• Title/Summary/Keyword: Earth Heat

Search Result 427, Processing Time 0.026 seconds

CENTRALLY PEAKED X-RAY SNRS : CLOUD EVAPORATION AND THERMAL CONDUCTION (X-선 중심 가광 초신성 잔해 : 성간운 증발과 열전도 모델)

  • CHOE SEUNG-URN;JUNG HYUN-CHUL;PARK BYEONG-GEON
    • Publications of The Korean Astronomical Society
    • /
    • v.14 no.2
    • /
    • pp.69-78
    • /
    • 1999
  • We present the results of one-dimensional numerical simulations of SNR evolution in the in­homogeneous medium considering the effects of the evaporation of the cloud and the thermal conduction. We have included the effects of changing evaporation rate as a function of cloud size and the ambient temperature so that the clouds could be evaporated completely before they reach the center of the SNR. The heat conduction markedly changes the density distribution in the remnant interior. To explain the observed morphologies of the centrally peaked X-ray SNRs(for example W44), the maximal thermal conduction is required. However, this is unlikely due to the magnetic field and the turbulent motion. The effects of the evaporation of the cloud and the thermal conduction described here may explain the class of remnants observed to have centrally peaked X-ray emmision.

  • PDF

A Study on the Correlation between Outdoor Air and Outlet Air Temperature in a Fresh Air Load Reduction System by Using Geothermal Energy (지열을 이용한 외기부하저감시스템의 외기온도와 출구온도의 상관관계 분석)

  • Son, Won-Tug;Park, Kyung-Soon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.620-627
    • /
    • 2010
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we investigated the correlation between outdoor air temperature and outlet air temperature in the system. In conclusion, from the results of the high correlation we proposed a equation of regression for the outlet air temperature in the system by using linear regression analysis.

A Study on the Simplified Presumption Method for the Prediction of Cooling and Heating Performance in a Fresh Air Load Reduction System by Using Geothermal Energy (지열 이용 외기부하 저감시스템의 냉각 및 가열효과 예측 간이추정법에 관한 연구)

  • Son, Won-Tug;Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.13 no.3
    • /
    • pp.169-181
    • /
    • 2010
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we proposed a simplified presumption method for the prediction of cooling and heating performance in the system. In conclusion the proposed method has been verified by comparing with the calculated value of the numerical analysis model by using nonlinear two-dimension hygroscopic question.

  • PDF

The development of a ground source heat pump using R410A (R410A 대체냉매 적용 지열히트펌프 개발)

  • Kim, Ji-Dong;Chung, Bong-Chul;Jeong, Il-Kwon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.3 no.1
    • /
    • pp.17-22
    • /
    • 2007
  • The growth of domestic energy demand is rapidly increased for the industrialization and the improvement of the living standards. It is also recognised that the importance of the use of environmentally friendly energy and high efficient equipment. Ground Source heat pumps (GSHP) using earth as heat source or sink are outstanding environmentally friendly energy systems which have high thermal efficiency when compared to conventional heating and cooling system. So government employs a policy and increase investment for expanding renewable energy market volume. Especially is established a system for obligatory usage of renewable energy to achieve 5% renewable energy diffusion rate by 2011. And the market demand for the ground source heat pump is rapidly growing due to its strong advantages. However domestic situation usually have been depended on the import of ground source heat pumps. In this paper, the results of development of a ground source heat pump using refrigerant R410A are reported.

  • PDF

Evaluation of Thermal Environments during the Heat Waves of Summer 2013 in Busan Metropolitan Area (2013년 부산지역 폭염사례일의 열쾌적성 평가)

  • Kim, Young-Jun;Kim, Hyunsu;Kim, Yoo-Keun;Kim, Jin-Kuk;Kim, Yeon-Mai
    • Journal of Environmental Science International
    • /
    • v.23 no.11
    • /
    • pp.1929-1941
    • /
    • 2014
  • Now a days, frequency of abnormally high temperatures like heat wave by global warming and climate change is increasing constantly and the number of patient with heat related illness are jumping rapidly. In this study, we chose the case day for the heat wave in Busan area(Busan and Yangsan), 2013 which it was the most hottest year during 21th century. And then, we analysed the weather condition using automatic synoptic observing system(ASOS) data. Also, four indices, heat index(HI), wet bulb globe temperature(WBGT), Man-ENvironment heat EXchange model(MENEX)'s results like Physiological subjective temperature(PST), Physiological strain(PhS), were calculated to evaluate the thermal comfort and stress quantitatively. However, thermal comfort was different as the each station and thermal comfort index during same time. Busan's thermal indices (HI: hot, WBGT: sweltering, PST: very hot, PhS: very hot) indicated relatively higher than Yansan's (HI: very hot, WBGT: sweltering, PST: very hot, PhS: sweltering). It shows that Busan near coast is relatively more comfortable than Yangsan located in inland.

A Study on Optimization of Thermophysiological Indices for Harbor Workers in Summer: Improvement of MENEX Model's Input Data Considering the Work Environment (하계 항만열환경지수 최적화 방안연구: 항만작업환경을 반영한 MENEX모델의 입력변수 개선)

  • Yun, Jinah;Hwang, Mi-Kyoung;Kim, Yoo-Keun
    • Journal of Environmental Science International
    • /
    • v.25 no.7
    • /
    • pp.951-961
    • /
    • 2016
  • To prevent increasing instances of heat-related illnesses due to heat waves generated by climate change, a customized thermal environment index should be developed for outdoor workers. In this study, we conducted sensitivity analysis of the Masan harbor during a heat wave period (August 9th to 15th, 2013) using the MENEX model with metabolic rate and clothing-insulation data, in order to obtain realistic information about the thermal environment. This study shows that accurate input data are essential to gather information for thermophysiological indices (PST, DhR, and OhR). PST is sensitive to clothing insulation as a function of clothing. OhR is more sensitive to clothing insulation during the day and to the metabolic rate at night. From these results, it appears that when exposed to high-temperature thermal environments in summer, wearing highly insulated clothing and getting enough rest (to lower the metabolic rate) can aid in preventing heat-related illnesses. Moreover, in the case of high-intensity harbor work, quantification of allowed working time (OhR) during heat waves is significant for human health sciences.

ANALYSIS OF THE OCEAN' AND ATMOSPHERE ROLES IN THEIR HEAT INTERACTION WITH USE OF SATELLITE AND VESSEL

  • Grankov, Alexander Georgievich;Mil'shin, Alexander Alexeevich;Krapivin, Vladimir Fedorovich;Golovachev, Sergey Petrovich
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.1001-1002
    • /
    • 2006
  • Special problem emphasized by specialists in the field of analyzing the heat interchanges in the system ocean-atmosphere (SOA) is a necessity of determination of the near-surface atmospheric temperature, which can be only indirectly connected with characteristics of the SOA natural microwave radiation measured from satellites. That is why, the following dilemma is not obvious, but interesting and promised: what is better - to use the satellite methods for retrieving the partial parameters of the SOA or for analysis its state as a whole. To our opinion, this task is similar to the idea recognized by specialists engaged in the heat infrared region (8-12 mcm) of electromagnetic spectrum and its applications, where an intensity of natural infrared radiation (effective radiation) is used as the inherent property (the attribute) of the SOA heat balance. Here we studied important aspects of this problem: a) what medium initiates a heat transfer in the SOA and disturbs its heat balance - the ocean or the atmosphere b) what SOA parameters directly influence on its natural microwave radiation intensity (brightness temperature) measured from satellites? We relate these processes mainly to the synoptic range of time scales enriched by various events in the SOA interface such as the mid-latitude and tropical cyclones.

  • PDF

The effect of step heat treatment in the critical current density of BSCCO 2223 tapes (BSCCO 2223선재의 임계전류밀도에 영향을 미치는 단계별 열처리의 효과)

  • 박성창;유재무;고재웅;김영국;김철진
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.90-93
    • /
    • 2002
  • The sintering process of BSCCO 2223 tapes is a complex process that is very sensitive to parameters, such as temperature, oxygen partial pressure, heating and cooling rate and holding time. During the first heat treatment, 2212 phase of precursor powder is partially transformed into 2223 phase and some residual secondary phases, such as $(Bi,Pb)_2$$Sr_2$CuO/sub y/(2201), $(Ca,Sr)_2$CuO/sub y/(2/1AEC), (Ca,Sr)/sub 14/Cu/sub 24/O/sub 41/(14/24 AEC) etc. The secondary phases are difficult to be removed from the BSCCO 2223 matrix on the heat treatment. These secondary phases degrade the critical current density. In order to minimize the amount and size of alkaline earth cuprate(AEC) particles step heat treatment is applied during the first heat treatment under the varying atmosphere. Experimental results showed that by adapting the step heat treatment process, the amount and particle size of the secondary phases in the final tapes are decreased. Consequently, the BSCCO 2223grain texture and Jc properties are improved.

  • PDF

The development of a ground source heat pump using R410A (R410A 대체냉매 적용 지열히트펌프 개발)

  • Kim, Ji-Dong;Chung, Bong-Chul;Jeong, Il-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.99-102
    • /
    • 2008
  • The growth of domestic energy demand is rapidly increased for the industrialization and the improvement of the living standards. It is also recognised that the importance of the use of environmentally friendly energy and high efficient equipment. Ground Source heat pumps(GSHP) using earth as heat source or sink are outstanding environmentally friendly energy systems which have high thermal efficiency when compared to conventional heating and cooling system. So government employs a policy and increase investment for expanding renewable energy market volume. Especially is established a system for obligatory usage of renewable energy to achieve 5% renewable energy diffusion rate by 2011. And the market demand for the ground source heat pump is rapidly growing due to its strong advantages. However domestic situation usually have been depended on the import of ground source heat pumps. In this paper, the results of development of a ground source heat pump using refrigerant R410A are reported.

  • PDF

Effect of Thermal Post-Treatment using the Black Body Networking of Carbon Nano Structure For Internal Conduction from Solar Radiation (태양복사열 내부전도 성능향상을 위한 탄소 나노구조체 흑체코팅 열처리 효과연구)

  • Kim, Dae Weon;Jang, Seong Min;Lee, Du Hui;Park, June Yi;Kim, Young Bae
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.34 no.4
    • /
    • pp.159-164
    • /
    • 2021
  • The Improvement of thermal performance using heat treatment of carbon nanotubes coated on the copper heat sink to take the radiation energy from solar ray for the energy harvesting in earth orbit. Using the additive coating of purified CNT for the increase of specific area and development of thermal conductive capacity, the performance of heat transfer is improved about 0.181 K/W while applying the power of 22 W under temperature of 3.98℃. Coating of purified CNT shows increase of area and volume of thermal layer however it led the partial thermal resistance.