• 제목/요약/키워드: Ecological Architectural Design

검색결과 192건 처리시간 0.019초

자연채광 요소기술 도출을 위한 창호시스템과 건물요소와의 통합화에 관한 연구 (A Study on Integration of Pre-manufactured Window Systems with Conventional Building Design Elements)

  • 김정태;정인영;정유근
    • KIEAE Journal
    • /
    • 제2권2호
    • /
    • pp.15-22
    • /
    • 2002
  • Importation of mass production of building elements with standardization are vital way for environment-friendly architectural planning, which it makes the lifespan of a building longer than normal with easier maintenance and remodeling. The advantage might be magnified here in Korea since typical types of apartment house are dominated in our construction market. For the purpose, a series of pre-manufactured window systems is one of the optimal elements to be prototype building modules. In the design process of the system windows, lots of consideration should be involved and they include aesthetics, thermal performance, noise reduction, airtightness, and so forth. A real survey on the ready-made window systems has been performed and its optical issue related to luminous peculiarity is what is of major interest in this study. In addition, technical review on more advanced window products and their adaptable potential for the integration with fundamental architectural design elements were carried out.

Sensitive analysis of design factor for the optimum design of PVT system

  • Jeong, Yong-Dae;Nam, Yujin
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.5-11
    • /
    • 2015
  • Purpose: Recently, renewable energy system has been widely used to reduce the energy consumption and CO2 emission of building. A photovoltaic/thermal(PVT) system is a kind of efficient energy uses, which is combined with photovoltaic module and solar thermal collector. PVT system removes heat from PV module by through thermal fluid to raise the performance efficiency of the PV system. However, though PVT system has the merit of the improved efficiency in theoretical approach, there have been few performance analysis for PVT system using the dynamic energy simulation. In this study, in order to establish the optimum design method of this system, simulation was conducted by using individual system modules. Method: For the dynamic simulation, TRNSYS17 was used and local weather data was utilized. Furthermore, the system performance in various installation condition was calculated by case studies. Result: As a result, the amount of electric generation and heat production in each case was found by the simulation. The gap of system performance was also evident according to the installation condition.

소규모 공공건축물의 디자인 지표 개발에 관한 연구 (A Study on the Development of Architectural Design Indicator for Small Public Building)

  • 류수훈
    • KIEAE Journal
    • /
    • 제13권1호
    • /
    • pp.83-92
    • /
    • 2013
  • Public buildings as a public space of the community have a close relationship with local residents and urban space. Public buildings are not a simple role as office space, but closely related to the life of the local residents. In addition, a variety of approaches, spatial, and program elements should be considered. Rising awareness for public buildings recently, aspect of design also has began to be interested. Small building is a public building that can actively cope with the social and economic environment in the rapid change. However, small building is lacking the design consideration according to the scale and economics. This paper is to present the Design Indicator that can be used to create 'small public buildings' that has been alienated from the large public buildings design development. This is intended to derive and utilize the design categories and design detail indicator of small public buildings. There are composition of design categories and design detail indicator of developed small public buildings. Design categories have developed six such as Public and Harmony, Access, Landscape Design, Space, Sustainable Design, Technique and Performance. Design Detail indicator of Small public buildings have developed all 24. Presented Design Categories and detail indicator are composed of design indicator available in all areas of design evaluation and review that includes design, function, environment, and technology of public buildings. And it is possible to apply with small public buildings in all purpose.

A Study of the Ecological Perspectives in Traditional Korean Homes

  • Hong Hyung-Ock;Rhee Kyung-Hee;Kim Dae-Nyun
    • International Journal of Human Ecology
    • /
    • 제2권1호
    • /
    • pp.123-134
    • /
    • 2001
  • The purpose of this study is to reveal the kind of traditional perspectives we can use from the past to create a sustainable society for the future and to contribute to the growing interest in, and concern for, environmentally-sound designs. Such perspectives include ways to sustain naturalistic aesthetic views, elements of architectural design, and ideas for traditional lifestyles. Architecture that used these methods would contribute to a more ecologically sensitive view of man's place within the natural environment. This research was conducted by way of literature reviews; the objects of study were physically extant traditional housing, the composition of the traditional village, and traditional lifestyles. The results of this study indicate that the ecological characteristics of traditional Korean homes originated from a holistic conception of society and nature; this holistic conception has been found lacking in our more modern, western influenced homes. In the past, in order to leave an unpolluted or even healthier natural environment to descendents, it was essential to apply ecological principles. Villages harmonized with nature and houses were designed to utilize sunlight and wind. Their natural construction promoted consciousness of human beings and their symbiotic relationship with nature.

  • PDF

생태학적 원리를 적용하여 창조된 환경림에서 확인된 복원 효과 (Restoration Effects Confirmed in the Environmental Forests Created on the Bases of Ecological Principles)

  • 이창석;이안나
    • 환경생물
    • /
    • 제22권1호
    • /
    • pp.220-226
    • /
    • 2004
  • 경기도 시흥시 정왕동 시화공업단지 내 주식회사 진도종합건설 시화소각장 주변을 생태적으로 건전하게 유지하기 위한 수단으로 생태적 설계에 바탕을 두고 복원사업을 실시하였고, 서울시 노원구의 수락산에 인공 조림된 아까시나무 임분을 복원생태학의 원리에 바탕을 두고 관리하여 그 효과를 평가하였다. 생태학적으로 창조된 숲은 조경 방법을 적용하여 조성된 숲과 비교하여 주변의 자연림과 더 유사한 종 조성을 나타내었고, 종 다양성도 높아 생태적 복원의 효과가 확인되었다. 생태학적 원리를 적용하여 관리된 아까시나무 임분은 그러한 관리없이 방치된 것과 비교하여 인근의 자연림과 더 유사한 종 조성을 나타내었고, 종 다양성도 높아 여기서도 복원의 효과를 확인할 수 있었다. 그러나 이러한 생태적 복원은 사업시행자 및 감독자의 전문성 결여, 생태적 특성이 반영되지 않은 건축조례, 묘목의 부재 등 여러 가지 현실적 문제점을 드러내었다. 본 연구는 이러한 문제를 해결하기 위한 대안으로 건축조례의 개선을 포함하여 해당지역의 자연환경에 토대를 둔 식재 지침 마련, 묘목의 준비 및 국민의 의식 수준을 향상시키기 위한 환경교육의 필요성을 제시하였다.

반사율에 따른 광선반 채광 성능평가 연구 - 주거공간을 중심으로 - (Daylighting Performance Evaluation of Light-shelf according to the Reflectivity - Focused on the Residing space -)

  • 허도연;이행우;서장후;김용성
    • KIEAE Journal
    • /
    • 제15권3호
    • /
    • pp.49-56
    • /
    • 2015
  • Purpose: Due to recent increase on energy consumption for light in building, many studies to mitigate this issue have been conducted. Various researches have been carried out to suggest light shelf as one of the solutions, but researches for its reflectivity is very few. In fact, existing research on light shelf shows that utilizing more than 90% of high-illumination materials causes imbalance of glare and illuminance. Method: Therefore this research aimed to evaluate the performance of light shelves depending on reflectivity and to identify proper solution through test-bed. Result: The results are following: 1) Increased reflectivity generally contributed to increase of indoor illuminance but degrade uniformity factor related with indoor comfort of light environment. 2) The $0^{\circ}fixed$ light shelf with 75% of reflectivity and width of 300mm and 40mm appeared to consume more energy than other shelves. Therefore, it is analyzed as unsuitable. 3) This research was conducted by calculating appropriate angle of light shelf around winter and summer solstices and vernal/autumnal equinox. Based on this, performance evaluation was undertaken depending on reflectivity of movable light shelf, which is activated by external sources and can be applied with lower reflectivity than fixed shelf. However, one exception was a movable shelf with width of 600mm that increased light energy consumption when 75% of reflectivity was applied. 4) Performance evaluation of fixed and movable light shelf showed that the shelf with 80% of reflectivity came up with suitable results, but 75% of reflectivity may be applied depending on the width and angle of the shelf. This research is meaningful in that estimation of appropriate reflectivity of light shelf can resolve the glare problem and improve light environment, and further research would be desirable under more diverse conditions to identify proper solution.

Performance Evaluation of Energy Reduction of Light Shelf Applying Punching Plate

  • Choi, Yuchang;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.5-13
    • /
    • 2014
  • Various studies on lighting energy savings are conducted, given that lighting energy consumption accounts 23.5% of building energy consumption. Especially, external type light shelf's efficiency is acknowledged; however, its application is limited in Korea, where high rise building ratio is high, due to high wind pressure. This study delves into natural lighting system to cope with wind pressure, and proposes the punching plate-installed light shelf. This study actually draws lighting energy output, according to whether the punching plate is applied through the test-bed, and verifies the effectiveness of the punching plate-installed light shelf. The conclusion is presented below: First) The result of performance evaluation of light shelf with the punching plate in winter solstice showed that the awning area decreased as the opening ratio increased so that the indoor distributed illumination tended to increase, and $-40^{\circ}$ which was advantageous for awning was determined as the proper angle. Second) The light shelf with the punching plate in spring/autumn equinox shows improved lighting according to the angle, and the appropriate angle of light shelf with the punching plate has increased to $15^{\circ}$ and $20^{\circ}$ according to the opening ratio in comparison to $5^{\circ}C$ which is the appropriate angle of light shelf with no punching plate due to the reflection area reduced by the reflecting plate with holes. Third) The result of performance evaluation of light shelf with the punching plate in summer solstice showed that the lighting performance tended to decrease as the opening ratio increased. 4) The light shelf with the punching plate incurs a 50% energy loss in comparison to the light shelf with no punching plate. However, its effectiveness has been proven in the aspects that it can bring a 50% energy saving in comparison to the case with no installation of light shelf and that it can be designed in response to wind pressure on the high floors.

확산필름 부착 위치에 따른 광선반 성능개선 연구 (Research of the Performance Improvement of a Light Shelf Depending on the Diffusion Film Installation Position)

  • 박은수;이행우;송석재;김용성
    • KIEAE Journal
    • /
    • 제17권3호
    • /
    • pp.91-97
    • /
    • 2017
  • Purpose: Various studies on a light shelf are in progress, but it has the problem of glare occurrence. The present study suggested a diffusion film as the method for resolving the glare problem, and aimed to establish light shelf-related basic data by conducting the performance evaluation of a light shelf depending on the installation position of the diffusion film. Method: To carry out the light shelf performance evaluation depending on the diffusion film installation position, three cases were established: no diffusion film installation (Case 1), diffusion film installation on the reflector (Case 2), and diffusion film installation on the upper glass surface of the window for light shelf installation (Case 3); and the energy reduction performance, luminance, and luminance contrast were analyzed based on a testbed. Result: The conclusions of this study are as follows. 1) When the diffusion film was applied, the amount of light introduced through the light shelf decreased, and the average indoor illumination decreased accordingly. 2) For Case 3, the lighting energy reduction performance was identical to the lighting energy reduction efficiency of the existing light shelf; and for Case 2, it was found to be inappropriate as the lighting energy consumption increased compared to that of the existing light shelf. 3) The analysis of the glare for the cases established in this study showed that the luminance contrast was low for Case 3, and thus the glare problem could be minimized. 4) The specific angle of the light shelf could induce the glare problem by increasing the luminance depending on the external condition. 5) Based on the aforementioned contents, the installation position of the diffusion film for improving the lighting performance and glare problem of the light shelf was found to be the upper glass surface of the window for light shelf installation.

Development of Awning System using Light Shelf - Focusing on the light environment and lighting energy reduction performance improvement -

  • Jeong, Jinsoo;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • 제17권3호
    • /
    • pp.5-13
    • /
    • 2017
  • Purpose: Various studies have been performed to address the issue of increased energy use by buildings. In particular, research on complex envelopes that combines diverse envelope element techniques is currently in progress in the building sector. The present study aimed to develop an awning system using a light shelf, and to verify its validity through performance evaluation. Method: In the present study, a testbed was established for the performance evaluation of the awning system using a light shelf, and the uniformity ratio and lighting energy consumption were compared and analyzed relative to those with no awning and light shelf installation (Case 1), awning installation (Case 2), and light shelf installation (Case 3). Result: 1) In the present study, an awning system using a light shelf (Case 4) where an opening is made on the awning screen and natural light can be introduced through the light shelf located at the bottom was developed. 2) The optimum standard for Case 4 obtained through the performance evaluation was a 0.6m lighting length and a 2m extension length at a light shelf angle of $30^{\circ}$. 3) Case 4 with the optimum standard had a 5.5% lower uniformity ratio than Case 2, but had a higher uniformity ratio than Case 1 and Case 3. 4) Case 4 with the optimum standard showed 13.3%, 44.6%, and 0%~8.7% lighting energy reductions compared to Case 1, Case 2, and Case 3, respectively. 5) Based on the above results, Case 4 suggested in the present study was found to be effective for indoor light environment improvement and lighting energy reduction.

공동주택 녹색건축인증기준의 외부공간 환경성능 평가지표 보완방안 - 기후변화 대응 측면을 중심으로 - (Complementary measures for Environmental Performance Evaluation Index of External Space of Green Standard for Energy and Environmental Design for Apartment Complex - Focused on the Respect of Response to Climate Change -)

  • 예태곤;김광현;권영상
    • 대한건축학회논문집:계획계
    • /
    • 제34권1호
    • /
    • pp.3-14
    • /
    • 2018
  • An apartment complex is a building use with great potential to contribute to solving problems related to urban ecological environment and climate change. The first goal of this study is to grasp the current situation of application and limitations of the ecological area rate, which is a representative evaluation index used to evaluate the environmental performance of the external space of an apartment complex in Green Standard for Energy and Environmental Design (G-SEED). The second goal is to propose a prototype of the evaluation index for evaluating greenhouse gas (GHG) reduction performance in order to supplement the evaluation index for the environmental performance of the external space in terms of response to climate change. We analyzed 43 cases of apartment complexes certified according to G-SEED, which was enforced since July 1, 2010, and found application characteristics of each space type and the limitations of ecological area rate. We analyzed overseas green building certification systems such as LEED and BREEAM that derived implications for supplementing the limitations of ecological area rate, which is focused on the evaluation of soil and water circulation function, and set up a development direction of complementary measures. Through analysis of previous studies, relevant regulations and standards, and technical documents of the manufacturer, the heat island mitigation performance of the pavement and roof surfaces of the apartment complex and the carbon uptake performance of the trees in the apartment complex was selected as parameters to yield the GHG reduction performance of the external space of the apartment complex. Finally, a quantitative evaluation method for each parameter and a prototype of the evaluation index for the GHG reduction performance were proposed. As a result of applying the prototype to an apartment complex case, the possibility of adoption and applicability as an evaluation index of G-SEED were proved.