• 제목/요약/키워드: Effect of Operating Conditions

검색결과 811건 처리시간 0.029초

Improvement of acoustic feedback stability by bandwidth compression and expansion

  • 염동홍;안수길
    • 한국음향학회지
    • /
    • 제4권1호
    • /
    • pp.16-21
    • /
    • 1985
  • Both shifiting the input signal's frequencies by a fixed frequency and compressing the input signal's bandwidth have been known to be effective in improving the stability margin of public adress systems operating in reverberant spaces. This paper describes the effect of an alternative approach of improving the acoustic-feedback stability and yet maintaining speech inteligibility by bandwidth compression and expansion. Conditions are derived for this technizue to be realized and an experimental system has been made - up. A series of experiments has been performed in small spaces and the results have shown that more than 5dB improvement can be obtained in the stability margin.

  • PDF

MPCVD에 의해 합성된 다이아몬드 박막 특성에 대한 증착조건의 영향 (Effect of deposition on the properties of diamond thin films synthesized by Microwave Plasma Enhanced Chemical Vapor Deposition)

  • 이병수;이덕출
    • 전기학회논문지P
    • /
    • 제51권1호
    • /
    • pp.33-38
    • /
    • 2002
  • In this study, the metastable state diamond thin films have been deposited on Si substrates from methane-hydrogen and oxygen mixture using microwave plasma enhanced chemical vapor deposition (MPCVD) method. Effects in experimental parameters of MPCVD including methane concentrations, oxygen additions, operating pressure, deposition time on the growth rate and crystallinity were investigated. Diamond thin film was synthesized under the following conditions: methane concentration of 0.5%(0.5sccm)~5%(5sccm), oxygen concentration of 0~80%(2.4sccm), operating pressure of 30Torr~70Torr, deposition time of 1~32hr. SEM, XRD, and Raman spectroscopy were employed to analyze the growth rate and morphology, crystallinity and prefered growth direction, and relative amounts of diamond and non-diamond phases, respectively.

가변속 열펌프의 냉매 유량제어에 의한 난방성능 변화에 관한 실험적 연구 (An Experimental Investigation on the Variation of Heating Performance Due to the Refrigerant Flow Control in a Variable-Speed Heat Pump)

  • 김봉훈
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.746-756
    • /
    • 2001
  • An experimental study was conducted to investigated the effect of refrigerant flow control on the performance of a variable-speed heat pump operating in both cooling and heating mode. For this purpose, cooling and heating capacity, EER and refrigerant mass flow rate corresponding to an electronic valve as well as a capillary tube were measured as functions of compressor speed, length of capillary tube (or valve opening of the electronic valve), refrigerant charge, and outdoor temperature. From the comparison of experimental results, it was found that the performance variation due to the electronic valve opening became significant as the operating conditions(outdoor temperature and compressor speed) deviated from the standard condition at which heating capacity and EER were rated for the indicated capillary tube.

  • PDF

주기관 고차 관성기진력에 의한 콘테이너선 선루진동의 제어 (Control of Deckhouse Vibration of a Container Ship due to Higher Order Inertial Excitation of Main Engine)

  • 이수목;김원현;정균양
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.876-880
    • /
    • 2000
  • Vibration problem of deckhouse structure in a container vessel was investigated through the analysis and measurement. The natural frequency of deckhouse structure was found to be resonant with main engine 4th order excitations in the operating range, major sources of which were main engine inertial moment and axial thrust of the propulsion shafting system. To investigate and solve the problem, exciter test was performed to identify the vibration chracteristics of the ship structure and mechanical balancer was installed to compensate the 4th order inertial moment. Measurement results under the conditions with and without balancer operating were compared and analyzed to confirm the balancer effect. Good coincidence was found between the measurement and analysis results, which made it possible to predict the vibration problem in the earlier design stage.

  • PDF

과냉 회로를 갖는 이산화탄소 냉동시스템에 대한 성능 해석 (Performance Analysis for CO2 System with Sub-cooling loop)

  • 김진만;고성규;김무근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.723-728
    • /
    • 2007
  • In order to evaluate the performance of carbon dioxide cycle with a sub-cooling loop. a simulation system was developed to predict the steady state of $CO_2$ trans-critical cycle. Mathematical models are derived to describe the relationships between the system's coefficient of performance and other operating parameters The mathematical models are based entirely on the basic mass and energy conservation law and thermodynamic and transport properties of carbon dioxide A parametric study has been conducted in order to investigate the effect of sub-cooling loop and various operating conditions on the cycle performance. An optimal mass fraction of a refrigerant flowing through sub-cooling cycle existed for the given evaporating temperature, high pressure and air inlet temperature through gas cooler.

순환유동층에서 Solid Mass Inventory에 따른 수력학적 특성 연구 (Hydrodynamic Characteristics of Circulating Fluidized Bed in Different Mass Inventories)

  • 김은경;신동훈;황정호;이종민;김재성
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제25회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.165-172
    • /
    • 2002
  • This paper discusses hydrodynamic characteristics of cold circulating fluidized bed(CFB) in different solid mass inventories. Operating parameters of solid mass inventory, primary air and J-valve fluidizing air were varied to find out the effect on the flow fludization pattern. Experimental measurements were made in a 3m tall CFB that has 0.05m riser diameter and black silica-carbonate of particle sizes from $100{\mu}m$ to $500{\mu}m$ were employed as the bed material. The operating conditions of superficial gas velocity and J-valve fluidizing velocity were in the ranges of 1.39~3.24 m/s and 0.139~0.232 m/s respectively. The axial solid fraction and solid circulation rate of CFB were observed and compared with modelling through IEA-CFBC Model and commercial CFD code.

  • PDF

Development and Application of Distributed Multilayer On-line Monitoring System for High Voltage Vacuum Circuit Breaker

  • Mei, Fei;Mei, Jun;Zheng, Jianyong;Wang, Yiping
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.813-823
    • /
    • 2013
  • On-line monitoring system is important for high voltage vacuum circuit breakers (HVCBs) in operation condition assessment and fault diagnosis. A distributed multilayer system with client/server architecture is developed on rated voltage 10kV HVCB with spring operating mechanism. It can collect data when HVCB switches, calculate the necessary parameters, show the operation conditions and provide abundant information for fault diagnosis. Ensemble empirical mode decomposition (EEMD) is used to detect the singular point which is regarded as the contact moment. This method has been applied to on-line monitoring system successfully and its satisfactory effect has been proved through experiments. SVM and FCM are both effective methods for fault diagnosis. A combinative algorithm is designed to judge the faults of HVCB's operating mechanism. The system's precision and stability are confirmed by field tests.

월성 2,3,4호기 열수송계통의 비정상 운전 해석 (Abnormal Operation Analysis of the Wolsong 2,3,4 Heat Transport System)

  • 신정철
    • 에너지공학
    • /
    • 제25권1호
    • /
    • pp.15-22
    • /
    • 2016
  • 월성 2,3,4호기의 비정상 운전 중 열수송계통의 과도변화해석이 수행되었다. 중수로에 대한 캐나다의 규제문서인 AECB R-77 요구조건에 대한 만족성을 평가하였다. 해석 결과 여러 비정상 운전시 과도변화에 의한 원자로 모관의 최고압력값은 ASME 코드의 제한치 이내로 만족되었다. 고압시 보호장치인 LRV의 영향은 미미한 것으로 나타났다.

A Low Voltage Bandgap Current Reference with Low Dependence on Process, Power Supply, and Temperature

  • Cheon, Jimin
    • 한국정보기술학회 영문논문지
    • /
    • 제8권2호
    • /
    • pp.59-67
    • /
    • 2018
  • The minimum power supply voltage of a typical bandgap current reference (BGCR) is limited by operating temperature and input common mode range (ICMR) of a feedback amplifier. A new BGCR using a bandgap voltage generator (BGVG) is proposed to minimize the effect of temperature, supply voltage, and process variation. The BGVG is designed with proportional to absolute temperature (PTAT) characteristic, and a feedback amplifier is designed with weak-inversion transistors for low voltage operation. It is verified with a $0.18-{\mu}m$ CMOS process with five corners for MOS transistors and three corners for BJTs. The proposed circuit is superior to other reported current references under temperature variation from $-40^{\circ}C$ to $120^{\circ}C$ and power supply variation from 1.2 V to 1.8 V. The total power consumption is $126{\mu}W$ under the conditions that the power supply voltage is 1.2 V, the output current is $10{\mu}A$, and the operating temperature is $20^{\circ}C$.

$CO_2$ FCAW에서 용접조건이 Fume발생량에 미치는 영향에 관한 연구 (A Study on the Effect of Welding Conditions on Fume Generation Rate in $CO_2$ Flux Cored Arc Welding)

  • 채현병;김정한;김희남
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.87-95
    • /
    • 1998
  • The use of flux cored arc welding(FCAW) process has grown dramatically since it has been developed because of the remarkable operating characteristics and the resulting weld properties. The feature that distinguishes the FCAW process from other arc welding processes is the enclosure of fluxing ingredients within a continuously fed tubular electrode. The benefits of FCAW process are the increased productivity due to continuous wire feeding, the metallurgical effects derived from the reactions with flux, and the shapes of weld bead formed by slag. However, FCAW process causes the problem in working environment because it generates much more fume than other welding processes. Recently, the welding fume became a hot issue in the field after some welders were diagnosed as manganese toxcosis and siderosis. This study was started to investigate the characteristics of welding fume and utilize the results from the investigation to protect the welders from welding fume. As a first step, the effect of welding conditions on the fume generation rate(FGR) were investigated during FCAW process with $CO_2$ shielding. The considered welding conditions were welding current, arc voltage, travel speed, contact tube to work distance, and torch angle. The results showed that FGR was affected by all of these factors.

  • PDF