• Title/Summary/Keyword: Early Failure

Search Result 1,220, Processing Time 0.028 seconds

The impact of the alveolar bone sites on early implant failure: a systematic review with meta-analysis

  • Fouda, Atef Abdel Hameed
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.3
    • /
    • pp.162-173
    • /
    • 2020
  • Dental implants are the first option for replacement of missing teeth. Failure usually involves additional cost and procedures. As a result, the physician should limit the risk factors associated with implant failures. Implant site is one of many factors that can influence the success or failure of dental implants. The association between early implant failure (EIF) and implant site has yet to be documented. This review aims to estimate the impact of insertion site on the percentage of EIFs. An electronic and manual search of studies that reported early failure of dental implants based on collection site. A total of 21 studies were included in the review and examined for the association between EIF and alveolar site. Subgroup analysis, including a comparison between implants inserted in four alveolar ridge regions of both jaws was performed. The early failure rate was higher for maxillary implants (3.14%) compared to mandibular implants (1.96%). Applying a random effect, risk ratio (RR), and confidence interval (CI) of 95% revealed higher failure in the maxilla compared to the mandible (RR 1.41; 95% CI [1.19, 1.67]; P<0.0001; I2=58%). The anterior maxilla is more critical for early implant loss than other alveolar bone sites. Implants in the anterior mandible exhibited the best success rate compared of the sites.

Early implant failure: a retrospective analysis of contributing factors

  • Kang, Dae-Young;Kim, Myeongjin;Lee, Sung-Jo;Cho, In-Woo;Shin, Hyun-Seung;Caballe-Serrano, Jordi;Park, Jung-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.5
    • /
    • pp.287-298
    • /
    • 2019
  • Purpose: The aim of this retrospective study was to determine the prevalence of early implant failure using a single implant system and to identify the factors contributing to early implant failure. Methods: Patients who received implant treatment with a single implant system ($Luna^{(R)}$, Shinhung, Seoul, Korea) at Dankook University Dental Hospital from 2015 to 2017 were enrolled. The following data were collected for analysis: sex and age of the patient, seniority of the surgeon, diameter and length of the implant, position in the dental arch, access approach for sinus-floor elevation, and type of guided bone regeneration (GBR) procedure. The effect of each predictor was evaluated using the crude hazard ratio and the adjusted hazard ratio (aHR) in univariate and multivariate Cox regression analyses, respectively. Results: This study analyzed 1,031 implants in 409 patients, who comprised 169 females and 240 males with a median age of 54 years (interquartile range [IQR], 47-61 years) and were followed up for a median of 7.2 months (IQR, 5.6-9.9 months) after implant placement. Thirty-five implants were removed prior to final prosthesis delivery, and the cumulative survival rate in the early phase at the implant level was 95.6%. Multivariate regression analysis revealed that seniority of the surgeon (residents: aHR=2.86; 95% confidence interval [CI], 1.37-5.94) and the jaw in which the implant was placed (mandible: aHR=2.31; 95% CI, 1.12-4.76) exerted statistically significant effects on early implant failure after adjusting for sex, age, dimensions of the implant, and type of GBR procedure (preoperative and/or simultaneous) (P<0.05). Conclusions: Prospective studies are warranted to further elucidate the factors contributing to early implant failure. In the meantime, surgeons should receive appropriate training and carefully select the bone bed in order to minimize the risk of early implant failure.

Comparison of the Walz Nomogram and Presence of Secondary Circulating Prostate Cells for Predicting Early Biochemical Failure after Radical Prostatectomy for Prostate Cancer in Chilean Men

  • Murray, Nigel P;Reyes, Eduardo;Orellana, Nelson;Fuentealba, Cynthia;Jacob, Omar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.7123-7127
    • /
    • 2015
  • Purpose: To determine the utility of secondary circulating prostate cells for predicting early biochemical failure after radical prostatectomy for prostate cancer and compare the results with the Walz nomagram. Materials and Methods: A single centre, prospective study of men with prostate cancer treated with radical prostatectomy between 2004 and 2014 was conducted, with registration of clinical-pathological details, total serum PSA pre-surgery, Gleason score, extracapsular extension, positive surgical margins, infiltration of lymph nodes, seminal vesicles and pathological stage. Secondary circulating prostate cells were obtained using differential gel centrifugation and assessed using standard immunocytochemistry with anti-PSA. Biochemical failure was defined as a PSA >0.2ng/ml, predictive values werecalculated using the Walz nomagram and CPC detection. Results: A total of 326 men participated, with a median follow up of 5 years; 64 had biochemical failure within two years. Extracapsular extension, positive surgical margins, pathological stage, Gleason score ${\geq}8$, infiltration of seminal vesicles and lymph nodes were all associated with higher risk of biochemical failure. The discriminative value for the nomogram and circulating prostate cells was high (AUC >0.80), predictive values were higher for circulating prostate cell detection, with a negative predictive value of 99%, sensitivity of 96% and specificity of 75%. Conclusions: The nomagram had good predictive power to identify men with a high risk of biochemical failure within two years. The presence of circulating prostate cells had the same predictive power, with a higher sensitivity and negative predictive value. The presence of secondary circulating prostate cells identifies a group of men with a high risk of early biochemical failure. Those negative for secondary CPCs have a very low risk of early biochemical failure.

A Study on the Introduction of Early Warning System for Slope Failure (사면붕괴 예.경보시스템 도입에 관한 연구)

  • Kim, Hak-Seung;Cho, Nam-Jun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.3 s.14
    • /
    • pp.9-17
    • /
    • 2004
  • In recent years slope failure due to heavy rainfalls or local downpours usually accompanied by typhoons has increasingly occurred in Korea. Also, the damages caused by slope failure have a tendency to be more disastrous than before. This study has been conducted to prepare an early warning system for slope failure by : (1) analyzing types and causes of slope failure, (2) examining the published evaluation criteria for slope stability, (3) estimating slope stability by considering the properties of slope-forming materials as well as the topographical and geological properties of slopes, and (4) determining the most important variables of affecting the stability of the slope under consideration. The data on the variations of slope conditions measured by an automatic in-situ measurement system and then transmitted to the central analysis system by using an internet. The most important variables can be back-calculated in the central system and compared with the values for the first and second management criteria. These management criteria should be modified and corrected continuously in the future by accumulated data and knowledge related to the early warning system for slope failure.

Empirical Study on Relationship Between ex-ante Early Stage Venture Technology Innovation Power and ex-post Firm's Performance (초기 중소벤처의 기술혁신역량과 기업성과의 관계에 관한 연구)

  • Yang, Dong Woo
    • Knowledge Management Research
    • /
    • v.7 no.1
    • /
    • pp.49-63
    • /
    • 2006
  • The objective of the study is to verify the discriminatory power of technology innovation in predicting Early Stage Ventures' success or failure. To accomplish this objective, we test early stage ventures'(Firm's period is below 3 years)technology innovation and performance. The result of the study is expected to be useful in loan evaluation, investment decision, internal management decision making and business improvement. The results of study is as follows. First, Early Stage Ventures' technology innovation power is composed of 4 major indexes(technology, marketability, manufacturing infra and economic feasibility). Second, we find that thirty-seven minor indexes are significant ex-ante variable which are discriminating between firms' success and failure in Early Stage Ventures. Also thirty-seven minor indexes explain 57.2% of the total variance. This explainable power of these indexes is similar to that of the existing 58 index elements. Finally, we find that the most important technology innovation power of Early Stage Ventures' is economic feasibility.

  • PDF

Ultrasonographic Changes of Acute Renal Failure Induced by Gentamicin in Dogs (개에서 겐타마이신으로 유발된 급성 신부전의 초음파상 변화)

  • 진경훈;정종태
    • Journal of Veterinary Clinics
    • /
    • v.18 no.1
    • /
    • pp.35-43
    • /
    • 2001
  • Present study was undertaken in order to document early renal ultrasonographic changes of gentamicin nephrotoxicosis and to show the value of renal ultrasonography as a contributory means of early diagnosis of acute renal failure in dogs. The experimental design was a randomized complete block design with six treatments in two blocks (gentamicin-treated & saline-treated). Acute renal failure was induced by toxic dosage of gentamicin (30 mg/kg) and saline solution sham equivalent in volume to that of the toxic dosage of gentamicin (1.5-3ml). Subjective visualization of increased renal cortex was visible as homogenous echoes that were hypoechoic relative to the surrounding tissues, whereas the renal medulla was anechoic to slightly hypoechoic. After treatment, the renal cortex was hyperechoic relative to the surrounding tissue. Increased renal cortex echogenicity was associated with significant nephrotoxicosis and was superior to serum creatinine elevation in nephrotoxicosis detection. Urine GGT was superior to other clinicopathological data utilized in the diagnosis of nephrotoxicosis. Based on the above results, increased renal cortex echogenicity seemed to be of use in detecting of acute renal failure.

  • PDF

Establishment of Early Warning System of Steep Slope Failure Using Real-time Rainfall Data Analysis (실시간 강우자료분석을 활용한 산사태 경보시스템 연구)

  • Kim, Sung-Wook;Choi, Eun-Kyoung;Park, Dug-Keun;Park, Jung-Hoon;Son, Sung-Gon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.253-262
    • /
    • 2010
  • In this study, localized heavy rainfall occurred during the collapse of steep slopes adjacent to the construction site and to ensure the safety of residents to build an early warning system was performed. Forecast/Alert range was estimated based on vulnerability landslide map and past disaster history. And established a critical line in consideration of the characteristics of local rainfall and operating a snake line, the study calculated causing and non-causing points. Also, be measured in real-time analysis of rainfall data in conjunction with the system before the steep slope failure occurred forecast/Alert System is presented.

  • PDF

The Correlations among the Categorized Quality Cost Factors on Small & Medium-sized Enterprises (국내 중소 제조기업의 품질비용 행태에 관한 실증 연구)

  • Koo, Il-Seob;Lee, Sang-Choon;Jang, Kwang-Soon;Kim, Yong-Bum
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.185-193
    • /
    • 2011
  • The successful and sustainable growth of SMEs depends on their ability of strengthen their competitiveness in quality and cost and service more than anything else as a fundamental of operation. Among these key competitive factors of SMEs, quality is the most critical factor in manufacturing business fields. There are many different ways to improve the quality performance but it needs proper management decision to choose the best way what can maximize outputs with minimum inputs. And it needs effective measurement methods and some indicators to analysis the quality performance properly. The quality cost is one of the simplest key indicators to measure the quality performance and the effectiveness of quality related management decisions. In this study, through survey on local SMEs, we found that their average annual quality cost ratio versus turnover - total amount of annual quality cost divided by annual turnover - is around 3.69% excluded some SME's performances what have different quality control measures with others. And we found some results what corresponded with the early studies on the correlations between those categorized quality costs factors and some discrepancies between some of the literature model and the early case study results as follows. There were negative correlations between the Prevention costs and the External failure costs, and the Appraisal costs and the External failure costs, and there was positive correlation between the Appraisal costs and Internal failure costs same as early studies. But, we couldn't found any strong negative correlations between the Cost of control - Prevention costs & Appraisal costs - and the Cost of Failure of control - Internal & External failure costs -.

Slope Behavior Analysis Using the Measurement of GFRP Underground Displacement (GFRP 록볼트 계측을 통한 사면 거동 분석)

  • Jin, Ji-Huan;Lim, Hyun-Taek;Bibek, Tamang;Chang, Suk-Hyun;Kim, Yong-Seong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.11-19
    • /
    • 2018
  • Although many researches related to monitoring and automatic measuring devices for early warning system during slope failure have been carried out in Korea and aboard, most of the researches have installed measuring devices on the slope surface, and there are only few researches about warning systems that can detect and warn before slope failure and disaster occurs. In this study, slope failure simulation experiment was performed by attaching sensors to rock bolts, and initial slope behavior characteristics during slope failure were analyzed. Also, the experiment results were compared and reviewed with varied slope conditions, i.e. shotcrete slope and natural slope, and varied material conditions, i.e. GFRP and steel rock bolt. This study can be used as a basic data in development of warning and alarm system for early evacuation through early detection and warning before slope failure occurs in steep slopes and slope failure vulnerable areas.

Durability Improvement of High Pressure Seal for ISU under the Track Vibration (궤도진동에 대한 ISU 고압 시일 내구성능 개선)

  • Han, In-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.2
    • /
    • pp.112-117
    • /
    • 2009
  • The new suspension, called ISU(In-arm suspension system) was developed for Infantry Fighting Vehicle. During vehicle field test, early failure of ISU's sealing system was occurred after driving the paved road. From the failure analysis, ISU's displacement data was obtained. In analysis of PSD data, track induced vibration which has high frequency and small amplitude characteristics, was dominant. Such track vibration would result in early seal failure because of friction increase and lack of lubrication. To simulate track vibration environment in laboratory, seals were tested under the condition of 20Hz, ${\pm}1$, ${\pm}2mm$ amplitude. The same type of seal failure occurred in vehicle test, was reproduced in the lab test under ${\pm}1mm$ amplitude. From the test results, the durability of improved seal was increased by 2.5 times compared with the previous one.