• Title/Summary/Keyword: Echo reduction

Search Result 65, Processing Time 0.02 seconds

A Durability Study on the Acoustic Baffle for Underwater Environment (수중 환경용 음향 배플의 내구성 연구)

  • Seo, Young Soo;Kim, Dong Hyun;Kim, Jin Tae;Kang, Myeng Hwan;Jung, Woo Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.449-457
    • /
    • 2016
  • Cylindrical array sensor of a surface ship to detect an enemy is normally installed in the sonar dome. Reflected signals by some structures inside the sonar dome make unwanted signals. To minimize unwanted signals, acoustic baffles are used. Acoustic baffles are hard to install and replace, so the durability of acoustic baffles is an important design parameter. To verify the durability of acoustic baffle, accelerated aging tests according to temperature and pressure were performed. Acoustic baffle specimens were made and they are tested the visual and the performance (echo reduction and transmission loss) inspection before and after aging. After the inspection, the effect of accelerated aging of the acoustic baffles were discussed.

Development of Underwater Acoustic Performance Measurement System Using Pulse Tubes (펄스 튜브를 이용한 수중 음향 성능 측정 시스템 개발)

  • Seo, Yun-Ho;Kim, SangRyul;Lee, Sung-Min;Byun, Yang-Heon;Seo, Youngsoo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.5
    • /
    • pp.399-406
    • /
    • 2014
  • Underwater acoustic materials are installed in order to reduce reflection, transmission and radiation of an underwater structure. The acoustic performance of the materials should be evaluated in accurately-controlled environment in terms of temperature and static pressure. In this paper, two pulse tubes, which are equipped with temperature and pressure controllers, are designed and developed to evaluate echo reduction(ER) and transmission loss(TL) of underwater acoustic materials. The procedures of the evaluation are suggested and the validation is carried out by comparing theoretical values to experimental results for a simple stainless steel specimen and free surface. In result, it is validated that developed pulse tubes are able to measure ER and TL with 2 dB tolerance.

A New Analysis and a Reduction Method of Computational Complexity for the Lattice Transversal Joint (LTJ) Adaptive Filter (격자 트랜스버설 결합 (LTJ) 적응필터의 새로운 해석과 계산량 감소 방법)

  • 유재하
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.5
    • /
    • pp.438-445
    • /
    • 2002
  • In this paper, the necessity of the filter coefficients compensation for the lattice transversal joint (LTJ) adaptive filter was explained in general and with ease by analyzing it with respect to the time-varying transform domain adaptive filter. And also the reduction method of computational complexity for filter coefficients compensation was proposed using the property that speech signal is stationary during a short time period and its effectiveness was verified through experiments using artificial and real speech signals. The proposed adaptive filter reduces the computational complexity for filter coefficients compensation by 95%, and when the filter is applied to the acoustic echo canceller with 1000 taps, the total complexity is reduced by 82%.

The Study on Reduction of Image Distortion by using Single-Shot Turbo Spin Echo in Brain Stem Diffusion MRI (자기공명 확산강조영상검사 시 영상왜곡 감소에 관한 연구)

  • Choi, Kwan-Woo;Lee, Ho-Beom;Na, Sa-Ra;Yoo, Beong-Gyu;Son, Soon-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.279-284
    • /
    • 2016
  • Single-shot echo planar imaging(SS-EPI) is well established as high sensitivity for ischemic stroke. However, it is prone to susceptibility artifact in brain stem that diminish the image quality. single-shot turbo spin echo(SS-TSE) is a new DWI technique that can reduce susceptibility artifact. Thus, this research was conducted so as to reduce geometric distortion in brain stem by using single-shot turbo spin echo technique. Thirty patients without brain disease underwent diffusion MR on a 3T scanner with SS-EPI and SS-TSE. Obtained images with both sequences were analyzed for geometric distortion and error percentage as well. Image quality in terms of geometric distortion of SS-TSE were found to be significantly better than those for SS-EPI. And error percentage was considerably reduced for 2.4% of b0 image(from 11.1% to 8.7%), 1.2% of b1000 image(from 11.4% to 10.1%), respectively. In summary, diffusion MR using SS-TSE significantly reduce geometric distortion compared to SS-EPI in brain stem and may provide improved diagnostic performance.

A New TE/TR Reduction Technique in MR Pulse Sequences and Its Application to Radial Imaging

  • 김용권;류연철;오창현
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.18-18
    • /
    • 2003
  • 목적: MRI 시스템에서 얻어지는 Data는 TR(Repetition Time)과 TE(Echo Time)에 따라서 신호 대잡음비(SNR), 조직들간의 대조도(Contrast), Artifact 및 촬영시간이 결정된다. 이 연구에서는 TR/TE를 줄이는 기법을 이용한 Radial Imaging 영상기법을 제시하고자 한다. 대상 및 방법: 일반적인 Radial Imaging 기법에 HASTE 기법과 Non-uniform sampling 기법의 특징을 이용하여 구현하였으며, TR/TE를 줄일 수 있었으며 얻어진 K-space Data는 가변주파수 역 Fourier Transform을 이용하여 Projection Data를 재구성한 후 Back Projection 기법을 이용하여 최종 영상을 재구성한다.

  • PDF

An Acoustic Reception Ability Analysis of SONAR Multilayer Structures by Using Elastic Theory (탄성이론을 이용한 소나 다층구조물의 음향 수신 성능해석)

  • Kwon, Hyun-Wung;Hong, Suk-Yoon;Song, Jee-Hun;Kim, Sung-Hee;Jeon, Jae-Jin;Seo, Young-Soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.301-307
    • /
    • 2013
  • SONAR detection performance is one of the key survivability factors in underwater weapon systems. In order to catch the acoustic ability of SONAR, multilayer SONAR structures are analyzed using the elastic theory. The applied results for the simple models are compared with those from commercial program, ANSYS, and the reliable results are obtained. The analysis of sound pressure level (SPL) and echo reduction (ER) by the thickness change of multilayer SONAR structures are performed using the verified elastic theory. As the thickness of anechoic layer is increased, SPL is distributed evenly and ER is increased slightly with the frequency. In decoupling layers and steel layers, SPL are hardly changed and ER is slightly decreased with the thickness increase of those layers. SPL and ER are not affected by the thickness change of the carbon reinforced plastic (CRP) layer. Therefore, to improve the acoustic ability of multilayer SONAR structures, the thickness increase of the anechoic layer and minimization of the decoupling layer, steel layer and CRP layer are desirable.

Acoustic radiation characteristics of a tile projector with performance variations among unit transducers (단위 트랜스듀서 간 성능편차를 갖는 타일형 프로젝터의 음향방사 특성)

  • Chun, Wonjong;Noh, Eunghwy;Ohm, Won-Suk;Seo, Youngsoo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.436-444
    • /
    • 2016
  • Uniformity in transducer performance is a must-have to ensure the reliable acoustic performance of a tile projector, used for active echo reduction. However, practical limitations imposed by variations in material properties and fabrication errors lead to performance variations among unit transducers, which could degrade the radiation characteristics (transmitting voltage response and directivity) of the tile projector and ultimately the echo reduction performance. In this paper we present a method to minimize these adverse effects via an appropriate placement of unit transducers within the tile projector. To this end, we perform a series of coupled acoustic-piezoelectric simulations, assuming a group of 36 unit transducers having 6 dB variations in transmitting voltage response, to analyze and compare the radiation characteristics of tile projectors under different transducer placement schemes.

Measurement System for Performance Evaluation of Acoustic Materials in a Small Water Tank (소형수조에서 음향재료의 반향음감소와 투과손실 측정시스템 구성)

  • Shin, Mi-Ru;Cho, Jung-Hong;Lee, Kyung-Teak;Kim, Jea-Soo;Jeon, Jae-Jin;Ham, Il-Bea;Kang, Chang-Gi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.2
    • /
    • pp.63-72
    • /
    • 2011
  • Since the detection probability is critically dependent on the target strength (TS) in active sonar and on the radiated noise level (RNL) in passive sonar, the acoustic materials for echo reduction (ER) and transmission loss (TL) are widely used for the stealth of underwater targets. In this paper, a measurement system based on the small water tank, for the frequency range of greater than 30 kHz, is developed and verified using reference targets. In order to design the water tank and the geometry of test samples, a program is developed to calculate the arrival time of interfering signals due to the reflection from water tank walls and also due to the diffraction from the edge of the test samples. Considering all the interfering signals, an optimal experimental configuration for water tank and test samples is designed and used throughout the experiment. Next, the signal processing algorithms to estimate ER and TL are developed based on the measured propagation loss reflecting the geometric spreading characteristics of the transducer. Finally, a set of reference targets such as aluminium plate and perfectly reflecting plate are used in a small water tank to verify the developed measurement system.

Usefulness of Median Modified Wiener Filter Algorithm for Noise Reduction in Liver Cirrhosis Ultrasound Image (간경변 초음파 영상에서의 노이즈 제거를 위한 Median Modified Wiener Filter 알고리즘의 유용성)

  • Seung-Yeon Kim;Soo-Min Kang;Youngjin Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.911-917
    • /
    • 2023
  • The method of observing nodular changes on the liver surface using clinical ultrasonography is useful for diagnosing cirrhosis. However, the speckle noise that inevitably occurs in ultrasound images makes it difficult to identify changes in the liver surface and echo patterns, which has a negative impact on the diagnosis of cirrhosis. The purpose of this study is to model the median modified Wiener filter (MMWF), which can efficiently reduce noise in cirrhotic ultrasound images, and confirm its applicability. Ultrasound images were acquired using an ACR phantom and an actual cirrhotic patient, and the proposed MMWF algorithm and conventional noise reduction algorithm were applied to each image. Coefficient of variation (COV) and edge rise distance (ERD) were used as quantitative image quality evaluation factors for the acquired ultrasound images. We confirmed that the MMWF algorithm improved both COV and ERD values compared to the conventional noise reduction algorithm in both ACR phantom and real ultrasound images of cirrhotic patients. In conclusion, the proposed MMWF algorithm is expected to contribute to improving the diagnosis rate of cirrhosis patients by reducing the noise level and improving spatial resolution at the same time.

A STUDY ON THE CHANGES OF MR SIGNAL INTENSITY OF POSTERIOR ATTACHMENT OF THE TEMPOROMANDIBULAR JOINT (악관절 후방부착부에 있어서 MRI 신호변화에 대한 고찰)

  • Jung, Joo-Sung;Huh, Won-Shil;Chung, Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.19 no.1
    • /
    • pp.93-107
    • /
    • 1997
  • Magnetic resonance imaging has been used in the temporomandibular joint(TMJ) primarily to define morphology and positional relationship of associating structures. This report examines signal intensity characteristics of the posterior attachment as they related to the severity of internal derangement. Fifty six joints in 35 patients with a history of TMJ dysfunction were imaged writ MR using $T_1$-weighted spin echo sequence. According to disk position, ability to reduction, and the presence of osteoarthritis, the joints were categorized into three groups. A group 1 was anterior disk displacement with reduction; a group 2 was anterior disk displacement without reduction; a group 3 was anterior disk displacement without reduction and condyle had osteoarthritic change. The control group was determined by the clinical absence of any signs or symptoms of current or past TMJ pain and dysfunction. Calculated the relative value of MR signal intensity in posterior attachment and disk to cerebral cortex of temporal lobe by means of computer program, we have compared them with each groups. The result showed statistically little significant difference of disk signal intensity among each groups. but, signal intensity from posterior attachment in group 2 and 3 were significantly(p<0.05) decreased than control group. this might reflect an fibrosis or hyalinization of posterior attachment, which was part of remodeling process that occurs in disk displacement without reduction. However, this study could not demonstrate histologic confirmation of the decreased signal intensity in the posterior attachment. So, further investigation could be needed to understand the association between them.

  • PDF