• 제목/요약/키워드: Echo reduction

검색결과 65건 처리시간 0.031초

용접결함 검사용 수침식초음파탐상기의 매질개선연구 (A Study on Couplant Medium Improvement for Ultrasonic Inspection System with Water Immersion to Detect Weld Defects)

  • 정달우;최낙삼;박용배
    • 한국자동차공학회논문집
    • /
    • 제16권5호
    • /
    • pp.8-14
    • /
    • 2008
  • For nondestructive inspection of electron beam (EB) welding part in automotive power transmission assembly, a pulse-echo ultrasonic testing apparatus in water immersion has been applied using the ultrasonic waves with a frequency of 10MHz. However various problems have appeared during the ultrasonic inspection, which led to some significant mistakes in automatic quality evaluation of the welding parts. Experimental study showed that the state of water couplant medium containing some amount of contaminants, rusts and anti-corrosion agents had considerable influences on the reduction of ultrasonic amplitudes during wave propagation. The amplitude reduction depending on the coupling medium state could bring about some mis-diagnoses for defects in the welding parts. The results proposed that for a reliable inspection of defects in welds the state of water medium should be kept in about 15 volume fractions (vol.%) of anti-corrosion agents and in minimized contaminants.

Hyperion 영상의 분류를 위한 밴드 추출 (Feature Selection for Image Classification of Hyperion Data)

  • 한동엽;조영욱;김용일;이용웅
    • 대한원격탐사학회지
    • /
    • 제19권2호
    • /
    • pp.170-179
    • /
    • 2003
  • 다중분광 영상의 정확한 지형지물 분류를 수행할 때 고려해야 할 중요한 요소중에 적절한 분류 클래스의 선정과 선정된 클래스의 분리도가 높아지도록 트레이닝 지역(training fields)을 잡는 것은 특히 중요하다. 최근에 이용되고 있는 위성탑재 하이퍼스펙트럴(hyperspectral) 영상은 많은 밴드를 포함하고 있기 때문에 데이터 처리가 어렵고, 잡음(noise)으로 인하여 다중분광 영상보다 분류 결과가 나쁜 경우도 나타난다. 특히 대상지역의 클래스에 따른 트레이닝 지역의 선정시 일부 클래스에서 하이퍼스펙트럴 밴드수에 비해 상대적으로 적은 수의 트레이닝 샘플로 인하여 공분산 행렬의 계산에 어려움이 따른다. 따라서 본 연구에서는 Hyperion 데이터를 이용한 분류를 수행하기 위하여 밴드 추출 방식을 알아보고, 분류영상의 정확도 평가를 통하여 밴드 추출의 효용성을 시험하였다. 밴드를 줄이는 또 다른 방법인 클래스간 분리도에 따른 최적 밴드를 추출하여 분류정확도를 평가하였다. 실험 결과, 밴드 추출이나 클래스 분리도에 따라 선택된 영상의 분류 정확도는 분류자(classifier)에 상관없이 전체 밴드를 사용한 원영상과 유사하게 나타났지만, 사용된 밴드수와 계산 시간은 단축되었다. 분류자는 MLC, SAM, ECHO의 3종류가 사용되었다.

주파수 변조 DANTE를 이용한 자화율 효과의 감소 (Reduction of Susceptibility Effect Using Frequency Modulation DANTE)

  • 정성택;홍인기;김지훈;노용만;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.167-170
    • /
    • 1995
  • An frequency modulated (FM) DANTE pulse sequence generates a quadratic phase toward the transverse of image by an FM RF pulse. In the image of a serious susceptibility effect, the phase due to the difference of the susceptibility in the pixel occurs susceptibility error which arise signal loss. But the signal loss due to the susceptibility effect in the pixel is reduced when the quadratic phase adds in the pixel. In this paper, we have generated a quadratic function toward the transverse (X-Y) using FM DANTE sequence and the susceptibility effect is reduced in the gradient echo (GE) imaging. Computer simulation and experimental results is obtained by using a whole-body KAIS 2.0T NMR system.

  • PDF

시간 영역 에너지 Companding을 사용한 프리 에코 감소 방법 (Pre-Echo Reduction Using Time Domain Energy Companding)

  • 김재원;임유진;유정찬;서은미;박호종
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송∙미디어공학회 2022년도 하계학술대회
    • /
    • pp.61-62
    • /
    • 2022
  • 본 논문에서는 시간 영역 에너지의 companding을 이용하여 오디오 부호화에서 발생하는 프리 에코를 효과적으로 감소시키는 방법을 제안한다. 일반적으로 오디오 부호화는 블록 단위의 변환 부호화를 사용하므로 과도 구간에서 프리 에코를 발생시킨다. 프리 에코를 줄이기 위한 기존 TNS 방법은 주파수 영역에서 선형 예측 방법을 사용하며, 부가 정보 전송이 필요하고 성능이 낮은 문제점을 가진다. 제안하는 방법은 시간 영역 에너지의 동적 범위를 감소시킨 후 부호화 하고, 복호화 이후에 에너지를 복원하는 과정을 통하여 양자화 오차의 시간 영역 에너지 분포를 조정하여 프리 에코를 감소시킨다. 제안하는 방법이 TNS보다 우수한 프리 에코 감소 성능을 가지는 것을 확인하였다.

  • PDF

A convergence analysis of Block MADF algorithm for adaptive noise reduction

  • Min, Seung-gi;Young Huh;Yoon, Dal-hwan
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -1
    • /
    • pp.377-380
    • /
    • 2002
  • When it calculates the optimum price of filter coefficient, the many operation quantity is necessary. Is like that the real-time control is difficult and the hardware embodiment expense is big. The case which does not know advance information of input signal or the case where the statistical nature changes with change of surroundings environment is necessary the adaptive filter. Every hour to change a coefficient automatically and system in order to reach to the condition of optimum oneself, the fact that is the adaptive filter. When it does not the quality of input signal or it does not know the environment of surroundings every hour changing, it does not emit not to be, in order to collect, the fact that is the adaptive filter. The case of the Acoustic Echo Canceler does thousands filter coefficients in necessity. It reduces a many calculation quantity to respect, it uses the IIR filter from hour territory. Also it uses the block adaptive filter which has a block input signal and a block output signal. The former there is a weak point where the stability discrimination is always demanded. Consequently, The block adaptive filter is researched plentifully. This dissertation planned the block MADF adaptive filter used to MADf algorithm.

  • PDF

Image Denoising for Metal MRI Exploiting Sparsity and Low Rank Priors

  • Choi, Sangcheon;Park, Jun-Sik;Kim, Hahnsung;Park, Jaeseok
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권4호
    • /
    • pp.215-223
    • /
    • 2016
  • Purpose: The management of metal-induced field inhomogeneities is one of the major concerns of distortion-free magnetic resonance images near metallic implants. The recently proposed method called "Slice Encoding for Metal Artifact Correction (SEMAC)" is an effective spin echo pulse sequence of magnetic resonance imaging (MRI) near metallic implants. However, as SEMAC uses the noisy resolved data elements, SEMAC images can have a major problem for improving the signal-to-noise ratio (SNR) without compromising the correction of metal artifacts. To address that issue, this paper presents a novel reconstruction technique for providing an improvement of the SNR in SEMAC images without sacrificing the correction of metal artifacts. Materials and Methods: Low-rank approximation in each coil image is first performed to suppress the noise in the slice direction, because the signal is highly correlated between SEMAC-encoded slices. Secondly, SEMAC images are reconstructed by the best linear unbiased estimator (BLUE), also known as Gauss-Markov or weighted least squares. Noise levels and correlation in the receiver channels are considered for the sake of SNR optimization. To this end, since distorted excitation profiles are sparse, $l_1$ minimization performs well in recovering the sparse distorted excitation profiles and the sparse modeling of our approach offers excellent correction of metal-induced distortions. Results: Three images reconstructed using SEMAC, SEMAC with the conventional two-step noise reduction, and the proposed image denoising for metal MRI exploiting sparsity and low rank approximation algorithm were compared. The proposed algorithm outperformed two methods and produced 119% SNR better than SEMAC and 89% SNR better than SEMAC with the conventional two-step noise reduction. Conclusion: We successfully demonstrated that the proposed, novel algorithm for SEMAC, if compared with conventional de-noising methods, substantially improves SNR and reduces artifacts.

Improvement of Fat Suppression and Artifact Reduction Using IDEAL Technique in Head and Neck MRI at 3T

  • Hong, Jin Ho;Lee, Ha Young;Kang, Young Hye;Lim, Myung Kwan;Kim, Yeo Ju;Cho, Soon Gu;Kim, Mi Young
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권1호
    • /
    • pp.44-52
    • /
    • 2016
  • Purpose: To quantitatively and qualitatively compare fat-suppressed MRI quality using iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) with that using frequency selective fat-suppression (FSFS) T2- and postcontrast T1-weighted fast spin-echo images of the head and neck at 3T. Materials and Methods: The study was approved by our Institutional Review Board. Prospective MR image analysis was performed in 36 individuals at a single-center. Axial fat suppressed T2- and postcontrast T1-weighted images with IDEAL and FSFS were compared. Visual assessment was performed by two independent readers with respect to; 1) metallic artifacts around oral cavity, 2) susceptibility artifacts around upper airway, paranasal sinus, and head-neck junction, 3) homogeneity of fat suppression, 4) image sharpness, 5) tissue contrast of pathologies and lymph nodes. The signal-to-noise ratios (SNR) for each image sequence were assessed. Results: Both IDEAL fat suppressed T2- and T1-weighted images significantly reduced artifacts around airway, paranasal sinus, and head-neck junction, and significantly improved homogeneous fat suppression in compared to those using FSFS (P < 0.05 for all). IDEAL significantly decreased artifacts around oral cavity on T2-weighted images (P < 0.05, respectively) and improved sharpness, lesion-to-tissue, and lymph node-to-tissue contrast on T1-weighted images (P < 0.05 for all). The mean SNRs were significantly improved on both T1- and T2-weighted IDEAL images (P < 0.05 for all). Conclusion: IDEAL technique improves image quality in the head and neck by reducing artifacts with homogeneous fat suppression, while maintaining a high SNR.

뇌 자기공명영상에서 Quiet-T2 기법을 이용한 소음감소의 유용성 (Usefulness of Acoustic Noise Reduction in Brain MRI Using Quiet-T2)

  • 이세지;김영근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.51-57
    • /
    • 2016
  • 뇌 자기공명영상(Magnetic Resornance Imaging; MRI)에서 검사 중 발생되는 소음을 줄이기 위한 기법으로 경사 파형을 변경한 Quiet $T_2$-weighted Turbo Spin-Echo(이하 Q-$T_2$)와 일반적으로 사용되는 $T_2$-weighted Turbo Spin-Echo(이하 $T_2$) 영상의 소음수준 및 영상의 질을 비교하여 그 유용성을 알아보고자 하였다. 3.0T MR 기기로 뇌 MR 검사를 받은 60명(남자 29명, 여자 31명, 평균 연령 60.1세)의 환자를 대상으로 하였다. Q-$T_2$$T_2$ 각각의 영상에서 소음 및 심박동수를 측정하였다. 정량적 분석은 Q-$T_2$$T_2$의 SNR, CNR, SIR 값을 측정한 뒤 독립표본 T검정을 이용하여 통계적 분석을 하였다. 정성적 분석은 Q-$T_2$$T_2$의 전체적인 영상의 질에 대하여 육안으로 평가하였다. 평가는 5점 척도로서 우수(excellent) 5점, 양호(good) 4점, 보통(fair) 3점, 불량(poor) 2점, 평가불가(unacceptable) 1점으로 평가하였다. Q-$T_2$$T_2$ 검사 중 평균소음과 peak소음은 Q-$T_2$가 기존 $T_2$에 비해 각각 $15dB_A$, $10dB_A$ 감소하였다. 또한 각각의 검사 중 120초 동안 심박동수의 평균값은 Q-$T_2$에서 더 낮은 값으로 나타났지만 통계적인 유의성은 없었다. 정량적 분석의 결과 CNR과 SIR은 유의한 차이가 없었으며, SNR은 Q-$T_2$가 더 낮은 평균값을 보임으로서 유의한 차이를 보였다(p<0.05). 정성적 분석은 59개의 Q-$T_2$$T_2$ 영상의 질이 동일하게 우수(excellent) 5점으로 평가되었으며, 1개의 영상에서 모션 아티팩트로 인해 양호(good) 4점으로 평가되었다. Q-$T_2$는 기존의 $T_2$와 같이 검사시간 및 진단의 정확도는 동일하지만 소음을 효과적으로 감소시킬 수 있으며, 이로인하여 환자 편의를 향상시킬 수 있을 것으로 사료된다.

Metabolic Changes in Patients with Parkinson's Disease after Stereotactic Neurosurgery by Follow-up 1H MR Spectroscopy

  • Choe, Bo-Young;Baik, Hyun-Man;Chun, Shin-Soo;Son, Byung-Chul;Kim, Moon-Chan;Kim, Bum-Soo;Lee, Hyoung-Koo;Suh, Tae-Suk
    • 한국자기공명학회논문지
    • /
    • 제5권2호
    • /
    • pp.99-109
    • /
    • 2001
  • Authors investigated neuronal changes of local cellular metabolism in the cerebral lesions of Parkinsonian symptomatic side between before and after stereotactic neurosurgery by follow-up 1H magnetic resonance spectroscopy (MRS). Patients with Parkinson's disease (PD) (n = 15) and age-matched normal controls (n = 15) underwen MRS examinations using a stimulated echo acquisition mode (STEAM) pulse sequence that provided 2${\times}$2${\times}$2 ㎤ (8ml) volume of interest in the regions of substantia nigra, thalamus, and lentiform nucleus. Spectral parameters were 20 ms TE, 2000 ms TR, 128 averages,2500 Hz spectral width, and 2048 data points. Raw data were processed by the SAGE data analysis package (GE Medical Systems). Peak areas of N-acetylaspartate (NAA), creatine (Cr), choline-containing compounds (Cho), inositols (Ins), and the sum (Glx) of glutamate and GABA were calculated by means of fitting the spectrum to a summation of Lorentzian curves using Marquardt algorithm. After blindly processed, we evaluated neuronal alterations of observable metabolite ratios between before and after stereotactic neurosurgery using Pearson product-moment analysis (SPSS, Ver. 6.0). A significant reduction of NAA/Cho ratio was observed in the cerebral lesion in substantia nigra of PD patient related to the symptomatic side after neurosurgery (P : 0.03). In thalamus, NAA/Cho ratio was also significantly decreased in the cerebral lesion including the electrode-surgical region (P : 0.03). A significant reduction of NAA/Cho ratio in lentiform nucleus was not oberved, but tended toward significant reduction after neurosurgery (P = 0.08). In particular, remarkable lactate signal was noted from the surgical thalamic lesions of 6 among 8 patients and internal segments of globus pallidus of 6 among 7 patients, respectively. Significant metabolic alterations of NAA/Cho ratio might reflect functional changes of neuropathological processes in the lesion of substantia nigra, thalamus, and lentiform nucleus, and could be a valuable finding fur evaluation of Parkinson's disease after neurosurgery. Increase of lactate signals, being remarkable in surgical lesions, could be consistent with a common consequence of neurosurgical necrosis. Thus, IH MRS could be a useful modality to evaluate the diagnostic and prognostic implications fur Parkinsons disease after functional neurosurgery.

  • PDF

기상청 동네예보의 영농활용도 증진을 위한 방안: 2. 강수량 분포 상세화 (Improving Usage of the Korea Meteorological Administration's Digital Forecasts in Agriculture: 2. Refining the Distribution of Precipitation Amount)

  • 김대준;윤진일
    • 한국농림기상학회지
    • /
    • 제15권3호
    • /
    • pp.171-177
    • /
    • 2013
  • 본 연구는 기상청에서 제공하는 강수 실황 혹은 예보로부터 농업부문에서 활용 가능한 수준의 상세한 강수분포도를 제작하기 위한 방안으로서, 레이더 반사강도를 KLAPS 5km 강수자료에 적용하여 1km 격자해상도로 상세화 하는 1단계와, 고해상도 DEM에 근거한 지표면 경사방향(지향면)에 따라 고도-강수량 회귀 계수를 달리하여 지형효과를 반영하는 2단계 등으로 이루어진 추정기법을 고안하였다. 이 기법의 현실세계 적용방법 모색 및 신뢰도 평가를 위해 경상남도 하동군 악양면을 실험 집수역으로 설정하고 2013년 1월부터 5월까지 총 19사례의 강수에 대해 기상청으로부터 KLAPS 강수자료를 수집하였다. 1단계로는 강수일의 24시간 적산 레이더에코 자료를 이용하여 1km 해상도로 자료의 규모를 축소하였다. 2단계로는 1km 격자점의 값을 가상의 관측자료로 삼아 270m 해상도에서 PRISM 기반의 지형효과를 반영한 강수량 분포도를 생성하였다. 실험 집수역에 13대의 무인기상관측장비를 다양한 고도 및 지형조건에서 설치하고, 추정된 강수분포도로부터 13개 지점에 해당하는 격자점의 자료를 추출하여 실측값과 비교하였다. 일 강수량 10mm 이상의 사례에서는 모든 관측지점에서 추정오차 감소효과가 인정되었으며, 특히 일강수량이 30mm 이상인 사례에서 평균 35% 이상의 오차감소효과를 확인하였다.