• Title/Summary/Keyword: Ecological Building

Search Result 842, Processing Time 0.023 seconds

A Study on the comparison of Infill Technology between Korea long life Apartment Mock up House and Japan KSI experimental House (국내 장수명 공동주택 Mock-up House와 일본 KSI 실험주택 인필 요소기술 비교 연구)

  • Choi, Young Ho;Kim, Shin;Kim, Sung Wan
    • KIEAE Journal
    • /
    • v.8 no.4
    • /
    • pp.63-69
    • /
    • 2008
  • The thesis is a comparative analysis of Infill Technologies between Korea's long-life Mock-up House, a study driven by 'Durability and Flexibility of Long-life Housing Technology Development' of R&D, and Japan's KSI experimental house, the major example of Japan's long-llfe housing. In terms of the domestic Mock-up House, a system of building the floor first was applied. The floor material of each housing unit required a development of dry heating component that is partially substitutable in order to avoid conflict with the finishing. Also, a development of a floor system that can counteract against the construction inaccuracy was required. In the Case of an outer wall, need to make the wall with the chassis. In the case of ceiling, need to develop the double ceiling system which is good for sound insulation. Also, in comparison to KSI experimental house in Japan, it would require to develop a wiring system of the ceiling which can react to the movement of the wall. Especially, to assure the flexible nature of an internal wall, it would desperately require the research and development of the products related to components and flexible system of mechanical/electrical/communication parts as well as supporting institutionalized system for this development. Furthermore, for KSI experimental house in Japan, it would be necessary to formulate a construction manual as well as a systematic and practical planning guide to invent a new interface rule which will secure simplicity of assembling, dismantling, installation and replacement of architectural components for which research development is quite insignificant at the moment. This effort will have to continue to give a solid direction for better application of such reference manual during construction and development of long life span apartment by public sector as well as private corporations.

Deducing environmentally conscious factors for apartment complex planning and weight evaluation (환경요소를 고려한 공동주택 단지계획요소 도출 및 가중치 평가)

  • Jung, Suk-Jin;Seo, Jung-Bum;Yoon, Seong-Hwan
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.51-56
    • /
    • 2016
  • Purpose: As declines in the quality of residential environments occur, such as urban heat island effect, tropical night phenomenon, and violations of right to light and privacy due to urban densification and high rise building, these problems are emerging as social issues. In order to improve these issues, design factors which consider environmental aspects must be selected when planning apartment complexes, and ways to reflect them in the planning phase must be explored. Method: In this study, the analytical hierarchy process(AHP) was used to deduce design factors that considered environmental elements during the planning of apartment complexes. Furthermore, the priority and weight for each evaluation index were assessed. The objective was to propose a guideline for planning apartment complexes by finding the best solution for each evaluation index using complex weight values. Result: Floor area ratio was selected as the most important evaluation criterion in the environmentally conscious evaluation index for apartment complex planning. The shape and placement of skylights were selected as the most important evaluation criteria in the sunshine environment for a pleasant residential environment. Ground surface cover design was selected as the most important criterion in the outdoor thermal environment index for improving the microclimate within cities and apartment complexes. Thus, the results of this study can serve as an investigation guideline that concerns policy and regulations, and as reference data that can be used in planning apartment complexes.

The Improvement of Design Inducement Incentive on Permitted Floor Area Ratio in District Detailed Plan -Focused on the Design Inducement Incentive items and parameters in formula- (서울시 지구단위계획 구역내 건축물의 계획유도를 위한 허용용적률 인센티브 개선방안 - 항목 및 세부계획기준의 계수를 중심으로)

  • Rim, Eun Young;Lee, Seung Joo
    • KIEAE Journal
    • /
    • v.17 no.4
    • /
    • pp.49-57
    • /
    • 2017
  • Purpose: Design inducement incentive item and formula on permitted floor area ratio in district detailed plan have been improved to reflect the actual application of guidelines and the social needs of city and architecture. However, the current guideline has a limit to realize the purpose of the plan. This study proposes improvement of the items and parameters in formula. Method: This study analyzed the district detailed planning guidelines since 2000 and the cases of general type district unit plan. In order to propose improved items and parameters, planing purposes and present parameters were compared and analyzed. Result: Items of guidelines have been changed according to public needs. High necessity items were applied to large parameters, and these items have been changed as the guideline changes. Diversity of items depended on regional characteristics, and parameters were more flexible than items for most cases. The purposes of plans, parameters and items were analyzed and it revealed four items needed improvement; the inducement of the limited building line, the improvement of the pedestrian and street environment, the necessity of the open space, and strengthening of the regional agreement. For improvement, this study added items and improved the relevance between items and sub-items. The parameters were improved by considering the importance, feasibility and comparing them with each other. Simulated result confirmed that proposed guideline is appropriate to operate, and also characteristics of area encourage to operate it more flexible.

Annual Energy Performance Evaluation of Zero Energy House Using Metering Data (실측데이터를 이용한 에너지제로주택의 연간 에너지성능평가)

  • Lim, Hee-Won;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.113-119
    • /
    • 2016
  • Purpose: In this study, we evaluate the annual energy performance of the detached house which was designed with the aim of zero energy. Method: The experimental house which was constructed in Gonju Chungnam in 2013, is the single family detached house of light weight wood frame with $100m^2$ of heating area. Thermal transmittance of roof (by ISO 10211) and building external walls are designed as $0.10W/m^2K$ and $0.14W/m^2$ respectively and low-e coating vacuum window glazing with PVC frame was installed. Also grid connected PV system and natural-circulation solar water heater was applied and 6kWp capacity of photovoltaic module was installed in pitched roof and $5m^2$ of solar collector in vertical wall facing the south. We analyzed the 2014 annual data of the detached house in which residents were actually living, measured though web-based remote monitoring system. Result: First, as a result, total annual energy consumption and energy production (PV generation and solar hot water) are 7,919kWh and 7,689kWh respectively and the rate of energy independence is 97.1% which is almost close to the zero energy. Second, plug load and hot water of energy consumption by category showed the highest numbers each with 33% and 31%, with following space heating 24%, electric cooker 8%, lighting 3% in order. Hot water supply is relatively higher than space heating because high insulation makes it decreased.

Repair Accumulation Cost for the Long-Term Repair Plan in Multifamily Housing Using the Forecasting Model of the Repair Cost (공종별 수선비용 추계모델을 활용한 공동주택 장기수선충당금 적립금액 산정)

  • Lee, Kang-Hee;Chae, Chang-U
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.137-143
    • /
    • 2016
  • Purpose: Apartment housing should conduct a cyclic repair to keep and maintain the building performance since they are constructed. Therefore, the repair plan would be provided for long term period which explains the repair time, items and repair cost. Residents of apartment housing are responsible to pay for the repair activities. For repair cost, residents would reserve the money for repair little by little continuously until the required repair time because the repair cost takes a big burden for residents and lots of money a time. But, there is no systematic approach to provide the long term repair cost because it is no proper forecast of the repair cost to the upcoming repair time. In this study, it aimed at providing the monthly accumulation of the long term repair cost with the survey data in Seoul. Method: For these, the surveyed data are classified into 6 categories and number of data are 1,918. In addition, it developed the repair cost model for the 24 repair works and the cumulation function which is reflected with the each cost model. Result: This study are shown as follows : First, among the various estimation for the repair cost, the power function has a goodness of fit in statistics. Second, the monthly accumulation would be 12,840 won/household in size of $100,000m^2$ management area and $81.7won/m^2$ in size of the 1,000 household number during 40 years.

Development of Impact Table and optimum combination dedication module for green-remodeling advance business value assessment

  • Choi, Jun-Woo;Kim, Gyoung-Rok;Ko, Jung-Lim;Shin, Jee-Woong;Lee, Keon-Ho
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.5-12
    • /
    • 2016
  • Purpose: In case of existing building, A lot of attempts are being made like changing thermal system or using high efficiency products to decrease energy load and increase energy efficiency. However, (1) Absence of systemed database of green-remodeling technology and products. (2) Absence of comparative analysis system and qualitative/quantitative evaluation method of energy performance and energy reduction cost. (3) Existing remodeling was very hard to access for non-experts. So, in this paper, the authors developed data base for green-remodeling(Impact Table A, Impact Table B) and optimum combination dedication tool for user convenience. Accordingly, purpose of this paper validate usefulness of Impact Table and optimum alternative dedication tool. Method: For validate the usefulness of Impact Table and optimum combination dedication tool, the authors selected five test model office buildings. Next, through research investigation, the authors diagnosed the present state of buildings. In base of diagnosis results, select technologies for remodeling by qualitative comparison (Impact Table A). Next, evaluate quantitative price and performance technologies that selected in Impact Table A (Impact Table B). Lastly, through final evaluation of Impact Taba A and Impact Table B, determine the direction of the green-remodeling. Result: Impact Table and optimum combination dedication tool can use relative indicator for green-remodeling, especially through ROI by detail field.

A study on Actual Conditions Analysis for Regeneration of High-rise and High-density Apartment in the 1st period New Town (1기 신도시 고층고밀 아파트단지의 재생을 위한 개발현황 분석에 관한 연구 - 분당신도시를 중심으로 -)

  • Cho, Sung Heui;Lee, Tae Kyung;Oh, Deog Seong
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.17-26
    • /
    • 2009
  • High-rise and high-density apartment complexes have been built and supplied on a large scale in the 1st period New Town of metropolitan areas since the late 1980s. Recently it has become necessary to improve those apartment complexes which have blight problems for aging more than about 20 years accompanying simultaneity and a large scale. The purpose of this study is to analyze actual conditions of high-rise and high-density apartments in a view of sustainable regeneration. The contents and methods of this study are as follows. First, the concept of high-rise and high-density in domestic apartment developments were identified through review of literature and the law. Second, development conditions of Bundang new town and 1st period new town were studied. Third, the evelopment conditions of high-rise and high-density apartments in cases of 6 apartment complexes were analyzed from points of view of sustainable development by literature review and a field study. The results of this study are as follows. First, high-density range in domestic apartments can be conceptualized as 600 persons/ha. High-rise range in domestic apartments can be onceptualized as more than 11 stories under 30 stories. Second, characteristics and subjects based on actual conditions analysis could suggest on physio-environmental aspect and socio-economic aspect. Major characteristics and subjects of the physio-environmental aspect were 1.satisfaction of convenient facilities and public transportation service, 2.shortage of parking space, 3.uniform & blight of community facilities, 4.uniformed building layout, and 5.uniform pattern of unit plan and low flexibility by the bearing wall structure. And those of the socio-economical aspect were 1.satisfaction of current community, 2.increase and diversity of needs of the elderly by socio-demography change, 3.improvement of size and method of apartment complex development and 4.raising of economic-sufficiency.

A Multiplex Housing Energy Conservation Strategy through Combining Insulation Standard Based Green Roof Systems and Passive Design Elements

  • Son, Hyeongmin;Park, Dong Yoon;Chang, Seongju
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.31-38
    • /
    • 2014
  • Recently, the coverage of urban forests has been rapidly decreasing as the cities are created and expanding. Consequently, there arise urban problems such as heat island effect, urban flooding, urban desertification and so on. In this context, green roof systems is considered to be an efficient alternative to deal with these problems. However, it is difficult to apply green roof to new buildings since the majority of the buildings in cities are already constructed and the demand for new building constructions is not high enough. Therefore, it should be considered to apply green roof system to existing buildings for resolving various problems. This study evaluates heating and cooling energy consumption based on the combination of passive design factors such as wall, roof, window insulation in addition to a green roof system applied to an existing house by using an energy simulation program. Total 8 potential improvement cases are developed. Each case is applied to the same house with different insulation standard for simulations. Through the analysis of the simulated cases with the chosen test house, it is confirmed that heating energy consumption decreases as improvement cases are applied, but cooling energy consumption is relatively not much affected by each improvement case. In addition, when each improvement case is applied to already highly insulated house, the effect of thermal energy improvement decreases while the same improvement that is applied to the case with low insulated house tends to yield higher improvement rate.

Annual energy yield prediction of building added PV system depending on the installation angle and the location in Korea (건물적용 태양광발전시스템의 국내 지역에 따른 설치각도별 연간 전력생산량 예측에 관한 연구)

  • Kim, Dong Su;Shin, U Cheol;Yoon, Jong Ho
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.67-74
    • /
    • 2014
  • There have distinctly been no the installation criteria and maintenance management of BIPV systems, although the BIPV market is consistently going on increasing. In addition, consideration of the BIPV generation quantity which has been installed at several diverse places is currently almost behind within region in Korea. Therefore, the main aim of this study is to evaluate the BIPV generation and to be base data of reducing rate depending on regional installation angles using PVpro which was verified by measured data. Various conditions were an angle of inclination and azimuth under six major cities: Seoul, Daejeon, Daegu, Busan, Gwangju, Jeju-si for the BIPV system generation analysis. As the results, Seoul showed the lowest BIPV generation: 1,054kWh/kWp.year, and Jeju-si have 5percent more generation: 1,108.0kWh/kWp.year than Seoul on horizontal plane. Gwangju and Daejeon turned out to have similar generation of result, and Busan showed the highest generation: 1,193.5kWh/kWp.year, which was increased by over 13percent from Seoul on horizontal plane. Another result, decreasing rate of BIPV generation depending on regional included angle indicate that the best position was located on azimuth: $0^{\circ}$(The south side) following the horizontal position(an angle of inclination: $30^{\circ}$). And the direction on a south vertical position(azimuth: $0^{\circ}$, an angle of inclination: $90^{\circ}$) then turned out reducing rate about 40percent compared with the best one. Therefore, these results would be used to identify the installation angle of the BIPV module as an appropriate position.

Temperature Monitoring of Vegetation Models for the Extensive Green Roof (관리조방형 옥상녹화의 식재모델별 표면온도 모니터링)

  • Youn, Hee-Jung;Jang, Seong-Wan;Lee, Eun-Heui
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.89-96
    • /
    • 2013
  • Green roofs can reduce surface water runoff, provide a habitat for wildlife moderate the urban heat island effect, improve building insulation and energy efficiency, improve the air quality, create aesthetic and amenity value, and preserve the roof's waterproofing. Green roofs are mainly divided into three types : intensive, simple-intensive, and extensive. Especially, extensive roof environment is a harsh one for plant growth; limited water availability, wide temperature fluctuations, high exposure to wind and solar radiation create highly stressed environment. This study, aimed at extensive green roof, was carried out on the rooftop of the library at Seoul Women's Univ. from October to November, 2012 and from March to August, 2013. To suggest the most effective vegetation model for biodiversity and heat island mitigation, surface temperatures were monitored by each vegetation model. We found that herbaceous plants of Aster sphathulifolius, Aceriphyllum rossii and Belamcanda chinensis, shrub of Syringa patula 'Miss Kim', Thymus quinquecostatus var. japonica, Sedum species can mixing each other. Among them, the vegetation models including Sedum takesimense, Aster sphathulifolius, Thymus quinquecostatus var. japonica was more effective on the surface temperature mitigation, because the species have the tolerance and high ratio of covering, and also in water. Especially, in the treatment of bark mulching, they helped to increase the temperature of vegetation models. In the case of summer, temperature mitigation of vegetation models were no significant difference among vegetation types. Compared to surface temperature of June, July and August were apparent impact of temperature mitigation, it shows that temperature mitigation are strongly influenced by substrate water content.