• Title/Summary/Keyword: Earth construction

Search Result 1,229, Processing Time 0.024 seconds

EPB tunneling in cohesionless soils: A study on Tabriz Metro settlements

  • Rezaei, Amir H.;Shirzehhagh, Mojtaba;Golpasand, Mohammad R. Baghban
    • Geomechanics and Engineering
    • /
    • v.19 no.2
    • /
    • pp.153-165
    • /
    • 2019
  • A case study of monitoring and analysis of surface settlement induced by tunneling of Tabriz metro line 2 (TML2) is presented in this paper. The TML2 single tunnel has been excavated using earth pressure balanced TBM with a cutting-wheel diameter of 9.49 m since 2015. Presented measurements of surface settlements, were collected during the construction of western part of the project (between west depot and S02 station) where the tunnel was being excavated in sand and silt, below the water table and at an average axis depth of about 16 m. Settlement readings were back-analyzed using Gaussian formula, both in longitudinal and transversal directions, in order to estimate volume loss and settlement trough width factor. In addition to settlements, face support and tail grouting pressures were monitored, providing a comprehensive description of the EPB performance. Using the gap model, volume loss prediction was carried out. Also, COB empirical method for determination of the face pressure was employed in order to compare with field monitored data. Likewise, FE simulation was used in various sections employing the code Simulia ABAQUS, to investigate the efficiency of numerical modelling for the estimating of the tunneling induced-surface settlements under such a geotechnical condition. In this regard, the main aspects of a mechanized excavation were simulated. For the studied sections, numerical simulation is not capable of reproducing the high values of in-situ-measured surface settlements, applying Mohr-Coulomb constitutive law for soil. Based on results, for the mentioned case study, the range of estimated volume loss mostly varies from 0.2% to 0.7%, having an average value of 0.45%.

Compacted expansive elastic silt and tyre powder waste

  • Ghadr, Soheil;Mirsalehi, Sajjad;Assadi-Langroudi, Arya
    • Geomechanics and Engineering
    • /
    • v.18 no.5
    • /
    • pp.535-543
    • /
    • 2019
  • Building on/with expansive soils with no treatment brings complications. Compacted expansive soils specifically fall short in satisfying the minimum requirements for transport embankment infrastructures, requiring the adoption of hauled virgin mineral aggregates or a sustainable alternative. Use of hauled aggregates comes at a high carbon and economical cost. On average, every 9m high embankment built with quarried/hauled soils cost $12600MJ.m^{-2}$ Embodied Energy (EE). A prospect of using mixed cutting-arising expansive soils with industrial/domestic wastes can reduce the carbon cost and ease the pressure on landfills. The widespread use of recycled materials has been extensively limited due to concerns over their long-term performance, generally low shear strength and stiffness. In this contribution, hydromechanical properties of a waste tyre sand-sized rubber (a mixture of polybutadiene, polyisoprene, elastomers, and styrene-butadiene) and expansive silt is studied, allowing the short- and long-term behaviour of optimum compacted composites to be better established. The inclusion of tyre shred substantially decreased the swelling potential/pressure and modestly lowered the compression index. Silt-Tyre powder replacement lowered the bulk density, allowing construction of lighter reinforced earth structures. The shear strength and stiffness decreased on addition of tyre powder, yet the contribution of matric suction to the shear strength remained constant for tyre shred contents up to 20%. Reinforced soils adopted a ductile post-peak plastic behaviour with enhanced failure strain, offering the opportunity to build more flexible subgrades as recommended for expansive soils. Residual water content and tyre shred content are directly correlated; tyre-reinforced silt showed a greater capacity of water storage (than natural silts) and hence a sustainable solution to waterlogging and surficial flooding particularly in urban settings. Crushed fine tyre shred mixed with expansive silts/sands at 15 to 20 wt% appear to offer the maximum reduction in swelling-shrinking properties at minimum cracking, strength loss and enhanced compressibility expenses.

A Comparative Study on the Architetural Characteristics of Traditional Korean-Chinese and Chinese Dwellings of Sujoenchon Village in Jilin Province of Northeast China (중국(中國) 길림성(吉林省) 수전촌(水田村)의 조선족(朝鮮族) 주거(住居)와 한족(漢族) 주거(住居)의 비교(比較))

  • Lee, sang-hae
    • Korean Journal of Heritage: History & Science
    • /
    • v.34
    • /
    • pp.138-171
    • /
    • 2001
  • This paper, based on the filed survey conducted from August 14 to 21, 2000, examines the architectural characteristics of traditional dwellings of Sujeonchon(수전촌, 水田村) village. Sujeonchon village is located on the northen slope of Changbaishan Mt., Andohyun(안도현, 安圖縣) of jilin Province(吉林省), a province in the northeastern region of China. The village was established between late 1940's and early 1950's by the Korean-Chinese. Later on, some of the Korean-Chinese residents moved out of the village and presently, the residents are composed of both the Korean-Chinese and the Chinese consisting about fifty-fifty. Since the cultural background and the living custom are different from each other ethnic group, that is, the Korean-Chinese and the Chinese, their dwellings reveal some differences between them. Through the study, the architectural characteristics and distinctions of the Korean-Chinese and Chinese dwellings are found and summarized as follows: 1.The way of building layout is different between them: the Chinese mainly follows the north-south direction of building layout, while the Korean-Chinese considers the surrounding environmental condition. 2.The floor level of kitchen is different between them: that of the Chinese house is same as the outdoor earth level, while that of the Korean-Chinese is lower than the outdoor level. 3.The way of providing the kitchen space is different between them: the kitchen of the Chinese house is consist of one separate room, while that of the Korean-Chinese is open to the living area. 4.The way of heating system is different between them: the Chinese house has kang only at the sleeping area, while the Korean-Chinese install whole under-floor heating of gudeul in the living area. 5.The attitude to the way of building is different between them: the Chinese are easily adapt to the new building materials and construction method, while the Korean-Chinese are showing strong attachment to the traditional way of building. 6.The houses of the Chinese and the Korean-Chinese have their own traditional ornaments and talismans on and in the building.

A Study on the Open Cut Restoration of Underground Cavity Using Concrete Mat (콘크리트매트를 이용한 개착식 지반공동 복구방법에 관한 연구)

  • Park, Jeong-Jun;Shin, Heesoo;Chung, Yoonseok;You, Seung-Kyong;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.1
    • /
    • pp.55-65
    • /
    • 2019
  • This paper describes results of experimental and numerical analyses, in order to analyze a reinforcement effect of concrete mat on open cut restoration of underground cavity. The plate loading tests were conducted to evaluate a reinforcement effect of concrete mat, at reinforcement depths from the ground surface of 10 cm, 20 cm, and 30 cm. The result showed that the reduction ratio of stress (earth pressure) was about 60% at all reinforcement depth. The reinforcement effect considering ground surface settlement and reduction ratio of stress based on laboratory tests and numerical analysis was significant, at reinforcement depths from the ground surface of 10 cm~20 cm. LFWD test results showed that subgrade modulus was the largest when concrete mat was installed 20 cm below ground surface. Therefore, it is effective to reinforce concrete mat within 20 cm from the surface, when the underground cavity due to damage of underground utilities was formed in the height direction to the bottom of the pavement layer.

Determination of Hydrophyte Index of Native Plant on the Downstream Slope of Earth Fill Dam (필댐 하류사면 자생식물의 습생지수 결정)

  • Kim, Hyun Soo;Ryu, Bum Hee;Park, Seung Ki
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.1
    • /
    • pp.131-144
    • /
    • 2019
  • The purpose of study was to determine the hygrophyte index of each plant(HIP) considering the moisture environment condition (MEC) of the native plants on the downstream slope of the fill dam and evaluate its applicability which to develop a method to search for leaks and saturated zones of the fill dam for status evaluation of precision safety diagnosis. The HIP was weighted average and consisted of 19 ranks. The weighted average was calculated according to the following three procedures: First, the linear assumption was made according to the actual habitat environmental conditions, the second one was weighted to 10% of the optimal habitat condition, and finally the average value of the distribution range values. The Hygrophyte index of vegetation at each plot (HIV) was obtained from the Sinheung reservoir (Yesan-gun, Chungcheongnam-do) using the results of vegetation survey of the Sinheung reservoir with precision safety diagnosis and suggested the use of the hygrophyte index of the cultivated vegetation. The average HIP range of plant species that emerged in 50 survey sites on the downstream slope of the Sinheung reservoir is 2.99 to 3.56. The coefficient of variation showed a large difference depending on the appearance of the leakage indicator plant(LIP) species. The range of HIV is 2.80 to 4.26, the mean value is 3.37, standard deviation is 0.37 and the coefficient of variation is 9.7%. As a result, the value of the coefficient of variation showed a large difference depending on the appearance of the plant species.

Development of Optimum Design Method for Geothermal Performance based on Energy Simulation (지열 성능해석 시뮬레이션에 기반한 최적 설계 수법 개발)

  • Moon, Hyeongjin;Kim, Hongkyo;Nam, Yujin
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.3
    • /
    • pp.43-48
    • /
    • 2019
  • Since the revision of the Rationalization of Energy Use Law, the spread of new and renewable energy in buildings has been promoted. In addition, the production of electric power and thermal energy is an important issue in the change of energy paradigm centered on the use of distributed energy. Among them, geothermal energy is attracting attention as a high-performance energy-saving technology capable of coping with heating / cooling and hot water load by utilizing the constant temperature zone of the earth. However, there is a disadvantage that the initial investment cost is high as a method of calculating the capacity of a geothermal facility by calculating the maximum load. The disadvantages of these disadvantages are that the geothermal energy supply is getting stagnant and the design of the geothermal system needs to be supplemented. In this study, optimization design of geothermal system was carried out using optimization tool. As a result of the optimization, the ground heat exchanger decreased by 30.8%, the capacity of the heat pump decreased by 7.7%, and the capacity of the heat storage tank decreased by about 40%. The simulation was performed by applying the optimized value to the program and confirmed that it corresponds to the load of the building. We also confirmed that all of the constraints used in the optimization design were satisfied. The initial investment cost of the optimized geothermal system is about 18.6% lower than the initial investment cost.

A Study on the Applicaton of Electrical Resistivity Survey in the Contaminated Soil and Groundwater Site (토양 및 지하수 오염지역에 대한 전기비저항탐사의 적용성 연구)

  • Chae, Seungheon;Lee, Sangeun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.525-539
    • /
    • 2020
  • A site containing buried solid waste and treated water and oil storage containers from a leather manufacturing plant was studied through soil and groundwater pollution and electrical resistivity surveys with the aim of identifying areas polluted by leachate generated by landfilling with leather waste and leakage wastewater. It was found that TPH and Zn exceeded environmental standards for soil pollution and, for leachate and groundwater, Cr(VI) concentrations exceeded standard levels for groundwater quality. An electrical resistivity survey was used to elucidate soil and groundwater pollution characteristics and diffusion pathways. Ten survey lines were set up with an electrode spacing of 5 m in a dipole-dipole array. The hydraulic characteristics of soil determined by groundwater contamination surveys matched well the low-resistivity-anomaly zones. Electrical resistivity surveys of areas containing contaminated soil and groundwater that have irregular strata due to waste reclamation are thus useful in highlighting vertical and horizontal pollutant diffusion pathways and in monitoring contaminated and potentially contaminated areas.

A Consideration on the Causes of 22.9kV Cable Terminal Burning Accident (22.9kV 케이블 단말 부위 소손 사고의 원인에 관한 고찰)

  • Shim, Hun
    • Journal of Internet of Things and Convergence
    • /
    • v.8 no.2
    • /
    • pp.7-12
    • /
    • 2022
  • The main cause of cable accidents is the accelerated deterioration of the cable itself or internal and external electrical, mechanical, chemical, thermal, moisture intrusion, etc., which reduces insulation performance and causes insulation breakdown, leading to cable accidents. Insulation deterioration can occur even when there is no change in the appearance of the cable, so there is a difficulty in preventing cable accidents due to insulation deterioration. Since cable accidents can occur in areas with poor insulation due to the effects of overvoltage and overcurrent, it is necessary to comprehensively analyze transformers and circuit breakers, and ground faults caused by phase-to-phase imbalance. Ground fault accidents due to insulation breakdown of cables can occur due to defects in the cable itself and poor cable construction, as well as operational influences, arcs during operation of electrical equipment (switchers, circuit breakers, etc.). analysis is needed. This study intends to examine the causes of cable accidents through analysis of cable accidents that occurred in a manufacturing factory.

Numerical evaluation of surface settlement induced by ground loss from the face and annular gap of EPB shield tunneling

  • An, Jun-Beom;Kang, Seok-Jun;Kim, Jin;Cho, Gye-Chun
    • Geomechanics and Engineering
    • /
    • v.29 no.3
    • /
    • pp.291-300
    • /
    • 2022
  • Tunnel boring machines combined with the earth pressure balanced shield method (EPB shield TBMs) have been adopted in urban areas as they allow excavation of tunnels with limited ground deformation through continuous and repetitive excavation and support. Nevertheless, the expansion of TBM construction requires much more minor and exquisitely controlled surface settlement to prevent economic loss. Several parametric studies controlling the tunnel's geometry, ground properties, and TBM operational factors assuming ordinary conditions for EPB shield TBM excavation have been conducted, but the impact of excessive excavation on the induced settlement has not been adequately studied. This study conducted a numerical evaluation of surface settlement induced by the ground loss from face imbalance, excessive excavation, and tail void grouting. The numerical model was constructed using FLAC3D and validated by comparing its result with the field data from literature. Then, parametric studies were conducted by controlling the ground stiffness, face pressure, tail void grouting pressure, and additional volume of muck discharge. As a result, the contribution of these operational factors to the surface settlement appeared differently depending on the ground stiffness. Except for the ground stiffness as the dominant factor, the order of variation of surface settlement was investigated, and the volume of additional muck discharge was found to be the largest, followed by the face pressure and tail void grouting pressure. The results from this study are expected to contribute to the development of settlement prediction models and understanding the surface settlement behavior induced by TBM excavation.

Occurrence of Radioactive Minerals and U-Th Geochemistry of the Weolaksan and Sokrisan Granite in the Central Ogcheon Belt (중부 옥천대 월악산과 속리산 화강암의 방사성 광물 산출상태와 U-Th 지구화학)

  • Hwang, Jeong
    • The Journal of Engineering Geology
    • /
    • v.32 no.2
    • /
    • pp.295-310
    • /
    • 2022
  • The Weolaksan and Sokrisan granites yield high SiO2 and alkali (Na2O+K2O) contents and low CaO and P2O5 contents. The Al saturation index is ≥1.3, which indicates that the granites are peraluminous. The mean U and Th contents are 8.3 and 39.3 ppm, respectively, higher than typical Mesozoic granites in South Korea and about twice the global mean for granitic rocks. The causes of such high radioelement contents are related to high degrees of fractionation and the crustal origin of the granites. U- and Thbearing radioactive minerals occur in the granites include zircon, thorite, monazite, xenotime, fergusonite and uraninite. The fact that the mean Th/U ratio of the granites (5.4) is similar to the global average crustal value suggests that the radioelement contents of granite were controlled by the crustal source material. Given the correlation of Zr, Y, and heavy rare earth elements for U and Th, radioelements are more likely hosted by xenotime than zircon and monazite.