• Title/Summary/Keyword: Earthquake level

검색결과 688건 처리시간 0.022초

국내 고층 비내진 철근콘크리트 벽식 아파트의 지진취약도 평가 (Seismic Fragility Assessment for Korean High-Rise Non-Seismic RC Shear Wall Apartment Buildings)

  • 전성하;신동현;박지훈
    • 한국지진공학회논문집
    • /
    • 제24권6호
    • /
    • pp.293-303
    • /
    • 2020
  • Seismic fragility was assessed for non-seismic reinforced concrete shear walls in Korean high-rise apartment buildings in order to implement an earthquake damage prediction system. Seismic hazard was defined with an earthquake scenario, in which ground motion intensity was varied with respect to prescribed seismic center distances given an earthquake magnitude. Ground motion response spectra were computed using Korean ground motion attenuation equations to match accelerograms. Seismic fragility functions were developed using nonlinear static and dynamic analysis for comparison. Differences in seismic fragility between damage state criteria including inter-story drifts and the performance of individual structural members were investigated. The analyzed building had an exceptionally long period for the fundamental mode in the longitudinal direction and corresponding contribution of higher modes because of a prominently insufficient wall quantity in such direction. The results showed that nonlinear static analyses based on a single mode tend to underestimate structural damage. Moreover, detailed assessments of structural members are recommended for seismic fragility assessment of a relatively low performance level such as collapse prevention. On the other hand, inter-story drift is a more appropriate criterion for a relatively high performance level such as immediate occupancy.

원전 적용을 위한 면진장치의 성능기반 설계 변위 추정 (Estimation of the Isolator Displacement for the Performance Based Design of Nuclear Power Plants)

  • 김정한;최인길;김민규
    • 한국지진공학회논문집
    • /
    • 제18권6호
    • /
    • pp.291-299
    • /
    • 2014
  • There has been an increasing demand for introducing a base isolation system to secure the seismic safety of a nuclear power plant. However, the design criteria and the safety assessment methodology of a base isolated nuclear facility are still being developed. A performance based design concept for the base isolation system needs to be added to the general seismic design procedures. For the base isolation system, the displacement responses of isolators excited by the extended design basis earthquake are important as well as the design displacement. The possible displacement response by the extended design basis earthquake should be limited less than the failure displacement of the isolator. The failure of isolators were investigated by an experimental test to define the ultimate strain level of rubber bearings. The uncertainty analysis, considering the variations of the mechanical properties of isolators and input ground motions, was performed to estimate the probabilistic distribution of the isolator displacement. The relationship of the displacement response by each ground motion level was compared in view of a period elongation and a reduction of damping. Finally, several examples of isolator parameters are calculated and the considerations for an acceptable isolation design is discussed.

A methodology to estimate earthquake induced worst failure probability of inelastic systems

  • Akbas, Bulent;Nadar, Mustafa;Shen, Jay
    • Structural Engineering and Mechanics
    • /
    • 제29권2호
    • /
    • pp.187-201
    • /
    • 2008
  • Earthquake induced hysteretic energy demand for a structure can be used as a limiting value of a certain performance level in seismic design of structures. In cases where it is larger than the hysteretic energy dissipation capacity of the structure, failure will occur. To be able to select the limiting value of hysteretic energy for a particular earthquake hazard level, it is required to define the variation of hysteretic energy in terms of probabilistic terms. This study focuses on the probabilistic evaluation of earthquake induced worst failure probability and approximate confidence intervals for inelastic single-degree-of-freedom (SDOF) systems with a typical steel moment connection based on hysteretic energy. For this purpose, hysteretic energy demand is predicted for a set of SDOF systems subject to an ensemble of moderate and severe EQGMs, while the hysteretic energy dissipation capacity is evaluated through the previously published cyclic test data on full-scale steel beam-to-column connections. The failure probability corresponding to the worst possible case is determined based on the hysteretic energy demand and dissipation capacity. The results show that as the capacity to demand ratio increases, the failure probability decreases dramatically. If this ratio is too small, then the failure is inevitable.

Necessity of management for minor earthquake to improve public acceptance of nuclear energy in South Korea

  • Choi, Hyun-Tae;Kim, Tae-Ryong
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.494-503
    • /
    • 2018
  • As public acceptance of nuclear energy in Korea worsens due to the Fukushima accident and the earthquakes that occurred in the Gyeongju area near the Wolsong nuclear power plant (NPP), estimating the effects of earthquakes has become more essential for the nuclear industry. Currently, most countermeasures against earthquakes are limited to large-scale disasters. Minor-scale earthquakes used to be ignored. Even though people do not feel the shaking due to minor earthquakes and minor earthquakes incur little damage to NPPs, they can change the environmental conditions, for instance, underground water level and the conductivity of the groundwater. This study conducted a questionnaire survey of residents living in the vicinity of an NPP to determine their perception and acceptance of plant safety against minor earthquakes. The results show that the residents feel earthquakes at levels that can be felt by people, but incur little damage to NPPs, as minor earthquakes (magnitude of 2.0-3.9) and set this level as a standard for countermeasures. Even if a minor earthquake has little impact on the safety of an NPP, there is still a possibility that public opinion will get worse. This study provides analysis results about problems of earthquake measures of Korean NPPs and specific things that can bring about an effect of deterioration of public acceptance. Based on these data, this article suggests that active management of minor earthquakes is necessary for the sustainability of nuclear energy.

통신장비의 내진안전성 시험평가절차 비교 (Comparison of the Earthquake Test Procedures for the Network Equipments)

  • 김영중
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.887-890
    • /
    • 2005
  • The earthquake test Procedures specified in three international codes were reviewed and compared for the network equipments. As technical level on the electronics and networking is growing in Korea, many related equipments are required to export to abroad. The network equipments are now essential tools for communication among individuals as well as societies, especially at the hazard situation such as earthquake strike. The Korean network companies are trying to improve the earthquake resistance performance for their products to expand domestic and international markets. In this paper it is reviewed that most codes related on the earthquake tests can be performed with the facilities provided in Korea for the network equipments. However new facility is required to prepare for more performance and higher regulating codes expected.

  • PDF

Eurocode 8에 의해 설계도니 건축물의 평가 (Evaluation of RC Building Structures Designed According to Eurocode 8)

  • 이한선
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall
    • /
    • pp.297-304
    • /
    • 1999
  • the devastating earthquake which occurred in Turkey on August 187, 1999, reminds again us the necessity of the preparedness for the earthquake hazard. the level of earthquake engineering in Koran is still low due to the short period of the research and development in this field. Therefore the most efficient way of promoting our technology in this field is considered to collect the information on the state of the art and practice developed in the advanced countries in earthquake engineering and to analyze the advantages and disadvantages and then reflect these to the new seismic codes. for this purpose this study reviews the concept and main characteristics of Eurocode 8 and the findings of many researches that have been performed for the improvement of EC8. Finally the seismic performance evaluation of the building structures designed according to EC8. and the relevant recommendations are summarized.

  • PDF

GNSS를 이용한 동일본대지진 이후 한반도 지각변동 해석 연구 (A Study on the Analysis of Crust Deformation on the Korean Peninsula after the Tohoku Earthquake using GNSS Observation)

  • 김희언;황의홍;이하성;이덕기
    • 한국측량학회지
    • /
    • 제38권6호
    • /
    • pp.689-696
    • /
    • 2020
  • 한반도 지각은 남동쪽으로 연평균 3cm의 속도로 이동하고 있다고 선행연구를 통해 알려져 있다. 2011년 동일본대지진에 의해 한반도 지각에는 큰 변동이 발생했다. 이후 한반도에서는 지진의 발생빈도가 증가하였다. 따라서 최근 15년간의 국내 및 국외 GNSS (Global Navigation Satellite System) 관측자료를 이용하여 동일본대지진 발생시점을 기준으로 한반도 지각변동 추세를 분석하였다. 자료처리는 전 세계적으로 많이 사용되고 있는 과학 기술용 소프트웨어 Bernese Software V5.2를 활용하였다. 그 결과 한반도는 동일본대지진 발생 전보다 이동 크기는 약 4mm, 이동 방향은 약 10° 차이가 발생했다. 한반도 내부 지각의 왜곡 현상은 동일본대지진 당시 한반도 지각의 동서 팽창 현상이 관측되었는데 최근까지 동일본대지진 이전의 수준으로 완전히 복귀하지 않은 것으로 판단된다.

붕괴방지 수준을 고려한 국내 고층 아파트의 성능기반 내진설계 (Performance-Based Seismic Design of High-rise Apartment Buildings in Korea Considering Collapse Prevention Level)

  • 이민희;유창환;김태진;김종호
    • 한국지진공학회논문집
    • /
    • 제20권3호
    • /
    • pp.181-190
    • /
    • 2016
  • The objective of this study is to apply performance-based seismic design to high-rise apartment buildings in Korean considering collapse prevention level. The possible issues during its application were studied and the suggestions were made based on the findings from the performance-based seismic design of a building with typical residential multi-unit layout. The lateral-force-resisting system of the building is ordinary shear walls system with a code exception of height limit. In order to allow the exception, the serviceability and the stability of the ordinary shear wall structure need to be evaluated to confirm that it has the equivalent performance as the one designed under the Korean Building Code 2009. The structure was evaluated whether it satisfied its performance objectives to withstand Service Level and Maximum Considered Earthquake.

일본의 지진방재·대응 시스템 분석을 통한 효과적인 우리나라 지진 R&D 전략 제언 (Suggestions for an Effective Earthquake R&D Strategy in Korea through an Analysis of Japan's Earthquake Disaster Prevention System)

  • 김성용;이재욱
    • 자원환경지질
    • /
    • 제53권3호
    • /
    • pp.321-336
    • /
    • 2020
  • 일본 지진방재 컨트롤타워는 지진조사연구추진본부이며, 산하의 정책위원회는 국가 종합기본시책과 조사관측계획을 수립하고 지진조사위원회는 각 지진방재 전문기관의 조사관측데이터와 연구성과를 취합하여 종합 검토평가를 한다. 일본의 지진방재·대응 시스템의 벤치마킹을 통한 우리나라에의 바람직한 시사점으로는 지진관련 지오-리질리언스 연구전략 구축이다. 지오-리질리언스 개념은 연구성과 실용화와 지질자원분야의 타 과학기술·인문사회분야와의 융합에 의한 재해복원능력 향상 역량을 의미하며, 주요 범위로는 국가 중장기 로드맵 전략연구, 지진예측연구, 지진재해 예측·경감기술개발, Geo-ICT 융합기술개발, Geo-사이버물리시스템 구현, 지구모방 기술개발 등과 지진발생지역 주민의 물리적, 심리적 치유관련 지질자원기술 관점 연구개발 등이다. 이를 통해, 국책전문연구기관은 재해발생 예측기술개발과 선제적 대응능력 강화, 지오데이터와 연구결과에 대한 지역사회의 신뢰도 제고와 차세대 인력양성, 관련 지진방재 인프라 확충 등이 가능할 것이다.

HAZUS틀을 사용한 서울시 강남구의 건축물 지진피해에 따른 직접적 경제손실 예측 (Earthquake Direct Economic Loss Estimation of Building Structures in Gangnam-Gu District in Seoul Using HAZUS Framework)

  • 정기현;이한선;권오성;황경란
    • 한국지진공학회논문집
    • /
    • 제20권6호
    • /
    • pp.391-400
    • /
    • 2016
  • For earthquake loss estimation of building structures in Gangnam-Gu district in Seoul, three scenario earthquakes were selected by comparison of the response spectra of these scenario earthquakes with the design spectrum in Korean Building Code (KBC 2009), and then direct losses of the building structures in the Gangnam-Gu district under each scenario earthquake are estimated. The following conclusions are drawn from the results of damage and loss in the second scenario earthquake, which has a magnitude = 6.5 and epicentral distance =15 km: (1) The ratio of building stocks undergoing the extensive and complete damage level is 40.0% of the total. (2) The amount of direct economic losses appears approximately 19 trillion won, which is 1.2% of the national GDP of Korea. (3) About 25% of high-rise (over 10-story) RC building wall structures, were inflicted with the damage exceeding moderate level, when compared to 60% of low-rise building structures. (4) From the economical view point, the main loss, approximately 50%, was caused by the damage in the high-rise RC wall building structures.