• Title/Summary/Keyword: Economical replacement time

Search Result 30, Processing Time 0.03 seconds

Turbine discharge measurement case study using ASFM system (ASFM을 이용한 수차유량의 측정)

  • Kim, Eung-Tae;Jeong, Yong-Chea;Park, Jang-Won
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.49-52
    • /
    • 2006
  • should be in English, A make out an economical, reliable and easy to adoptable instrument in turbine discharge measurement was restricted from lots of it's foundational condition. Not with standing the brilliant progress in new technology of these day, useful instrument for flow measurement in turbine is still ongoing. Nowaday, the increasing importance of renewable energy makes it more important that the measuring turbine efficiency as a decision making index of old turbines' replacement. In Turbine performance diagnosis, Kwater(Korea Water Corporation) got an enough ability and decent reputation for who has invested lots of time and effort for buildup and development. In Korea as a public corporation who should take a crucial roll in Turbine business, Kwater has introduced some developed new technology for other domestic concerned one. With this writing, I'd like to introduce ASFM system as a newly developed instrument that can cope with lots restriction in discharge measurement in turbine. Kwater adopted the system in 2005, and performed 2 times of trial test. The test result was good enough to use the system as a reference test method.

  • PDF

A study on the Innovation method of Metro EMU Maintenance (도시철도 전동차 정비 이론 및 개선 방향 연구)

  • Choi, Yong-Woon
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1864-1870
    • /
    • 2007
  • The inspection periods for the metro EMU maintenances vary variously according to the countries and railway operators. And the inspection systems vary according to the safety, economical, technical aspects, and also the social environments like passengers and maintenance qualities, etc. Also, in economic point of view, maintenance requires the man power, facilities, equipments, purchasing of parts and the loss of not being in revenue service during the maintenance period. Recently, there is a tendency that the inspection periods are extended gradually owing to the increased reliabilities of the equipments and parts of EMUs. Even if it is the EMUs that are already be in service, once the inspection method is innovated, the inspection time can be reduced. The inspection management innovation scheme includes such methods as the complete module to module replacement when trouble shooting a faulty parts before putting the EMU back to revenue service, the replacements of parts in complete set unit for the heavy maintenance, the establishments of exchange periods for the wasting parts, modernization of inspection equipments, introduction of RAMS for the reliability improvement and computerization of EMU maintenance management, etc. I think it is possible to optimize the inspection scopes and periods per parts and equipments by the introduction of RAMS.

  • PDF

A Study on Efficient Simple Water Supply System in Rural Areas (농촌지역의 효율적인 간이 상수처리에 관한 연구)

  • 이홍근;백남원;백도현
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.3
    • /
    • pp.103-115
    • /
    • 1996
  • The purpose of this study was to establish acceptable criteria for the design of simple water treatment plant in rural areas. To develop efficient simple water treatment methods for rural areas, water quality in the study areas was investigated and rapid and slow filtrations in pilot-scale were tested under various conditions. The main results of this study are as follows. It was found that the water qualities of the study areas exceed the drinking water standards, which implies that some treatments are required in rural areas. Treatment efficiencies of both rapid sand and dual-media (sand and anthracite) filtration without pre-treatment such as flocculation and sedimentation are very low, which were turned out to be unadequate for the rural areas. Treatment efficiencies of both vertical and horizontal slow filtration without chlorination are very high for consumed $KMnO_4, NH_3-N, NO_3-N$, turbidity, and very low for coliform and bacteria. Treatment efficiencies of both vertical and horizontal slow filtration with chlorination are very high over the most pollutants. A slow filtration with chlorination is efficient for the rural areas. An adequate depth of sand layer is over 60 cm. A horizontal filtration is more economical than a vertical filtration. A horizontal filtration can be operated for a relatively long periods of time without sand washing or replacement because clogging is removed by simple back-washing.

  • PDF

Condition evaluation method of terminal station facilities for hydrological observation system (수문관측시스템 단말국 설비 성능분석을 통한 상태평가 방안)

  • Hong, Sung-taek;Kim, Jun-hee;Kim, Il-han;Lee, Ho-hyun;Choi, Ki-sun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.181-183
    • /
    • 2013
  • In case of hydrological observation system, Life time of facilities is different with operating environment and frequency of use. So, the durable year of the facilities is only considered to replace the facilities at present. Thus, system management is needed economical assesment based on condition evaluation through performance analysis of facilities. This research makes a proposal for scientific condition evaluation table through physical assessment, performance analysis assessment, durable years assessment about satellite communication facilities being used in K-water. Consequentially, reasonable replacement plan is established for satellite communication facilities.

  • PDF

Condition Evaluation Method of Satellite Communication Facilities for Hydrological Observation (수문관측용 위성통신설비 상태평가 기법)

  • Shin, Gang-Wook;Hong, Sung-Taek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.3030-3037
    • /
    • 2013
  • Life time of facilities is different In case of operating environment and frequency of use. So, the durable year of the facilities is only considered to replace the facilities at present. Thus, system management is needed economical assesment based on condition evaluation through performance analysis of facilities. This research makes a proposal for scientific condition evaluation table through physical assessment, performance analysis assessment, durable years assessment about satellite communication facilities being used in K-water. Consequentially, reasonable replacement plan is established for satellite communication facilities.

Economic Analysis with Development of Rapid Setting Alumina-based Binder for Road Repair (알루미나계열 속경성 도로 보수재료 개발에 따른 경제성 분석)

  • Yang, Hee-Jun;Yang, Min-Jae;Hong, Sung-In;Ann, Ki-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.1
    • /
    • pp.3-10
    • /
    • 2017
  • In case of Korea highways, about 60% of highways are paved by concrete and more than 50% of them were repaired due to reduction in required performance such as damage in pave or joint and delamination of cover pavement. However, repairing old material in such structure generally costs a lot of money and induces difficulty in maintenance. Thus, enhanced material for ensuring economic efficiency should be developed. The present study designed concrete mixtures with 3 levels of replacement using OPC (0, 10, 20%) in calcium aluminate cement and to evaluate material performance for load pavement, experimental works for setting time, compressive strength and flexural strength were carried out on those materials. As a result, 20% replacement for OPC was determined as an optimized material in terms of required physical performance and its unit price. Moreover, to determine cost in load pavement economy analysis using a program (CA4PRS) was conducted with widely used paving materials. Result showed that application for 20% replacement for OPC was the most efficient in economical aspect, arising from 4.052 and 1.577 billion won for total construction and user cost, respectively.

Study of Personal Emergency Response System among Community Residing Elderly (119무선페이징의 이용실태에 관한 연구 - 일 지역을 중심으로 -)

  • Kwon, Hay-Rran;Jung, Ji-Yun;Choi, Gil-Soon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.11 no.2
    • /
    • pp.87-101
    • /
    • 2007
  • Health and disease related characteristics of 226 selected by systematic sampling from 452 personal emergency response system(PERS) beneficiaries and actual conditions of using PERS by them are as follows. Over 86% of PERS beneficiaries have not good health conditions and 70.7% of them have chronic diseases. On social supports family was highest as 52.2% and cases having social workers' assistance were 15.2%, but 53 as 23.7% had not visit or call from anyone and showed very low social supports. 86.2% was given PERS within 3years and 79.1% had it by the recommendation from related agencies and 4.0% was by their demand. On wearing it, 78.3% didn't bring it with them and 92% of them answered they were not sick and then it was found that they didn't use it because they had not special emergency. On satisfaction with paging system's operation, 81.3% answered they were satisfied with it, 48.8% used it for 'acute and emergency diseases' and 29.3% called ambulance for 'appointed medical treatment'. Time required for ambulance to arrive at the field was within 10 min. in 87.8% and after 10 min. in 12.2% and emergency service for beneficiaries by fire service was very good. On satisfaction with use of PERS, 85.4% were satisfied with it, 81.9% who requested repair or replacement of radio paging got it back after one or two days of their request and they answered they were satisfied with A/S. 45.5% answered they powered off it because 'they didn't use it' and 12.1% had 'economical reason of phone charge'.

  • PDF

Machinability investigation and sustainability assessment in FDHT with coated ceramic tool

  • Panda, Asutosh;Das, Sudhansu Ranjan;Dhupal, Debabrata
    • Steel and Composite Structures
    • /
    • v.34 no.5
    • /
    • pp.681-698
    • /
    • 2020
  • The paper addresses contribution to the modeling and optimization of major machinability parameters (cutting force, surface roughness, and tool wear) in finish dry hard turning (FDHT) for machinability evaluation of hardened AISI grade die steel D3 with PVD-TiN coated (Al2O3-TiCN) mixed ceramic tool insert. The turning trials are performed based on Taguchi's L18 orthogonal array design of experiments for the development of regression model as well as adequate model prediction by considering tool approach angle, nose radius, cutting speed, feed rate, and depth of cut as major machining parameters. The models or correlations are developed by employing multiple regression analysis (MRA). In addition, statistical technique (response surface methodology) followed by computational approaches (genetic algorithm and particle swarm optimization) have been employed for multiple response optimization. Thereafter, the effectiveness of proposed three (RSM, GA, PSO) optimization techniques are evaluated by confirmation test and subsequently the best optimization results have been used for estimation of energy consumption which includes savings of carbon footprint towards green machining and for tool life estimation followed by cost analysis to justify the economic feasibility of PVD-TiN coated Al2O3+TiCN mixed ceramic tool in FDHT operation. Finally, estimation of energy savings, economic analysis, and sustainability assessment are performed by employing carbon footprint analysis, Gilbert approach, and Pugh matrix, respectively. Novelty aspects, the present work: (i) contributes to practical industrial application of finish hard turning for the shaft and die makers to select the optimum cutting conditions in a range of hardness of 45-60 HRC, (ii) demonstrates the replacement of expensive, time-consuming conventional cylindrical grinding process and proposes the alternative of costlier CBN tool by utilizing ceramic tool in hard turning processes considering technological, economical and ecological aspects, which are helpful and efficient from industrial point of view, (iii) provides environment friendliness, cleaner production for machining of hardened steels, (iv) helps to improve the desirable machinability characteristics, and (v) serves as a knowledge for the development of a common language for sustainable manufacturing in both research field and industrial practice.

Characterization of Toluene Vapor Removal Efficiency Using Alnus Firma Fruit in a Biological Treatment Process (오리나무 열매를 이용한 생물처리장치에서의 톨루엔 가스 처리효율 특성)

  • 공남식;차수길;서정윤
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.689-699
    • /
    • 2003
  • This study was to examine characteristics of treating toluene vapor, which gets to be problematic due to its harmful carcinogenicity and mass generation from various sources, through a biological treatment facility which is environment-friendly and adopts a high-efficient and low-cost clean technology. In order to identify whether Alnus Firma Fruit (AFF) can be used as a media for a bioreactor, its utility and basic operating factors, a study was conducted on pressure drop, supply of nutrient substances and retention time which are operating factors of a biofilter, and eliminating characteristics were compared between AFF and the conventional biological activatedcarbon (BAC) widely used as filter media. In the case of AFF, the initial microbial deposits was 2.3${\times}$10$^{7}$ CFU/g dry AFF, which represents the initial microbial density higher than the case of BAC showing 5.5${\times}$10$^{6}$ CFU/g dry BAC And it took about 2 weeks to acclimate until its eliminating rate got to be increased over 90%. As a result of comparing pressure loss taking place with the lapse of time between BAC and AFF, after 130 days passed at SV 25h$^{-1}$ , BAC showed that its eliminating efficiency had a tendency to drop greatly due to a great pressure loss (0.53\longrightarrow54.7 mm$H_2O$/m) caused by an excess of biomass as accumulated. On the other hand. AFF showed that the pressure drop was 0.53 mm$H_2O$/m, about 2 times as much as the initial pressure loss of 0.4 mm$H_2O$/m, which represents no great change in the pressure loss, and its eliminating efficiency was also shown to be continuously high. Therefore, when AFF was used as a filler for a biological treatment facility, a biological filter enabling improvement of the purifying efficiency to be promoted could be provided, and moreover, the pressure loss was so small that the filler replacement cycle or the back flushing cycle could be extended. So, even in terms of the operating cost, it was identified to be an economical filler When an inorganic material was used as a filler, the biofilters performance acted sensitively on whether nutrient substances were supplied or not. In the case of AFF with low adsorptivity, addition of ethyl-alcohol increased the solubility of toluene, and consequently, biodegradation got to be actively made by microbes, and thus, its eliminating rate could be increased. As the flow velocity and the inflow concentration got to be more increased, its eliminating rate got to be lower, and particularly, an increase in the flow velocity made its eliminating rate drop more greatly than an increase in the concentration.

A Study on the Estimation for the Guaranteed Strength and Construction Quality of the Combined High Flowing Concrete in Slurry Wall (지하연속벽용 병용계 고유동 콘크리트의 시공 품질 및 보증강도 평가에 관한 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.811-817
    • /
    • 2006
  • The primary purpose of this study is to estimate the guaranteed strength and construction quality of the combined high flowing concrete which is used in the slurry wall of underground LNG storage tank. The required compressive strength of this type of concrete become generally known as a non economical value because it is applied the high addition factor for variation coefficients and low reduction factor under water concrete. Therefore, after estimation of the construction quality and guaranteed strength in actual site work, this study is to propose a suitable equation to calculate the required compressive strength in order to improve its difference. Application results in actual site work are shown as followings. The optimum nix design proportion is selected that has water-cement ratio 51%, sand-aggregate ratio 48.8%, and replacement ratio 42.6% of lime stone powder by cement weight. Test results of slump flow as construction quality give average 616~634mm. 500mm flowing time and air content are satisfied with specifications in the rage of 6.3 seconds and 4.0% respectively. Results of strength test by standard curing mold show that average compressive strength is 49.9MPa, standard deviation and variation coefficients are low as 1.66MPa and 3.36%. Also test results by cored cylinder show that average compressive strength is 66.4MPa, standard deviation and variation coefficients are low as 3.64MPa and 5.48%. The guaranteed strength ratio between standard curing mold and cored cylinder show 1.23 and 1.32 in the flanks. It is shown that applied addition factor for variation coefficients and reduction factor under water concrete to calculate the required compressive strength is proved very conservative. Therefore, based on these results, it is proposed new equation having variation coefficients 7%, addition factor 1.13 and reduction factor 0.98 under water connote.