• Title/Summary/Keyword: Edge width

Search Result 465, Processing Time 0.025 seconds

Shear Layer and Wave Structure Over Partially Spanning Cavities

  • Das, Rajarshi;Kim, Heuy Dong;Kurian, Job
    • Journal of the Korean Society of Visualization
    • /
    • v.11 no.2
    • /
    • pp.46-54
    • /
    • 2013
  • Study of the wave structure and shear layer in the vicinity of a wall mounted cavity is done by time averaged colour schlieren and time resolved instantaneous shadowgraph technique in an M=1.7 flowfield. Effect of change of cavity width on flow structure is investigated by using constant length to depth (L/D) ratio cavity models with varying length to width (L/W) ratio of 0.83 to 4. The time averaged shock wave structure was observed to change with change in cavity width. Dependence of the shock angle at the leading edge on the shear layer width is also evident from the images obtained. Unsteadiness in the flow field in terms of shear layer dynamics and quasi steady nature of shock waves was evident from the images obtained during instantaneous shadowgraph experiments. Apart from the leading and trailing edge shocks, several other waves and flow features were observed. These flow features and the associated physical phenomena are discussed in details and presented in the paper.

A Camber Monitoring System of RM Zone based on Direction Selective Edge Detection Algorithm (방향 선택형 에지검출 알고리즘 기반의 RM존 캠버 모니터링 시스템)

  • Kim, Hyun-Soo;Choi, Yong Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.8
    • /
    • pp.713-717
    • /
    • 2015
  • In this paper, we propose camber monitoring system which is using on hot rolling process. In roughing mill which is one of the rolling part in hot rolling process, steel plate can be bended in width direction under the imbalance of rolling condition. This bending of steel plate in width direction is called as camber. In order to measure the camber, first, cameras which are installed over transport pathway of steel plate take pictures of whole shape of steel plate. And location value of steel plate edge is extrated from these pictures by edge detection algorithm. But, there are a lot of noises which are generated by such as water sprays, dusts, peripheral equipments in these pictures, and these noises make edge detection difficult. In order to solve this kind of problem, we developed a direction selective edge detection algorithm, and applicated in our camber monitoring system. As a result, we got stable results in spite of process noises.

Dosimetric and clinical review on the application of TOMO_edge mode (토모테라피 Edge 모드를 이용한 임상적 유용성 고찰)

  • Kim, Lizzy
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.177-182
    • /
    • 2014
  • Purpose : The goal of this study was to compare and analysis the dose distribution and treatment time between Tomotherapy planning with fixed jaw(FJ) and dynamic jaw(DJ). Materials and Methods : Seven patients were selected in the study including five common clinical cases(brain, head and neck(HN), lung, prostate, spine). 1) Helical Tomotherapy plans with FJ and DJ were generated with the same planning parameters such as Modulation factor, Pitch and Field width. 2) Tomo_edge plans with a larger field width were generated to compare to conventional HT delivery with fixed jaw. Dosimetric evaluation indices for target coverage are Dmin, Conformity index(CI) and for whole body including target are $V_{10%}$, $V_{25%}$, $V_{50%}$, $V_{75%}$ using Dose-volume histogram(DVH). Also, Treatment time and Cumulative MU were used for clinical review on Tomo_edge. Results : In case of using the same field width of Tomotherapy planning with FJ and DJ, the averaged variations were $V_{10%}$: -11.91%, $V_{25%}$: -7.6%, $V_{50%}$ :-4.75%, $V_{75%}$: -1.04%. Tomo_edge with a larger field width provides the averaged variations for target coverage: Dmin: -0.72%, CI: -1.25% and also shows the tendency of a sharp $V_{x%}$ decline in low dose area. The clinical improvements in the larger field width with DJ were observed in the treatment time, ranging from -51.21% to -15.11, and the Cumulative MU decrease, ranging from -57.74% to -15.31%. Conclusion : Target coverage achieved by FJ and DJ with the same field width has little differences. But integral doses on whole body efficiently decreased. Compared to the conventional HT delivery, Tomo_edge with a larger field width presents a little worse target coverage. However, it provides faster treatment delivery and improved cranial-caudal target dose conformity. Therefore, Tomo_edge mode is efficient in improving the treatment time and integral dose while maintaining comparable plan quality in clinic.

Edge overcoating and buildup of continuously hot-dip metallized strip (연속 용융도금 강판의 에지 과도금 및 빌드업)

  • 박정렬;전선호;박노범
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.4
    • /
    • pp.555-560
    • /
    • 1999
  • Gas wiping of continuously hot-dip galvanized coating on steel strip has generated edge overcoating and noise problems. The overcoating of zinc in the edge zone from edge to 50mm inside of the strip along its width was measured and analyzed. The overcoating is thought to occur due to the reduced impinging pressure of wiping gas onto the strip edges by the boundary effect and it can decrease by 50% or more by applying edge baffles when the baffle-to-strip distance is maintained to 20mm or less. The overcoating was compared with edgedrop of the cold-rolled steel substrate. Edge buildup mostly at the edge area 10 to be 20mm from the edge results in if the edgedrop is not sufficient enough to compensate for the overcoating to be flat on the edgedrop or/and if the overcoating is not small enough to the given edgedrop. Edge baffles can reduce effectively this type of edge buildup.

  • PDF

A Study on the Improvement of Penumbra and Dose Distribution in the Multileaf Collimator Field Edge (다엽콜리매이터(Multileaf Collimator) 조사야의 반음영 및 선량분포 개선에 대한 연구)

  • Kim CW.;Kim HN.;Lim CK.;Ra SK.;Park BS.
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.88-93
    • /
    • 1998
  • Multileaf collimator is essential equipment in conformal radiation therapy, however the use is limitted by increase of penumbra width and undulating dose distribution at the field edge. The purpose of this study is to improve the penumbra and dose distribution in the multileaf collimator field edge. Measurement were performed with X-omat V film in solid water phantom using 6MV photon beam from Siemens linear accelerator. All the measurement were made along the central axis of $5{\times}5cm,\;10{\times}10cm$ circular field for constant SSD of 100 cm. To improve the penumbra and dose distribution collimator was rotated by 15 degrees from 0 to 90 degrees (collimator rotation method) and center was shifted to the longitudinal direction by fourth of lead width (center shift method). We compare the penumbra and dose distribution at the field edge to alloy block. Dose distribution and penumbra width at the feild edge of MLC showed undulated dose pattern and increased penumbra compared with alloy block. However, in the collimator rotation method and center shift method we abtained simular results with alloy block. Through the study we expected that clinical use of MLC will be increase.

  • PDF

Study on low-k wafer engraving processes by using UV pico-second laser (Low-k 웨이퍼 레이저 인그레이빙 특성에 관한 연구)

  • Nam, Gi-Jung;Moon, Seong-Wook;Hong, Yoon-Seok;Bae, Han-Seong;Kwak, No-Heung
    • Proceedings of the Korean Society of Laser Processing Conference
    • /
    • 2006.11a
    • /
    • pp.128-132
    • /
    • 2006
  • Low-k wafer engraving process has been investigated by using UV pico-second laser with high repetition rate. Wavelength and repetition rate of laser used in this study are 355nm and 80MHz, respectively. Main parameters of low-k wafer engraving processes are laser power, work speed, assist gas flow rate, and protective coating to eliminate debris. Results show that engraving qualities of low-k layer by using UV pico-second pulse width and high repetition rate had better kerf edge and higher work speed, compared to one by conventional laser with nano-second pulse width and low repetition rate in the range of kHz. Assist gas and protective coating to eliminate debris gave effects on the quality of engraving edge. Total engraving width and depth are obtained less than $20{\mu}m$ and $10{\mu}m$ at more than 500mm/sec work speed, respectively. We believe that engraving method by using UV pico-second laser with high repetition rate is useful one to give high work speed of laser material process.

  • PDF

Design of the Anvil Shape in Sizing Press for Decrease of the Defect Generated Width Reduction (사이징 프레스에서 폭 압하 공정중 결함 저감을 위한 엔빌의 형상설계)

  • Lee, S.H.;Lee, S.J.;Lee, J.B.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.18 no.1
    • /
    • pp.52-58
    • /
    • 2009
  • Generally, a vertical rolling process is used to achieve extensive width reduction in hot strip mill. However, it is impossible to avoid the defects such as dog-bone and edge-seam defect. The sizing press process has been developed in response to the defects mentioned above. Especially, this study is carried out to investigate the deformation of slab by two-step sizing press. The deformation behavior of slab in the sizing press process is more favorable than that in conventional vertical rolling edger. The FE-simulation is applied to predict the deformation behavior of the slab. In this paper, the several causes of the asymmetrical deformation are mentioned for the purpose of understanding of the anvil shape. Load, dog-bone and edge-seam defect are discussed in width sizing process considering the anvil shape. And to reduce the problems generated at rougher mill just after sizing press, these are studied in this paper. The deformation behavior of slabs and optimum anvil shape are obtained by rigid-plastic finite element analyses and neural network.

An Investigation of Deformation Behavior of Plate Ends in Edge Rolling (후판 에지압연시 선후단부의 변형거동)

  • 천명식;황상무;이준정;김종근
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.7
    • /
    • pp.1278-1284
    • /
    • 1992
  • In plate rolling, it is desired to reduce the trimming loss by controlling the formation of defective end shapes. For this reason, edge rolling is frequently performed in the plate mill. In this paper, the effect of various process variables on the deformation of plate ends in edge rolling is examined by conducting experiments and finite element computer simulation. A focus is given to investigating the effect of edging on the width of the deformed plate trimming-free plate rolling.

Edge Detection Using Mean Difference within a Connected Bimodal Region (이분된 지역평균의 차를 이용한 경계점 검출법)

  • Jung, Moon-Jo;Shim, Young-Serk;Hwang, Chan-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1360-1363
    • /
    • 1987
  • Two edge detection methods are devised and tested. First one makes use of mean-difference between two connected regions after bimodal thresholding within a local window. It appears experimentally to provide reduced edge width maintaining good connectivity. It seems due to the use of the threshold obtained from a larger neighborhood. Second one uses additionally the gradient information to detect approximate zero crossing points of second directional derivative. This provides edges thinned nearly to one pixel width.

  • PDF

Analysis of Stepped Impedance Lowpass Filter with Coupled Open Stubs (개방스텁을 갖는 계단 임피던스 저역통과 필터의 해석)

  • 김성일;기철식;박익모;임한조
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.10
    • /
    • pp.1078-1082
    • /
    • 2002
  • In this paper, we have studied the dependence of insertion loss of a microstrip stepped impedance lowpass filter with coupled open stubs. Coupling mechanisms in the filter depend not only on the transmission line width of the filter but also the gap width of coupled open stubs and three attenuation poles are created with the proper conditions. Also edge capacitance between open stubs play an important role in having three attenuation Poles. We verify the results by obtaining [S] matrices.