• Title/Summary/Keyword: Ecc

Search Result 604, Processing Time 0.027 seconds

Mechanical and Repair Performance of Sprayed Ductile Fiber Reinforced Cememtitious Composite(ECC) (습식스프레이공법으로 타설된 고인성 섬유보강 모르타르(ECC)의 역학적 특성과 보수 성능)

  • Kim, Yun-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.462-469
    • /
    • 2003
  • This paper presents an experimental study on the potential durability enhancement of infrastructures repaired by a sprayed high ductile fiber-reinforced cementitious composite (ECC). For this study, a PVA-ECC which exhibits sprayable properties in the fresh state and tensile strain-hardening behavior in hardened state was sprayed and tested. The experimental results show that the sprayed ECC exhibits mechanical properties with strain capacity comparable to the cast ECC with the same mix design. During loading, the crack widths of ECC are tightly controlled with an average of 30${\mu}m$. It is also revealed that when sprayed ECC is used as a repair material, ductility represented by deformation capacity at peak load of repaired beams in flexure are obviously increased in comparison to those of commercial prepackaged mortar (PM) repaired beams. In addition to high delamination resistance, the significant enhancement of energy absorption capacity and crack width control in ECC repair system suggest that sprayed ECC can be effective in extending the service life of rehabilitated infrastructures.

Flexural Behavior of Concrete-ECC Composite Beam Reinforced with Steel Rebar (철근 보강된 콘크리트-ECC 복합보의 휨 거동)

  • Hyun, Jung-Hwan;Bang, Jin-Wook;Lee, Bang-Yeon;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.104-111
    • /
    • 2020
  • The purpose of this study is to investigate the flexural behavior and plastic hinge of reinforced concrete-ECC composite beams. Ordinary portland cement was used as a binder, and high volume fly ash was also used to improve the properties of ECC. An ECC designed in this study showed high tensile strain capacity of 3.0%. Three types of beams were manufactured according to the replacement length of concrete with ECC. From the bending tests, it was found that load-bearing capacity as well as ductility of beam increased with an increase in the replacement length of concrete with ECC. Curvature ductility and plastic hinge length of beam were also increased.

An Experimental Study on the Durability and Load Carrying Capacity of RC Structure Repair System Using FR-ECC (고인성 내화보수모르터(FR-ECC)를 활용한 RC 구조물 보수공법의 내구성능 및 내하력에 관한 실험적 연구)

  • Kim, Jeong Hee;Lim, Seung Chan;Kim, Jae Hwan;Kwon, Yung Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.75-86
    • /
    • 2012
  • This paper presents some research results on the shrinkage characteristics and frost resistance before and after cracking of FR-ECC(Fire Resistance-Engineered Cementitious Composite). Also, a waterstop performance and exfoliating resistance of multi-layer lining specimens using FR-ECC and flexural performance of beam member by repaired FR-ECC are estimated in this paper. Experimental results indicate that the plastic shrinkage crack and length change ratio of FR-ECC have been reduced as compared with that of the existing repair mortar, and that its crack resistance on the dry shrinkage is improved under the confining stress. As well as FR-ECC has been great in the frost resistance and its tensile properties under the cracked state have been not reduced by freezing and thawing reaction. In addition, beam member by repaired FR-ECC have been increased in the flexural properties such as initial crack moment, yeild moment, and its crack width has been controled in a stable by the frexural failure.

A Study on a Shared Key Existence of ECC Based Key Distribution System (ECC 키분배에서 공유키 존재에 관한 연구)

  • Lee, Jun;Park, Jong-Bum
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.476-482
    • /
    • 2009
  • As a result from Hasse's theorem it is not always possible to share a common key between any two ECC public keys. Even though ECC algorithm is more efficient than any other Encryption's with respect to the encryption strength per bit, ECC ElGamal algorithm can not be used to distribute a common key to ECC PKI owners. Approaching mathematical ways in a practical situation, we suggest possible conditions to share a common key with ECC PKI's. Using computer experiments, we also show that these suggestions are right. In the conditions, we can distribute a common key to proper peoples with ECC ElGamal algorithm.

Repair Performance of Engineered Cementitious Composites(ECC) Treated with Wet-Mix Spraying Process

  • Kim, Yun-Yong
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.3E
    • /
    • pp.207-211
    • /
    • 2006
  • This paper presents an experimental study on the repair performance of sprayed engineered cementitious composites(ECC) serving as a repair material. Sprayable ECC, which exhibit tensile strain-hardening behavior in the hardened state and maintain sprayable properties in the fresh state, have been developed by using a parallel control of micromechanical design and rheological process design. The effectiveness of sprayable ECC in providing durable repaired structures was assessed by spraying the ECC and testing them for the assessment. The experimental results revealed that, when sprayed ECC were used as a repair material, both load carrying capacity and ductility represented by the deformation capacity at peak load of the repaired flexural beams were obviously increased compared to those of commercial prepackaged mortar(PM) repaired beams. The significant enhancement in the energy absorption capacity and tight crack width control of the ECC repair system treated with wet-mix spraying process suggests that sprayed ECC can be effective in extending the service life of rehabilitated infrastructures.

New Fire Resistant Methods of RC Structures Using ECC (구조물의 내화공법에 대한 ECC 적용 가능성)

  • Kim, Jung-Hee;Chun, Byung-Il;Lee, Myung-Ho;Chung, Jae-Min;Ahn, Sang-Ro
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.961-964
    • /
    • 2008
  • Fire safety is one of the important factors to be examined when applying ECC to actual concrete structures. The purpose of this study is to confirm whether the fire resistance of ECC satisfies the fire resistant requirements in order to use the fire protection material in concrete structures. Employed temperature curve are HC and RABT criterion, which are severe in various criterion of fire temperature in concrete structures. The test results show that ECC did not undergo any deterioration of fire resistance nor cause explosive spalling, which had been anticipated due to the presence of organic fibers. With comparison of current concrete and fire-resistance materials, the experimental results of ECC shows the better fire resistance performance than the other.

  • PDF

Compressive behavior of steel stirrups-confined square Engineered Cementitious Composite (ECC) columns

  • Zheng, Pan-deng;Guo, Zi-xiong;Hou, Wei;Lin, Guan
    • Advances in concrete construction
    • /
    • v.11 no.3
    • /
    • pp.193-206
    • /
    • 2021
  • Extensive research has been conducted on the basic mechanical property and structural applications of engineered cementitious composites (ECC). Despite the high tensile ductility and high toughness of ECC, transverse steel reinforcement is still necessary to confine ECC for high performance. However, limited research has examined performance of ECC confined with practical amount of transverse reinforcement. This paper presents the results of axial compression tests on 14 square ECC columns and 4 conventional concrete columns (used as control specimens) with transverse reinforcement. The test variables were spacing, configuration (square ties or square and diamond shape ties), and yield strength of stirrups. The test showed that ECC columns confined with steel stirrup had good compressive ductility, and the stirrup spacing had the greatest effect on the compressive performance. The self-confinement effect of ECC results in a more uniform but slower expansion of the whole column compared with CC ones. The test results are then compared against the predictions from a number of existing models for conventional confined concrete. It is indicated that these models fail to predict the axial strains at peak axial stress and the trend of the stress-strain curve of steel stirrups-confined ECC with sufficient accuracy. Several new equations are then proposed for the compressive properties of steel-confined ECC based on test results and potential approaches for future studies are proposed.

Tensile Stress-Strain Relation of ECC (Engineered Cementitious Composite) Accounting for Bridging Curve (실제 균열면응력-변위 곡선을 고려한 ECC의 1축 인장거동 관계)

  • Kim, Jeong-Su;Lee, Bang Yeon;Kwon, Seong-Hee;Kim, Jin-Keun;Kim, Yun Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.933-936
    • /
    • 2008
  • An engineered cementitious composite (Engineered Cementitious Composite) had been developed in previous study. Theoretical prediction of the tensile stress-strain relation of ECC is important in providing the material constitutive relation necessary for designing structural members. But, few studies have been reported with regard to predicting the tensile stress-strain relation of ECC. Prediction of the tensile stress-strain relation of ECC accounting for actual bridging curve, such as fiber dispersion is needed. The present study extends the work as developed by Kanda et al., by modeling the bridging curve, accounting for fiber dispersion, the degree of matrix spalling, and fiber rupture to predict the tensile stress-strain relation of ECC. The role of material variation in the bridging curve, such as number of effective fiber actually involved in the bridging capacity and how it affects the multiple cracking process is discussed. The approach for formulating the tensile stress-strain relation is discussed next, where the procedure for obtaining the necessary parameters, such as the crack spacing, is presented. Finally, the predicted stress-strain relation will be validated with experimental tests results.

  • PDF

Changes in Inflammatory Mediators, Immunocompetent Cells and Bone Merrow Progenitor Cells by the Magnitude of Muscle Damage and Type of the Muscle Contraction in the Elderly (고령자의 근육수축양식 및 손상정도에 따른 염증물질, 면역적격세포 및 골수유래 전구세포의 변화)

  • Song, Sang-Hyup;Lee, Ho-Seong
    • 한국체육학회지인문사회과학편
    • /
    • v.54 no.5
    • /
    • pp.769-780
    • /
    • 2015
  • This study investigated the changes in inflammatory mediators, immunocompetent cells and bone merrow progenitor cells by the magnitude of muscle damage and type of the muscle contraction in the elderly. Twenty older adults who had not been involved in a resistance-training program at least 6 months prior to the present study were assigned to eccentric exercise group (ECC, n=10) and concentric exercise group (CON, n=10). All subjects performed 10 sets of 6 maximal isokinetic eccentric (ECC 1) or concentric (CON) contractions with the non-dominant arm in a randomized, with 4 wk between bouts (ECC 2). Skeletal muscle damage index (ROM, VAS, Plasma CK), inflammation mediators (TNF-α, IL-1, IL-6), immunocomperent cells (CD3+, CD4+, CD8+, CD19+), bone merrow progenitor cell (CD34+) and leukocytes were measured before, immediately after, 2, 24, 48, 72, and 96 h after exercise. Changes in ROM and VAS were greater (P<.05) after ECC 1 than CON and ECC 2. Increases in TNF-α and IL-6 were greater (P<.05) 24, 48 and 72 h after ECC 1 than CON and ECC 2. Increases in neutrophils were greater (P<.05) 2 h after ECC 1 than CON and ECC 2. It was confirmed that muscle damage was greater following eccentric than concentric contractions as well as first bout than second bout in the elderly, and suggested that TNF-α, IL-6 and neutrophils should closely correlate with magnitude of muscle damage.

A Clinical Study of Changes in Serum Electrolyte Concentration During and After Extracorporeal Circulation with Heart-Lung Machine (심폐기 체외순환에 의한 혈청 전해질 변동에 관한 연구)

  • 김근호
    • Journal of Chest Surgery
    • /
    • v.11 no.4
    • /
    • pp.404-415
    • /
    • 1978
  • The present study was carried out to develop the better measures for safety of open heart surgery under extracorporeal circulation (ECC) with Heart-Lung-Machine by preventing changes in the concentrations of serum electrolytes during and after ECC. For this purpose, the cocentrations of serum electrolytes were measured before, during, and after ECC in 21 patients with congenital and acquired heart diseases who received open heart surger, - under ECC using Heart-Lung-Machine. Also considered was the development of safety measured by which changes in serum electrolyte concentrations were prevented during and after open heart surgery under ECC. The mean values for serum sodium levels were observed to be ; $13.14{\pm}0.47$mEq./L. for the samples obtained before ECC. $139.59{\pm}0.68$mEq./L. for the samples obtained 10 minutes after ECC and $138.0{\pm}0.68$mEq./L. for the samples obt"ined 24 hours after ECC. These results indicate that serum sodium concentrations were \\'ithin normal range during and until 24 hours after ECC. 2) The concentrations of serum chloride were found to be $105.38{\pm}0.70$105.38$\pm$0. 70 mEq./L. for the samples collected before ECC, $105.07{\pm}1.01$mEq./L. for the Simples collected 24 minutes aiter ECC and $101.95{\pm}1.09$mEq./L. for the samples collectect 24 hours afte ECC. As was tile case with serum sodium levels, no significant changes were observed in serum chloride levels during and 24 hours after ECC. 3)With proper provisions of potassium chloride solution during ECC, the concentrations of serum potassium were found to be $4.22{\pm}0.06$mEq./L. for the samples removed before EeC, $4.06{\pm}0.14$mEq./L. for the samples removed 10 minutes after ECC and $4.39{\pm}0.07$ mEq./L. for the samples removed 24 hours after ECC. 4)The concentrations of serum calcium were also maintained within normal during and after ECC; $9.15{\pm}0.14$mg/dl for the serum collected before ECC, $8.36{\pm}0.21$mg/dI for the serum collected 10 minutes after ECC and $8.47{\pm}0.14$mg/dl 21 hours after ECC. The maintenance of serum calcium level within normal throughout ECC was achieved by parenteral administrations of calcium gluconate as frequent as required. 5) As were the cases with serum potassium and calcium, the concentrations of plasma bicarbonate was regulated within normal range during and after ECC, only when sodium bicarbonate solution was admini"tered parenterally as it was required; $23.7{\pm}0.50$mEq./L. for the serum collected before ECC. $22.33{\pm}1.09$mEq.lL. for the serum collected 10 minutes after ECC and $25.3{\pm}0.96$mEq./L. for the serum collected 24 hours after ECC. The above results indicate tha t during and after ECC serum sodium and chloride levels remined unchanged without any provision of normal saline, while serum potassium, calcium, and bicarbonate concentrations were kept within normal limits only when these ealectrolytes were administered through parenteral routes. With these results it can be concluded that serum potassium, calcium, and bicarbonate levels should be determined as often as possible during and after ECC and that in order to maintain serum electrolyte levels within normal these electrolytes in the forms of potassium chloride, calcium gluconate, and sodium bicarbonate shou'd be given parenterally as they were found to be required.

  • PDF