Journal of the Korean Association of Oral and Maxillofacial Surgeons
/
v.46
no.3
/
pp.162-173
/
2020
Dental implants are the first option for replacement of missing teeth. Failure usually involves additional cost and procedures. As a result, the physician should limit the risk factors associated with implant failures. Implant site is one of many factors that can influence the success or failure of dental implants. The association between early implant failure (EIF) and implant site has yet to be documented. This review aims to estimate the impact of insertion site on the percentage of EIFs. An electronic and manual search of studies that reported early failure of dental implants based on collection site. A total of 21 studies were included in the review and examined for the association between EIF and alveolar site. Subgroup analysis, including a comparison between implants inserted in four alveolar ridge regions of both jaws was performed. The early failure rate was higher for maxillary implants (3.14%) compared to mandibular implants (1.96%). Applying a random effect, risk ratio (RR), and confidence interval (CI) of 95% revealed higher failure in the maxilla compared to the mandible (RR 1.41; 95% CI [1.19, 1.67]; P<0.0001; I2=58%). The anterior maxilla is more critical for early implant loss than other alveolar bone sites. Implants in the anterior mandible exhibited the best success rate compared of the sites.
Purpose: The aim of this retrospective study was to determine the prevalence of early implant failure using a single implant system and to identify the factors contributing to early implant failure. Methods: Patients who received implant treatment with a single implant system ($Luna^{(R)}$, Shinhung, Seoul, Korea) at Dankook University Dental Hospital from 2015 to 2017 were enrolled. The following data were collected for analysis: sex and age of the patient, seniority of the surgeon, diameter and length of the implant, position in the dental arch, access approach for sinus-floor elevation, and type of guided bone regeneration (GBR) procedure. The effect of each predictor was evaluated using the crude hazard ratio and the adjusted hazard ratio (aHR) in univariate and multivariate Cox regression analyses, respectively. Results: This study analyzed 1,031 implants in 409 patients, who comprised 169 females and 240 males with a median age of 54 years (interquartile range [IQR], 47-61 years) and were followed up for a median of 7.2 months (IQR, 5.6-9.9 months) after implant placement. Thirty-five implants were removed prior to final prosthesis delivery, and the cumulative survival rate in the early phase at the implant level was 95.6%. Multivariate regression analysis revealed that seniority of the surgeon (residents: aHR=2.86; 95% confidence interval [CI], 1.37-5.94) and the jaw in which the implant was placed (mandible: aHR=2.31; 95% CI, 1.12-4.76) exerted statistically significant effects on early implant failure after adjusting for sex, age, dimensions of the implant, and type of GBR procedure (preoperative and/or simultaneous) (P<0.05). Conclusions: Prospective studies are warranted to further elucidate the factors contributing to early implant failure. In the meantime, surgeons should receive appropriate training and carefully select the bone bed in order to minimize the risk of early implant failure.
Purpose: To determine the utility of secondary circulating prostate cells for predicting early biochemical failure after radical prostatectomy for prostate cancer and compare the results with the Walz nomagram. Materials and Methods: A single centre, prospective study of men with prostate cancer treated with radical prostatectomy between 2004 and 2014 was conducted, with registration of clinical-pathological details, total serum PSA pre-surgery, Gleason score, extracapsular extension, positive surgical margins, infiltration of lymph nodes, seminal vesicles and pathological stage. Secondary circulating prostate cells were obtained using differential gel centrifugation and assessed using standard immunocytochemistry with anti-PSA. Biochemical failure was defined as a PSA >0.2ng/ml, predictive values werecalculated using the Walz nomagram and CPC detection. Results: A total of 326 men participated, with a median follow up of 5 years; 64 had biochemical failure within two years. Extracapsular extension, positive surgical margins, pathological stage, Gleason score ${\geq}8$, infiltration of seminal vesicles and lymph nodes were all associated with higher risk of biochemical failure. The discriminative value for the nomogram and circulating prostate cells was high (AUC >0.80), predictive values were higher for circulating prostate cell detection, with a negative predictive value of 99%, sensitivity of 96% and specificity of 75%. Conclusions: The nomagram had good predictive power to identify men with a high risk of biochemical failure within two years. The presence of circulating prostate cells had the same predictive power, with a higher sensitivity and negative predictive value. The presence of secondary circulating prostate cells identifies a group of men with a high risk of early biochemical failure. Those negative for secondary CPCs have a very low risk of early biochemical failure.
Journal of the Korean Society of Hazard Mitigation
/
v.4
no.3
s.14
/
pp.9-17
/
2004
In recent years slope failure due to heavy rainfalls or local downpours usually accompanied by typhoons has increasingly occurred in Korea. Also, the damages caused by slope failure have a tendency to be more disastrous than before. This study has been conducted to prepare an early warning system for slope failure by : (1) analyzing types and causes of slope failure, (2) examining the published evaluation criteria for slope stability, (3) estimating slope stability by considering the properties of slope-forming materials as well as the topographical and geological properties of slopes, and (4) determining the most important variables of affecting the stability of the slope under consideration. The data on the variations of slope conditions measured by an automatic in-situ measurement system and then transmitted to the central analysis system by using an internet. The most important variables can be back-calculated in the central system and compared with the values for the first and second management criteria. These management criteria should be modified and corrected continuously in the future by accumulated data and knowledge related to the early warning system for slope failure.
The objective of the study is to verify the discriminatory power of technology innovation in predicting Early Stage Ventures' success or failure. To accomplish this objective, we test early stage ventures'(Firm's period is below 3 years)technology innovation and performance. The result of the study is expected to be useful in loan evaluation, investment decision, internal management decision making and business improvement. The results of study is as follows. First, Early Stage Ventures' technology innovation power is composed of 4 major indexes(technology, marketability, manufacturing infra and economic feasibility). Second, we find that thirty-seven minor indexes are significant ex-ante variable which are discriminating between firms' success and failure in Early Stage Ventures. Also thirty-seven minor indexes explain 57.2% of the total variance. This explainable power of these indexes is similar to that of the existing 58 index elements. Finally, we find that the most important technology innovation power of Early Stage Ventures' is economic feasibility.
Present study was undertaken in order to document early renal ultrasonographic changes of gentamicin nephrotoxicosis and to show the value of renal ultrasonography as a contributory means of early diagnosis of acute renal failure in dogs. The experimental design was a randomized complete block design with six treatments in two blocks (gentamicin-treated & saline-treated). Acute renal failure was induced by toxic dosage of gentamicin (30 mg/kg) and saline solution sham equivalent in volume to that of the toxic dosage of gentamicin (1.5-3ml). Subjective visualization of increased renal cortex was visible as homogenous echoes that were hypoechoic relative to the surrounding tissues, whereas the renal medulla was anechoic to slightly hypoechoic. After treatment, the renal cortex was hyperechoic relative to the surrounding tissue. Increased renal cortex echogenicity was associated with significant nephrotoxicosis and was superior to serum creatinine elevation in nephrotoxicosis detection. Urine GGT was superior to other clinicopathological data utilized in the diagnosis of nephrotoxicosis. Based on the above results, increased renal cortex echogenicity seemed to be of use in detecting of acute renal failure.
Kim, Sung-Wook;Choi, Eun-Kyoung;Park, Dug-Keun;Park, Jung-Hoon;Son, Sung-Gon
Proceedings of the Korean Geotechical Society Conference
/
2010.09a
/
pp.253-262
/
2010
In this study, localized heavy rainfall occurred during the collapse of steep slopes adjacent to the construction site and to ensure the safety of residents to build an early warning system was performed. Forecast/Alert range was estimated based on vulnerability landslide map and past disaster history. And established a critical line in consideration of the characteristics of local rainfall and operating a snake line, the study calculated causing and non-causing points. Also, be measured in real-time analysis of rainfall data in conjunction with the system before the steep slope failure occurred forecast/Alert System is presented.
The successful and sustainable growth of SMEs depends on their ability of strengthen their competitiveness in quality and cost and service more than anything else as a fundamental of operation. Among these key competitive factors of SMEs, quality is the most critical factor in manufacturing business fields. There are many different ways to improve the quality performance but it needs proper management decision to choose the best way what can maximize outputs with minimum inputs. And it needs effective measurement methods and some indicators to analysis the quality performance properly. The quality cost is one of the simplest key indicators to measure the quality performance and the effectiveness of quality related management decisions. In this study, through survey on local SMEs, we found that their average annual quality cost ratio versus turnover - total amount of annual quality cost divided by annual turnover - is around 3.69% excluded some SME's performances what have different quality control measures with others. And we found some results what corresponded with the early studies on the correlations between those categorized quality costs factors and some discrepancies between some of the literature model and the early case study results as follows. There were negative correlations between the Prevention costs and the External failure costs, and the Appraisal costs and the External failure costs, and there was positive correlation between the Appraisal costs and Internal failure costs same as early studies. But, we couldn't found any strong negative correlations between the Cost of control - Prevention costs & Appraisal costs - and the Cost of Failure of control - Internal & External failure costs -.
Although many researches related to monitoring and automatic measuring devices for early warning system during slope failure have been carried out in Korea and aboard, most of the researches have installed measuring devices on the slope surface, and there are only few researches about warning systems that can detect and warn before slope failure and disaster occurs. In this study, slope failure simulation experiment was performed by attaching sensors to rock bolts, and initial slope behavior characteristics during slope failure were analyzed. Also, the experiment results were compared and reviewed with varied slope conditions, i.e. shotcrete slope and natural slope, and varied material conditions, i.e. GFRP and steel rock bolt. This study can be used as a basic data in development of warning and alarm system for early evacuation through early detection and warning before slope failure occurs in steep slopes and slope failure vulnerable areas.
Transactions of the Korean Society of Automotive Engineers
/
v.17
no.2
/
pp.112-117
/
2009
The new suspension, called ISU(In-arm suspension system) was developed for Infantry Fighting Vehicle. During vehicle field test, early failure of ISU's sealing system was occurred after driving the paved road. From the failure analysis, ISU's displacement data was obtained. In analysis of PSD data, track induced vibration which has high frequency and small amplitude characteristics, was dominant. Such track vibration would result in early seal failure because of friction increase and lack of lubrication. To simulate track vibration environment in laboratory, seals were tested under the condition of 20Hz, ${\pm}1$, ${\pm}2mm$ amplitude. The same type of seal failure occurred in vehicle test, was reproduced in the lab test under ${\pm}1mm$ amplitude. From the test results, the durability of improved seal was increased by 2.5 times compared with the previous one.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.