• Title/Summary/Keyword: Earth load

Search Result 452, Processing Time 0.028 seconds

Overturning Resistance of Plain Concrete Piers in OSPG Railroad Bridges

  • Rhee, In-Kyu;Park, Joo-Nam;Choi, Eun-Soo
    • International Journal of Railway
    • /
    • v.3 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • The steel plate-girder bridges with concrete gravity piers have possibilities of overturning by lateral inertial force which can be reproduced by sudden earthquake attack. This paper explores an overturning mechanism of existing concrete gravity pier onto the sandy soil in the event of lateral push-over load by in-situ experimental observation. The in-situ push-over experiment for pier with earth anchors between spread footing and rock beds exhibits a reasonable enhancement of ductility against overturning. In unanchored system, a flexural crack at cold joint of concrete pier is not developed because of the over-turning of the pier. This leads a global instability (rotation) of pier-footing system with relatively low stresses in pier itself. While a lateral load is persistently increased in anchored system, the successive flexural cracking failure at cold joint is observed even after the local shear failure of soil due to redistribution of stress equilibrium between soil and pier structure as long as a tensile action of anchor cable is active.

  • PDF

A study on horizontal stress of retaining walls caused by train loading (열차하중 작용 시 연직토류벽에 발생하는 수평응력 고찰)

  • Kim, Dae-Sang;Kim, Hyung-Geun;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.964-972
    • /
    • 2008
  • In the retaining wall design process, track and train loads are usually considered as uniform surcharge loads and strip loads. In this paper, the lateral(horizontal) earth pressure on retaining structures caused by track and train load are calculated using the Boussinesq solution. And also total horizontal force per unit length and the location of the resultant force were estimated with the changes of loading locations and widths of the loadings. The maximum horizontal earth pressure and the location of it for high-speed train load were 11.83kPa and 1.7m at the loading condition 2m away from retaining walls.

  • PDF

An Experimental Study on the Reinforcement Effect of Installed composite stiffener on Earth Retaining Walls using Stabilizing Piles (억지말뚝 흙막이공법에 설치된 복합버팀의 보강효과에 관한 실험적 연구)

  • Kim, Tae-Hyo;Im, Jong-Chul;Park, Lee-Keun;Kwon, Joung-Keun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1224-1239
    • /
    • 2008
  • The earth retaining walls using stabilizing piles can be applied to shallow excavation works without any stiffener. But, It demends a variety of installed composite stiffener on the earth retaining walls when it is installed as deep excavation works. Because, it causes an excessive displacement of walls. This research tried to overcome the problems created by the above issues and intended to apply the composite stiffener. The model test, focused on the effect of installed composite stiffener, measured the bending stress with stabilizing piles and walls, the settlement of earth surface, the displacement of walls for a step excavation and an increase in strip load. With the test results and soil deformation analysis, the reinforcement effect(relating to control displacement and earth presure) was analyzed in a qualitative and quantitative manner. It is expected to overcome a deep excavation works.

  • PDF

Discrete element numerical analysis for simulating trapdoor tests to assess loosening earth pressure on tunnel linings

  • Chaemin Hwang;Junhyuk Choi;Jee-Hee Jung;Hangseok Choi
    • Geomechanics and Engineering
    • /
    • v.38 no.6
    • /
    • pp.571-581
    • /
    • 2024
  • Concrete linings in tunnels constructed by drilling and blasting such as NATM serve as a secondary support structure. However, these linings can face unexpected earth pressures if the primary support deteriorates or if ground conditions become unfavorable. It is crucial to determine the loosening earth pressure that allows the lining to maintain its structural integrity and prevent damage caused by this pressure. This study proposes a numerical model for simulating the trapdoor test and developing a method for calculating the loosening earth pressure. The discrete element method (DEM) was employed to describe the soil characteristics around the tunnel. Using this numerical model, a sequence of experimental trapdoor steps was simulated, and the loosening earth pressure was analyzed. Contact parameters were calibrated based on an analysis of a triaxial compression test. The reliability of the developed model was confirmed through a comparison between simulation results and laboratory test findings. The model was used to calculate the contact force applied to the trapdoor plate and to assess the settlement of soil particles. Furthermore, the model accounted for the soil-arching effect, which effectively redistributes the load to the surrounding areas. The proposed model can be applied to analyze the tunnel's cross-sectional dimensions and design stability under various ground conditions.

Study on Fresh Air Load Reduction System by Using Geothermal Energy - Effect on Thermal Characteristic arid Air Pattern of System by Opening Configuration - (지열을 이용한 공조외기부하저감 시스템에 관한 연구 -지하피트 공간 내의 개구부 형상이 시스템의 열적 특성 및 기류성상에 미치는 영향-)

  • Son Won-Tug;Lee Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1092-1100
    • /
    • 2004
  • This paper presents the effect of opening configuration on the thermal behavior and air pattern of earth tube system. The earth tube system is a fresh air load reduction system by using underground double floor space for air-conditioning. In order to analyze the effect of opening configuration on thermal performance of this system and air pattern in underground double floor space quantitatively, we used a model dealing with tree-dimensional profile of wind velocity and temperature in underground double floor space. In conclusion, it is confirmed that heat exchange of a fresh air is mainly performed with upper and lower wall in underground double floor space, and that heat exchange area increased by installing the opening near the wall.

Research of Load Reduction on Corrugated Steel Pipe Using EPS Block (EPS 블록을 이용한 파형강관의 하중저감에 관한 연구)

  • 김진만;조삼덕;최봉혁;오세용;백영식
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.1
    • /
    • pp.91-99
    • /
    • 2004
  • Researches on the induced trench method using compressible materials such as clay, mud, straw have been performed to reduce the load acting on buried conduits under a high fill in USA and Canada. And in-situ tests on load reductionmethod using EPS block as a compressible inclusion have been performed in Japan and Norway. Using a EPS block as a compressible materials can have various benefits such as cost-effective design, enlargement of safety and easy construction of structure under high fills. This paper analyzes the arching material function of EPS which can result in reduction of earth pressure by arching effect in Corrugated Steel Pipe. A series of tests were conducted to evaluate the reduction of earth pressure on conduits using EPS. Based on field test it is found that the magnitude of vertical earth pressure on conduits was reduced to about 35∼40% compared with conventional flexible conduit systems.

mprovement of Estimation Method of Load Capture Ratio for Design and Evaluation of Bio-retention LID Facility (생태저류지 LID 시설의 설계 및 평가를 위한 삭감대상부하비 산정방법 개선)

  • Choi, Jeonghyeon;Lee, Okjeong;Kim, Yongseok;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.6
    • /
    • pp.569-578
    • /
    • 2018
  • To minimize the negative alterations in hydrologic and water quality environment in urban areas due to urbanization, Low Impact Development (LID) techniques are actively applied. In Korea, LID facilities are classified as Non-point Pollution Reduction Facilities (NPRFs), and therefore they are evaluated using the performance evaluation method for NPRFs. However, while LID facilities are generally installed in small, distributed configuration and mainly work with the infiltration process, the existing NPRFs are installed on a large scale and mainly work with the reservoir process. Therefore, some limitations are expected in assessing both facilities using the same method as they differ in properties. To solve these problems, in this study, a new method for performance evaluation was proposed with focus on bio-retention LID facilities. EPA SWMM was used to reproduce the hydrologic and water quality phenomena in study area, and SWMM-LID module used to simulate TP interception performance by installing a bio-retention cell under various conditions through long-term simulations. Finally, an empirical formula for Load Capture Ratio (LCR) was derived based on storm water interception ratio in the same form as the existing method. Using the existing formula in estimating the LCR is likely to overestimate the performance of interception for non-point pollutants in the extremely low design capacity, and also underestimate it in the moderate and high design capacity.

Analysis of the Rotational Behavior of Piles under Lateral Loading Installed in Multi Layered Soil (다층지반에 근입된 수평재하 말뚝의 회전거동 분석)

  • Kang, Beong-Joon;Kyung, Doo-Hyun;Hong, Jung-Moo;Lee, Jun-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.1
    • /
    • pp.55-64
    • /
    • 2009
  • One of the important use of piles is to furnish lateral support and nowadays it is getting highlighted due to the increase of skyscrapers, transmission towers, wind turbines, and other lateral action dependent structures. After Broms (1964), many researchers have suggested methods for estimating lateral capacity of pile. But each method assumes different earth pressure distribution and lateral earth pressure coefficient causing confusion on the part of pile designers. Lateral earth pressure, essential in lateral capacity estimation, is influenced by pile's rotational behavior under lateral load. Prasad and Chari (1999) assumed the rotation point of pile and suggested an equation of ultimate lateral load capacity. In this study, we investigate the depth of rotation point in both homogeneous soil and multi layered soil, and compare with the estimation value by previous research. Test results show that measured rotation point and estimated value by Prasad and Chari's equation show good agreement and multi layered condition affects the location of rotation point to be changed.

Effects of roughage quality, period of day and time lapse after meal termination on rumen digesta load in goats and sheep

  • Moyo, Mehluli;Adebayo, Rasheed Adekunle;Nsahlai, Ignatius Verla
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.8
    • /
    • pp.1183-1196
    • /
    • 2018
  • Objective: This study ascertained effects of roughage quality, period of day at meal termination and time lapse after feeding on digesta load in the rumen. Methods: Veld hay was untreated (poor roughage quality, PRQ), improved (improved roughage quality, IRQ) by treating with urea or semi-improved by spraying with urea (semi-improved roughage quality, SIRQ). Experiment 1a used four rumen fistulated sheep to determine in-sacco degradability. Twelve sheep ($56.3{\pm}4.59kg$) were blocked by weight and randomly allocated to IRQ (n = 6) and PRQ (n = 6) to determine solid and liquid passage rates. In experiment 1b, nine sheep ($37.6{\pm}9.34kg$) were blocked by weight and randomly allocated to IRQ (n = 4) and PRQ (n = 5) to determine digestibility. Sixteen sheep ($36.47{\pm}9.46kg$) were blocked by body weight and randomly allocated to IRQ (n = 8) and PRQ (n = 8). Two sheep were slaughtered for each sampling time in each treatment (IRQ and PRQ) at 0, 6, 12, and 24 h after feeding to determine rumen load. In experiment 2, eighteen goats ($25.4{\pm}9.08kg$) were blocked by weight and randomly allocated to IRQ (n = 6), SIRQ (n = 6), and PRQ (n = 6). Then all 18 goats were slaughtered soon after meal termination in the morning; afternoon and evening to determine the effect of period of day on rumen fill. Results: Rate of degradation and effective degradability were enhanced by improvement of roughage quality. Roughage quality had no effect on digestibility, but digestibility was higher in goats than sheep. Fractional passage rate of particles was higher for IRQ than PRQ, but similar for liquids. Digesta fractional clearance rates at 24 h after feeding were 0.018/h (IRQ) and 0.006/h (PRQ). Period of day had an influence on rumen load. Neutral detergent fibre load for goats were above 2.03 kg/100 kg body weight for all diet treatments. Conclusion: Following starvation, passage rate had negligible effects on emptying of rumen load.

A study on eccentric load acted on cut and cover tunnel by numerical approach (복개 터널구조물에 작용하는 편토압 고려를 위한 수치해석적 연구)

  • Bae, Gyu-Jin;Chung, Hyung-Sik;Lee, Gyu-Phil
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.3
    • /
    • pp.227-239
    • /
    • 2003
  • For environment-friendly construction, cut-and-cover tunnels have been constructed, thereby leading to embankment slopes with a number of steps. The slopes cause eccentric load on concrete lining of the tunnel. Nevertheless, uniform vertical and horizontal earth pressures, which are determined by considering a self-weight of embankment and $K_0$, are routinely used in structural calculation. Distribution of the earth pressures applied to the lining will lead to a biased calculation far from the actual behavior of the lining. In this study, basic study, therefore, was performed to consider the eccentric load properly in design and analysis of a cut-and-cover tunnel. A method capable of considering the eccentric load in design was proposed and its applicability was numerically examined through a number of examples.

  • PDF