The Specification of OPC and Micro Cement using the Admixture (보통포틀랜드 시멘트와 초미립자 시멘트의 혼화재료 혼입시 특성)

  • Kim, Deuck-Mo;Lee, Wha-Young;Park, Won-Chun;Mun, Kyung-Ju;Soh, Seung-Young;Soh, Yang-Seob
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.905-908
    • /
    • 2008
  • The existing concrete using ordinary portland cement has difficult in earth strength. so our study proceeded in using the micro cement. the result of experiment is follow that strength of micro cement was hard better than ordinary portland cement in early strength but flow of ordinary portland cement was better than micro cement. when OPC and MC mixed by fly-ash, flow degree is increased because of ball baring. fly-ash type wicked in early strength but flyash type hard than 28days strength of OPC. flow of GBFS is decreased, early strength is increased. when fly-ash mixed in MC, it was wicked strength.

  • PDF

A Study of Blast Furnace Slag Cement of High Early Strength and Replacement Ordinary Portland Cement (조강형 고로 슬래그 시멘트 및 보통 포틀랜드 시멘트 대체용 고로 슬래그 시멘트에 관한 연구)

  • 권기동;최현국
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1211-1214
    • /
    • 2000
  • The purpose of this paper was to study of blast furnace slag cement of high early strength and replacement ordinary portland cement. we prepared the specimens of cement and concrete with various mixing proportions of elementary materials. For example, clinker, gypsum(1~10%), fineness $4, 000~6, 000cm^2/g$ of blast furnace slag(30~50%), limestone etc. As a result of this study, fineness $(4, 000cm^2/g)$ blast furnace slag was of used replacement ordinary portland cement and fineness $(6, 000cm^2/g)$ blast furnace slag was of used blast furnace slag cement of high early strength.

A Comparison Study on Quality Regulation of China and Korea Cement (중국과 한국 시멘트의 품질규정에 대한 비교 연구)

  • Pei, Chang-Chun;Jin, Hu-Lin;Li, Bai-Shou;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.159-162
    • /
    • 2006
  • This study generally compared and investigated cement type and quality of China and Korea. Cement in Korea is divided into five such as ordinary, high early strength, moderate heat, low heat and sulfate resistance portland cement. However cement in China is divided into portland cement($P{\cdot}I,\;P{\cdot}II$) and ordinary portland cement($P{\cdot}O$) with admixture displacement ratio and it is again divided into 6 level and 7 level with 28 days compressive strength. In addition China classified cement into several standards, such as Mgo, SO3,, igloss, blame, setting time, stability, strength, alkali and sampling test. Therefore it should be careful to conclude so quickly without right understanding whether quality of China cement is bad or good. The better way to evaluate China cement is synthetically understanding a value engineering and consumer awareness.

  • PDF

Development of Application Block Using Geobond and Ash from Sewage Sludge Incinerator II (하수슬러지 소각재와 무기바인더를 이용한 응용 블록 개발 II)

  • Lee, Hyun-joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.7
    • /
    • pp.412-417
    • /
    • 2015
  • This study investigated to recycle geobond and ash produced in thesewage sludge incinerator using reduction/stabilization. Nonsintering process was performed by binding cement (High Early Strength Portland cement, Micro cement), geobond and sand mixed with sewage sludge ash (SSA). Chemical ingradients of the sewage sludge ash was mainly composed of $SiO_2$, $Al_2O_3$, $Fe_2O_3$, CaO and others, which were similar to those of the each binders consisting High Early Strength Portland cement, Micro cement and geobond. Results showed that unconfined the long term compressive strength could be obtained components of sewage sludge ash. It exceeded more than double score 64.6 MPa of the Korean standard ($22.54MPa=229.7kg/cm^2$). Microstructure of solidified block for the different admixture was related to the compressive strength according to SEM analysis. Optimum mixing range of the sewage sludge ash to each binders were found to be 10~40% which can widly safely regulate the confined a long term compressive strength. The best binder of long term compressive strengh was revealed Geobond more than High Early Strength Portland cement and Micro cement. This study revealed the sewage sludge ash can be partial replacement of the inorganic binder & application block for recycling.

The On-site Quality Characteristics of the Cold Weather Concrete using High Early Strength Portland Cement (조강포틀랜드시멘트를 사용한 한중콘크리트의 현장품질 특성)

  • Lee, Won-Am;Um, Tae-Sun;Ryu, Jae-Sang;Lee, Jong-Ryul;Kang, Ji-Hun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.224-227
    • /
    • 2004
  • The cement can be influenced by the temperature. Especially, when it is cold weather, it causes some problems in such properties as mixing, placing and curing of concrete. According to the Concrete Standard Specification(2003), in case of the average daily outdoor temperature below $4^{\circ}C$, it recommends to use the cold weather concrete. In this research, the on-site quality characteristics of the cold weather concrete using high early strength portland cement(Type III cement) were studied. As a result, the cold weather concrete using high early strength portland cement can obtain its excellent properties and benefit the cost of construction.

  • PDF

A Study on the Adhesive Performance of High-early Strengthening Polymer Cement Composites for Crack Repair of RC Structures (RC 구조물의 균열보수용 조강성 폴리머 시멘트 복합체의 접착성능에 관한 연구)

  • Park, Dong-Yeop;Kim, Sang-Hyeon;Jo, Young-Kug
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.179-180
    • /
    • 2023
  • The adhesion performance of PCCs for crack repair of RC structures was greater in the case of using ultra high-early strength cement than in the case of using ordinary Portland cement, and the effect of mixing silica fume was higher in the case of ordinary Portland cement than that of ultra high-early strength cement. On the other hand, 130% of W/C was more fluid than 80% of W/C in the same P/C 80%, which increased the fillability and improved the strength, but the strength improvement effect was the greatest in adhesion in flexure. Through this study, the basic characteristics of the adhesion performance of PCCs were identified, and based on this, it is necessary to induce an optimal mixing design that can increase adhesion performance through various mixing designs.

  • PDF

The Mechanical Characteristics and Hydration Heat on the Cold Weather Concrete using High Early Strength Portland Cement (조강시멘트를 사용한 한중콘크리트의 수화발열 및 역학적 특성)

  • Lee Won Am;Um Tae Sun;Ryu Jae Sang;Lee Jong Ryul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.305-308
    • /
    • 2004
  • Cold weather concrete is the concrete which is used during construction under low-temperature' environment, and this kind of concrete has to be taken care not to be frozen in early ages of setting-hardening, It is specified in the Concrete Standard Specification(2003) as 'the cold weather concrete must be used on the weather condition under the average daily outdoor temperature below $4^{\circ}C$.' In this research, the mechanical characteristics and hydration heat on the cold weather concrete using high early strength portland cement were studied. As a result, the excellent quality was obtained and high early strength portland cement is expected to be used widely as the cold weather concrete.

  • PDF

A Study and Evaluation of Super High Early Strength Concrete as Pavement Overlay Materials for Early Traffic Opening(3) (신속개방형 콘크리트 도로포장재의 설계를 위한 평가 연구(3))

  • 임채용;엄태선;유재상;이종열;엄주용;조윤호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.607-612
    • /
    • 2002
  • In road pavements, it is known that cement concrete pavement has superior durability, safety compared. But in repairing pavement, cement concrete pavement is not usually applied because of the length of time while the road is interrupted when using Ordinary and Rapid-hardening Portland Cement. And Super High Early Strength Cement and Ultra Super High Early Strength Cement are not favorable for ready mixed concrete because of rapid setting time, high slump loss and other restrictions. We developed special cement developing 1 day strength of over 30.0N/mm$^2$ to open the road within 1 day and workable time is maintained over 1 hour so that it can be used as ready mixed concrete. We performed experimental overlay construction with the cement and evaluated the mechanical property and the durability. At curing temperature of 8-l8$^{\circ}C$,the flexural strength was 6.4N/mm$^2$at 1 day, so that the road can be open to traffic within 1 day. In durability test, the hardened concrete showed higher durability than Portland cement concrete.

  • PDF

Properties of Low Heat Portland Cement Concrete by Changing Temperature of Aggregate (골재의 온도 변화에 따른 저발열 포틀랜드 시멘트 콘크리트의 특성)

  • Cho, Yong-Chin;Park, Kwang-Su;Shin, Su-Gyun;Won, Jong-Pil
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.4
    • /
    • pp.49-55
    • /
    • 2004
  • Properties of concrete using low heat portland cement is different from using ordinary portland cement and temperature of aggregate can be expected to have an important influence on its properties. In this study, experiment by setting up 5 levels (40, 30, 20, 4, $-2^{\circ}C$) by temperature of aggregate for evaluation properties of concrete using low heat portland cement was conducted. The experiments include slump test, air content test, change of slump, change of air content and compressive strength of concrete test. As the result of experiments, slump and air content was decreased by increasing temperature of aggregate. But it was not exceeding it's limit. Change of slump and air content was rapidly decrease by decreasing temperature of aggregate. At early age, compressive strength was influenced by the temperature of aggregate.

A Study on the Effect of Concrete Strength by Pozzolan and High-early Strength Cement (조강 및 포조란시멘트 의결경화촉진이 콘크리트 강도에 미치는 영향에 관한 연구)

  • 전현우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.14 no.3
    • /
    • pp.2677-2684
    • /
    • 1972
  • This study was carried out to search for an effect on strengths of a pozzolan and a high-early strength cements due to accelerating the initial setting and a rate of strength development at early age, and to obtain the effects applicable for structural construction works safety in the cold winter weather. The results of the study were as follows: 1. The early strength of high-early strength cement was higher than an ordinary portland cement(Type I). 2. High-early strength cement had a characteristic suitable for construction works in the cold weather due to the rate of acceleration of the eary strength. 3. When using pozzolan cements, a weight proportion should be considered in mix design since the pozzolan cement has a lower specific gravity than other portland cements. 4. It was desirable for the pozzolan cement to shorten the storage period since particles of the pozzolan cement was so fine that it was likely to weathering.

  • PDF