• Title/Summary/Keyword: Earth construction

Search Result 1,220, Processing Time 0.026 seconds

Dilatometer test for evaluating deformation characteristics in sand (사질토의 변형특성 평가를 위한 딜라토미터 시험의 활용)

  • Lee, Moon-Joo;Hong, Sung-Jin;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.241-252
    • /
    • 2010
  • This study investigates the application of dilatometer test for evaluating the deformation characteristics of granular soil. $K_D$ is the most sensitive to the stress history among CPT and DMT measurements, and $E_D$ and $q_c$ are observed to be similarly affected by the stress history. The coefficient of at-rest earth pressure($K_0$) is an indirect measure evaluating the stress history of granular soil. A relation using only DMT indices provides appropriate prediction of $K_0$ values. Although penetration of dilatometer inevitably induces the failure of cementation bonds, $E_D$ reflects the deformation characteristics of undamaged cementation relatively well. Therefore, a slightly better prediction of M value for cemented sand is achieved by using $E_D$ rather than $q_c$. Because of the weaker particle strength of calcareous sand compared than quartz sand, the majority of sand particles adjacent to dilatometer probe will be crushed during penetration. The particle crushing will induce the less contraction of the dilatometer membrane during penetration, consequently, the smaller $K_D$ and $E_D$ of calcareous sand.

  • PDF

Experimental Study for Determination of Horizontal Permeability with considering various Geocell Shapes (지오셀의 형상에 따른 수평투수계수 산정에 관한 실험적 연구)

  • Shin, Eun-Chul;Lee, Woon-Hyun;Kang, Hyoun-Hoi;Oh, Young-In
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.285-292
    • /
    • 2010
  • Recently, it is difficult to find a good soil ground due to the shortage of land for new construction site. Because of this situation, the geosynthetics are commonly used for reinforcing the substructure of the soil ground, and hence improving the bearing capacity and reducing the settlement. The geocell is one of geosynthetics and is the advanced system of geogrid. It is the way to increase earth strength and bearing capacity by using three dimension type of geocomposite. In this paper, the Horizontal permeability was determined with considering various geocell shapes. The permeability test was performed by following method of ASTM D4716(87) and potential filling material for geocell was used. The bearing capacity mechanism which enhances the soil ground with evenly maintaining the degree of the compaction was also analyzed for geocell reinforced ground.

  • PDF

Finite Element Analysis of Engineering Restoration of Dry Stone Wall Foundations (석조문화재 기초부의 공학적 복원을 위한 유한요소법 해석)

  • Kim, Sung-Su;Jung, Young-Hoon;Kim, Soo-Il;Lee, Kwang-Wu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1130-1141
    • /
    • 2010
  • Even though a number of historic structures in Korea need to be repaired, an intensive research on their engineering performance has rarely been investigated. Herein, we attempted to provide a methodological approach via the explicit finite element analysis to investigate geotechnical aspect of the performance of the dry-stone wall structures. To do so, we summarized relevant literature on the world-wide historic stone structures as well as its analysis in terms of modern geotechnical engineering. The method of the explicit finite element analysis has been briefly summarized. The numerical results on an idealized block structure show that the displacement of blocks and the distribution of earth pressure is different from the conventional theory of the retaining wall because of the discrete nature of the dry-stone wall structure.

  • PDF

In-orbit performance prediction for Amon-Ra energy channel instrument

  • Seong, Se-Hyun;Hong, Jin-Suk;Ryu, Dong-Ok;Kim, Sug-Whan
    • Bulletin of the Korean Space Science Society
    • /
    • 2011.04a
    • /
    • pp.30.2-30.2
    • /
    • 2011
  • In this report, we present in-orbit radiometric performance prediction for the Amon-Ra (Albedo Monitor and Radiometer) energy channel instrument. The Integrated Ray Tracing (IRT) computational technique uses the ray sets arriving at the Amon-Ra instrument aperture orbiting around the L1 halo orbit. Using this, the variation of flux arriving at the energy channel detector was obtained when the Amon-Ra instrument including the energy channel design observes the Sun and Earth alternately. The flux detectability was verified at the energy channel detector (LME-500-A, InfraTecTM). The detector time response and RMS signal voltage were then derived from the simulated flux variation results. The computation results demonstrate that the designed energy channel optical system satisfies the in-orbit detectability requirement. The technical details of energy channel instrument design, IRT model construction, radiative transfer simulation and output signal computation results are presented together with future development plan.

  • PDF

Sheath Circulating Current Analysis of a Crossbonded Power Cable Systems

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.320-328
    • /
    • 2007
  • The sheath in underground power cables serves as a layer to prevent moisture ingress into the insulation layer and provide a path for earth return current. Nowadays, owing to the maturity of manufacturing technologies, there are normally no problems for the quality of the sheath itself. However, after the cable is laid in the cable tunnel and is operating as part of the transmission network, due to network construction and some unexpected factors, some problems may be caused to the sheath. One of them is the high sheath circulating current. In a power cable system, the uniform configuration of the cables between sections is sometimes difficult to achieve because of the geometrical limitation. This will cause the increase of sheath circulating current, which results in the increase of sheath loss and the decrease of permissible current. This paper will study the various characteristics and effects of sheath circulating current, and then will prove why the sheath current rises on the underground power cable system. A newly designed device known as the Power Cable Current Analyser, as well as ATP simulation and calculation equation are used for this analysis.

Influence of Major Urban Construction on Atmospheric Particulates and Emission Reduction Measures

  • Wang, Shunyi;Zhou, Ping;Lin, Limin;Liu, Chuankun;Huang, Tao
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.215-231
    • /
    • 2018
  • In order to understand the variation of air quality and the concentration of atmospheric particulates in Chengdu Second Ring Road renovation project, this paper starts to investigate the surrounding residents' opinions on the influenced environment and their daily lives via questionnaires. Then the study numerically simulates the change rule of atmospheric particulates in terms of time and space by using the Gaussian dispersion-deposition model and the compartment model. The optimized scientific scheme is selected by the improved fuzzy analytical hierarchy process(FAHP) to help decision making for the future urban reconstructions. Finally, the reduced emissions of atmospheric particulates are measured when the improvement scheme is provided. According to the study, it can be concluded that the concentration of atmospheric particulates increases rapidly in central Chengdu city during the renovation project, which results in worsening air quality in Chengdu during March 2012 to March 2013. Taking related measures on energy saving and emission reduction can effectively reduce the concentration of atmospheric particulates and promote economic, environmental and social coordination.

The Analysis of Evaluation Items of Korea Green Building Certification Criteria in Office Building - Focusing on the Case Study of Office Building Certificated by GBCC from 2010 to 2012 - (국내 업무시설 부문의 친환경건축물 인증 평가항목 분석 - 2010년~2012년 국내 친환경 인증 업무시설의 사례 분석을 중심으로 -)

  • Kim, Chang-Sung
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.2
    • /
    • pp.11-19
    • /
    • 2013
  • Korea Government have carried out various policies to save the Earth environment from global warming and environmental pollution. It has also executed the Green Building Certification Criteria(GBCC) in 2002. The GBCC of office building was executed in 2003 and was revised twice in 2010 and 2011. Concerns about green building construction were quite increasing to keep the building performances sustainable. The aims of this paper is to check the reliability of weighting factors and scoring difficulties in all assessment categories of GBCC and to suggest the amendment direction of the future assessment criteria for green building. For the study, the old and new version of GBCC were examined to present the revision direction of GBCC and the 10 cases certificated by the old and new version, respectively 5 were analysed to compare with the difficulties in obtaining the certification. According to the results of the study, the GBCC requires additional amendments about the assessment categories of the energy consumption monitoring and the building commissioning as required subjects in order to secure the building performances. In addition, the operation mamagement of the building need to be assessed more intensively.

Analysis on Installation Conditions Survey and Improvement of Drain Pump in Air-Conditioner : Focusing on Changwon City (에어컨 배수펌프 설치 실태 및 개선방안 분석 - 창원시를 중심으로)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.102-106
    • /
    • 2012
  • This paper was carried out to survey fire hazard and improvement at the drain pump in air-conditioners. Based on the results of analysis, the proposal of electrical accidents prevention and a construction improvement are as follows. A power connection of the drain pump has two types, an electrical outlet type and direct connection type at control board of air-conditioner. The electrical outlet types need a bulletin sign or education as malfunction of the drain pump include an additional accidents, current leakage and overflowing with water on the floor from breaker trip by exterior cause and breaker off by mistake of worker. On the other hand, the direct connection types prevent a power interruption as exterior cause, but it has some trouble, cut of ground cable and without protection device. Usually it doesn't work by electrician when air-conditioner and the drain pump power work. Therefore an education or countermeasures are recommended for not electrician. Generally malfunction of the drain pump causes accumulated materials into the tank. Even though the accumulated materials lead to an overheating and burning as failure of detector occur an idling, periodic inspection of the air-conditioner filter and the drain pump tank prevent the trouble.

A Study on the Leakage Interception Work in the Irrigation Canal Founding on the Sandy Gravel or the Porous Soil (모래자갈과 누수성 토질을 기반으로하는 용수로의 누수방지에 대한 연구)

  • 강신업
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.12 no.2
    • /
    • pp.1965-1970
    • /
    • 1970
  • The experiment was carried out in order to improve the leakage stopping work in the irrigation canal founding on the porous soil. But the experiment had many problems to be studied more owing to the insufficient time and facilities. The results obtained are summarized as follows; 1. Polyethylene film is estimated not to make strength decrease owing to buring in the subsoil, but to make owing to the sunlight. 2. Coated nylon shows the tendency to deteriorate strength when it is buried in the earth or exposed to the sun for long time, but leakage is all but impermeability generally. 3. Leakage loss rates for one hour show some differences in the canal to be full with water in accordance with operating methods, that is, the clay lining section is 12.6%, the coated nylon lining section is 1.7%, the polyethylene film lining section is 1.3%, respectively. 4. Leakage quantities per wetted perimeter unit area show $3.556cc/cm^2/hr$. in the clay lining section, $1.574cc/cm^2/hr$. in the coated nylon section, $0.695cc/cm^2/hr$. in the polyethylene film lining section, respectively. 5. When the construction fund make the clay lining section as a standard, the polyethylene film section is 92.1%, the coated nylon section is 174.2%, respectively. But, the unit cost of execution may be low when the polyethylene film and the coated nylon will enable to mass-produce for the purpose of execution.

  • PDF

Experimental Sensitivity Table Method for Precision Alignment of Amon-Ra Instrument

  • Oh, Eunsong;Ahn, Ki-Beom;Kim, Sug-Whan
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.3
    • /
    • pp.241-246
    • /
    • 2014
  • The Amon-Ra instrument is the main optical payload of the proposed EARTHSHINE satellite. It consists of a visible wavelength instrument and an IR energy channel instrument to measure a global Earth albedo. We report a new sensitivity technique for efficient alignment of the visible channel instrument. Whilst the sensitivity table method has been widely used in the alignment process, the straightforward application of the method tends to produce slow process convergence because of shop floor alignment practice uncertainties. We investigated the error sources commonly associated with alignment practices and used them when estimating the Zernike polynomial coefficients. Aided with single center field wavefront error (WFE) measurements and their corresponding Zernike polynomial coefficients, the method involves the construction and use of an experimental, instead of simulated, sensitivity table to be used for alignment state estimations. A trial alignment experiment for the Amon Ra optical system was performed and the results show that 71.28 nm in rms WFE was achieved only after two alignment iterations. This tends to demonstrate its superior performance to the conventional method.