• Title/Summary/Keyword: Earth fault

Search Result 428, Processing Time 0.023 seconds

ANALYSIS OF THE CHARACTERISTICS ABOUT GYEONG-GANG FAULT ZONE THROUGH REMOTE SENSING TECHNIQUES

  • Hwang, Jin-Kyong;Choi, Jong-Kuk;Won, Joong-Sun
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.196-199
    • /
    • 2008
  • Lineament is defined generally as a linear feature or pattern on interpretation of a satellite image and indicates the geological structures such as faults and fractures. For this reason, a lineament extraction and analysis using remote sensing images have been widely used for mapping large areas. The Gyeong-gang Fault is a NNE trending structure located in Gangwon-do and Kyeonggi-do district. However, a few geological researches on that fault have been carried out and its trace or continuity is ambiguous. In this study, we investigate the geologic features at Gyeong-gang Fault Zone using LANDSAT ETM+ satellite image and SRTM digital elevation model. In order to extract the characteristics of geologic features effectively, we transform the LANDSAT ETM+ image using Principal Component Analysis (PCA) and create a shade relief from SRTM data with various illumination angles. The results show that it is possible to identify the dimensions and orientations of the geologic features at Gyeong-gang Fault Zone using remote sensing data. An aerial photograph interpretation and a field work will be future tasks for more accurate analysis in this area.

  • PDF

Geophysical Responses of the Yangsan Fault Zone at Eonyang Area (언양 일대 양산단층에서의 지구물리학적 반응)

  • Kwon Byung-Doo;Lee Heuisoon;Lee Choon-Ki;Park Gyesoon;Oh Seokhoon;Lee Duk Kee
    • Journal of the Korean earth science society
    • /
    • v.26 no.5
    • /
    • pp.436-442
    • /
    • 2005
  • We have performed multiple geophysical surveys comprised of gravity, magnetic and resistivity methods at the Yangsan fault zone which runs through the Eonyang area, the eastern part of Kyeongsang in southeast Korea. The gravity and magnetic data provide information about geological structures. Furthermore, sections of electrical resistivity show the sharp contrast of electrical resistivity distribution across the fault zone. Since the fractured zone tends to be more conductive than fresh host rocks, the electrical resistivity survey is effective in determining the detailed structure of the fault zone. We have made gravity measurements at a total of 71 points alongside two profiles across the fault zone, and carried out an electrical resistivity survey with a dipole-dipole array at the same location using 40m dipole length. In addition, we have analyzed the aeromagnetic data on the corresponding area. The multiple geophysical properties appear to be abruptly changed in electrical resistivity, gravity and aeromagneticclearly show the different appearance across the fault zone. The fault is identified by its sub vertical attitude which is well known in the Yangsan fault zone. We have also confirmed that the magnitude of the response of the fault is much larger in the southern part of the survey area than the northern area. These results most likely to provide basic information for the further studies about the physical properties and the structures at the Yangsan fault.

Feasibility Studies of DInSAR in the Northeastern Kyungsang Basin, Korea

  • Lee, C.W.;Kim, S.W.;Jung, H.C.;Won, J.S.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1070-1072
    • /
    • 2003
  • This study focuses on examing the feasibility of differential SAR interferometry (DInSAR) in the Northeastern Kyungsang Basin, Korea. Major faults in the Kyungsang Basin such as Yangsan fault, Dongrae fault, and Ulsan fault had developed during Cretaceous, and the activeness of these faults is still controversial in Korean geology community. We attempt to measure displacements in the study area by applying DInSAR techniques to JERS-1 SAR data sets. Some surface displacements are recognized by DInSAR method at Young-il Bay in which the POSCO Company locates, although the displacements may not be directly associated with geologic structures. We also discuss atmospheric effects for the techniques used.

  • PDF

Coulomb stress transfer due to reverse faulting displacement field (역단층성 변위에 의한 Coulomb stress transfer)

  • Ko, Min-Suk;Chang, Chan-Dong;Lee, Jun-Bok;Shim, Taek-Mo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.149-154
    • /
    • 2008
  • We analyzed the Coulomb stress transfer near a small-scale reverse fault. For the modeling we used the geometry of a Quaternary fault in Gyeongju area, Eupcheon fault. For an assumed reverse faulting slip of 10cm, the resulting values of the Coulomb stress change are relatively higher (>2 bar) near the edges (both downward and lateral) of the fault, and diminish slightly upward and downward. The equivalents are negative in the zone immediately below and above the fault, exhibiting a "T" shape of low stress zone in the vertical profile of the fault. This study demonstrates the possible ranges and directions the aftershock energy would propagates after a reverse faulting.

  • PDF

Relation of Intensity, Fault Plane Solutions and Fault of the January 20, 2007 Odaesan Earthquake (ML=4.8) (2007년 1월 20일 오대산 지진(ML=4.8)의 진도, 단층면해 및 단층과의 관계)

  • Kyung, Jai-Bok;Huh, Seo-Yun;Do, Ji-Yong;Cho, Deok-Rae
    • Journal of the Korean earth science society
    • /
    • v.28 no.2
    • /
    • pp.202-213
    • /
    • 2007
  • The Odaesan earthquake $(M_L=4.8)$ occurred near Mt. Odae, Jinbu-Myon, Pyongchang-Gun, Kangwon Province on January 20, 2007. It has a shallow focal depth about 10 km. Its felt area covers most of the southern peninsula except some southern and western inland area. The maximum MM intensity was VI in the areas including Jinbu, Doam, Kangreung, Jumunjin, and Pyongchang. In these areas, there was a very strong shaking that caused several cracks on the walls of buildings and houses, slates falling off the roof, tiles being off the wall, things falling off the desk, and rock falling from the mountains. In order to get fault plane solutions, grid searches were performed by fitting distributions of P-wave first-motion polarities and SH/P amplitude ratios for each event. The results showed that the main shock represented right-lateral strike-slip sense and two aftershocks, reverse sense. It seems that the seismogenic fault may be the NNE-SSW trending Weoljeongsa fault near the epicenter based on the distribution of epicenters (foreshock, main shock, and aftershocks), damage area, and fault plane solution. The distribution of the epicenters indicates that the length of the subsurface rupture is estimated to be about 2 km.

Fault Plane Solutions for the June 26, 1997 Kyong-ju Earthquake (1997년 6월 26일 경주지진의 단층면해 비교해석)

  • Chung, Tae-Woong;Kim, Woo-Han
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.4
    • /
    • pp.245-250
    • /
    • 2000
  • By using amplitude ratios (SV/P, SH/P, SV/SH) and P and S wave polarities, we obtained fault plane solutions of the June 26, 1997 Kyong-ju earthquake. The solutions show $150{\pm}4^{\circ}$ in strike, $63{\pm}6^{\circ}$ in dip and $65{\pm}7^{\circ}$ in rake, or $18{\pm}12^{\circ}$ in strike, $26{\pm}3^{\circ}$ in dip and $120{\pm}5^{\circ}$ in rake. This result implies the stress field trending ENE-WSW, which is remarkably consistent with the previous results obtained from the moment tensor inversion, and from the composite fault plane solution for the events occurred around the Yangsan fault area.

  • PDF

A Study on the Sequence Impedance Modeling of Underground Transmission Systems (지중송전선로의 대칭분 임피던스 모델링에 관한 연구)

  • Hwang, Young-Rok;Kim, Kyung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.60-67
    • /
    • 2014
  • Power system fault analysis is commonly based on well-known symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. The majority of fault in transmission lines is unbalanced fault, such as line-to-ground faults, so that both positive and zero sequence impedance is required for fault analysis. When unbalanced fault occurs, zero sequence current flows through earth and ground wires in overhead transmission systems and through cable sheaths and earth in underground transmission systems. Since zero sequence current distribution between cable sheath and earth is dependent on both sheath bondings and grounding configurations, care must be taken to calculate zero sequence impedance of underground cable transmission lines. In this paper, EMTP-based sequence impedance calculation method was described and applied to 345kV cable transmission systems. Calculation results showed that detailed circuit analysis is desirable to avoid possible errors of sequence impedance calculation resulted from various configuration of cable sheath bonding and grounding in underground cable transmission systems.

FAULT DISPLACEMENT OF WENCHUAN EARTHQUAKE OBSERVED BY ALOS PALSAR

  • Won, Joong-Sun;Jung, Hyung-Sup
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.418-421
    • /
    • 2008
  • Wenchuan earthquake (Mw 7.9) occurred in Sichuan province, China, May 2008 had resulted in a huge fault displacement around the Lungmenshan fault. Preliminary results of the fault displacement observed by ALOS PALSAR interferometry are presented. The surface deformation by the Wenchuan earthquake was reported up to 10m consisting of thrust- and right-slip compnents. A significant reduction in ionospheric density was also reported. Twenty differential interferograms and twenty multiple aperture SAR interferometry (MAI) pairs were produced over four ALOS tracks. It was observed from differential interferograms that i) LOS deformation decreases steadily from northnorthwest of the Longmenshan fault to the fault, ii) the LOS deformation sharply increases at areas around the fault, and iii) the decrease of the LOS deformation is observed from the Longmenshan fault to the south-southeast of the fault. Horizontal movement of the reverse fault displacement can better be observed by MAI technique, and the MAI phases show that i) the south-southeast directional reverse fault displacement (negative along-track deformation for an ascending track) of the north-northwest block gradually increases to the Longmenshan fault, ii) the reverse fault movement of the south-southeast block is sharply reversed to the north-northwest of the fault, and iii) the northnorthwest movement gradually decreases to the south-southeast of fault. Although the Lonmenshan Fault line is a center of earthquake epicenter, the boundary of surface movement exists to the north-northeast of the fault. Since the ionosphere was not stable even forty days after the mainshock, MAI phases were seriously corrupted by ionospheric effect. It is necessary to acquire more data when the ionosphere recovered to a normal state.

  • PDF

Analysis of Fault Plane Solution and Stress Field Using the Micro-ewarthquakes in the Central Region of South Korea (남한 중부지역에서 발생한 미소지진의 단층면해와 응력장 해석)

  • Cheong, Tae-Woong;Lee, Jae-Gu;Lee, Duk-Kee;Lee, Eun-Ah;Kyung, Jai-Bok
    • Journal of the Korean earth science society
    • /
    • v.22 no.4
    • /
    • pp.292-300
    • /
    • 2001
  • By using two methods we obtained plane solutions for 5 groups of earthquakes including 13 events, which occurred in the central region of South Korea after December 1997. The first method is the composite fault plane solution by P wave polarity, and the second the solution by amplitude ratio (SV/P, SH/P, SV/SH) and P and S wave polarities. The two method results show similar results. The strike of fault is in the direction of NNE-SSW and WNW-ESE with the movement of strike-slip or strike-slip including thrust component. The compressional axis of the stress field dominantly trends ENE-WSW or NE-SW. The results are almost consistent with the other main events occurred in and around the Korean Peninsula.

  • PDF

Fault Management Design Verification Test for Electrical Power Subsystem and Attitude and Orbit Control Subsystem of Low Earth Orbit Satellite (저궤도위성의 전력계 및 자세제어계 고장 관리 설계 검증시험)

  • Lee, Sang-Rok;Jeon, Hyeon-Jin;Jeon, Moon-Jin;Lim, Seong-Bin
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.14-23
    • /
    • 2013
  • Fault management design of the satellite describes preparations for failures which can occur during operational phase. Fault management design contains detection and isolation function of anomaly, and also it contains function to maintain the satellite in safe condition until the ground station finds out a cause of failure and takes a countermeasure. Unlike normal operation, safing operation is automatically performed by Power Control and Distribution Unit and Integrated Bus Management Unit which loads Flight Software without intervention of ground station. Since fault management operation is automatical, fault management logic and functionality of relevant hardware should be thoroughly checked during ground test phase, and error which is similar to actual should be carefully applied without damage. Verification test for fault management design is conducted for various subsystems of satellite. In this paper, we show the design process of fault management design verification test for Electrical Power Subsystem and Attitude and Orbit Control Subsystem of Low Earth Orbit satellite flight model and the test results.