• Title/Summary/Keyword: Eccentric¬

Search Result 176, Processing Time 0.024 seconds

The effects of cryotherapy on delayed onset muscle soreness (지연발생 근육통의 냉치료 효과에 대한 연구)

  • Kim, Sang-Yeob
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.2
    • /
    • pp.1065-1071
    • /
    • 2001
  • Delayed onset muscle soreness is a sensation of discomfort that occurs 24 h after exercise, and it is associated with the performance of unfamiliar and high force muscle work, such as eccentric contractions. The injury to the muscle has been well described but the mechanism underlying the injury is not fully understood. Although the pathophysiological processes underlying delayed onset muscle soreness are not completely understood, many researchers have investigated various treatments in a attempt to reduce the soreness. Physical therapy is the most importance techniques to reduce delayed onset muscle soreness. The purpose of this study is to investigate the effect of a cryotherapt on DOMS. Thirty subjects were randomly assigned to experimental group : control, cryotherapy, and placebo group. Elbow flexion range, mechanical pain threshold. and subjective pain were measured 30 min before DOMS was induced and 24, 48, 72 hours after DOMS was induced. The results of this study were as follows: 1. Elbow flexion range showed significant difference each time, especially at 48 and 72 hours 2. Mechanical pain thershold and subjectively pain showed no significant difference between group.

  • PDF

Changes in Inflammatory Mediators, Immunocompetent Cells and Bone Merrow Progenitor Cells by the Magnitude of Muscle Damage and Type of the Muscle Contraction in the Elderly (고령자의 근육수축양식 및 손상정도에 따른 염증물질, 면역적격세포 및 골수유래 전구세포의 변화)

  • Song, Sang-Hyup;Lee, Ho-Seong
    • 한국체육학회지인문사회과학편
    • /
    • v.54 no.5
    • /
    • pp.769-780
    • /
    • 2015
  • This study investigated the changes in inflammatory mediators, immunocompetent cells and bone merrow progenitor cells by the magnitude of muscle damage and type of the muscle contraction in the elderly. Twenty older adults who had not been involved in a resistance-training program at least 6 months prior to the present study were assigned to eccentric exercise group (ECC, n=10) and concentric exercise group (CON, n=10). All subjects performed 10 sets of 6 maximal isokinetic eccentric (ECC 1) or concentric (CON) contractions with the non-dominant arm in a randomized, with 4 wk between bouts (ECC 2). Skeletal muscle damage index (ROM, VAS, Plasma CK), inflammation mediators (TNF-α, IL-1, IL-6), immunocomperent cells (CD3+, CD4+, CD8+, CD19+), bone merrow progenitor cell (CD34+) and leukocytes were measured before, immediately after, 2, 24, 48, 72, and 96 h after exercise. Changes in ROM and VAS were greater (P<.05) after ECC 1 than CON and ECC 2. Increases in TNF-α and IL-6 were greater (P<.05) 24, 48 and 72 h after ECC 1 than CON and ECC 2. Increases in neutrophils were greater (P<.05) 2 h after ECC 1 than CON and ECC 2. It was confirmed that muscle damage was greater following eccentric than concentric contractions as well as first bout than second bout in the elderly, and suggested that TNF-α, IL-6 and neutrophils should closely correlate with magnitude of muscle damage.

An Experimental Study on the Ultimate Strength and Deformation Capacity of Composite Beams with Eccentric Web Openings (편심유공합성보의 종국내력 및 변형능력에 관한 실험적 연구)

  • Choi, San Ho;Seo, Seong Yeon
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.5 s.48
    • /
    • pp.595-604
    • /
    • 2000
  • Web openings of large beams provide space for wiring, piping, and duct work to provide for proper drainage, pipes and duct must be slightly sloped with the attendant result that all web openings can not be centered on the centroidal axes of the beams. Test specimens are made for opening-depth to beam-depth ratio of 0.5 and for eccentricities of the opening center line of 10% from middepth of the beam because of the proximity of the opening edge to the flange. In this paper, available test results and theories relating to the strength of composite beams having eccentric rectangular openings are surveyed and experiments were carried out to examine the structural behaviors. In all the tests in this paper good agreement is demonstrated with maximum loads measured in tests, and observed failure modes Furthermore, compared with analytical values and experimental values of interaction diagram between moment and shear capacity were safed as it is scattered with outer part of the analytical values.

  • PDF

A Study of TMJ dysfunction using PRI (PRI를 이용한 측두하악장애에 관한 연구)

  • Kwang Ho Lee;Sung Woo Lee
    • Journal of Oral Medicine and Pain
    • /
    • v.11 no.1
    • /
    • pp.57-66
    • /
    • 1986
  • A study of occlusal relationship and TMJ dysfunction, parafunctional relationship and TMJ dysfunction using PRI was investigated in 23 dental students without history of being treated, ranging from 19 to 24 years old. The author used Denar Pantronic and D5-A articulator to study above. The obtained results were as follows : 1. Distribution of PRI in experimental subjects was as follows. None 13%, Slight 43%, Moderate 40%, Severe 4% Prevalance of TMJ Dysfunction was 87% 2. PRI scores of occlusal group Aoi (less than 5 in Helkimo occlusion/articulation index) was $11.72\pm2.32$ , those of occlusal group Boi (more than 5 in Helkimo occlusion/articulation index) 23.0 $\pm$ 8.06. There was a significant difference between group Aoi and group Boi(P<0.01) 3. PRI scores of occlusal group Ald (no eccentric interference, less than 0.5mm in lateral shift of slide in centric) was 12.0 $\pm$ 2.49, those of occlusal group Bld(no eccentric interference, less than 0.5mm in lateral shift of slide in centric) 24.5$\pm$5.33 There was a significant difference between group Ald and group Bld(P<0.05) 4. Prevalance of parafunction subjects(%) was 65.2%. 5. PRI scores of parafunction group was 21.6 $\pm$ 9.48, those of nonparafunctional group 18.7 $\pm$ 9.06. There was not significant difference between parafunctional group and nonparafunctional group(P>0.1)

  • PDF

OCCLUSAL ANALYSIS OF PATIENTS WITH TEMPOROMANDIBULAR DYSFUNCTION BY USE OF T-SCAN SYSTEM (T-Scan system을 이용한 측두하악 장애 환자의 교합 분석에 관한 연구)

  • Park Seon-Joo;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.3
    • /
    • pp.121-140
    • /
    • 1991
  • Fifteen dental college students of Chosun University without the abnormal occlusion, the history and symptom of temporomandibular dysfunction(TMD), and who had all permanent teeth except third molar and the fifteen moderate group and the fifteen severe group classified according to Helkimo's dysfunction index among patients on the basis of the symptom of TMD were selected. The occlusal contact, occlusal force and occlusal interference in eccentric movement was studied and analyzed using T-Scan system. The result were as follows : 1. The TLR centering around midsagittal axis was located at $1.42{\pm}0.82mm$ in control group, $3.36{\pm}1.45mm$ in severe group, and as TMD was heavier, occlusal contact was located at the farther point from midsagittal axis. 2. The PLR from the first contact to the fifth contact centering around midsagittal axis was located at $1.73{\pm}1.78mm$ in control group, $3.36{\pm}1.41mm$ in moderate group, and $5.39{\pm}4.32mm$ in severe group, and as TMD was heavier, occlusal contact was located at the farther point from midsgittal axis. 3. The TFB, PFB, RFB and LFB of occlusal contact centering around incisal axis had no significant difference statistically among control group, moderate group, and severe group, and it was located at first molar. 4.The LF and RF was smaller in TMD group than in control group. 5. The LR moment of occlusal force centering around midsagittal axis was located at $178.51{\pm}139.81N.mm$ in control group, $466.25{\pm}296.47N.mm$ in moderate group, and $749.18{\pm}588.18N.mm$ in severe group. And as TMD was heavier, it was located at the farther point from midsagittal axis. 6. The RL and LL of occlusal force centering around incisal axis had not-significance statistically among control group, moderate group, and severe group, and it was at the first molar. 7. The number of occlusal interference of the eccentric movement was increased in the patients of TMD.

  • PDF

Analytical Study on the Structural Behaviors of Stub Columns Fabricated with HSA800 of High Performance Steel Subjected to Eccentric Loads (편심하중을 받는 고성능강(HSA800) 조립 단주의 구조거동에 관한 해석적 연구)

  • Yoo, Jung Han;Kim, Joo Woo;Yang, Jae Guen;Kang, Joo Won;Lee, Dong Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.453-461
    • /
    • 2014
  • In this study, the stub columns of built-up H-section and square hollow section subjected to eccentrical loads are tested to evaluate the applicability of the structural members with 800MPa high-strength steel (HSA800) on current design specification. Analytical studies of FE model are conducted to validate the test results and then the verified FE models are used for extensive parametric studies for checking up the applicability of current design code. The parameters are width-to-thickness ratios and axial load ratios. From P-M correlations on parameter models, all stub columns with non-compact sections exceed the current design requirements about axial force and flexural strength ratios are sufficiently secured as the axial load ratios are decreased. The built-up hollow sections with slender section model do not satisfy the current design specification about axial force.

Strength of Interior Plat Plate-Column Connections Subjected to Unbalanced Moment (불균등 휨모멘트를 받는 플랫 플레이트-기둥 접합부의 강도산정모델)

  • 최경규;박홍근
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.961-972
    • /
    • 2002
  • Flat plate structures under lateral load are susceptible to the brittle shear failure of plate-column connection. To prevent such brittle failure, strength and ductility of the connection should be ensured. However, according to previous studies, current design methods do not accurately estimate the strength of plate-column connection. In the present study, parametric study using nonlinear finite element analysis was performed for interior connections. Based on the numerical results, a design method for the connection was developed. At the critical sections around the connection coexist flexural moment and shear developed by lateral and gravity loads, and maximum allowable eccentric shear stresses were proposed based on the interactions between the flexural moment and shear, The proposed method can precisely predict the strength of the connection, compared with the current design provisions. The predictability of the proposed method was verified by the comparisons with existing experiments and nonlinear numerical analyses.

Partial Confinement Utilization for Rectangular Concrete Columns Subjected to Biaxial Bending and Axial Compression

  • Abd El Fattah, Ahmed M.;Rasheed, Hayder A.;Al-Rahmani, Ahmed H.
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.1
    • /
    • pp.135-149
    • /
    • 2017
  • The prediction of the actual ultimate capacity of confined concrete columns requires partial confinement utilization under eccentric loading. This is attributed to the reduction in compression zone compared to columns under pure axial compression. Modern codes and standards are introducing the need to perform extreme event analysis under static loads. There has been a number of studies that focused on the analysis and testing of concentric columns. On the other hand, the augmentation of compressive strength due to partial confinement has not been treated before. The higher eccentricity causes smaller confined concrete region in compression yielding smaller increase in strength of concrete. Accordingly, the ultimate eccentric confined strength is gradually reduced from the fully confined value $f_{cc}$ (at zero eccentricity) to the unconfined value $f^{\prime}_c$ (at infinite eccentricity) as a function of the ratio of compression area to total area of each eccentricity. This approach is used to implement an adaptive Mander model for analyzing eccentrically loaded columns. Generalization of the 3D moment of area approach is implemented based on proportional loading, fiber model and the secant stiffness approach, in an incremental-iterative numerical procedure to achieve the equilibrium path of $P-{\varepsilon}$ and $M-{\varphi}$ response up to failure. This numerical analysis is adapted to assess the confining effect in rectangular columns confined with conventional lateral steel. This analysis is validated against experimental data found in the literature showing good correlation to the partial confinement model while rendering the full confinement treatment unsafe.

Development of Welding Quality Monitoring Method for TIG Cladding (TIG클래딩 공정에 대한 품질 모니터링기법의 개발)

  • Cho, Sang Myung;Son, Min Su;Park, Jung Hyun
    • Journal of Welding and Joining
    • /
    • v.31 no.6
    • /
    • pp.90-95
    • /
    • 2013
  • Pipe inside clad welding is mainly used to the flow pipe of sub-sea or chemical plant. For the inside clad welding to the medium pipe with the diameter of about 12", TIG welding is frequently applied with filler metal. In this case, the clad welding has the very broad weld area over $10m^2$. And, the non-destructive test (NDT) such as ultrasonic test (UT) or radiographic testing (RT) should be conducted on the broad weld area, and it costs very high due to the time-consuming work. Therefore, the present study investigated the variation of arc voltage to develop the in-line quality monitoring system for the pipe inside TIG cladding. The 4 experimental parameters (current, arc length, wire feed position, and shield gas flow rate) varied to observe the change of arc voltage and to establish the model for the monitoring. The arc voltage was decreased when the wire was fed to the backward eccentric position(over 2mm), and the shield gas flow rate was insufficient under 10L/min. In the case of the backward eccentric position over 2mm, the bead appearance was not good and the dilution ratio was increased due to deep penetration. When the shield gas flow rate was lower than 10L/min, the bead surface was oxidized.

Effect of bond slip on the performance of FRP reinforced concrete columns under eccentric loading

  • Zhu, Chunyang;Sun, Li;Wang, Ke;Yuan, Yue;Wei, Minghai
    • Computers and Concrete
    • /
    • v.24 no.1
    • /
    • pp.73-83
    • /
    • 2019
  • Concrete reinforced with fiber reinforced polymer (FRP) bars (FRP-RC) has attracted a significant amount of research attention in the last three decades. A limited number of studies, however, have investigated the effect of bond slip on the performance of FRP-RC columns under eccentric loading. Based on previous experimental study, a finite-element model of eccentrically loaded FRP-RC columns was established in this study. The bondslip behavior was modeled by inserting spring elements between FRP bars and concrete. The improved Bertero-Popov-Eligehausen (BPE) bond slip model with the results of existing FRP-RC pullout tests was introduced. The effect of bond slip on the entire compression-bending process of FRP-RC columns was investigated parametrically. The results show that the initial stiffness of bond slip is the most sensitive parameter affecting the compression-bending performance of columns. The peak bond stress and the corresponding peak slip produce a small effect on the maximum loading capacity of columns. The bondslip softening has little effect on the compression-bending performance of columns. The sectional analysis revealed that, as the load eccentricity and the FRP bar diameter increase, the reducing effect of bond slip on the flexural capacity becomes more obvious. With regard to bond slip, the axial-force-bending-moment (P-M) interaction diagrams of columns with different FRP bar diameters show consistent trends. It can be concluded from this study that for columns reinforced with large diameter FRP bars, the flexural capacity of columns at low axial load levels will be seriously overestimated if the bond slip is not considered.