighting can be applied to provide adequate illumination on visual tasks to create an attractive visual environment and to save electrical energy. Daylighting control systems reject direct sunlight and penetrate it onto the ceiling or to deep into the room. This study aims to evaluate the luminance environment of sloped light guide with automated venetian blind systems according to sun angle changes. For evaluation, a mock-up model was used and the south facing side-window mounted between the clerestory window and the view window. To assess luminance performance, 3 view points of luminance were monitored. As results, the conventional and lightshelves show ideal luminance ratio between workplane and surroundings(3:1) and workplane and darkness area(2:1) due to total ratio of surroundings and darkness area has lower ratio than workplane. Compared to the lightshelves window, conventional window shows unrelieved effect in between the workplane and brightness area(1:5). It means that there has low deviation according to the required standards. Also, compared to the ratio between the brightness area and darkness area(2~6:1) conventional window with high deviation(10~20:1) provide discomfort glare due to the excessively strong contrast, while lightshelves window shows a required luminance ratio that provide a three-dimensional effect to occupants. Therefore, luminance distribution indicate that application of a lightshelves and blinds not only has a significantly positive effect but also offers higher luminance quality in a daylit room

A Study of Scattered Radiation Effect on Digital Radiography Imaging System (디지털 방사선영상 시스템에서 산란선이 영상 품질에 미치는 영향)

  • Baek, Cheol-Ha
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.71-78
    • /
    • 2017
  • Scattered radiation is inherent phenomenon of x-ray, which occurs to the subject (or patient). Therefore it cannot be avoidable but also interacts as serious noise factor because the only meaningful information on x-ray radiography is primary x-ray photons. The purpose of this study was to quantify scattered radiation for various shooting parameters and to verify the effect of anti-scatter grid. We employed beam stopper method to characterize scatter to primary ratio. To evaluate effect on the projection images calculated contrast to noise ratio of given shooting parameters. From the experiments, we identified the scattered radiation increases in thicker patient and smaller air gap. Moreover, scattered radiation degraded contrast to noise ratio of the projection images. We find out that the anti-scatter grid rejected scattered radiation effectively, however there were not fewer than 100% of scatter to primary ratio in some shooting parameters. The results demonstrate that the scattered radiation was serious problem of medical x-ray system, we confirmed that the scattered radiation was not considerable factor of dig ital radiog raphy.

EFFECT OF OVER-EXPANSION CYCLE IN A SPARK-IGNITION ENGINE USING LATE-CLOSING OF INTAKE VALVE AND ITS THERMODYNAMIC CONSIDERATION OF THE MECHANISM

  • Shiga, S.;Hirooka, Y.;Miyashita, Y.;Yagi, S.;Machacon, H.T.C.;Karasawa, T.;Nakamura, H.
    • International Journal of Automotive Technology
    • /
    • v.2 no.1
    • /
    • pp.1-7
    • /
    • 2001
  • This paper presents further investigation into the effect of over-expansion cycle in a spark-ignition engine. On the basis of the results obtained in previous studies, several combinations of late-closing (LC) of intake valve and expansion ratio were tested using a single-cylinder production engine. A large volume of intake capacity was inserted into the intake manifold to simulate multi-cylinder engines. With the large capacity volume, LC can decrease the pumping loss and then increase the mechanical efficiency. Increasing the expansion ratio from 11 to 23.9 with LC application can produce about 13% improvement of thermal efficiency which was suggested to be caused by the increased cycle efficiency. The decrease of compression ratio from 11 to 5.5 gives little effect on the thermal efficiency if the expansion ratio could be kept constant. Thus, the expansion ratio is revealed to be a determining factor for cycle efficiency, while compression ratio is no more important, which suggests the usefulness of controlling the intake charge with intake valve closure timing. These were successfully explained by simple thermodynamic calculation and thus the mechanism could be verified by the estimation.

  • PDF

Analysis of Lower body on Korean Young Women and the Effect of the Lower body Type on the Shape of Flare Skirt (II) (한국 미혼 여성의 하반신체형 분석과 체형변인이 플레어스커트 입체성능에 미치는 영향(II))

  • 조정미
    • Journal of the Korean Home Economics Association
    • /
    • v.30 no.3
    • /
    • pp.15-32
    • /
    • 1992
  • The purpose of this study was to detect the effect of the lower body type on the shape of flare skirts. The subjects for the wearing test were 50 female students, who were controlled in their hip and waist shapes. The skirts used for wearing test were six types(three flar angles $\times$ two fabric types). The effect of lower body type on the shape of flare skirts was determind by the hemline trace method and the silhouette photography. The data were then analyzed by the repeated measures of analysis of variance and the SNK multiple range test. The results obtained from this study were as follows : 1) When a flare skirt made with larger flare angle and better drapable fabric was worn, the numeric of the nodes increased as the drop value(hip - waist) increased. When a flare skirt made with smaller flare angle was worn, the width of horizontal sectio of hemline increased as the drop value increased. The hemline uneveness decreased on the sides and back as the drop value increased. When a flare skirt made with worse drapable fabric was worn, the sides angle of the flarskirt increased as the drop value increased. 2) When a flare skirt made with larger flare angle was worn, the numeric of nodes increased as the ratio of dropped hip increased. The wave-height increased and the back variation ratio of wave-height was higher than the front variation ratio of wave-height as the ratio of dropped hip increased. The hemiline uneveness decreased on the back as the ratio of dropped hip increased. When a flare skirt made with larger flare angle was worn, the sides angle of the flare skirt increased as the ratio of dropped hip increased.

  • PDF

The Effect of Aspect Ratio on the Flow Characteristics of Elliptic Jets (종횡비에 따른 타원제트의 유동특성에 관한 실험적 연구)

  • 권영철;이상준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.6
    • /
    • pp.1156-1162
    • /
    • 1992
  • The effect of aspect ratio on the flow characteristics of elliptic jets was experimentally investigated. The flow characteristics of sharp-edged elliptic nozzles with aspect ratio of 1 (round nozzle), 2 and 4 were measured by using a 3-D LDV system along the major and minor axis at X/De = 2, 3, 5, 7 and along the centerline up to X/De = 14. At each measurement point mean velocites, turbulent intensities, skewness of three orthogonal velocity components, and Reynolds shear stress were obtained. The Reynolds number based on the nozzle exit velocity and nozzle equivalent diameter(De) was about 4 * 10$^{4}$. Difference in the spreading rate along the major and minor axis was remarkable. The jet half width along the major axis decreased at first and then increased again with going downstream. But the jet width along the minor axis increased steadly. The elliptic jet of AR = 2 had two switching points within the measurement range, while that of AR = 4 had only one. (AAA) : The elliptic jet of AR = 2 showed larger velocity decay rate than that of AR = 1 and AR = 4. The effect of aspect ratio on the flow characteristics of elliptic jets was dominant in the near jet regions of X/De < 7, and the skewness and Reynolds shear stress had quite different distribution depending on the aspect ratio of the elliptic nozzle.

Effect of dietary phytase supplementation with different calcium/phosphorus ratio and net energy reduction on growth performance and nutrient digestibility in finishing pigs

  • Yanjiao Li;Qianqian Zhang;In Ho Kim
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.4
    • /
    • pp.639-646
    • /
    • 2022
  • The present experiment was conducted to assess the effect of Buttiauxella-derived phytase in finishing pigs fed corn/soybean meal diets with an increase in the calcium (Ca)/total phosphorus (P) (Ca/tP) ratio and a reduction in net energy on the growth performance and nutrient digestibility on the finishing pigs. A total of 90 crossbred ([Yorkshire × Landrace] × Duroc) finishing pigs with an average initial body weight (BW) of 56.94 ± 2.43 kg were used for an 11-week feeding trial. The pigs were randomly allotted to one of three dietary treatments (six replication/treatment and five pigs/pen) in a randomized complete block design according to their BW and gender. Dietary treatments consisted of supplementation of phytase (0.05, 0.07, and 0.1% in the control, Trt1 and Trt 2 diets, respectively) maintaining the Ca/tP ratio (1.67 : 1, 1.84 : 1, and 2.19 : 1 in control, Trt1 and Trt 2 diets, respectively) and reducing the net energy by 1% in Trt1 and Trt2 diets compared with the control diet. The results showed that dietary supplementation with phytase in the energy-reduced diet had a similar (p > 0.05) effect on the BW, average daily gain, average daily feed intake, and gain/feed ratio of the finishing pigs. Also, there were no effects (p > 0.05) of treatment matrixes on the nutrient digestibility of dry matter, nitrogen calcium, phosphorus, and gross energy. In conclusion, the increase of phytase and Ca/tP ratio and the reduction of net energy in the corn/soybean meal diet resulted in comparable growth performance and nutrient digestibility of finishing pigs relative to pigs fed the control diet.

A numerical simulation on the effect of hole geometry for film cooling flow (홀 형상이 막 냉각 유동에 미치는 효과에 대한 수치 해석적 연구)

  • Lee, Jeong-Hui;Choe, Yeong-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.7
    • /
    • pp.849-861
    • /
    • 1997
  • In this study, the effect of hole geometry of the cooling system on the flow and temperature field was numerically calculated. The finite volume method was employed to discretize the governing equation based on the non-orthogonal coordinate with non-staggered variable arrangement. The standard k-.epsilon. turbulence model was used and also the predicted results were compared with the experimental data to validate numerical modeling. The predicted results showed good agreement in all cases. To analyze the effect of the discharge coefficient for slots of different length to width, the inlet chamfering and radiusing holes were considered. The discharge coefficient was increased with increment of the chamfering ratio, radiusing ratio and slot length to width and also the effect of radiusing showed better result than chamfering in all cases. In order to analyze the difference between the predicted results with plenum region and without plenum region, the velocity profiles of jet exit region for a various flow conditions were calculated. The normal velocity components of jet exit showed big difference for the low slot length to width and high blowing rate cases. To analyze the flow phenomena injected from a row of inclined holes in a real turbine blade, three dimensional flow and temperature distribution of the region including plenum, hole and cross stream with flow conditions were numerically calculated. The results have shown three-dimensional flow characteristics, such as the development of counter rotating vortices, jetting effect and low momentum region within the hole in addition to counter rotating vortex structure in the cross stream.

Hypericum Perforatum Decreased Hippocampus TNF-${\alpha}$ and Corticosterone Levels with No Effect on Kynurenine/Tryptophan Ratio in Bilateral Ovariectomized Rats

  • El-Bakly, Wesam M.;Hasanin, Amany H.
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.18 no.3
    • /
    • pp.233-239
    • /
    • 2014
  • The present study was designed to investigate the effect Hypericum Perforatum (HP), on behavioral changes, corticosterone, TNF-${\alpha}$ levels and tryptophan metabolism and disposition in bilateral ovariectomized rats compared to $17{\alpha}$-ethinylestradiol. Behavioral analysis by measuring immobility time in forced swimming test and open field test, serum and hippocampal corticosterone and TNF-${\alpha}$ along with hippocampal kynurenine/tryptophan ratio were determined in mature ovariectomized rats treated orally either by HP at three different doses 125, 250, and 500 mg/kg/day or by $17{\alpha}$-ethinylestradiol $30{\mu}g/kg/day$ for 30 days. Ovariectomized rats showed significant increase in immobility time in the forced swimming test. Along with elevation in serum and hippocampal TNF-${\alpha}$ and corticosterone levels associated with significant increase in hippocampal kynurenine/tryptophan ratio. Immobility time in the forced swimming test was decreased in rats treated by different doses of HP in a dose dependent manner and $17{\alpha}$-ethinylestradiol with no concomitant changes in the open field test. Only Rats treated with HP exhibited significant decrease in the elevated serum and hippocampal TNF-${\alpha}$ and corticosterone, which couldn't explain the associated insignificant effect on hippocampaus kynurenine/tryptophan ratio in comparison to ovariectomized untreated rats. It is concluded that increased tryptophan metabolism toward kynurenine secondary to elevated corticosterone and TNF-${\alpha}$ might be one of the pathohphysiological mechanisms that could explain depression like state observed in this rat model. Further, the observed attenuating effect of HP on TNF-${\alpha}$ and corticosterone could contribute in its antidepressant effect in this animal model by other ways than their effects on tryptophan-kynurenine metabolism pathway.

A Study of the Change of Hall Effect as a Function of the V/III Ratio in n-GaAs compound Semiconductors

  • Kim, In-Sung
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.4
    • /
    • pp.107-110
    • /
    • 2009
  • In this study, the Hall effect has been studied in n-GaAs samples characterized by V/IIl growth ratios of 25, 50 and 100 and prepared by metal organic chemical vapor deposition. For the Hall effect measurements, the grown samples were cut to a size of 1${\times}$1 cm. The measurements were carried out at room temperature, using Indium contact metal at the four corners of the samples. According to the experimental results, the Schottky effect was not ovservation. Also for the n-GaAs sample of V/Ill 100 ratio the electron drift velocity was very high.

Effect of Inlet Clearance Gap on the Performance of an Industrial Centrifugal Blower with Parallel Wall Volute

  • Hariharan, Chinnasamy;Govardhan, Mukka
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.3
    • /
    • pp.113-120
    • /
    • 2013
  • While performing numerical simulations, it is general industrial practice to neglect the clearance gap between the impeller and the inlet duct. In the present work, the effect of clearance gap on the performance of an industrial sized centrifugal blower is simulated for two volutes of width ratios and various flow coefficients. The results show that the clearance has a positive effect at low mass flow rates. This is observed in the pressure rise (1.3%) as well as in efficiency (0.7%). At higher mass flow rates, it has a negative effect with a drop in efficiency of 1% and pressure drop of about 1.4%. The effect of clearance gap on volute with higher width ratio is smaller when compared with the volute with smaller width ratio.